Cleverson Siqueira Santos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Cleverson Siqueira Santos has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Rosana Mossanha
Universidade Estadual de Ponta Grossa - UEPG, Department of Chemistry, 84030-000 Ponta Grossa, Brazil
4 shared publications- Christiana Andrade Pessôa
Department of Chemistry, State University of Ponta Grossa, Ponta Grossa, Brazil
3 shared publications Carolina Maria Fioramonti Calixto
Universidade Estadual de Ponta Grossa – UEPG
1 shared publicationChristiana A. Pessôa
1 shared publicationChristiana Andrade Pessoa
Universidade Estadual de Ponta Grossa (UEPG), Department of Chemistry, 84030-000 Ponta Grossa, Paraná, Brazil
1 shared publication- Jarem Raul Garcia
State University of Ponta Grossa, Uvaranas Campus, Av. Gal. Carlos Cavalcanti, 4748, 84030-900, Ponta Grossa, PR, Brazil
1 shared publication
Latest Publications
- 27 January 2016
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 163 (5) , B158-B162
Electrochemical Immunosensor for Qualitative Diagnosis of the American Trypanosomiasis Based on Gold Modified with 3-Mercaptopropionic
This paper describes the development of a label-free electrochemical immunosensor for the qualitative detection of American trypanosomiasis in serum samples. The immunosensor was constructed using self assembled monolayer technique with gold substrate modified with monolayer of 3-mercaptopropionic acid. The T. cruzi antigens were immobilized after activation carboxylic groups in monolayer with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide and N-hydroxysuccinimide. The parameters that can interfere the impedimetric response of the immunosensor response such as, concentration and incubation time in the solution of T. cruzi antigens, concentration of bovine serum albumin and incubation time in the solution of T. cruzi antibodies were optimized in the presence of the probe molecule hexacyanoferrate(II)/(III), using cyclic voltammetry and electrochemical impedance spectroscopy. The interaction between antigen–antibody was monitored using electrochemical impedance spectroscopy and the results were expressed in terms of the increase of the charge transfer resistance across the interface. The immunosensor showed selective and sensitive in the qualitative detection of T. cruzi antibodies in serum samples infected with toxoplasma antibodies. Therefore, the proposed methodology is a promising alternative for the development of a immunosensor for serological qualitative diagnosis of Chagas disease.
- 27 January 2016
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 163 (5) , B158-B162
Electrochemical Immunosensor for Qualitative Diagnosis of the American Trypanosomiasis Based on Gold Modified with 3-Mercaptopropionic
This paper describes the development of a label-free electrochemical immunosensor for the qualitative detection of American trypanosomiasis in serum samples. The immunosensor was constructed using self assembled monolayer technique with gold substrate modified with monolayer of 3-mercaptopropionic acid. The T. cruzi antigens were immobilized after activation carboxylic groups in monolayer with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide and N-hydroxysuccinimide. The parameters that can interfere the impedimetric response of the immunosensor response such as, concentration and incubation time in the solution of T. cruzi antigens, concentration of bovine serum albumin and incubation time in the solution of T. cruzi antibodies were optimized in the presence of the probe molecule hexacyanoferrate(II)/(III), using cyclic voltammetry and electrochemical impedance spectroscopy. The interaction between antigen–antibody was monitored using electrochemical impedance spectroscopy and the results were expressed in terms of the increase of the charge transfer resistance across the interface. The immunosensor showed selective and sensitive in the qualitative detection of T. cruzi antibodies in serum samples infected with toxoplasma antibodies. Therefore, the proposed methodology is a promising alternative for the development of a immunosensor for serological qualitative diagnosis of Chagas disease.
- 1 April 2015
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 162 (7) , B145-B151
Mixed Self-Assembled Monolayers of Mercaptoundecanoic Acid and Thiolactic Acid for the Construction of an Enzymatic Biosensor for Hydroquinone Determination
A horseradish peroxidase (HRP) biosensor was constructed using binary self-assembled monolayers (SAM) of 11-mercaptoundecanoic acid (MUA) and thiolactic acid (TLA) on gold surface. The advantages of using mixed SAM for the enzyme immobilization is that the long carbon chain molecules act as a support for the enzyme while the short chain molecules favor the electron transfer process. In order to obtain this modified surface, the gold electrode was incubated in a solution containing different proportions of MUA and TLA and the best concentration ratio of these molecules was 0.5 and 1.0 mmol L−1, respectively. The preparation steps and the biosensor response were monitored by electrochemical techniques. The biosensor proposed was applied to determine hydroquinone in a 0.10 mol L−1 phosphate buffer solution containing H2O2 0.3 mmol L−1. The Au-SAMmix-HRP electrode, in the presence of hydrogen peroxide, catalyzes the oxidation of hydroquinone to the corresponding quinone, which is electrochemically reduced back to hydroquinone at −0.08 V vs Ag/AgCl. The analytical curve was linear for hydroquinone concentrations from 5.0 to 30 μmol L−1 and the detection limit was 1.26 μmol L−1. The lifetime of this biosensor was 15 days. The modified electrode displayed good reproducibility, sensitivity and stability for the determination of hydroquinone.
- 1 April 2015
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 162 (7) , B145-B151
Mixed Self-Assembled Monolayers of Mercaptoundecanoic Acid and Thiolactic Acid for the Construction of an Enzymatic Biosensor for Hydroquinone Determination
A horseradish peroxidase (HRP) biosensor was constructed using binary self-assembled monolayers (SAM) of 11-mercaptoundecanoic acid (MUA) and thiolactic acid (TLA) on gold surface. The advantages of using mixed SAM for the enzyme immobilization is that the long carbon chain molecules act as a support for the enzyme while the short chain molecules favor the electron transfer process. In order to obtain this modified surface, the gold electrode was incubated in a solution containing different proportions of MUA and TLA and the best concentration ratio of these molecules was 0.5 and 1.0 mmol L−1, respectively. The preparation steps and the biosensor response were monitored by electrochemical techniques. The biosensor proposed was applied to determine hydroquinone in a 0.10 mol L−1 phosphate buffer solution containing H2O2 0.3 mmol L−1. The Au-SAMmix-HRP electrode, in the presence of hydrogen peroxide, catalyzes the oxidation of hydroquinone to the corresponding quinone, which is electrochemically reduced back to hydroquinone at −0.08 V vs Ag/AgCl. The analytical curve was linear for hydroquinone concentrations from 5.0 to 30 μmol L−1 and the detection limit was 1.26 μmol L−1. The lifetime of this biosensor was 15 days. The modified electrode displayed good reproducibility, sensitivity and stability for the determination of hydroquinone.
- 8 February 2015
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 45 (4) , 325-334
Biosensor for carbaryl based on gold modified with PAMAM-G4 dendrimer
- 8 February 2015
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 45 (4) , 325-334
Biosensor for carbaryl based on gold modified with PAMAM-G4 dendrimer
- 27 July 2014
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 44 (9) , 1047-1058
The influence of organization of LbL films containing a silsesquioxane polymer on the electrochemical response of dopamine
- 27 July 2014
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 44 (9) , 1047-1058
The influence of organization of LbL films containing a silsesquioxane polymer on the electrochemical response of dopamine