SKShinshu Katayama

Shinshu Katayama

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shinshu Katayama has a total of 87 co-authors. Here are the top co-authors by number of shared publications:

  • Shin Nunomiya

    Division of Intensive Care, Department of Anesthesiology and Intensive Care Medicine, Jichi Medical University School of Medicine, Shimotsuke, Tochigi, Japan Yokosuka General Hospital Uwamachi, Yokosuka, Kanagawa, Japan

    14 shared publications
  • Ken Tonai

    Division of Intensive Care, Department of Anesthesiology and Intensive Care Medicine, Jichi Medical University School of Medicine, Shimotsuke, Japan

    13 shared publications
  • Ken Tonai

    Division of Intensive Care, Department of Anesthesiology and Intensive Care Medicine, Jichi Medical University School of Medicine, Shimotsuke, Japan

    12 shared publications
  • Kansuke Koyama

    Division of Intensive Care, Department of Anesthesiology and Intensive Care Medicine, Jichi Medical University School of Medicine, Shimotsuke, Tochigi, Japan

    8 shared publications
  • Atsuko Shono

    Division of Intensive Care, Department of Anesthesiology and Intensive Care Medicine, Jichi Medical University School of Medicine, Shimotsuke, Japan

    7 shared publications
  • Jun Shima

    Division of Intensive Care, Department of Anaesthesiology and Intensive Care Medicine, Jichi Medical University School of Medicine, Shimotsuke, Japan

    7 shared publications

Latest Publications

  • Open Access

    Discontinuation, restart and survival associated with neuromuscular blocking agent use for hypoxemia in critically Ill patients: a multi-database retrospective cohort study

    by Gaku Okamura, Shigehiko Uchino, Taishi Saito, Shohei Ono, Yusuke Sasabuchi, Shinshu Katayama

    Background: The utilization of neuromuscular blocking agents (NMBAs) in hypoxemic critically ill patients varies, and real-world patterns of NMBA discontinuation and subsequent restart remain insufficiently described. This study aimed to evaluate patterns of NMBAs utilization and explore associations with subsequent NMBA restart and ICU mortality. Methods: A retrospective cohort study was conducted using an integrated intensive care database (MIMIC-III / IV, eICU, HiRID, AmsterdamUMCdb, and our institution). Mechanically ventilated patients with PaO 2 /FiO 2 (P/F) ratio < 200 who received NMBAs for > 24 h were included to analyze NMBA discontinuation ( n = 829). For those who discontinued NMBA during ICU stay ( n = 737), NMBA restart and ICU mortality were also evaluated. Results: Prolonged NMBA use exceeding 48 h occurred in 332 of 829 patients (40.0%), with substantial inter-dataset variability. Younger age, higher body mass index, later NMBA initiation and lower respiratory system compliance were associated with longer NMBA duration. Among the 737 patients who discontinued NMBA during the ICU stay, 291 (39.4%) required NMBA restart and 260 (35.3%) died in the ICU. Although NMBA duration was significantly associated with subsequent NMBA restart (Odds Ratio=1.006, CI 1.003–1.009, p < 0.001), it was not associated with ICU mortality (Odds Ratio=1.002, CI 0.999–1.005, p = 0.250). Conclusion: NMBA practices varied widely, and prolonged administration was common, with a high rate of restart following discontinuation. NMBA duration was associated with subsequent NMBA restart but not with ICU mortality. These findings highlight the need for further studies to identify clinical factors associated with NMBA discontinuation and restart and to better understand the clinical significance of these observed patterns in hypoxemic respiratory failure.

  • Operational Integration and Temporal Validation of a Continuously Deployed ICU Prediction Model

    by Seiya Nishiyama, Shigehiko Uchino, Taishi Saito, Kentaro Fukano, Shohei Ono, Tadashi Kamio, Shinshu Katayama

    Objectives: To operationalize and temporally validate an electronic medical record (EMR)-integrated machine learning system (Big data-driven Evaluation of Survival and Treatment in Acute Illness [BEST-AI]) that generates hourly predictions for multiple ICU outcomes, with emphasis on discrimination, calibration, and workflow integration. Design: Single-center hybrid study with stepwise clinical deployment and forward-in-time temporal validation. Setting: Thirty-bed tertiary mixed medical-surgical ICU in Japan. Patients: All ICU admissions from August 2017 to March 2025. Exclusions: age younger than 16 years or ICU stay less than 4 hours. Development cohort ( n = 11,176; from August 2017 to July 2024) and temporal validation cohort ( n = 1,127; from August 2024 to March 2025). Interventions: EMR-integrated deployment of BEST-AI providing hourly probabilistic predictions to clinicians within the EMR; no protocolized clinical interventions were mandated. Measurements and Main Results: Six prediction tasks (in-hospital mortality, ICU mortality, ICU discharge ≤ 72 hr, intubation ≤ 72 hr, extubation ≤ 72 hr, tracheostomy at ICU discharge) were evaluated. In temporal validation, the area under the receiver operating characteristic curves ranged from 0.856 to 0.960, and the area under the precision-recall curves from 0.302 to 0.786. Decile-based calibration showed overall good agreement; hospital mortality was slightly overestimated at higher predicted probabilities, whereas ICU mortality remained well aligned. The intubation task had comparatively lower discrimination and greater deviation from perfect calibration, consistent with low event counts and heterogeneous timing. A 24-hour landmark sensitivity analysis (one prediction per patient at 24 hr after ICU admission) preserved discrimination and calibration relative to the main analysis, supporting robustness beyond repeated-measures evaluation. The system was successfully maintained with automated hourly updates and EMR-embedded patient- and unit-level visualizations, without prescriptive alerts. Conclusions: A continuously deployed, EMR-integrated ICU prediction system achieved strong temporal discrimination and generally good calibration. Embedding real-time predictions into routine workflow was feasible, and the system was maintained with automated hourly updates. Prospective multicenter studies are warranted to assess transportability and clinical impact.

  • Open Access

    Comparison of airway opening pressure measurements: low-constant-flow vs. constant low-slope pressure ramp methods

    by Ken Tonai, Atsuko Shono, Ryuichi Nakayama, Shinshu Katayama

    The airway closure phenomenon occurs when the airway collapses, isolating the proximal airway from the distal alveoli. Airway opening pressure (AOP) is required to reopen closed airways. Two methods are available to measure AOP: the low-constant flow (AOPflow) and constant low-slope pressure ramp methods (AOPpres). The discrepancies between these two methods remain unclear. We investigated whether there is a difference between AOPflow and AOPpres when used for mechanically ventilated patients. In this single-center retrospective observational study, we included 42 patients who were mechanically ventilated owing to respiratory failure in the intensive care unit of a university hospital between January 2023 and October 2024. AOP was measured using two methods: AOPflow (5 L/min) and AOPpres (2 cmH2O/s). Agreement and correlation between the two methods were evaluated using Bland-Altman plots, Passing-Bablok regression, and Spearman’s rank correlation. AOP measured using AOPflow (median: 4.7 cmH2O) was higher than that measured using AOPpres (median: 1.9 cmH2O, P < 0.001). Nevertheless, the two were strongly correlated (ρ = 0.86, P < 0.001) in all patients. The regression equation was y = 1.39x + 0.90 (95% confidence interval [CI] for slope b: 1.20–1.65, 95% CI for intercept a: 0.48–1.64). In patients with AOPflow ≥5cmH2O, AOPflow was moderately correlated with AOPpres (ρ = 0.77, P < 0.001). The regression equation was y = 0.82x + 4.51 (95% CI for slope b: 0.50–1.17, 95% CI for intercept a: 2.57–6.72). The rate of pressure increase from the pressure at the beginning (0 cmH2O) of inflation up to AOPflow was 26.4 cmH2O/s (10.5–30.0) in all patients and was moderately correlated with the difference between AOPflow and AOPpres (ρ = 0.61, P < 0.001). Systematic biases were observed between AOPflow and AOPpres, with AOPflow tending to yield higher values. However, the physiological significance of the AOP values obtained from each method remains unclear, and caution is needed for clinical application.

  • Complex ventilatory dynamics in a patient with flail chest and diaphragmatic dysfunction

    by Atsuko Shono, Ken Tonai, Hisashi Imahase, Shinshu Katayama

  • Open Access

    Regional ventilation dynamics of electrical impedance tomography validated with four-dimensional computed tomography: single-center, prospective, observational study

    by Shinshu Katayama, Ken Tonai, Kie Nakamura, Misuzu Tsuji, Shinichiro Uchimasu, Atsuko Shono, Masamitsu Sanui

    The dynamic regional accuracy of electrical impedance tomography has not yet been validated. We aimed to compare the regional accuracy of electrical impedance tomography with that of four-dimensional computed tomography during dynamic ventilation. This single-center, prospective, observational study conducted in a general intensive care unit included adult patients receiving mechanical ventilation from July 2021 to February 2024. The patients were mechanically ventilated passively and underwent electrical impedance tomography and four-dimensional computed tomography on the same day. Overall, 45 patients were analyzed. The correlation coefficients in regional dynamic ventilation between four-dimensional computed tomography and electrical impedance tomography in each region were 0.963, 0.963, 0.835 (ventral, central, and dorsal, respectively) in the right lung and 0.947, 0.927, 0.823 (ventral, central, and dorsal, respectively) in the left lung. The correlation coefficient was low when the regional ventilation distribution detected by the electrical impedance tomography was < 2%. After excluding nine patients with a regional ventilation distribution of < 2%, the ventral, central, and dorsal correlation coefficients were 0.963, 0.963, and 0.946 in the right lung and 0.942, 0.924, and 0.951, respectively, in the left lung. Regional ventilation using electrical impedance tomography during dynamic ventilation was highly accurate and consistent with the time phase compared to four-dimensional computed tomography. Given the high correlation between these modalities, they can contribute significantly to further studies on regional ventilation dynamics. Trial registration number ClinicalTrials.gov (No. UMIN00044386).


  • No ventilation, no ARDS: insights from four-dimensional computed tomography as dynamic imaging

    by Gaku Okamura, Seiya Nishiyama, Shohei Ono, Shinshu Katayama