Paola Bagnoli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paola Bagnoli has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Maria Laura Costantino
Politecnico di Milano, Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, LaBS, Milan, Italy
17 shared publications Roberto Fumero
8 shared publications- Emanuela Marcelli
Laboratory of Bioengineering—eDIMES Lab, Department of Medical and Surgical Sciences (DIMEC), University of Bologna, 40138 Bologna, Italy
5 shared publications - Laura Cercenelli
Laboratory of Bioengineering—eDIMES Lab, Department of Medical and Surgical Sciences (DIMEC), University of Bologna, 40138 Bologna, Italy
5 shared publications - Marta Serrani
Department of Chemical Engineering and Biotechnology University of Cambridge Pembroke Street CB2 3RA Cambridge UK
4 shared publications Adriano Zaffora
3 shared publications
Latest Publications
- Open Access
The cardiac torsion as a sensitive index of heart pathology: A model study
The torsional behaviour of the heart (i.e. the mutual rotation of the cardiac base and apex) was proved to be sensitive to alterations of some cardiovascular parameters, i.e. preload, afterload and contractility. Moreover, pathologies which affect the fibers architecture and cardiac geometry were proved to alter the cardiac torsion pattern. For these reasons, the cardiac torsion represents a sensitive index of ventricular performance. The aim of this work is to provide further insight into physiological and pathological alterations of the cardiac torsion by means of computational analyses, combining a structural model of the two ventricles with simple lumped parameter models of both the systemic and the pulmonary circulations. Starting from diagnostic images, a 3D anatomy based geometry of the two ventricles was reconstructed. The myocytes orientation in the ventricles was assigned according to literature data and the myocardium mechanical behavior was modelled by an anisotropic hyperelastic law. Both the active and the passive phases of the cardiac cycle were modelled, and different clinical conditions were simulated. The results in terms of alterations of the cardiac torsion in the presence of pathologies are in agreement
Open AccessThe cardiac torsion as a sensitive index of heart pathology: A model study
The torsional behaviour of the heart (i.e. the mutual rotation of the cardiac base and apex) was proved to be sensitive to alterations of some cardiovascular parameters, i.e. preload, afterload and contractility. Moreover, pathologies which affect the fibers architecture and cardiac geometry were proved to alter the cardiac torsion pattern. For these reasons, the cardiac torsion represents a sensitive index of ventricular performance. The aim of this work is to provide further insight into physiological and pathological alterations of the cardiac torsion by means of computational analyses, combining a structural model of the two ventricles with simple lumped parameter models of both the systemic and the pulmonary circulations. Starting from diagnostic images, a 3D anatomy based geometry of the two ventricles was reconstructed. The myocytes orientation in the ventricles was assigned according to literature data and the myocardium mechanical behavior was modelled by an anisotropic hyperelastic law. Both the active and the passive phases of the cardiac cycle were modelled, and different clinical conditions were simulated. The results in terms of alterations of the cardiac torsion in the presence of pathologies are in agreement
- Open Access
- 1 March 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 55, 104-119
The cardiac torsion as a sensitive index of heart pathology: A model study
- 1 March 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 55, 104-119
Open AccessThe cardiac torsion as a sensitive index of heart pathology: A model study
- Open Access
- 1 November 2015
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 38 (11) , 600-606
Fluid Dynamic Characterization of a Polymeric Heart Valve Prototype (Poli-Valve) Tested under Continuous and Pulsatile Flow Conditions
Purpose: Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy; the latter display better fluid dynamic behavior but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the hemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of 2 groups of newly developed supra-annular, trileaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. Methods: 2 types of Poli-Valves made of SBC and differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. A pulse duplicator designed ad hoc allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the behavior of the valve. Results: Both types of Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by the ISO 5840 Standard. Results were compared with 5 mechanical heart valves (MHVs) and 5 tissue heart valves (THVs), currently available on the market. Conclusions: Based on these results, PHVs based on styrenic block copolymers, as are Poli-Valves, can be considered a promising alternative for heart valve replacement in the near future.
- 1 November 2015
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 38 (11) , 600-606
Open AccessFluid Dynamic Characterization of a Polymeric Heart Valve Prototype (Poli-Valve) Tested under Continuous and Pulsatile Flow Conditions
Purpose: Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy; the latter display better fluid dynamic behavior but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the hemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of 2 groups of newly developed supra-annular, trileaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. Methods: 2 types of Poli-Valves made of SBC and differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. A pulse duplicator designed ad hoc allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the behavior of the valve. Results: Both types of Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by the ISO 5840 Standard. Results were compared with 5 mechanical heart valves (MHVs) and 5 tissue heart valves (THVs), currently available on the market. Conclusions: Based on these results, PHVs based on styrenic block copolymers, as are Poli-Valves, can be considered a promising alternative for heart valve replacement in the near future.
- 23 October 2015
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 37 (12) , 1133-1140
Gas transfer model to design a ventilator for neonatal total liquid ventilation
The study was aimed to optimize the gas transfer in an innovative ventilator for neonatal Total Liquid Ventilation (TLV) that integrates the pumping and oxygenation functions in a non-volumetric pulsatile device made of parallel flat silicone membranes. A computational approach was adopted to evaluate oxygen (O2) and carbon dioxide (CO2) exchanges between the liquid perfluorocarbon (PFC) and the oxygenating gas, as a function of the geometrical parameter of the device. A 2D semi-empirical model was implemented to this purpose using Comsol Multiphysics to study both the fluid dynamics and the gas exchange in the ventilator. Experimental gas exchanges measured with a preliminary prototype were compared to the simulation outcomes to prove the model reliability. Different device configurations were modeled to identify the optimal design able to guarantee the desired gas transfer. Good agreement between experimental and simulation outcomes was obtained, validating the model. The optimal configuration, able to achieve the desired gas exchange (ΔpCO2 = 16.5 mmHg and ΔpO2 = 69 mmHg), is a device comprising 40 modules, 300 mm in length (total exchange area = 2.28 m(2)). With this configuration gas transfer performance is satisfactory for all the simulated settings, proving good adaptability of the device.
- 23 October 2015
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 37 (12) , 1133-1140
Gas transfer model to design a ventilator for neonatal total liquid ventilation
The study was aimed to optimize the gas transfer in an innovative ventilator for neonatal Total Liquid Ventilation (TLV) that integrates the pumping and oxygenation functions in a non-volumetric pulsatile device made of parallel flat silicone membranes. A computational approach was adopted to evaluate oxygen (O2) and carbon dioxide (CO2) exchanges between the liquid perfluorocarbon (PFC) and the oxygenating gas, as a function of the geometrical parameter of the device. A 2D semi-empirical model was implemented to this purpose using Comsol Multiphysics to study both the fluid dynamics and the gas exchange in the ventilator. Experimental gas exchanges measured with a preliminary prototype were compared to the simulation outcomes to prove the model reliability. Different device configurations were modeled to identify the optimal design able to guarantee the desired gas transfer. Good agreement between experimental and simulation outcomes was obtained, validating the model. The optimal configuration, able to achieve the desired gas exchange (ΔpCO2 = 16.5 mmHg and ΔpO2 = 69 mmHg), is a device comprising 40 modules, 300 mm in length (total exchange area = 2.28 m(2)). With this configuration gas transfer performance is satisfactory for all the simulated settings, proving good adaptability of the device.
- Open Access
- 9 April 2015
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 15 (02)
A NEWLY DEVELOPED TRI-LEAFLET POLYMERIC HEART VALVE PROSTHESIS
The potential of polymeric heart valves (PHV) prostheses is to combine the hemodynamic performances of biological valves with the durability of mechanical valves. The aim of this work is to design and develop a new tri-leaflet prosthetic heart valve (HV) made from styrenic block copolymers. A computational finite element model was implemented to optimize the thickness of the leaflets, to improve PHV mechanical and hydrodynamic performances. Based on the model outcomes, 8 prototypes of the designed valve were produced and tested in vitro under continuous and pulsatile flow conditions, as prescribed by ISO 5840 Standard. A specially designed pulse duplicator allowed testing the PHVs at different flow rates and frequency conditions. All the PHVs met the requirements specified in ISO 5840 Standard in terms of both regurgitation and effective orifice area (EOA), demonstrating their potential as HV prostheses.
- 9 April 2015
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 15 (02)
Open AccessA NEWLY DEVELOPED TRI-LEAFLET POLYMERIC HEART VALVE PROSTHESIS
The potential of polymeric heart valves (PHV) prostheses is to combine the hemodynamic performances of biological valves with the durability of mechanical valves. The aim of this work is to design and develop a new tri-leaflet prosthetic heart valve (HV) made from styrenic block copolymers. A computational finite element model was implemented to optimize the thickness of the leaflets, to improve PHV mechanical and hydrodynamic performances. Based on the model outcomes, 8 prototypes of the designed valve were produced and tested in vitro under continuous and pulsatile flow conditions, as prescribed by ISO 5840 Standard. A specially designed pulse duplicator allowed testing the PHVs at different flow rates and frequency conditions. All the PHVs met the requirements specified in ISO 5840 Standard in terms of both regurgitation and effective orifice area (EOA), demonstrating their potential as HV prostheses.
- 1 November 2014
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 112 (5) , 1201-1211
Effect of intermediate ZrO2-CaO coatings deposited by cold thermal spraying on the titanium-porcelain bond in dental restorations
- 1 November 2014
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 112 (5) , 1201-1211
Effect of intermediate ZrO2-CaO coatings deposited by cold thermal spraying on the titanium-porcelain bond in dental restorations
- 1 February 2013
- Published by Elsevier in Journal of Biomechanics
- Vol. 46 (3) , 462-469
Finite element analysis of the mechanical behavior of preterm lamb tracheal bifurcation during total liquid ventilation
- 1 February 2013
- Published by Elsevier in Journal of Biomechanics
- Vol. 46 (3) , 462-469
Finite element analysis of the mechanical behavior of preterm lamb tracheal bifurcation during total liquid ventilation
- 27 July 2011
- Published by SAGE Publications in Journal of Applied Biomaterials & Functional Materials
- Vol. 9 (2) , 109-117
Trends in biomedical engineering: focus on Patient Specific Modeling and Life Support Systems
Over the last twenty years major advancements have taken place in the design of medical devices and personalized therapies. They have paralleled the impressive evolution of three-dimensional, non invasive, medical imaging techniques and have been continuously fuelled by increasing computing power and the emergence of novel and sophisticated software tools. This paper aims to showcase a number of major contributions to the advancements of modeling of surgical and interventional procedures and to the design of life support systems. The selected examples will span from pediatric cardiac surgery procedures to valve and ventricle repair techniques, from stent design and endovascular procedures to life support systems and innovative ventilation techniques.
- 27 July 2011
- Published by SAGE Publications in Journal of Applied Biomaterials & Functional Materials
- Vol. 9 (2) , 109-117
Trends in biomedical engineering: focus on Patient Specific Modeling and Life Support Systems
Over the last twenty years major advancements have taken place in the design of medical devices and personalized therapies. They have paralleled the impressive evolution of three-dimensional, non invasive, medical imaging techniques and have been continuously fuelled by increasing computing power and the emergence of novel and sophisticated software tools. This paper aims to showcase a number of major contributions to the advancements of modeling of surgical and interventional procedures and to the design of life support systems. The selected examples will span from pediatric cardiac surgery procedures to valve and ventricle repair techniques, from stent design and endovascular procedures to life support systems and innovative ventilation techniques.
- 1 April 2011
- Published by Elsevier in Journal of Biomechanics
- Vol. 44 (6) , 1040-1045
Experimental and computational biomechanical characterisation of the tracheo-bronchial tree of the bottlenose dolphin (Tursiops truncatus) during diving
- 1 April 2011
- Published by Elsevier in Journal of Biomechanics
- Vol. 44 (6) , 1040-1045
Experimental and computational biomechanical characterisation of the tracheo-bronchial tree of the bottlenose dolphin (Tursiops truncatus) during diving
- 1 January 2011
- Vol. 116 (3) , 159-64
The upper respiratory tract of dolphins.
The functional anatomy of the respiratory system of dolphins has been scarcely studied. Specifically, the capacity of the system to resist pressure changes during diving has not been fully understood. Here we shortly describe the upper respiratory tract of dolphins based on three common species, the bottlenose dolphin Tursiops truncatus, the Risso's dolphin Grampus griseus, and the striped dolphin Stenella coeruleoalba. We emphasize the keymorphological features that represent evolutionary adaptations to life in the water, and, furthermore, also present a model of the tracheo-bronchial tree based on mechanical characterization and subsequent computational simulation of its biomechanical behaviour. Comparisons with the goat allowed us to determine how different structures may respond to diving-related pressure.
- 1 January 2011
- Vol. 116 (3) , 159-64
The upper respiratory tract of dolphins.
The functional anatomy of the respiratory system of dolphins has been scarcely studied. Specifically, the capacity of the system to resist pressure changes during diving has not been fully understood. Here we shortly describe the upper respiratory tract of dolphins based on three common species, the bottlenose dolphin Tursiops truncatus, the Risso's dolphin Grampus griseus, and the striped dolphin Stenella coeruleoalba. We emphasize the keymorphological features that represent evolutionary adaptations to life in the water, and, furthermore, also present a model of the tracheo-bronchial tree based on mechanical characterization and subsequent computational simulation of its biomechanical behaviour. Comparisons with the goat allowed us to determine how different structures may respond to diving-related pressure.