Jae-Hong Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jae-Hong Kim has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Ki-Baek Kim
Department of Dental Lab Technology, Daejeon Health Institute of Technology, Daejeon, Korea
7 shared publications - Se-Yeon Kim
Department of Dental Laboratory Science, College of Health Science, Catholic University of Pusan, Busan, Korea
7 shared publications - Ji-Hwan Kim
Department of Dental Laboratory Science and Engineering, Graduate School, Korea University, Seoul, Korea
3 shared publications - Dong-Yeon Kim
Department of Dental Technology, Yeonsung University, Anyang, Korea
2 shared publications - Hong-Seok Moon
Department of Prosthodontics, Yonsei University College of Dentistry, Seoul, Republic of Korea
2 shared publications - Hyunmin Choi
Department of Prosthodontics, Yonsei University College of Denistry, Seoul, Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by Korean Academy of Dental Technology in Journal of Korean Acedemy of Dental Technology
- Vol. 48 (3) , 119-125
Effect of dual-heating microwave sintering on the optical properties of pre-shaded zirconia
Se-Yeon Kim, Jae-Hong Kim. Journal of Technologic Dentistry 2026;48:119-25. https://doi.org/10.14347/jtd.2026.48.3.119
- 30 September 2026
- Published by Korean Academy of Dental Technology in Journal of Korean Acedemy of Dental Technology
- Vol. 48 (3) , 119-125
Open AccessEffect of dual-heating microwave sintering on the optical properties of pre-shaded zirconia
Se-Yeon Kim, Jae-Hong Kim. Journal of Technologic Dentistry 2026;48:119-25. https://doi.org/10.14347/jtd.2026.48.3.119
- Open Access
- 30 June 2026
- Published by Korean Academy of Dental Technology in Journal of Korean Acedemy of Dental Technology
- Vol. 48 (2) , 57-63
Evaluation of marginal and internal fit of 3-unit bridge provisional restorations fabricated by different photopolymerization-based additive manufacturing
- 30 June 2026
- Published by Korean Academy of Dental Technology in Journal of Korean Acedemy of Dental Technology
- Vol. 48 (2) , 57-63
Open AccessEvaluation of marginal and internal fit of 3-unit bridge provisional restorations fabricated by different photopolymerization-based additive manufacturing
- Open Access
- 30 March 2026
- Published by Korean Academy of Dental Technology in Journal of Korean Acedemy of Dental Technology
- Vol. 48 (1) , 17-23
Effect of a dual-heating microwave sintering process on the fit of 3-unit full-contour zirconia bridges
Se-Yeon Kim, Jae-Hong Kim. Journal of Technologic Dentistry 2026;48:17-23. https://doi.org/10.14347/jtd.2026.48.1.17
- 30 March 2026
- Published by Korean Academy of Dental Technology in Journal of Korean Acedemy of Dental Technology
- Vol. 48 (1) , 17-23
Open AccessEffect of a dual-heating microwave sintering process on the fit of 3-unit full-contour zirconia bridges
Se-Yeon Kim, Jae-Hong Kim. Journal of Technologic Dentistry 2026;48:17-23. https://doi.org/10.14347/jtd.2026.48.1.17
- Open Access
- 30 September 2025
- Published by Korean Academy of Dental Technology in Journal of Korean Acedemy of Dental Technology
- Vol. 47 (3) , 169-176
Precision of fit and surface roughness of SLM-fabricated substructures according to different post-processing protocols
Se-Yeon Kim, Jae-Hong Kim. Journal of Technologic Dentistry 2025;47:169-76. https://doi.org/10.14347/jtd.2025.47.3.169
- 30 September 2025
- Published by Korean Academy of Dental Technology in Journal of Korean Acedemy of Dental Technology
- Vol. 47 (3) , 169-176
Open AccessPrecision of fit and surface roughness of SLM-fabricated substructures according to different post-processing protocols
Se-Yeon Kim, Jae-Hong Kim. Journal of Technologic Dentistry 2025;47:169-76. https://doi.org/10.14347/jtd.2025.47.3.169
- Open Access
- 30 June 2025
- Published by Korean Academy of Dental Technology in Journal of Korean Acedemy of Dental Technology
- Vol. 47 (2) , 127-133
Effect of internal coloring treatment on the marginal and internal fit of monolithic zirconia crowns: an in vitro study
Doo-Hyeon Hwang, Jae-Hong Kim. Journal of Technologic Dentistry 2025;47:127-33. https://doi.org/10.14347/jtd.2025.47.2.127
- 30 June 2025
- Published by Korean Academy of Dental Technology in Journal of Korean Acedemy of Dental Technology
- Vol. 47 (2) , 127-133
Open AccessEffect of internal coloring treatment on the marginal and internal fit of monolithic zirconia crowns: an in vitro study
Doo-Hyeon Hwang, Jae-Hong Kim. Journal of Technologic Dentistry 2025;47:127-33. https://doi.org/10.14347/jtd.2025.47.2.127
- Open Access
- 30 June 2025
- Published by Korean Academy of Dental Technology in Journal of Korean Acedemy of Dental Technology
- Vol. 47 (2) , 120-126
Effect of the cement space on the marginal and internal fit of the metal coping fabricated by selective laser melting
Yoon-Jung Kim, Jae-Hong Kim. Journal of Technologic Dentistry 2025;47:120-6. https://doi.org/10.14347/jtd.2025.47.2.120
- 30 June 2025
- Published by Korean Academy of Dental Technology in Journal of Korean Acedemy of Dental Technology
- Vol. 47 (2) , 120-126
Open AccessEffect of the cement space on the marginal and internal fit of the metal coping fabricated by selective laser melting
Yoon-Jung Kim, Jae-Hong Kim. Journal of Technologic Dentistry 2025;47:120-6. https://doi.org/10.14347/jtd.2025.47.2.120
- Open Access
- 20 January 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (1) , 67
Evaluation of Internal and Marginal Accuracy (Trueness and Precision) of Laminates Using DLP Printing and Milling Methods
This study evaluated the internal and marginal accuracy (trueness and precision) of zirconia laminate veneers fabricated using the DLP printing and milling method, employing 3D analysis software program. The maxillary central incisor tooth of a typodont model was prepared by a dentist and scanned using a desktop scanner. An anatomical zirconia laminate was designed using computer-aided design (CAD) software and saved in a standard tessellation language (STL) format. Thirty zirconia laminates were manufactured using a milling machine (MLL group) and a DLP printer (PTL group). All the specimens were scanned, and their internal and marginal areas were edited accordingly. The root-mean-square value was used to assess the accuracy of the internal and marginal areas of the zirconia laminates. Statistical significance was evaluated using the Mann–Whitney U test. Statistically significant differences were found in RMS values for both groups in the internal and marginal areas (p < 0.001 and p = 0.034, respectively). The MLL and PTL groups differed significantly in terms of precision (p = 0.017), but not at the margin (p = 0.361). DLP-printed zirconia laminates demonstrated stable and consistent performance, making the technique a reliable option for producing esthetic prostheses.
- 20 January 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (1) , 67
Open AccessEvaluation of Internal and Marginal Accuracy (Trueness and Precision) of Laminates Using DLP Printing and Milling Methods
This study evaluated the internal and marginal accuracy (trueness and precision) of zirconia laminate veneers fabricated using the DLP printing and milling method, employing 3D analysis software program. The maxillary central incisor tooth of a typodont model was prepared by a dentist and scanned using a desktop scanner. An anatomical zirconia laminate was designed using computer-aided design (CAD) software and saved in a standard tessellation language (STL) format. Thirty zirconia laminates were manufactured using a milling machine (MLL group) and a DLP printer (PTL group). All the specimens were scanned, and their internal and marginal areas were edited accordingly. The root-mean-square value was used to assess the accuracy of the internal and marginal areas of the zirconia laminates. Statistical significance was evaluated using the Mann–Whitney U test. Statistically significant differences were found in RMS values for both groups in the internal and marginal areas (p < 0.001 and p = 0.034, respectively). The MLL and PTL groups differed significantly in terms of precision (p = 0.017), but not at the margin (p = 0.361). DLP-printed zirconia laminates demonstrated stable and consistent performance, making the technique a reliable option for producing esthetic prostheses.
- Open Access
- 28 November 2024
- Published by MDPI AG in Biomimetics
- Vol. 9 (12)
A Comparison of Internal, Marginal, and Incisal Gaps in Zirconia Laminates Fabricated Using Subtractive Manufacturing and 3D Printing Methods
DLP printing is a new method for producing zirconia laminates that ensure clinically acceptable gaps in the internal, marginal, and incisal regions. A typical model of a central maxillary incisor was prepped by a dentist and scanned. The laminate was designed using CAD software version 2023. The laminates were fabricated using a milling machine (LSM group) and a DLP printer (LAM group) (N = 20). The gap was evaluated using the silicone replica method at designated measurement points. Statistical analyses were performed. The Shapiro–Wilk and Kolmogorov–Smirnov tests indicated a non-normal distribution, and the Mann–Whitney test was used. The LSM group had wider gaps than the LAM group except at point E (59.5 µm). The LAM group had wider gaps than the LSM group, except at points H (51.70 µm). No significant differences were observed between the LSM and LAM groups at any of the labiolingual measurement points. In the mesiodistal plane, a significant difference was observed between the two groups at point G, which was adjacent to the mesial side (p < 0.05). The results of this study indicate that DLP printing offers an innovative approach for producing zirconia laminates, as the incisal, internal, and marginal gaps are within clinically acceptable ranges compared with the AM method.
- 28 November 2024
- Published by MDPI AG in Biomimetics
- Vol. 9 (12)
Open AccessA Comparison of Internal, Marginal, and Incisal Gaps in Zirconia Laminates Fabricated Using Subtractive Manufacturing and 3D Printing Methods
DLP printing is a new method for producing zirconia laminates that ensure clinically acceptable gaps in the internal, marginal, and incisal regions. A typical model of a central maxillary incisor was prepped by a dentist and scanned. The laminate was designed using CAD software version 2023. The laminates were fabricated using a milling machine (LSM group) and a DLP printer (LAM group) (N = 20). The gap was evaluated using the silicone replica method at designated measurement points. Statistical analyses were performed. The Shapiro–Wilk and Kolmogorov–Smirnov tests indicated a non-normal distribution, and the Mann–Whitney test was used. The LSM group had wider gaps than the LAM group except at point E (59.5 µm). The LAM group had wider gaps than the LSM group, except at points H (51.70 µm). No significant differences were observed between the LSM and LAM groups at any of the labiolingual measurement points. In the mesiodistal plane, a significant difference was observed between the two groups at point G, which was adjacent to the mesial side (p < 0.05). The results of this study indicate that DLP printing offers an innovative approach for producing zirconia laminates, as the incisal, internal, and marginal gaps are within clinically acceptable ranges compared with the AM method.
- Open Access
- 30 March 2024
- Published by Korean Academy of Dental Technology in Journal of Korean Acedemy of Dental Technology
- Vol. 46 (1) , 1-7
Effect of cement space on marginal and internal fit of a zirconia core fabricated using by additive manufacturing
Ji-Won Min, Se-Yeon Kim, Jae-Hong Kim. Journal of Technologic Dentistry 2024;46:1-7. https://doi.org/10.14347/jtd.2024.46.1.1
- 30 March 2024
- Published by Korean Academy of Dental Technology in Journal of Korean Acedemy of Dental Technology
- Vol. 46 (1) , 1-7
Open AccessEffect of cement space on marginal and internal fit of a zirconia core fabricated using by additive manufacturing
Ji-Won Min, Se-Yeon Kim, Jae-Hong Kim. Journal of Technologic Dentistry 2024;46:1-7. https://doi.org/10.14347/jtd.2024.46.1.1
- Open Access
- 30 December 2023
- Published by Korean Academy of Dental Technology in Journal of Korean Acedemy of Dental Technology
- Vol. 45 (4) , 118-123
Survey research to implement a job-based national practical exam for dental technicians
Jae-Hong Kim, Ki-Baek Kim. Journal of Technologic Dentistry 2023;45:118-23. https://doi.org/10.14347/jtd.2023.45.4.118
- 30 December 2023
- Published by Korean Academy of Dental Technology in Journal of Korean Acedemy of Dental Technology
- Vol. 45 (4) , 118-123
Open AccessSurvey research to implement a job-based national practical exam for dental technicians
Jae-Hong Kim, Ki-Baek Kim. Journal of Technologic Dentistry 2023;45:118-23. https://doi.org/10.14347/jtd.2023.45.4.118