XYXiao Yang

Xiao Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiao Yang has a total of 99 co-authors. Here are the top co-authors by number of shared publications:

  • Jianshu Li

    College of Polymer Science and Engineering National Key Laboratory of Advanced Polymer Materials Sichuan University Chengdu China

    13 shared publications
  • Xinyuan Xu

    College of Polymer Science and Engineering State Key Laboratory of Polymer Materials Engineering Sichuan University No. 24, South Section One of Yinhuan Road Chengdu 610065 P. R. China

    7 shared publications
  • Chunmei Ding

    College of Polymer Science and Engineering, National Key Laboratory of Advanced Polymer Materials, Sichuan University, Chengdu, 610065, P. R. China

    6 shared publications
  • Libang He

    State Key Laboratory of Oral Diseases National Clinical Research Center for Oral Diseases Dept. of Cariology and Endodonics West China Hospital of Stomatology, Sichuan University, China

    5 shared publications
  • Jiyao Li

    West China Hospital of Stomatology, Sichuan University

    4 shared publications
  • Bo Yang

    Department of Biomedical Polymers and Artificial Organs, College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, No. 24, First Section of South Yihuan Road, Chengdu 610065, P. R. China

    3 shared publications

Latest Publications

  • Open Access

    Advancements and Critical Evaluation of Wearable and Implantable Sensor Technologies in Joint Disease Management

    by Fei Jin, Liangbin Zhou, Haoyue Luo, Yuwei Zhang, Xiao Yang, Yichi Zhang, Zhong Alan Li, David J. Hunter

    Joint diseases and injuries substantially impair daily activities. Continuous monitoring of joint function offers a powerful approach to assessing joint health and guiding therapeutic interventions. This Review begins with the pathophysiology of joint diseases and critically examines flexible bioelectronic sensors designed to monitor distinct physiological features associated with osteoarthritis, rheumatoid arthritis, gouty arthritis, and ligament injuries. We discuss the sensing mechanisms, developmental stages, and challenges in clinical translation of these devices. Currently, inertial sensing is the only technology that has entered clinical evaluation; most other sensors remain at an early developmental stage, with a considerable gap yet to be bridged before clinical application. Advances in flexible electronics, self‑powered operation and wireless transmission are steering these sensors toward personalized home‑based healthcare monitoring. However, the lack of standardized data protocols, low system integration, unverified long‑term reliability, and insufficient clinical sample sizes constitute major barriers to translation. Finally, we outline the functional requirements for next‑generation sensors designed for continuous, long‑term monitoring of joint diseases: future systems should prioritize high precision with unified data standards, high integration with robust fatigue resistance, and multimodality with proven biosafety.

  • Top Cited Papers

    Nanoemulsion modular assembly for the synthesis of functional mesoporous nanomaterials

    by Liang Peng, Huarong Peng, Yongjiu Yuan, Yuxin Song, Xiao Yang, Pengcheng Sun, Yingying Yin, Steven Wang, Zhengxiao Guo, Dongyuan Zhao, et al.


  • Open Access

    A conformal piezoelectric microsystem for demographic-adaptive and calibration-free cuffless blood pressure monitoring

    by Cunman Liang, Zhou Jiang, Shirong Qiu, Lei Zhao, Xinxin Mao, Xiao Yang, Yuanting Zhang, Ni Zhao

    Frequent recalibration poses a significant challenge to the accuracy and reliability of current cuffless blood pressure (BP) monitoring devices, especially in long-term use. Here, we introduce a conformal and stretchable piezoelectric microsystem (CSPM) combined with a demographic-adaptive BP estimation model, enabling calibration-free, continuous BP tracking with accuracy comparable to cuff-based medical devices. The CSPM integrates an ultrasound transducer array for vessel diameter waveform recording and two pulse waveform (PWF) sensors with cavity-enhanced piezoelectric thin films for precise pulse wave detection, enabling simultaneous measurement of pulse wave velocity (PWV) and vessel diameter in the same localized vascular area. Leveraging real-time PWV and vessel diameter inputs, our BP algorithm employs a demographic feature learning module for broad population applicability and a time decay compensation strategy to address minor slippage and measurement shifts, enabling the acquisition of individual BP values without calibration. This innovation effectively addresses key challenges in population recalibration and multimodal integration, enabling stable long-term continuous BP tracking, achieving mean absolute errors of 5.22 mmHg for systolic BP and 4.57 mmHg for diastolic BP.


  • Open Access

    Role of chemistry in nature-inspired skin adhesives

    by Xiao Yang, Xiaonan Liu, Yeung Yeung Chau, Xuezhi Qin, Hong Zhu, Liang Peng, Kannie W. Y. Chan, Zuankai Wang

    This review examines nature-inspired skin adhesives that exhibit strong wet adhesion and high biocompatibility for next-generation wearable technologies, focusing on the chemical and physical mechanisms, design, and applications.


  • Detecting human articular cartilage degeneration in its early stage with polarization-sensitive optical coherence tomography

    by Xin Zhou, Felipe Eltit, Xiao Yang, Sina Maloufi, Hanadi Alousaimi, Qihao Liu, Lin Huang, Rizhi Wang, Shuo Tang

    Detecting articular cartilage (AC) degeneration in its early stage plays a critical role in the diagnosis and treatment of osteoarthritis (OA). Polarization-sensitive optical coherence tomography (PS-OCT) is sensitive to the alteration and disruption of collagen organization that happens during OA progression. This study proposes an effective OA evaluating method based on PS-OCT imaging. A slope-based analysis is applied on the phase retardation images to segment articular cartilage into three zones along the depth direction. The boundaries and birefringence coefficients (BRCs) of each zone are quantified. Two parameters, namely phase homogeneity index (PHI) and zonal distinguishability (Dz), are further developed to quantify the fluctuation within each zone and the zone-to-zone variation of the tissue birefringence properties. The PS-OCT based evaluating method then combines PHI and Dz to provide a G PS score for the severity of OA. The proposed method is applied to human hip joint samples and the results are compared with the grading by histology images. The G PS score shows very strong statistical significance in differentiating different stages of OA. Compared to using the BRC of each zone or a single BRC for the entire depth, the G PS score shows great improvement in differentiating early-stage OA. The proposed method is shown to have great potential to be developed as a clinical tool for detecting OA.


  • A Universal and Ultrastable Mineralization Coating Bioinspired from Biofilms

    by Xiao Yang, Zhenhua Li, Hong Xiao, Ning Wang, Yanpu Li, Xinyuan Xu, Zhijun Chen, Hong Tan, Jianshu Li

    A simple and universal method for manufacturing a mineralization coating on various surfaces is developed using a biofilm‐based material obtained from engineered curli nanofibers. The amyloid protein (CsgA) is the main proteinaceous component in the Escherichia coli (E. coli) biofilm, which can withstand detergents in the harsh environment. The peptide sequence DDDEEK is bioinspired from salivary acquired pellicles in the dental plaque biofilm, having a strong ability to absorb mineral ions and induce the formation of biominerals. The bioinspired coating is successfully secreted by the engineered E. coli, which is transformed with a recombinant plasmid for expression with T7 promoter (PET), namely PET‐22b‐CsgA‐DDDEEK plasmid. The uniform coating can bear shear force and stay on virtually any type of material surface for at least one month. Moreover, the coated slices had a good mineralization performance and better stability than hydroxyapatite (HA)‐spray slices. Furthermore, MG63 cells on the bioactive HA layer induced by the coating possess a better growth capacity than those on the commercial product Matrigel. The animal experiment results suggest that the coated Ti6Al4V screws with induced HA present better osteogenicity and osseointegration than HA‐sprayed screws after 12 weeks, as well as no extra immunogenicity. Thus, the coating is highly promising for biomedical applications.


  • Bioinspired heptapeptides as functionalized mineralization inducers with enhanced hydroxyapatite affinity

    by Yuebo Liu, Chunmei Ding, Libang He, Xiao Yang, Yaping Gou, Xinyuan Xu, Yanpeng Liu, Changsheng Zhao, Jianshu Li, Jiyao Li

    The regeneration of mineral crystals under physiological conditions is an efficient way to repair defects in hard tissues. To achieve robust mineralization on surfaces such as the tooth enamel, an inducer requires strong affinity with the substrates and should be able to induce mineralization. Thus far, most studies used a single molecule containing two components to realize the above functions separately, which might be troublesome to synthesize and purify. In this work, inspired by the statherin in the salivary acquired pellicle, we designed a simple peptide sequence, Asp–Asp–Asp–Glu–Glu–Lys–Cys (peptide-7), to accomplish the dual tasks of adsorption and mineralization on enamel surfaces. We speculate the calcium binding ability of the negatively charged carboxylic acid groups in the peptide itself contributes to the dual functions of peptide-7. In vitro and in vivo experiments demonstrated its excellent repair effect on enamel as compared to fluoride. More importantly, due to the strong affinity between peptides and hydroxyapatite, a compact mineralized crystal layer and a strong adhesion between the regenerated minerals and the bottom substrates were observed, similar to the effect induced by fluoride. This work sheds light on the interaction mechanism between peptide-7 and minerals. In addition, since it is safer than fluoride, peptide-7 may have potential applications in the repair of other hard tissues and the functionalization of biomaterials.


  • Antibacterial and anti-biofouling coating on hydroxyapatite surface based on peptide-modified tannic acid

    by Xiao Yang, Pei Huang, Haihuan Wang, Shuang Cai, Yixue Liao, Ziqin Mo, Xinyuan Xu, Chunmei Ding, Changsheng Zhao, Jianshu Li


  • Bioinspired Peptide-Decorated Tannic Acid for in Situ Remineralization of Tooth Enamel: In Vitro and in Vivo Evaluation

    by Xiao Yang, Bo Yang, Libang He, Ruiqi Li, Yixue Liao, Shuhui Zhang, Yinxin Yang, Xinyuan Xu, Dongyue Zhang, Hong Tan, et al.

    Tooth enamel can be eroded by the local cariogenic bacteria in plaque or nonbacterial factors in the oral environment. The damage is irreversible in most situations. For the etched human tooth enamel to be restored in situ, a salivary-acquired pellicle (SAP) bioinspired tannic acid (SAP-TA) is synthesized. Statherin is one of the SAP proteins that can selectively adsorb onto enamel surface. Peptide sequence DDDEEKC is a bioinspired sequence of statherin and has the adsorption capacity of hydroxyapatite (HAP). TA has abundant polyphenol groups that can grasp Ca2+ in saliva to induce the regeneration of HAP crystal. Hence, SAP-TA not only enhances the binding force at the interface of remineralization but also mimics the biomineralization process of tooth enamel. Moreover, ferric ion can coordinate with SAP-TA to form a compact coating that increases the adsorbed amounts of SAP-TA on tooth enamel. Compared with SAP-TA alone, the etched enamels treated with SAP-TA/Fe(III) have a better remineralization effect and mechanical properties (surface microhardness recovery >80% and binding force of 64.85 N) when being incubated in artificial saliva for 2 weeks. In vivo remineralization performance is evaluated in a classical rat caries model. The polarizing microscope and micro-CT results show that SAP-TA/Fe(III) has a good effect on the remineralization process in a real oral environment, indicating that it is a promising repair material for in situ remineralization of enamel.