Bryan Haddock
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Bryan Haddock has a total of 162 co-authors. Here are the top co-authors by number of shared publications:
Henrik B. W. Larsson
Department of Clinical Physiology and Nuclear Medicine Copenhagen University Hospital, Rigshospitalet Glostrup Denmark
5 shared publications- Ulrich Lindberg
Department of Clinical Physiology and Nuclear Medicine, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
4 shared publications Charlotte Suetta
Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
3 shared publications- Henrik Bo Wiberg Larsson
Functional Imaging Unit, Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital - Rigshospitalet, Glostrup, Denmark
3 shared publications - Niklas Rye Jørgensen
Department of Clinical Biochemistry, Rigshospitalet, Copenhagen, Denmark
3 shared publications Ulrik B. Andersen
Department of Clinical Physiology and Nuclear Medicine, Rigshospitalet–Glostrup, Copenhagen University Hospital 2 , Glostrup, Denmark
3 shared publications
Latest Publications
- Open Access
- 9 October 2026
- Published by Elsevier in Osteoarthritis and Cartilage Open
- Vol. 8 (4) , 100886
OpenMSK: A modular open-source framework for comprehensive analysis of imaging biomarkers in knee osteoarthritis
- 9 October 2026
- Published by Elsevier in Osteoarthritis and Cartilage Open
- Vol. 8 (4) , 100886
Open AccessOpenMSK: A modular open-source framework for comprehensive analysis of imaging biomarkers in knee osteoarthritis
- Open Access
- 29 June 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (8) , e70348
Reproducibility of Splanchnic Blood Flow Measured Using Phase‐Contrast MRI
Splanchnic vessel blood flow assessment can describe physiology or pathophysiology and also has clinical relevance for patients with altered abdominal blood flow, vascular neuropathy, or atherosclerotic conditions. Reliable and practicable methods for this assessment are needed. We assessed the reproducibility of non‐invasive phase‐contrast MRI (PC‐MRI) for measuring splanchnic blood flow and its feasibility for detecting postprandial blood flow changes. We included measurements from two groups of healthy individuals (Group A: n = 10; C: n = 10) and a group of patients with type 2 diabetes (B: n = 10) from randomized, single‐blind, placebo‐controlled studies, and assessed blood flow with 2D PC sequences (3 Tesla Siemens Biograph MRI and 3 Tesla Philips Achieva). Blood flow was measured in the arteria mesenterica superior, truncus coeliacus, arteria hepatica (Group A only), and vena portae hepatis over multiple days, with repeated scans each day to assess variability and reproducibility. To confirm detection of postprandial changes, nine repeated measurements were acquired during ingestion of 75‐g oral glucose tolerance test compared to water ingestion. Reproducibility was assessed by coefficient of variation (CoV) and limits of agreement with the mean (LoAM) using an extended Bland–Altman analysis. Blood flow in arteria mesenterica superior, truncus coeliacus, and vena portae hepatis demonstrated low intrasubject within session CoV (7%–22%) and intrasubject between session CoV (16%–26%). Blood flow in arteria hepatica had poorer CoV for both within sessions (12%) and between sessions (32%). Glucose ingestion induced a blood flow peak increase of 88% ± 52% in arteria mesenterica superior and 68% ± 36% in vena portae hepatis, both robustly detected, while no change was observed in the arteria hepatica or truncus coeliacus. In conclusion, PC‐MRI is a reproducible and feasible technique for measuring blood flow in arteria mesenterica superior, truncus coeliacus, and vena portae hepatis with the ability to detect postprandial changes. Trial Registration: ClinicalTrials.gov identifier: NCT05391581, NCT06426823, NCT06774807
- 29 June 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (8) , e70348
Open AccessReproducibility of Splanchnic Blood Flow Measured Using Phase‐Contrast MRI
Splanchnic vessel blood flow assessment can describe physiology or pathophysiology and also has clinical relevance for patients with altered abdominal blood flow, vascular neuropathy, or atherosclerotic conditions. Reliable and practicable methods for this assessment are needed. We assessed the reproducibility of non‐invasive phase‐contrast MRI (PC‐MRI) for measuring splanchnic blood flow and its feasibility for detecting postprandial blood flow changes. We included measurements from two groups of healthy individuals (Group A: n = 10; C: n = 10) and a group of patients with type 2 diabetes (B: n = 10) from randomized, single‐blind, placebo‐controlled studies, and assessed blood flow with 2D PC sequences (3 Tesla Siemens Biograph MRI and 3 Tesla Philips Achieva). Blood flow was measured in the arteria mesenterica superior, truncus coeliacus, arteria hepatica (Group A only), and vena portae hepatis over multiple days, with repeated scans each day to assess variability and reproducibility. To confirm detection of postprandial changes, nine repeated measurements were acquired during ingestion of 75‐g oral glucose tolerance test compared to water ingestion. Reproducibility was assessed by coefficient of variation (CoV) and limits of agreement with the mean (LoAM) using an extended Bland–Altman analysis. Blood flow in arteria mesenterica superior, truncus coeliacus, and vena portae hepatis demonstrated low intrasubject within session CoV (7%–22%) and intrasubject between session CoV (16%–26%). Blood flow in arteria hepatica had poorer CoV for both within sessions (12%) and between sessions (32%). Glucose ingestion induced a blood flow peak increase of 88% ± 52% in arteria mesenterica superior and 68% ± 36% in vena portae hepatis, both robustly detected, while no change was observed in the arteria hepatica or truncus coeliacus. In conclusion, PC‐MRI is a reproducible and feasible technique for measuring blood flow in arteria mesenterica superior, truncus coeliacus, and vena portae hepatis with the ability to detect postprandial changes. Trial Registration: ClinicalTrials.gov identifier: NCT05391581, NCT06426823, NCT06774807
- 23 February 2026
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 62, 102677
Prognostic value of bolus transit time and pulmonary blood volume in patients with nonischemic systolic heart failure
- 23 February 2026
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 62, 102677
Prognostic value of bolus transit time and pulmonary blood volume in patients with nonischemic systolic heart failure
- Open Access
- 14 November 2025
- Published by Elsevier in Journal of Clinical Densitometry
- Vol. 29 (1) , 101653
The Danish Nationwide osteoporosis cohort trials environment (NOCTE) – a DXA dataset for the 1900-1960 birth cohort
- 14 November 2025
- Published by Elsevier in Journal of Clinical Densitometry
- Vol. 29 (1) , 101653
Open AccessThe Danish Nationwide osteoporosis cohort trials environment (NOCTE) – a DXA dataset for the 1900-1960 birth cohort
- 30 May 2025
- Published by American Diabetes Association in Diabetes
- Vol. 74 (8) , 1355-1366
Glucose-Dependent Insulinotropic Polypeptide Is Involved in Postprandial Regulation of Splanchnic Blood Supply
Gastrointestinal hormones are essential for nutrient handling and regulation of glucose metabolism and may affect postprandial blood redistribution. In a randomized cross-over design in 10 healthy men, the involvement of glucose-dependent insulinotropic polypeptide (GIP) in splanchnic blood flow regulation was investigated using an infusion of GIP receptor antagonist (GIPR-An) GIP(3-30)NH2 during ingestion of oral glucose (75 g). In five separate sessions, we investigated GIP(1-42), GIPR-An with and without oral glucose, oral glucose alone, and a control saline infusion. Blood flow was assessed by phase contrast MRI, hepatic oxygen consumption by T2*, and plasma glucose, insulin, C-peptide, glucagon, GIP, GIPR-An, glucagon-like peptide 2, and bone metabolism markers by frequent blood sampling during all sessions. We found GIP(1-42) to stimulate blood flow in the superior mesenteric artery by ∼10% in the fasting state. Oral glucose alone increased mean blood flow in the superior mesenteric artery by ∼70% and portal vein by ∼40% of baseline. During oral glucose ingestion with concurrent infusion of GIPR-An, blood flow in the superior mesenteric artery was ∼22% lower. The hormone infusions did not affect blood flow in the hepatic artery and the celiac artery. Infusion of GIPR-An during oral glucose ingestion resulted in lower insulin secretion and higher levels of carboxy-terminal collagen crosslinks (bone resorption biomarker) compared with saline infusion, whereas glucagon levels were unaffected by both the injection of GIP and the GIPR-An infusions. We conclude that endogenous GIP increases splanchnic blood flow and contributes to postprandial intestinal hyperemia in healthy men. Article Highlights: Administration of the gut hormone glucose-dependent insulinotropic polypeptide (GIP) increases splanchnic blood flow. We investigated the role of endogenous GIP in splanchnic blood flow regulation using a receptor antagonist in humans. Oral glucose ingestion increased blood flow in the superior mesenteric artery by ∼70%, and the increase was significantly lower during concurrent infusion of the GIP receptor antagonist. Thus, endogenous GIP contributed ∼22% of the postprandial increase in superior mesenteric artery blood flow. We have identified a novel physiological aspect of vascular biology related to the GIP receptor in humans. Treatments targeting the GIP receptors are likely to affect splanchnic blood flow.
- 30 May 2025
- Published by American Diabetes Association in Diabetes
- Vol. 74 (8) , 1355-1366
Glucose-Dependent Insulinotropic Polypeptide Is Involved in Postprandial Regulation of Splanchnic Blood Supply
Gastrointestinal hormones are essential for nutrient handling and regulation of glucose metabolism and may affect postprandial blood redistribution. In a randomized cross-over design in 10 healthy men, the involvement of glucose-dependent insulinotropic polypeptide (GIP) in splanchnic blood flow regulation was investigated using an infusion of GIP receptor antagonist (GIPR-An) GIP(3-30)NH2 during ingestion of oral glucose (75 g). In five separate sessions, we investigated GIP(1-42), GIPR-An with and without oral glucose, oral glucose alone, and a control saline infusion. Blood flow was assessed by phase contrast MRI, hepatic oxygen consumption by T2*, and plasma glucose, insulin, C-peptide, glucagon, GIP, GIPR-An, glucagon-like peptide 2, and bone metabolism markers by frequent blood sampling during all sessions. We found GIP(1-42) to stimulate blood flow in the superior mesenteric artery by ∼10% in the fasting state. Oral glucose alone increased mean blood flow in the superior mesenteric artery by ∼70% and portal vein by ∼40% of baseline. During oral glucose ingestion with concurrent infusion of GIPR-An, blood flow in the superior mesenteric artery was ∼22% lower. The hormone infusions did not affect blood flow in the hepatic artery and the celiac artery. Infusion of GIPR-An during oral glucose ingestion resulted in lower insulin secretion and higher levels of carboxy-terminal collagen crosslinks (bone resorption biomarker) compared with saline infusion, whereas glucagon levels were unaffected by both the injection of GIP and the GIPR-An infusions. We conclude that endogenous GIP increases splanchnic blood flow and contributes to postprandial intestinal hyperemia in healthy men. Article Highlights: Administration of the gut hormone glucose-dependent insulinotropic polypeptide (GIP) increases splanchnic blood flow. We investigated the role of endogenous GIP in splanchnic blood flow regulation using a receptor antagonist in humans. Oral glucose ingestion increased blood flow in the superior mesenteric artery by ∼70%, and the increase was significantly lower during concurrent infusion of the GIP receptor antagonist. Thus, endogenous GIP contributed ∼22% of the postprandial increase in superior mesenteric artery blood flow. We have identified a novel physiological aspect of vascular biology related to the GIP receptor in humans. Treatments targeting the GIP receptors are likely to affect splanchnic blood flow.
- Open Access
- 20 February 2025
- Published by Elsevier in Osteoarthritis and Cartilage Open
- Vol. 7 (2) , 100583
Patients with unilateral patellofemoral pain have altered bone turnover in the painful knee compared to the pain-free knee at rest and after acute knee loading
- 20 February 2025
- Published by Elsevier in Osteoarthritis and Cartilage Open
- Vol. 7 (2) , 100583
Open AccessPatients with unilateral patellofemoral pain have altered bone turnover in the painful knee compared to the pain-free knee at rest and after acute knee loading
- Open Access
High agreement between lean mass assessed by Dual-Energy X-ray absorptiometry and Bioelectrical Impedance Analysis across the adult lifespan
Background: Bioelectrical impedance analysis (BIA) is considered a portable alternative to Dual-energy X-ray absorptiometry (DXA) when assessing deficient muscle mass, a major concern for older adults associated with increased risks of falls, fractures, disability, and mortality. However, several studies have demonstrated that BIA overestimates muscle mass in the older population and that estimates of muscle mass may depend on the BIA and DXA devices utilized. This study aims to describe the concordance between lean mass assessed by DXA and BIA across the adult population. Methods: This study is based on data from the Copenhagen Sarcopenia Study, a cross-sectional study of 1116 healthy participants aged 22-92 years with complete measurements of lean mass from both DXA (iDXA, GE Lunar) and BIA (Inbody 770). Relative appendicular lean mass (ALM) was calculated by normalizing ALM to height 2 to account for allometric differences in body size. Results: For the total cohort, linear regression models showed a strong correlation between BIA and DXA for ALM (R² = 0.95) and relative ALM (R² = 0.88). A small, yet consistent, bias of relative ALM values was observed where BIA measures were on average 0.25±0.50 kg/m 2 higher compared to measurements by DXA. The bias was consistent across age groups with a mean difference in relative ALM of 0.24±0.50 kg/m 2 and 0.26±0.49 kg/m 2 for younger and older participants, respectively. Conclusion: BIA is a reliable alternative to DXA for assessing lean mass, in both younger and older adults. The findings indicate that with simple correction equations for ALM and relative ALM, BIA can be a practical and accessible tool in clinical settings where DXA is unavailable. These equations make BIA particularly useful for diagnosing sarcopenia in a clinical setting, allowing for early detection and management regardless of age. Key messages: Bioelectrical impedance analysis (BIA) is considered a portable alternative to Dual-energy X-ray absorptiometry (DXA) when assessing low muscle mass; a major concern for older adults which is associated with increased risks of falls, fractures, disability, and mortality. However, several studies have demonstrated that BIA overestimates muscle mass in the older population and estimates of muscle mass may depend on the BIA and DXA devices utilized. By applying the models of regression equations developed in this study, clinicians can improve the accuracy of BIA measurements, making BIA a practical alternative to DXA in clinical settings where DXA is not accessible. These findings are especially relevant for the early detection and management of sarcopenia in older adults, allowing for timely interventions to preserve muscle function and reduce the risk of adverse health outcomes.
Open AccessHigh agreement between lean mass assessed by Dual-Energy X-ray absorptiometry and Bioelectrical Impedance Analysis across the adult lifespan
Background: Bioelectrical impedance analysis (BIA) is considered a portable alternative to Dual-energy X-ray absorptiometry (DXA) when assessing deficient muscle mass, a major concern for older adults associated with increased risks of falls, fractures, disability, and mortality. However, several studies have demonstrated that BIA overestimates muscle mass in the older population and that estimates of muscle mass may depend on the BIA and DXA devices utilized. This study aims to describe the concordance between lean mass assessed by DXA and BIA across the adult population. Methods: This study is based on data from the Copenhagen Sarcopenia Study, a cross-sectional study of 1116 healthy participants aged 22-92 years with complete measurements of lean mass from both DXA (iDXA, GE Lunar) and BIA (Inbody 770). Relative appendicular lean mass (ALM) was calculated by normalizing ALM to height 2 to account for allometric differences in body size. Results: For the total cohort, linear regression models showed a strong correlation between BIA and DXA for ALM (R² = 0.95) and relative ALM (R² = 0.88). A small, yet consistent, bias of relative ALM values was observed where BIA measures were on average 0.25±0.50 kg/m 2 higher compared to measurements by DXA. The bias was consistent across age groups with a mean difference in relative ALM of 0.24±0.50 kg/m 2 and 0.26±0.49 kg/m 2 for younger and older participants, respectively. Conclusion: BIA is a reliable alternative to DXA for assessing lean mass, in both younger and older adults. The findings indicate that with simple correction equations for ALM and relative ALM, BIA can be a practical and accessible tool in clinical settings where DXA is unavailable. These equations make BIA particularly useful for diagnosing sarcopenia in a clinical setting, allowing for early detection and management regardless of age. Key messages: Bioelectrical impedance analysis (BIA) is considered a portable alternative to Dual-energy X-ray absorptiometry (DXA) when assessing low muscle mass; a major concern for older adults which is associated with increased risks of falls, fractures, disability, and mortality. However, several studies have demonstrated that BIA overestimates muscle mass in the older population and estimates of muscle mass may depend on the BIA and DXA devices utilized. By applying the models of regression equations developed in this study, clinicians can improve the accuracy of BIA measurements, making BIA a practical alternative to DXA in clinical settings where DXA is not accessible. These findings are especially relevant for the early detection and management of sarcopenia in older adults, allowing for timely interventions to preserve muscle function and reduce the risk of adverse health outcomes.
- Open Access
- 24 July 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (15) , 1590
Automated Quantitative Image-Derived Input Function for the Estimation of Cerebral Blood Flow Using Oxygen-15-Labelled Water on a Long-Axial Field-of-View PET/CT Scanner
The accurate estimation of the tracer arterial blood concentration is crucial for reliable quantitative kinetic analysis in PET. In the current work, we demonstrate the automatic extraction of an image-derived input function (IDIF) from a CT AI-based aorta segmentation subsequently resliced to a dynamic PET series acquired on a Siemens Vision Quadra long-axial field of view scanner in 10 human subjects scanned with [15O]H2O. We demonstrate that the extracted IDIF is quantitative and in excellent agreement with a delay- and dispersion-corrected sampled arterial input function (AIF). Perfusion maps in the brain are calculated and compared from the IDIF and AIF, respectively, showed a high degree of correlation. The results demonstrate the possibility of defining a quantitatively correct IDIF compared with AIFs from the new-generation high-sensitivity and high-time-resolution long-axial field-of-view PET/CT scanners.
- 24 July 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (15) , 1590
Open AccessAutomated Quantitative Image-Derived Input Function for the Estimation of Cerebral Blood Flow Using Oxygen-15-Labelled Water on a Long-Axial Field-of-View PET/CT Scanner
The accurate estimation of the tracer arterial blood concentration is crucial for reliable quantitative kinetic analysis in PET. In the current work, we demonstrate the automatic extraction of an image-derived input function (IDIF) from a CT AI-based aorta segmentation subsequently resliced to a dynamic PET series acquired on a Siemens Vision Quadra long-axial field of view scanner in 10 human subjects scanned with [15O]H2O. We demonstrate that the extracted IDIF is quantitative and in excellent agreement with a delay- and dispersion-corrected sampled arterial input function (AIF). Perfusion maps in the brain are calculated and compared from the IDIF and AIF, respectively, showed a high degree of correlation. The results demonstrate the possibility of defining a quantitatively correct IDIF compared with AIFs from the new-generation high-sensitivity and high-time-resolution long-axial field-of-view PET/CT scanners.
- Open Access
- 29 December 2023
- Published by MDPI AG in Diagnostics
- Vol. 14 (1) , 81
Multimodality Imaging in Cranial Giant Cell Arteritis: First Experience with High-Resolution T1-Weighted 3D Black Blood without Contrast Enhancement Magnetic Resonance Imaging
In order to support or refute the clinical suspicion of cranial giant cell arteritis (GCA), a supplemental imaging modality is often required. High-resolution black blood Magnetic Resonance Imaging (BB MRI) techniques with contrast enhancement can visualize artery wall inflammation in GCA. We compared findings on BB MRI without contrast enhancement with findings on 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/low-dose computed tomography (2-[18F]FDG PET/CT) in ten patients suspected of having GCA and in five control subjects who had a 2-[18F]FDG PET/CT performed as a routine control for malignant melanoma. BB MRI was consistent with 2-[18F]FDG PET/CT in 10 out of 10 cases in the group with suspected GCA. In four out of five cases in the control group, the BB MRI was consistent with 2-[18F]FDG PET/CT. In this small population, BB MRI without contrast enhancement shows promising performance in the diagnosis of GCA, and might be an applicable imaging modality in patients.
- 29 December 2023
- Published by MDPI AG in Diagnostics
- Vol. 14 (1) , 81
Open AccessMultimodality Imaging in Cranial Giant Cell Arteritis: First Experience with High-Resolution T1-Weighted 3D Black Blood without Contrast Enhancement Magnetic Resonance Imaging
In order to support or refute the clinical suspicion of cranial giant cell arteritis (GCA), a supplemental imaging modality is often required. High-resolution black blood Magnetic Resonance Imaging (BB MRI) techniques with contrast enhancement can visualize artery wall inflammation in GCA. We compared findings on BB MRI without contrast enhancement with findings on 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/low-dose computed tomography (2-[18F]FDG PET/CT) in ten patients suspected of having GCA and in five control subjects who had a 2-[18F]FDG PET/CT performed as a routine control for malignant melanoma. BB MRI was consistent with 2-[18F]FDG PET/CT in 10 out of 10 cases in the group with suspected GCA. In four out of five cases in the control group, the BB MRI was consistent with 2-[18F]FDG PET/CT. In this small population, BB MRI without contrast enhancement shows promising performance in the diagnosis of GCA, and might be an applicable imaging modality in patients.
- Open Access
- 11 April 2023
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 43 (4) , 207-210
Multiparametric magnetic resonance imaging: A robust tool to test pathogenesis and pathophysiology behind nephropathy in humans
Chronic kidney disease (CKD) is a major population disease. In diabetes as well as hypertension, kidney disease is one of the most serious complications. Recent research has demonstrated that chronic hypoxia is a key actor in the pathogenesis of CKD. In this review, we focus on how functional magnetic resonance imaging (fMRI) techniques can shed light on pathogenetic mechanisms and monitor new treatments aimed at preventing or ameliorating the disease. Multiparametric MRI techniques can measure changes in renal artery flow, tissue perfusion, and oxygenation repetitively over short time periods, enabling high time resolution. Furthermore, renal fibrosis can be quantified noninvasively by MRI diffusion tensor imaging, and techniques are upcoming to measure renal oxygen consumption. These techniques are all radiation and contrast‐free.We briefly present data, demonstrating that fMRI techniques can play a major role in future research in CKD, and possibly also in daily clinical practice.
- 11 April 2023
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 43 (4) , 207-210
Open AccessMultiparametric magnetic resonance imaging: A robust tool to test pathogenesis and pathophysiology behind nephropathy in humans
Chronic kidney disease (CKD) is a major population disease. In diabetes as well as hypertension, kidney disease is one of the most serious complications. Recent research has demonstrated that chronic hypoxia is a key actor in the pathogenesis of CKD. In this review, we focus on how functional magnetic resonance imaging (fMRI) techniques can shed light on pathogenetic mechanisms and monitor new treatments aimed at preventing or ameliorating the disease. Multiparametric MRI techniques can measure changes in renal artery flow, tissue perfusion, and oxygenation repetitively over short time periods, enabling high time resolution. Furthermore, renal fibrosis can be quantified noninvasively by MRI diffusion tensor imaging, and techniques are upcoming to measure renal oxygen consumption. These techniques are all radiation and contrast‐free.We briefly present data, demonstrating that fMRI techniques can play a major role in future research in CKD, and possibly also in daily clinical practice.