James Paul Rouse
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
James Paul Rouse has a total of 106 co-authors. Here are the top co-authors by number of shared publications:
- Christopher J. Hyde
University of Nottingham
11 shared publications - Wei Sun
Faculty of Engineering, University of Nottingham, Nottingham, UK
8 shared publications - Seamus D. Garvey
University of Nottingham
6 shared publications T. H. Hyde
Department of Mechanical, Materials and Manufacturing Engineering, University of Nottingham, Nottingham, UK
6 shared publications- Andrew Morris
EDF Energy, Central Technical Organization, Coal and Gas Operations, West Burton A Power Station, Retford, Nottinghamshire, U.K.
5 shared publications C.J. Hyde
5 shared publications
Latest Publications
- Open Access
- 29 October 2026
- Published by Taylor & Francis in European Journal of Materials
- p. 1-15
Statistical Overlay of CFRP Strain Fields from Digital Image Correlation for Finite Element Analysis Validation
1 IntroductionAerostructures must possess high strength and damage tolerance to withstand aerodynamic and extreme crashworthiness loading conditions [1], while simultaneously minimising structural ...
- 29 October 2026
- Published by Taylor & Francis in European Journal of Materials
- p. 1-15
Open AccessStatistical Overlay of CFRP Strain Fields from Digital Image Correlation for Finite Element Analysis Validation
1 IntroductionAerostructures must possess high strength and damage tolerance to withstand aerodynamic and extreme crashworthiness loading conditions [1], while simultaneously minimising structural ...
- Open Access
- 2 June 2026
- Published by Elsevier in SSRN Electronic Journal
Computational fluid dynamics-finite element thermomechanical assessment of the impact of viscoelastic effects on the inelastic strain accumulation in a 316 stainless steel power plant steam header
Flexible two-shifting operation of thermal power plants subjects high-temperature components to repeated thermal ramps, dwell periods, and rapid shutdowns, intensifying thermomechanical loading.This study investigates the influence of spatially and temporally varying convective heat transfer coefficients (HTCs) on the structural response of a Type 316 stainless steel superheater outlet header. A wall-resolved CFD framework employing the SST-𝑘𝜔 turbulence model is used to extract local HTC distributions at representative operating points. The approach is validated against the WATLON Tjunction experiment and shown to achieve mesh independent predictions. Shell-conduction modelling is adopted to retain fluid-solid thermal coupling while avoiding the computational expense of full conjugate heat transfer. The CFD results demonstrate pronounced spatial non-uniformity in HTC around stub-shell junctions, with local peak values exceeding average shell HTCs by up to a factor of 5.5. Rapid shutdown produces the most severe transient, with mean HTC reductions exceeding 2000 W/m2K within 10 minutes. These spatially and temporally resolved HTCs are mapped to a thermomechanical finite element model incorporating a viscoelastic constitutive formulation. Comparison with conventional uniform HTC assumptions shows negligible differences during steady operation but significant divergence during shutdown. Local stress predictions differ by more than 250%, while accumulated inelastic strain differs by up to 50% circumferentially. The findings demonstrate that uniform thermal boundary conditions can misrepresent both peak stress localisation and long-term strain accumulation. CFD-informed HTC fields are therefore essential for reliable structural integrity assessment of headers operating under flexible loading regimes.
- 2 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessComputational fluid dynamics-finite element thermomechanical assessment of the impact of viscoelastic effects on the inelastic strain accumulation in a 316 stainless steel power plant steam header
Flexible two-shifting operation of thermal power plants subjects high-temperature components to repeated thermal ramps, dwell periods, and rapid shutdowns, intensifying thermomechanical loading.This study investigates the influence of spatially and temporally varying convective heat transfer coefficients (HTCs) on the structural response of a Type 316 stainless steel superheater outlet header. A wall-resolved CFD framework employing the SST-𝑘𝜔 turbulence model is used to extract local HTC distributions at representative operating points. The approach is validated against the WATLON Tjunction experiment and shown to achieve mesh independent predictions. Shell-conduction modelling is adopted to retain fluid-solid thermal coupling while avoiding the computational expense of full conjugate heat transfer. The CFD results demonstrate pronounced spatial non-uniformity in HTC around stub-shell junctions, with local peak values exceeding average shell HTCs by up to a factor of 5.5. Rapid shutdown produces the most severe transient, with mean HTC reductions exceeding 2000 W/m2K within 10 minutes. These spatially and temporally resolved HTCs are mapped to a thermomechanical finite element model incorporating a viscoelastic constitutive formulation. Comparison with conventional uniform HTC assumptions shows negligible differences during steady operation but significant divergence during shutdown. Local stress predictions differ by more than 250%, while accumulated inelastic strain differs by up to 50% circumferentially. The findings demonstrate that uniform thermal boundary conditions can misrepresent both peak stress localisation and long-term strain accumulation. CFD-informed HTC fields are therefore essential for reliable structural integrity assessment of headers operating under flexible loading regimes.
- 1 September 2023
- Published by Elsevier in Tribology International
- Vol. 189
Investigation into the effects of abradable evolution and ovalisation during blade-casing interactions
- 1 September 2023
- Published by Elsevier in Tribology International
- Vol. 189
Investigation into the effects of abradable evolution and ovalisation during blade-casing interactions
- Open Access
Comparative Analysis of Isochoric and Isobaric Adiabatic Compressed Air Energy Storage
Adiabatic Compressed Air Energy Storage (ACAES) is regarded as a promising, grid scale, medium-to-long duration energy storage technology. In ACAES, the air storage may be isochoric (constant volume) or isobaric (constant pressure). Isochoric storage, wherein the internal pressure cycles between an upper and lower limit as the system charges and discharges is mechanically simpler, however, it leads to undesirable thermodynamic consequences which are detrimental to the ACAES overall performance. Isobaric storage can be a valuable alternative: the storage volume varies to offset the pressure and temperature changes that would otherwise occur as air mass enters or leaves the high-pressure storage. In this paper we develop a thermodynamic model based on expected ACAES and existing CAES system features to compare the effects of isochoric and isobaric storage. Importantly, off-design compressor performance due to the sliding storage pressure is included by using a second degree polynomial fit for the isentropic compressor efficiency. For our modelled systems, the isobaric system round-trip efficiency (RTE) reaches 61.5%. The isochoric system achieves 57.8% even when no compressor off-design performance decrease is taken into account. This fact is associated to inherent losses due to throttling and mixing of heat stored at different temperatures. In our base-case scenario where the isentropic compressor efficiency varies between and , the isochoric system RTE is approximately 10% lower than the isobaric. These results indicate that isobaric storage for CAES is worth further development. We suggest that subsequent work investigate the exergy flows as well as the scalability challenges with isobaric storage mechanisms.Open AccessComparative Analysis of Isochoric and Isobaric Adiabatic Compressed Air Energy Storage
Adiabatic Compressed Air Energy Storage (ACAES) is regarded as a promising, grid scale, medium-to-long duration energy storage technology. In ACAES, the air storage may be isochoric (constant volume) or isobaric (constant pressure). Isochoric storage, wherein the internal pressure cycles between an upper and lower limit as the system charges and discharges is mechanically simpler, however, it leads to undesirable thermodynamic consequences which are detrimental to the ACAES overall performance. Isobaric storage can be a valuable alternative: the storage volume varies to offset the pressure and temperature changes that would otherwise occur as air mass enters or leaves the high-pressure storage. In this paper we develop a thermodynamic model based on expected ACAES and existing CAES system features to compare the effects of isochoric and isobaric storage. Importantly, off-design compressor performance due to the sliding storage pressure is included by using a second degree polynomial fit for the isentropic compressor efficiency. For our modelled systems, the isobaric system round-trip efficiency (RTE) reaches 61.5%. The isochoric system achieves 57.8% even when no compressor off-design performance decrease is taken into account. This fact is associated to inherent losses due to throttling and mixing of heat stored at different temperatures. In our base-case scenario where the isentropic compressor efficiency varies between and , the isochoric system RTE is approximately 10% lower than the isobaric. These results indicate that isobaric storage for CAES is worth further development. We suggest that subsequent work investigate the exergy flows as well as the scalability challenges with isobaric storage mechanisms. - Open Access
- 16 January 2023
- Published by Elsevier in Materials & Design
- Vol. 226
Multi-scale modelling of the mechanical behaviour of a CoNiCrAlY bond coat alloy during small punch testing
- 16 January 2023
- Published by Elsevier in Materials & Design
- Vol. 226
Open AccessMulti-scale modelling of the mechanical behaviour of a CoNiCrAlY bond coat alloy during small punch testing
- Open Access
- 5 December 2022
- Published by Springer Nature in Experimental Mechanics
- Vol. 63 (3) , 429-443
The Estimation of Taylor-Quinney Coefficients Using Small Ring Specimens
Background: The use of the Taylor-Quinney coefficient for introducing a thermal dissipation term into material models relies on understanding its dependencies. These are usually determined through extensive experimentation, wherein temperature variations are monitored in a test piece during mechanical loading. Objective: This study aims to reduce the cost and time necessary to determining the dependencies of the Taylor-Quinney coefficient by proposing a novel small specimen inverse testing method and demonstrating its use on aluminium alloy 7175. Methods: The method proposed is based on mechanical testing of a novel small ring specimen in parallel with FEA simulations. In the experiments, small rings of 7175-T7351 aluminium alloy, 20 mm in outer diameter, were loaded between two pins for different pin displacement rates (namely 1, 1.5 and 2 mm/s) at room temperature and the local specimen temperature field was monitored using an infra-red thermal camera. Fully coupled thermal-mechanical simulations of the tests were performed using a range of Taylor-Quinney coefficients, and the resulting temperature evolutions compared to the experimental results in order to determine appropriate coefficient values for the material. Results: The method presented shows good repeatability and allows for clear observation of thermal dissipation. Taylor-Quinney values ranging 0.51-0.59 are reported for the 7175 alloy, in line with values reported in the literature for similar alloys. Density, specific heat capacity and thermal conductivity, fundamental thermal material properties necessary for the simulations, are also reported for the alloy. Conclusions: The method detailed shows promise for determining Taylor-Quinney coefficients in a wide range of experimental conditions and is proposed as a cheap and fast alternative to full-scale specimen testing of Taylor-Quinney coefficients. Taylor-Quinney values obtained for 7175 aluminium are shown to be much lower than the value of 0.9 often proposed for materials.
- 5 December 2022
- Published by Springer Nature in Experimental Mechanics
- Vol. 63 (3) , 429-443
Open AccessThe Estimation of Taylor-Quinney Coefficients Using Small Ring Specimens
Background: The use of the Taylor-Quinney coefficient for introducing a thermal dissipation term into material models relies on understanding its dependencies. These are usually determined through extensive experimentation, wherein temperature variations are monitored in a test piece during mechanical loading. Objective: This study aims to reduce the cost and time necessary to determining the dependencies of the Taylor-Quinney coefficient by proposing a novel small specimen inverse testing method and demonstrating its use on aluminium alloy 7175. Methods: The method proposed is based on mechanical testing of a novel small ring specimen in parallel with FEA simulations. In the experiments, small rings of 7175-T7351 aluminium alloy, 20 mm in outer diameter, were loaded between two pins for different pin displacement rates (namely 1, 1.5 and 2 mm/s) at room temperature and the local specimen temperature field was monitored using an infra-red thermal camera. Fully coupled thermal-mechanical simulations of the tests were performed using a range of Taylor-Quinney coefficients, and the resulting temperature evolutions compared to the experimental results in order to determine appropriate coefficient values for the material. Results: The method presented shows good repeatability and allows for clear observation of thermal dissipation. Taylor-Quinney values ranging 0.51-0.59 are reported for the 7175 alloy, in line with values reported in the literature for similar alloys. Density, specific heat capacity and thermal conductivity, fundamental thermal material properties necessary for the simulations, are also reported for the alloy. Conclusions: The method detailed shows promise for determining Taylor-Quinney coefficients in a wide range of experimental conditions and is proposed as a cheap and fast alternative to full-scale specimen testing of Taylor-Quinney coefficients. Taylor-Quinney values obtained for 7175 aluminium are shown to be much lower than the value of 0.9 often proposed for materials.
- Open Access
- 23 August 2022
- Published by Wiley in International Journal for Numerical Methods in Engineering
- Vol. 123 (23) , 5826-5853
A probabilistic data assimilation framework to reconstruct finite element error fields from sparse error estimates: Application to sub‐modeling
- 23 August 2022
- Published by Wiley in International Journal for Numerical Methods in Engineering
- Vol. 123 (23) , 5826-5853
Open AccessA probabilistic data assimilation framework to reconstruct finite element error fields from sparse error estimates: Application to sub‐modeling
- Open Access
Analysis of a Wind-Driven Air Compression System Utilising Underwater Compressed Air Energy Storage
The increasing push for renewable penetration into electricity grids will inevitably lead to an increased requirement for grid-scale energy storage at multiple time scales. It will, necessarily, lead to a higher proportion of the total energy consumed having been passed through storage. Offshore wind is a key technology for renewable penetration, and the co-location of energy storage with this wind power provides significant benefits. A novel generation-integrated energy storage system is described here in the form of a wind-driven air compressor feeding underwater compressed air energy storage. A direct drive compressor would require very high intake swept volumes. To overcome this difficulty, some prior compression is introduced. This paper discusses the constituent technologies for this concept, as well as the various configurations that it might take and the logic behind operating it. Special consideration has been given to the differences resulting from utilising a near-isothermal wind-driven compressor versus a near-adiabatic one. Multiple iterations of the system have been simulated. This has been done using a price-matching algorithm to optimise the system operation and using volumetric air flow rates to calculate exergy flow. Simulated operation has been performed for a year of real wind and electricity price data. This work has been performed in order to clarify the relationships between several key parameters in the system, including pressure and work ratios, volumetric flowrates, storage costs and profit rates. An additional objective of this paper was to determine whether the system has the potential for economic viability in some future energy grid, especially when compared with alternative wind and energy storage solutions. The results of the simulation indicated that, with proper sizing, the system might perform competitively with these alternatives. Maximum one-year return on investment values of 9.8% for the isothermal case and 13% for the adiabatic case were found. These maxima were reached with ~15–20 h of output storage. In all cases, it was found that maximising the power of the wind-driven compressor compared with the initial compressor was favourable.
Open AccessAnalysis of a Wind-Driven Air Compression System Utilising Underwater Compressed Air Energy Storage
The increasing push for renewable penetration into electricity grids will inevitably lead to an increased requirement for grid-scale energy storage at multiple time scales. It will, necessarily, lead to a higher proportion of the total energy consumed having been passed through storage. Offshore wind is a key technology for renewable penetration, and the co-location of energy storage with this wind power provides significant benefits. A novel generation-integrated energy storage system is described here in the form of a wind-driven air compressor feeding underwater compressed air energy storage. A direct drive compressor would require very high intake swept volumes. To overcome this difficulty, some prior compression is introduced. This paper discusses the constituent technologies for this concept, as well as the various configurations that it might take and the logic behind operating it. Special consideration has been given to the differences resulting from utilising a near-isothermal wind-driven compressor versus a near-adiabatic one. Multiple iterations of the system have been simulated. This has been done using a price-matching algorithm to optimise the system operation and using volumetric air flow rates to calculate exergy flow. Simulated operation has been performed for a year of real wind and electricity price data. This work has been performed in order to clarify the relationships between several key parameters in the system, including pressure and work ratios, volumetric flowrates, storage costs and profit rates. An additional objective of this paper was to determine whether the system has the potential for economic viability in some future energy grid, especially when compared with alternative wind and energy storage solutions. The results of the simulation indicated that, with proper sizing, the system might perform competitively with these alternatives. Maximum one-year return on investment values of 9.8% for the isothermal case and 13% for the adiabatic case were found. These maxima were reached with ~15–20 h of output storage. In all cases, it was found that maximising the power of the wind-driven compressor compared with the initial compressor was favourable.
- Open Access
Short-, Medium-, and Long-Duration Energy Storage in a 100% Renewable Electricity Grid: A UK Case Study
Energy storage will be required over a wide range of discharge durations in future zero-emission grids, from milliseconds to months. No single technology is well suited for the complete range. Using 9 years of UK data, this paper explores how to combine different energy storage technologies to minimize the total cost of electricity (TCoE) in a 100% renewable-based grid. Hydrogen, compressed air energy storage (CAES) and Li-ion batteries are considered short-, medium-, and long-duration energy stores, respectively. This paper analyzes different system configurations to find the one leading to the lowest overall cost. Results suggest that the UK will need a storage capacity of ~66.6 TWh to decarbonize its grid. This figure considers a mix of 85% wind + 15% solar-photovoltaics, and 15% over-generation. The optimum distribution of the storage capacity is: 55.3 TWh in hydrogen, 11.1 TWh in CAES and 168 GWh in Li-ion batteries. More than 60% of all energy emerging from storage comes from medium-duration stores. Based on current costs, the storage capacity required represents an investment of ~£172.6 billion, or approximately 8% of the country’s GDP. With this optimum system configuration, a TCoE of ~75.6 £/MWh is attained.
Open AccessShort-, Medium-, and Long-Duration Energy Storage in a 100% Renewable Electricity Grid: A UK Case Study
Energy storage will be required over a wide range of discharge durations in future zero-emission grids, from milliseconds to months. No single technology is well suited for the complete range. Using 9 years of UK data, this paper explores how to combine different energy storage technologies to minimize the total cost of electricity (TCoE) in a 100% renewable-based grid. Hydrogen, compressed air energy storage (CAES) and Li-ion batteries are considered short-, medium-, and long-duration energy stores, respectively. This paper analyzes different system configurations to find the one leading to the lowest overall cost. Results suggest that the UK will need a storage capacity of ~66.6 TWh to decarbonize its grid. This figure considers a mix of 85% wind + 15% solar-photovoltaics, and 15% over-generation. The optimum distribution of the storage capacity is: 55.3 TWh in hydrogen, 11.1 TWh in CAES and 168 GWh in Li-ion batteries. More than 60% of all energy emerging from storage comes from medium-duration stores. Based on current costs, the storage capacity required represents an investment of ~£172.6 billion, or approximately 8% of the country’s GDP. With this optimum system configuration, a TCoE of ~75.6 £/MWh is attained.