Chitrakant Sahu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chitrakant Sahu has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Jawar Singh
Department of Electrical Engineering, Indian Institute of Technology Patna, Bihar, India
16 shared publications - Nawaz Shafi
School of Electronics Engineering, VIT University, Vellore, Tamil Nadu, India
6 shared publications - Chinnamuthan Periasamy
Electronics and Communication Engineering Department, Malaviya National Institute of Technology, Jaipur, INDIA
5 shared publications - Aasif Mohammad Bhat
Department of Electronics and Communication Engineering, Malaviya National Institute of Technology, Jaipur, India
3 shared publications - Jaydeep Singh Parmar
Deemed University
3 shared publications P.N. Kondekar
Dept of ECE, IIITDM Jabalpur, MP, India
3 shared publications
Latest Publications
- 2 September 2026
- Published by Elsevier in Integration
- Vol. 111
Multi-parameter optimization of Dual-Gate Tunnel Field-Effect Transistors using Artificial Neural Networks
- 2 September 2026
- Published by Elsevier in Integration
- Vol. 111
Multi-parameter optimization of Dual-Gate Tunnel Field-Effect Transistors using Artificial Neural Networks
- Open Access
- 25 May 2026
- Published by Elsevier in SSRN Electronic Journal
Multi-Parameter Optimization of Dual-Gate Tunnel Field-Effect Transistors Using Artificial Neural Networks
The prediction and optimization of low-power semiconductor devices have become increasingly important for the design of next-generation energy-efficient electronic systems. Although TCAD simulations provide accurate device analysis, they require significant computational time and resources, particularly during multi-parameter optimization. To overcome these limitations, this work proposes a machine learning (ML)-based framework for accurate prediction of the 𝐼𝐷𝑆-𝑉𝐺𝑆 characteristics of Dual-Gate Tunnel Field-Effect Transistors (DG-TFETs) using TCAD generated datasets. Key device parameters, including oxide thickness (𝑡𝑜𝑥), gate length (𝐿𝑔), gate work function (𝜙𝐺), and temperature (𝑇) are utilized as input features to capture the nonlinear electrical behavior of the device. A comparative analysis is carried out using Polynomial Regression (PR), Decision Tree (DT), Random Forest Regression (RFR), Light Gradient Boosting (LGB), and Artificial Neural Network (ANN) models. The performance of these models is evaluated using statistical metrics such as 𝑅2, Mean Squared Error (MSE), Mean Absolute Error (MAE), and Mean Absolute Percentage Error (MAPE). Among all the models, ANN achieved the highest prediction accuracy with an 𝑅2 value of nearly 0.9988 and the lowest prediction errors. In addition, the proposed framework is employed for multiparameter device optimization by simultaneously maximizing the 𝐼ON∕𝐼OFF ratio and minimizing RC delay. The optimized ML predictions exhibit excellent agreement with TCAD simulation results, achieving an overall optimization accuracy of approximately 99.55%. The proposed ML-assisted framework considerably reduces computational complexity while providing a fast, reliable, and efficient approach for DG-TFET modeling and optimization
- 25 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMulti-Parameter Optimization of Dual-Gate Tunnel Field-Effect Transistors Using Artificial Neural Networks
The prediction and optimization of low-power semiconductor devices have become increasingly important for the design of next-generation energy-efficient electronic systems. Although TCAD simulations provide accurate device analysis, they require significant computational time and resources, particularly during multi-parameter optimization. To overcome these limitations, this work proposes a machine learning (ML)-based framework for accurate prediction of the 𝐼𝐷𝑆-𝑉𝐺𝑆 characteristics of Dual-Gate Tunnel Field-Effect Transistors (DG-TFETs) using TCAD generated datasets. Key device parameters, including oxide thickness (𝑡𝑜𝑥), gate length (𝐿𝑔), gate work function (𝜙𝐺), and temperature (𝑇) are utilized as input features to capture the nonlinear electrical behavior of the device. A comparative analysis is carried out using Polynomial Regression (PR), Decision Tree (DT), Random Forest Regression (RFR), Light Gradient Boosting (LGB), and Artificial Neural Network (ANN) models. The performance of these models is evaluated using statistical metrics such as 𝑅2, Mean Squared Error (MSE), Mean Absolute Error (MAE), and Mean Absolute Percentage Error (MAPE). Among all the models, ANN achieved the highest prediction accuracy with an 𝑅2 value of nearly 0.9988 and the lowest prediction errors. In addition, the proposed framework is employed for multiparameter device optimization by simultaneously maximizing the 𝐼ON∕𝐼OFF ratio and minimizing RC delay. The optimized ML predictions exhibit excellent agreement with TCAD simulation results, achieving an overall optimization accuracy of approximately 99.55%. The proposed ML-assisted framework considerably reduces computational complexity while providing a fast, reliable, and efficient approach for DG-TFET modeling and optimization
- 11 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (10) , 15784-15792
Performance Assessment of AlGaN/GaN HEMT for Human Serum Albumin Detection Using Charge Deduction Methodology
This article investigates the applicability of open gated high electron mobility transistor (HEMT) as a bio-sensing platform for human serum albumin (HSA). The 3-Aminopropyltriethoxysilane (APTES) is a binding molecule to Albumin defined by its dielectric constant and 2nm of thickness in the open gate region. The APTES functionalization and biomolecule immobilization have been confirmed by the change in drain current characteristics. The charge equivalent for a broad range of albumin concentrations (0.005 pg/l to 0.06 pg/l) was calculated by charge deduction method and introduced at sensing interface to evaluate the sensor response. The sensor performance was extracted for different gate oxides (SiO 2 , Al 2 O 3 , HfO 2 ) and gate to drain distance (L GD = 2 μm, 4 μm, 6 μm, and 8 μm) in terms of threshold voltage variation, drain current sensitivity, along with response and recovery time. The proposed device shows a maximum variation in drain current of 38.12 mA/mm at V GS = -1.5 V and a threshold voltage sensitivity of 65 mV for the Al 2 O 3 gate oxide at L GD = 2μm, respectively for 0.06 pg/l of concentration. The limit of detection obtained is 0.94 fg/l for SiO 2 gate oxide at V GS = -1.5 V. All the results have been extracted using the Silvaco Atlas device simulation tool. The sensitivity assessments demonstrates that APTES functionalized open gated HEMT can be a good candidate for albumin detection and other biosensing applications.
- 11 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (10) , 15784-15792
Performance Assessment of AlGaN/GaN HEMT for Human Serum Albumin Detection Using Charge Deduction Methodology
This article investigates the applicability of open gated high electron mobility transistor (HEMT) as a bio-sensing platform for human serum albumin (HSA). The 3-Aminopropyltriethoxysilane (APTES) is a binding molecule to Albumin defined by its dielectric constant and 2nm of thickness in the open gate region. The APTES functionalization and biomolecule immobilization have been confirmed by the change in drain current characteristics. The charge equivalent for a broad range of albumin concentrations (0.005 pg/l to 0.06 pg/l) was calculated by charge deduction method and introduced at sensing interface to evaluate the sensor response. The sensor performance was extracted for different gate oxides (SiO 2 , Al 2 O 3 , HfO 2 ) and gate to drain distance (L GD = 2 μm, 4 μm, 6 μm, and 8 μm) in terms of threshold voltage variation, drain current sensitivity, along with response and recovery time. The proposed device shows a maximum variation in drain current of 38.12 mA/mm at V GS = -1.5 V and a threshold voltage sensitivity of 65 mV for the Al 2 O 3 gate oxide at L GD = 2μm, respectively for 0.06 pg/l of concentration. The limit of detection obtained is 0.94 fg/l for SiO 2 gate oxide at V GS = -1.5 V. All the results have been extracted using the Silvaco Atlas device simulation tool. The sensitivity assessments demonstrates that APTES functionalized open gated HEMT can be a good candidate for albumin detection and other biosensing applications.
- Open Access
- 26 February 2024
- Published by Springer Nature in Research Square
An optoelectronic Portable Device for Real-Time Nitrate Detection in Water
The utilization of autonomous devices has disrupted conventional digital monitoring across diverse domains, particularly impacting environmental monitoring, agriculture, healthcare, as well as healthcare diagnostics. These contemporary autonomous deployables in the field enable dependable testing, gathering of data, and swift transmission of information. Among a variety of prevalent identifying techniques, the spectrophotometric approach stands out for its ability to precisely detect environmental samples at very low concentrations, offering cost-effectiveness and user-friendly operation. Consequently, this study focuses on designing a standalone, handy real-time nitrate concentration detection in water samples, employing readily available light-emitting diodes (LEDs) and photodi-odes with a peak response matching the absorption wavelength of the quartz cuvette in the spectrophotometric detection device. The end product is a portable, extremely sensitive, economical, and energy-efficient device. It integrates a display for offline transfer of information. In a proof-of-concept scenario, nitrate samples were spectrophotometrically tested, detecting nitrate in the linear range of 10–140 mg/L with a limit of detection (LOD) of 0.0072 mg/L. With suitable modifications to the optoelectronic components, the developed spectrophotometric detection platform could potentially be adapted to sense various analytes.
- 26 February 2024
- Published by Springer Nature in Research Square
Open AccessAn optoelectronic Portable Device for Real-Time Nitrate Detection in Water
The utilization of autonomous devices has disrupted conventional digital monitoring across diverse domains, particularly impacting environmental monitoring, agriculture, healthcare, as well as healthcare diagnostics. These contemporary autonomous deployables in the field enable dependable testing, gathering of data, and swift transmission of information. Among a variety of prevalent identifying techniques, the spectrophotometric approach stands out for its ability to precisely detect environmental samples at very low concentrations, offering cost-effectiveness and user-friendly operation. Consequently, this study focuses on designing a standalone, handy real-time nitrate concentration detection in water samples, employing readily available light-emitting diodes (LEDs) and photodi-odes with a peak response matching the absorption wavelength of the quartz cuvette in the spectrophotometric detection device. The end product is a portable, extremely sensitive, economical, and energy-efficient device. It integrates a display for offline transfer of information. In a proof-of-concept scenario, nitrate samples were spectrophotometrically tested, detecting nitrate in the linear range of 10–140 mg/L with a limit of detection (LOD) of 0.0072 mg/L. With suitable modifications to the optoelectronic components, the developed spectrophotometric detection platform could potentially be adapted to sense various analytes.
- 3 September 2023
- Published by Springer Nature
- p. 55-66
Design and Realization of Logic Gates Using Double Gate Tunnel FET
- 3 September 2023
- Published by Springer Nature
- p. 55-66
Design and Realization of Logic Gates Using Double Gate Tunnel FET
- 6 May 2023
- Published by Springer Nature in Silicon
- Vol. 15 (14) , 1-12
Design and Performance Projection of Virtually Doped Dual Gate Junctionless IMOS
- 6 May 2023
- Published by Springer Nature in Silicon
- Vol. 15 (14) , 1-12
Design and Performance Projection of Virtually Doped Dual Gate Junctionless IMOS
- 18 October 2021
- Published by Springer Nature in Silicon
- Vol. 14 (12) , 6829-6836
Electrical Characterization and Study of Current Drift Phenomena and Hysteresis Mechanism in Junctionless Ion-Sensitive Field-Effect Transistor
- 18 October 2021
- Published by Springer Nature in Silicon
- Vol. 14 (12) , 6829-6836
Electrical Characterization and Study of Current Drift Phenomena and Hysteresis Mechanism in Junctionless Ion-Sensitive Field-Effect Transistor
- Open Access
- 25 September 2021
- Published by Wiley in International Journal of RF and Microwave Computer-Aided Engineering
- Vol. 32 (1) , e22915
Influence of dielectric material near tunnel junction on analog/ RF and linearity figure of merits in hetero dielectric ( HG ) TFET : A detailed study
- 25 September 2021
- Published by Wiley in International Journal of RF and Microwave Computer-Aided Engineering
- Vol. 32 (1) , e22915
Open AccessInfluence of dielectric material near tunnel junction on analog/ RF and linearity figure of merits in hetero dielectric ( HG ) TFET : A detailed study
- 26 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (18) , 19753-19761
AlGaN/GaN HEMT pH Sensor Simulation Model and Its Maximum Transconductance Considerations for Improved Sensitivity
In this work, AlGaN/GaN high electron mobility transistor (HEMT) pH sensing simulation model is presented along with the sensitivity analysis to different pH values of an electrolyte by considering charged adsorbates systematically. Investigations were performed by studying the effect of pH values on device transfer characteristics and a smooth operation is observed with good pH resolution. The output current sensitivity is analyzed from both linear and saturation regions highlighting the response obtained at different drain bias. The device intricacies and sensing mechanism is also explained and demonstrated by analyzing the channel conductance, conduction band, potential profile and coupling capacitance along with the charge distribution profile at various interfaces using ATLAS Silvaco device simulation tool. The pH of solution is modelled by incorporating charged adsorbates as interface charge density at oxide-semiconductor interface in HEMT for the first time to best of our knowledge. The voltage sensitivity (SV) of 110 mV/pH was observed which is ~2 times beyond Nernst limit of sensitivity (59 mV/pH) and the current sensitivity (SI) is 17 mA/mm/pH which is 3 orders higher than silicon based devices. The effects of region of operation is also reported with a maximum upto 8 times higher sensitivity being observed in terms of maximum transconductance (gm) considerations and a near zero maximum gm was found to be optimum condition for higher sensitivity operation in reference electrode free configuration. Therefore high sensitive response along with better biocompatibility of AlGaN/GaN HEMT paves its way in next generation biosensing applications.
- 26 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (18) , 19753-19761
AlGaN/GaN HEMT pH Sensor Simulation Model and Its Maximum Transconductance Considerations for Improved Sensitivity
In this work, AlGaN/GaN high electron mobility transistor (HEMT) pH sensing simulation model is presented along with the sensitivity analysis to different pH values of an electrolyte by considering charged adsorbates systematically. Investigations were performed by studying the effect of pH values on device transfer characteristics and a smooth operation is observed with good pH resolution. The output current sensitivity is analyzed from both linear and saturation regions highlighting the response obtained at different drain bias. The device intricacies and sensing mechanism is also explained and demonstrated by analyzing the channel conductance, conduction band, potential profile and coupling capacitance along with the charge distribution profile at various interfaces using ATLAS Silvaco device simulation tool. The pH of solution is modelled by incorporating charged adsorbates as interface charge density at oxide-semiconductor interface in HEMT for the first time to best of our knowledge. The voltage sensitivity (SV) of 110 mV/pH was observed which is ~2 times beyond Nernst limit of sensitivity (59 mV/pH) and the current sensitivity (SI) is 17 mA/mm/pH which is 3 orders higher than silicon based devices. The effects of region of operation is also reported with a maximum upto 8 times higher sensitivity being observed in terms of maximum transconductance (gm) considerations and a near zero maximum gm was found to be optimum condition for higher sensitivity operation in reference electrode free configuration. Therefore high sensitive response along with better biocompatibility of AlGaN/GaN HEMT paves its way in next generation biosensing applications.
- 16 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanotechnology
- Vol. 20 (1536125X) , 534-542
Analytical Modeling of Surface Potential and Figure of Merit Computation for Planar Junctionless pH Sensing BioFET
Herein this paper we propose a surface potential-based analytical model for planar junctionless field effect transistor (JL-FET) for pH sensing. The electrolyte considered is phosphate buffer saline (PBS) solution which has been modeled as a three-layered stacked structure consisting of stern layer, ion-permeable membrane, and bulk electrolyte. The proposed model has been deduced considering Poissons equation in the channel region. Relative shift in threshold voltage (VTh) and maximum drain current (IDS,max) have been used as sensitivity metrics. The low concentrations of electrolyte (0.01), yielded higher VTh sensitivity of 63mV/pH and 59mV/pH for bottom and liquid gate respectively as compared to higher molar concentrations of electrolyte. For 0.01 PBS The aggregate drain current shift has been found to be 52.8 A/pH and is larger for liquid gate operation while as for bottom gate, shift of 18.9 A/pH is observed. Further considering pH range of 1-14, we computed various figure of merits (FOMs) that include sensitivity, linearity and signal to noise ratio for the device. The FOMs were computed and analyzed for independent operation of liquid and bottom gate for three different molarities of PBS (1, 0.1, 0.01) each with pH range from 1 to 14. Signal to noise ratio of drain current is found maximum for low molar concentrations of electrolyte and also is highest at point of maximum transconductance. The results obtained from the analytical model are in good coherence with the TCAD simulation model.
- 16 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanotechnology
- Vol. 20 (1536125X) , 534-542
Analytical Modeling of Surface Potential and Figure of Merit Computation for Planar Junctionless pH Sensing BioFET
Herein this paper we propose a surface potential-based analytical model for planar junctionless field effect transistor (JL-FET) for pH sensing. The electrolyte considered is phosphate buffer saline (PBS) solution which has been modeled as a three-layered stacked structure consisting of stern layer, ion-permeable membrane, and bulk electrolyte. The proposed model has been deduced considering Poissons equation in the channel region. Relative shift in threshold voltage (VTh) and maximum drain current (IDS,max) have been used as sensitivity metrics. The low concentrations of electrolyte (0.01), yielded higher VTh sensitivity of 63mV/pH and 59mV/pH for bottom and liquid gate respectively as compared to higher molar concentrations of electrolyte. For 0.01 PBS The aggregate drain current shift has been found to be 52.8 A/pH and is larger for liquid gate operation while as for bottom gate, shift of 18.9 A/pH is observed. Further considering pH range of 1-14, we computed various figure of merits (FOMs) that include sensitivity, linearity and signal to noise ratio for the device. The FOMs were computed and analyzed for independent operation of liquid and bottom gate for three different molarities of PBS (1, 0.1, 0.01) each with pH range from 1 to 14. Signal to noise ratio of drain current is found maximum for low molar concentrations of electrolyte and also is highest at point of maximum transconductance. The results obtained from the analytical model are in good coherence with the TCAD simulation model.