Yingfei Xue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yingfei Xue has a total of 100 co-authors. Here are the top co-authors by number of shared publications:
- Shilpa Sant
Department of Pharmaceutical Sciences, School of Pharmacy, University of Pittsburgh, Pittsburgh, PA, 15261, USA
9 shared publications - Giovanni Ferrari
Department of Surgery, Columbia University, New York, USA
8 shared publications - Vinayak Sant
Department of Pharmaceutics, Bombay College of Pharmacy, Kalina, Mumbai, India
8 shared publications - Akhil Patel
Department of Pharmaceutical Sciences, School of Pharmacy, University of Pittsburgh, Pittsburgh, PA 15261
6 shared publications Antonio Frasca
Department of Surgery, Columbia University , New York, NY , USA
4 shared publicationsRobert J. Levy
Division of Cardiology, Department of Pediatrics, Pediatric Heart Valve Center, The Children’s Hospital of Philadelphia, Philadelphia, PA 19104
4 shared publications
Latest Publications
- Open Access
- 27 December 2022
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 120 (1)
Bioprosthetic heart valve structural degeneration associated with metabolic syndrome: Mitigation with polyoxazoline modification
Bioprosthetic heart valves (BHV), made from glutaraldehyde-fixed xenografts, are widely used for surgical and transcatheter valve interventions but suffer from limited durability due to structural valve degeneration (SVD). We focused on metabolic syndrome (MetS), a risk factor for SVD and a highly prevalent phenotype in patients affected by valvular heart disease with a well-recognized cluster of comorbidities. Multicenter patient data (N = 251) revealed that patients with MetS were at significantly higher risk of accelerated SVD and required BHV replacement sooner. Using a next-generation proteomics approach, we identified significantly differential proteomes from leaflets of explanted BHV from MetS and non-MetS patients (N = 24). Given the significance of protein infiltration in MetS-induced SVD, we then demonstrated the protective effects of polyoxazoline modification of BHV leaflets to mitigate MetS-induced BHV biomaterial degeneration (calcification, tissue cross-linking, and microstructural changes) in an ex vivo serum model and an in vivo with MetS rat subcutaneous implants.
- 27 December 2022
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 120 (1)
Open AccessBioprosthetic heart valve structural degeneration associated with metabolic syndrome: Mitigation with polyoxazoline modification
Bioprosthetic heart valves (BHV), made from glutaraldehyde-fixed xenografts, are widely used for surgical and transcatheter valve interventions but suffer from limited durability due to structural valve degeneration (SVD). We focused on metabolic syndrome (MetS), a risk factor for SVD and a highly prevalent phenotype in patients affected by valvular heart disease with a well-recognized cluster of comorbidities. Multicenter patient data (N = 251) revealed that patients with MetS were at significantly higher risk of accelerated SVD and required BHV replacement sooner. Using a next-generation proteomics approach, we identified significantly differential proteomes from leaflets of explanted BHV from MetS and non-MetS patients (N = 24). Given the significance of protein infiltration in MetS-induced SVD, we then demonstrated the protective effects of polyoxazoline modification of BHV leaflets to mitigate MetS-induced BHV biomaterial degeneration (calcification, tissue cross-linking, and microstructural changes) in an ex vivo serum model and an in vivo with MetS rat subcutaneous implants.
- 23 August 2022
- Published by Elsevier in Biomaterials
- Vol. 288, 121756
A biomimetic multilayered polymeric material designed for heart valve repair and replacement
- 23 August 2022
- Published by Elsevier in Biomaterials
- Vol. 288, 121756
A biomimetic multilayered polymeric material designed for heart valve repair and replacement
- Open Access
- 7 February 2022
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 119 (6)
Poly-2-methyl-2-oxazoline–modified bioprosthetic heart valve leaflets have enhanced biocompatibility and resist structural degeneration
Significance: Heart valve disease affects millions, and since there is no effective medical therapy, surgical repair when possible—or more commonly, replacement—are the only treatments available. Bioprosthetic heart valves (BHV), the most frequently used valve replacements, are composed of heterograft tissue, typically fixed in glutaraldehyde, and prepared for human use either as surgically implantable devices or for transcatheter delivery. Protein-glycation limits the durability of BHV, contributing to device failure, often requiring reoperation after only a decade or less of functionality. This problem is addressed by modifying BHV leaflets with poly-2-methyl-2-oxazoline, effectively mitigating glycation and serum protein infiltration and enhancing biocompatibility.
- 7 February 2022
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 119 (6)
Open AccessPoly-2-methyl-2-oxazoline–modified bioprosthetic heart valve leaflets have enhanced biocompatibility and resist structural degeneration
Significance: Heart valve disease affects millions, and since there is no effective medical therapy, surgical repair when possible—or more commonly, replacement—are the only treatments available. Bioprosthetic heart valves (BHV), the most frequently used valve replacements, are composed of heterograft tissue, typically fixed in glutaraldehyde, and prepared for human use either as surgically implantable devices or for transcatheter delivery. Protein-glycation limits the durability of BHV, contributing to device failure, often requiring reoperation after only a decade or less of functionality. This problem is addressed by modifying BHV leaflets with poly-2-methyl-2-oxazoline, effectively mitigating glycation and serum protein infiltration and enhancing biocompatibility.
- 20 January 2022
- Published by Oxford University Press (OUP) in Cardiovascular Research
- Vol. 119 (1) , 302-315
Age-related enhanced degeneration of bioprosthetic valves due to leaflet calcification, tissue crosslinking, and structural changes
Bioprosthetic heart valves (BHVs), made from glutaraldehyde-fixed heterograft materials, are subject to more rapid structural valve degeneration (SVD) in paediatric and young adult patients. Differences in blood biochemistries and propensity for disease accelerate SVD in these patients, which results in multiple re-operations with compounding risks. The goal of this study is to investigate the mechanisms of BHV biomaterial degeneration and present models for studying SVD in young patients and juvenile animal models. We studied SVD in clinical BHV explants from paediatric and young adult patients, juvenile sheep implantation model, rat subcutaneous implants, and an ex vivo serum incubation model. BHV biomaterials were analysed for calcification, collagen microstructure (alignment and crimp), and crosslinking density. Serum markers of calcification and tissue crosslinking were compared between young and adult subjects. We demonstrated that immature subjects were more susceptible to calcification, microstructural changes, and advanced glycation end products formation. In vivo and ex vivo studies comparing immature and mature subjects mirrored SVD in clinical observations. The interaction between host serum and BHV biomaterials leads to significant structural and biochemical changes which impact their functions. There is an increased risk for accelerated SVD in younger subjects, both experimental animals and patients. Increased calcification, altered collagen microstructure with loss of alignment and increased crimp periods, and increased crosslinking are three main characteristics in BHV explants from young subjects leading to SVD. Together, our studies establish a basis for assessing the increased susceptibility of BHV biomaterials to accelerated SVD in young patients.
- 20 January 2022
- Published by Oxford University Press (OUP) in Cardiovascular Research
- Vol. 119 (1) , 302-315
Age-related enhanced degeneration of bioprosthetic valves due to leaflet calcification, tissue crosslinking, and structural changes
Bioprosthetic heart valves (BHVs), made from glutaraldehyde-fixed heterograft materials, are subject to more rapid structural valve degeneration (SVD) in paediatric and young adult patients. Differences in blood biochemistries and propensity for disease accelerate SVD in these patients, which results in multiple re-operations with compounding risks. The goal of this study is to investigate the mechanisms of BHV biomaterial degeneration and present models for studying SVD in young patients and juvenile animal models. We studied SVD in clinical BHV explants from paediatric and young adult patients, juvenile sheep implantation model, rat subcutaneous implants, and an ex vivo serum incubation model. BHV biomaterials were analysed for calcification, collagen microstructure (alignment and crimp), and crosslinking density. Serum markers of calcification and tissue crosslinking were compared between young and adult subjects. We demonstrated that immature subjects were more susceptible to calcification, microstructural changes, and advanced glycation end products formation. In vivo and ex vivo studies comparing immature and mature subjects mirrored SVD in clinical observations. The interaction between host serum and BHV biomaterials leads to significant structural and biochemical changes which impact their functions. There is an increased risk for accelerated SVD in younger subjects, both experimental animals and patients. Increased calcification, altered collagen microstructure with loss of alignment and increased crimp periods, and increased crosslinking are three main characteristics in BHV explants from young subjects leading to SVD. Together, our studies establish a basis for assessing the increased susceptibility of BHV biomaterials to accelerated SVD in young patients.
- Open Access
RAGE antagonist peptide mitigates AGE-mediated endothelial hyperpermeability and accumulation of glycoxidation products in human ascending aortas and in a murine model of aortic aneurysm
Background: Aortic dissection and aneurysm are the result of altered biomechanical forces associated with structural weakening of the aortic wall caused by genetic or acquired factors. Current guidelines recommend replacement of the ascending aorta when the diameter is >5.5 cm in tricuspid aortic valve patients. Aortopathies are associated with altered wall stress and stiffness as well as endothelial cell dysfunction and synthetic vascular smooth muscle cell (VSMC) phenotype. We reported that these mechanisms are mediated by glycoxidation products [Reactive oxygen species (ROS) and Advance Glycation End products (AGE)]. This study addresses the role of glycoxidation on endothelial function and AGE-mediated aortic stiffness. Hypothesis and aims: Here we investigate how circulating glycation products infiltrate the aortic wall via AGE-mediated endothelial hyperpermeability and contribute to both VSMC synthetic phenotype and extracellular matrix (ECM) remodeling in vivo and ex vivo . We also study how RAGE antagonist peptide (RAP) can rescue the effect of AGEs in vitro and in vivo in eNOS −/− vs WT mice. Methods and results: Human ascending aortas (n=30) were analyzed for AGE, ROS, and ECM markers. In vitro glycation was obtained by treating VSMC or human and murine aortas with glyoxal. Endothelial permeability was measured under glycation treatment. Vascular stiffness was measured by a pressure myograph comparing wild-type mice ± glyoxal. eNOS −/− mice, a model of increased endothelial permeability, were treated for 28 days with hyperlipidemic diet ± Angiotensin II (1000ng/kg/min) with or without anti-glycation treatment (RAP 20mg/kg). Echo data of aortic diameter were collected. Murine vascular stiffness was measured by a pressure myograph (n=5/group). Glycoxidation products were detected in all human aortas independently of aortic diameter, with stronger accumulation on the lumen and the adventitia layer. AGEs increased endothelial permeability, induce synthetic phenotypic switch in human VSMCs, and inhibit cell migration. RAP pre-treatment rescue the effect of glyoxal on endothelial cells. Ex vivo glycation treatment of murine arteries impacted on ECM and increased stiffness. Aortic stiffness was higher in eNOS −/− vs WT mice. Ang II-mediated aortopathies results in aortic dilation, and AGE/ROS accumulation, which is rescued by RAGE antagonist peptide treatment of eNOS −/− mice. Conclusions: Glycoxidation reaction mediate EC permeability, VSMCs phenotype, and ECM remodeling leading to dysfunctional microstructure of the ascending aorta, altered vascular stiffness and increasing aortic susceptibility to dilation and rupture. Moreover, we show that RAP can mitigate AGE-mediated endothelial hyper-permeability in vitro and impact on ascending aneurysm in vivo
Open AccessRAGE antagonist peptide mitigates AGE-mediated endothelial hyperpermeability and accumulation of glycoxidation products in human ascending aortas and in a murine model of aortic aneurysm
Background: Aortic dissection and aneurysm are the result of altered biomechanical forces associated with structural weakening of the aortic wall caused by genetic or acquired factors. Current guidelines recommend replacement of the ascending aorta when the diameter is >5.5 cm in tricuspid aortic valve patients. Aortopathies are associated with altered wall stress and stiffness as well as endothelial cell dysfunction and synthetic vascular smooth muscle cell (VSMC) phenotype. We reported that these mechanisms are mediated by glycoxidation products [Reactive oxygen species (ROS) and Advance Glycation End products (AGE)]. This study addresses the role of glycoxidation on endothelial function and AGE-mediated aortic stiffness. Hypothesis and aims: Here we investigate how circulating glycation products infiltrate the aortic wall via AGE-mediated endothelial hyperpermeability and contribute to both VSMC synthetic phenotype and extracellular matrix (ECM) remodeling in vivo and ex vivo . We also study how RAGE antagonist peptide (RAP) can rescue the effect of AGEs in vitro and in vivo in eNOS −/− vs WT mice. Methods and results: Human ascending aortas (n=30) were analyzed for AGE, ROS, and ECM markers. In vitro glycation was obtained by treating VSMC or human and murine aortas with glyoxal. Endothelial permeability was measured under glycation treatment. Vascular stiffness was measured by a pressure myograph comparing wild-type mice ± glyoxal. eNOS −/− mice, a model of increased endothelial permeability, were treated for 28 days with hyperlipidemic diet ± Angiotensin II (1000ng/kg/min) with or without anti-glycation treatment (RAP 20mg/kg). Echo data of aortic diameter were collected. Murine vascular stiffness was measured by a pressure myograph (n=5/group). Glycoxidation products were detected in all human aortas independently of aortic diameter, with stronger accumulation on the lumen and the adventitia layer. AGEs increased endothelial permeability, induce synthetic phenotypic switch in human VSMCs, and inhibit cell migration. RAP pre-treatment rescue the effect of glyoxal on endothelial cells. Ex vivo glycation treatment of murine arteries impacted on ECM and increased stiffness. Aortic stiffness was higher in eNOS −/− vs WT mice. Ang II-mediated aortopathies results in aortic dilation, and AGE/ROS accumulation, which is rescued by RAGE antagonist peptide treatment of eNOS −/− mice. Conclusions: Glycoxidation reaction mediate EC permeability, VSMCs phenotype, and ECM remodeling leading to dysfunctional microstructure of the ascending aorta, altered vascular stiffness and increasing aortic susceptibility to dilation and rupture. Moreover, we show that RAP can mitigate AGE-mediated endothelial hyper-permeability in vitro and impact on ascending aneurysm in vivo
- 8 April 2021
- Published by Wolters Kluwer Health in Arteriosclerosis, Thrombosis, and Vascular Biology
- Vol. 41 (6) , 2049-2062
Altered Responsiveness to TGFβ and BMP and Increased CD45+ Cell Presence in Mitral Valves Are Unique Features of Ischemic Mitral Regurgitation
Objective: Ischemic mitral regurgitation (IMR) often develops after an ischemic event, which results in distortion of the valvulo-ventricular complex and incomplete mitral valve (MV) leaflet coaptation. After left ventricular ischemic events, only some patients develop IMR. The susceptibility of the MV to remodel may influence whether IMR develops. We hypothesized that impaired signaling response in MV cells may contribute to IMR development by inducing maladaptive tissue remodeling. Approach and Results: Sheep (n=14) were subjected to ligation of the circumflex coronary artery to induce myocardial infarction. IMR was reported by echocardiography. MV leaflets and MV interstitial cells (MVICs) were collected at baseline (control, n=10), 4 and 8 weeks post-myocardial infarction. RNA sequencing highlighted differences in TGFβ (transforming growth factor beta) signaling between MV with/without IMR. SMAD6/7 and ID2 (inhibitor of DNA binding 2) were the highest increased TGFβ-signaling genes associated with IMR. MVICs from myocardial infarction sheep were less responsive to BMP (bone morphogenic protein) 4 pro-osteogenic stimulation (ID2, OPN [osteopontin], and OC [osteocalcin] mRNA) than control. MVICs from IMR sheep had a diminished COL (collagen) 1A1 mRNA response to TGFβ1 and enhanced prochondrogenic RUNX2 (runt-related transcription factor 2) and SOX9 mRNA response to BMP4 versus non-IMR MVICs. Baseline CD45 (cluster of differentiation) expression was detectable only in IMR MVICs. Upon TGFβ1 stimulation, CD45 expression was detected in all groups. Immunostaining confirmed increased presence of CD45+ cells in IMR MV interstitium. Conclusions: MVs from sheep with IMR had an altered TGFβ/BMP response, associated with increased CD45+ cell presence within the tissue interstitium. Pharmacological strategies aimed to modulate TGFβ/BMP signaling after myocardial infarction may protect from pathological MV remodeling leading to IMR.
- 8 April 2021
- Published by Wolters Kluwer Health in Arteriosclerosis, Thrombosis, and Vascular Biology
- Vol. 41 (6) , 2049-2062
Altered Responsiveness to TGFβ and BMP and Increased CD45+ Cell Presence in Mitral Valves Are Unique Features of Ischemic Mitral Regurgitation
Objective: Ischemic mitral regurgitation (IMR) often develops after an ischemic event, which results in distortion of the valvulo-ventricular complex and incomplete mitral valve (MV) leaflet coaptation. After left ventricular ischemic events, only some patients develop IMR. The susceptibility of the MV to remodel may influence whether IMR develops. We hypothesized that impaired signaling response in MV cells may contribute to IMR development by inducing maladaptive tissue remodeling. Approach and Results: Sheep (n=14) were subjected to ligation of the circumflex coronary artery to induce myocardial infarction. IMR was reported by echocardiography. MV leaflets and MV interstitial cells (MVICs) were collected at baseline (control, n=10), 4 and 8 weeks post-myocardial infarction. RNA sequencing highlighted differences in TGFβ (transforming growth factor beta) signaling between MV with/without IMR. SMAD6/7 and ID2 (inhibitor of DNA binding 2) were the highest increased TGFβ-signaling genes associated with IMR. MVICs from myocardial infarction sheep were less responsive to BMP (bone morphogenic protein) 4 pro-osteogenic stimulation (ID2, OPN [osteopontin], and OC [osteocalcin] mRNA) than control. MVICs from IMR sheep had a diminished COL (collagen) 1A1 mRNA response to TGFβ1 and enhanced prochondrogenic RUNX2 (runt-related transcription factor 2) and SOX9 mRNA response to BMP4 versus non-IMR MVICs. Baseline CD45 (cluster of differentiation) expression was detectable only in IMR MVICs. Upon TGFβ1 stimulation, CD45 expression was detected in all groups. Immunostaining confirmed increased presence of CD45+ cells in IMR MV interstitium. Conclusions: MVs from sheep with IMR had an altered TGFβ/BMP response, associated with increased CD45+ cell presence within the tissue interstitium. Pharmacological strategies aimed to modulate TGFβ/BMP signaling after myocardial infarction may protect from pathological MV remodeling leading to IMR.
- Open Access
- 2 February 2021
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 10 (3) , e018921
Noncalcific Mechanisms of Bioprosthetic Structural Valve Degeneration
Bioprosthetic heart valves (BHVs) largely circumvent the need for long‐term anticoagulation compared with mechanical valves but are increasingly susceptible to deterioration and reduced durability with reoperation rates of ≈10% and 30% at 10 and 15 years, respectively. Structural valve degeneration is a common, unpreventable, and untreatable consequence of BHV implantation and is frequently characterized by leaflet calcification. However, 25% of BHV reoperations attributed to structural valve degeneration occur with minimal leaflet mineralization. This review discusses the noncalcific mechanisms of BHV structural valve degeneration, highlighting the putative roles and pathophysiological relationships between protein infiltration, glycation, oxidative and mechanical stress, and inflammation and the structural consequences for surgical and transcatheter BHVs.
- 2 February 2021
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 10 (3) , e018921
Open AccessNoncalcific Mechanisms of Bioprosthetic Structural Valve Degeneration
Bioprosthetic heart valves (BHVs) largely circumvent the need for long‐term anticoagulation compared with mechanical valves but are increasingly susceptible to deterioration and reduced durability with reoperation rates of ≈10% and 30% at 10 and 15 years, respectively. Structural valve degeneration is a common, unpreventable, and untreatable consequence of BHV implantation and is frequently characterized by leaflet calcification. However, 25% of BHV reoperations attributed to structural valve degeneration occur with minimal leaflet mineralization. This review discusses the noncalcific mechanisms of BHV structural valve degeneration, highlighting the putative roles and pathophysiological relationships between protein infiltration, glycation, oxidative and mechanical stress, and inflammation and the structural consequences for surgical and transcatheter BHVs.
- Open Access
- 1 August 2020
- Published by Elsevier in JACC: Basic To Translational Science
- Vol. 5 (8) , 755-766
Glycation and Serum Albumin Infiltration Contribute to the Structural Degeneration of Bioprosthetic Heart Valves
- 1 August 2020
- Published by Elsevier in JACC: Basic To Translational Science
- Vol. 5 (8) , 755-766
Open AccessGlycation and Serum Albumin Infiltration Contribute to the Structural Degeneration of Bioprosthetic Heart Valves
- 9 October 2019
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 31 (1) , 94-106
Valve leaflet‐inspired elastomeric scaffolds with tunable and anisotropic mechanical properties
Fibrous scaffolds, which can mimic the elastic and anisotropic mechanical properties of native tissues, hold great promise in recapitulating the native tissue microenvironment. We previously fabricated electrospun fibrous scaffolds made of hybrid synthetic elastomers (poly(1,3‐diamino‐2‐hydroxypropane‐co‐glycerol sebacate)‐co‐poly (ethylene glycol) (APS‐co‐PEG) and polycaprolactone (PCL)) to obtain uniaxial mechanical properties similar to those of human aortic valve leaflets. However, conventional electrospinning process often yields scaffolds with random alignment, which fails to recreate the anisotropic nature of most of the soft tissues such as native heart valves. Inspired by the structure of native valve leaflet, we designed a novel valve leaflet‐inspired ring‐shaped collector to modulate the electrospun fiber alignment and studied the effect of polymer formulation (PEG amount [mole %] in APS‐co‐PEG; ratio between APS‐co‐PEG and PCL; and total polymer concentration) in tuning the biaxial mechanical properties of the fibrous scaffolds. The fibrous scaffolds collected on the ring‐shaped collector displayed anisotropic biaxial mechanical properties, suggesting that their biaxial mechanical properties are closely associated with the fiber alignment in the scaffold. Additionally, the scaffold stiffness was easily tuned by changing the composition and concentration of the polymer blend. Human valvular interstitial cells (hVICs) cultured on these anisotropic scaffolds displayed aligned morphology as instructed by the fiber alignment. Overall, we generated a library of biologically relevant fibrous scaffolds with tunable mechanical properties, which will guide the cellular alignment.
- 9 October 2019
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 31 (1) , 94-106
Valve leaflet‐inspired elastomeric scaffolds with tunable and anisotropic mechanical properties
Fibrous scaffolds, which can mimic the elastic and anisotropic mechanical properties of native tissues, hold great promise in recapitulating the native tissue microenvironment. We previously fabricated electrospun fibrous scaffolds made of hybrid synthetic elastomers (poly(1,3‐diamino‐2‐hydroxypropane‐co‐glycerol sebacate)‐co‐poly (ethylene glycol) (APS‐co‐PEG) and polycaprolactone (PCL)) to obtain uniaxial mechanical properties similar to those of human aortic valve leaflets. However, conventional electrospinning process often yields scaffolds with random alignment, which fails to recreate the anisotropic nature of most of the soft tissues such as native heart valves. Inspired by the structure of native valve leaflet, we designed a novel valve leaflet‐inspired ring‐shaped collector to modulate the electrospun fiber alignment and studied the effect of polymer formulation (PEG amount [mole %] in APS‐co‐PEG; ratio between APS‐co‐PEG and PCL; and total polymer concentration) in tuning the biaxial mechanical properties of the fibrous scaffolds. The fibrous scaffolds collected on the ring‐shaped collector displayed anisotropic biaxial mechanical properties, suggesting that their biaxial mechanical properties are closely associated with the fiber alignment in the scaffold. Additionally, the scaffold stiffness was easily tuned by changing the composition and concentration of the polymer blend. Human valvular interstitial cells (hVICs) cultured on these anisotropic scaffolds displayed aligned morphology as instructed by the fiber alignment. Overall, we generated a library of biologically relevant fibrous scaffolds with tunable mechanical properties, which will guide the cellular alignment.
- 16 July 2018
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 115 (10) , 2654-2667
Hierarchically aligned fibrous hydrogel films through microfluidic self‐assembly of graphene and polysaccharides
Despite significant interest in developing extracellular matrix (ECM)‐inspired biomaterials to recreate native cell‐instructive microenvironments, the major challenge in the biomaterial field is to recapitulate the complex structural and biophysical features of native ECM. These biophysical features include multiscale hierarchy, electrical conductivity, optimum wettability, and mechanical properties. These features are critical to the design of cell‐instructive biomaterials for bioengineering applications such as skeletal muscle tissue engineering. In this study, we used a custom‐designed film fabrication assembly, which consists of a microfluidic chamber to allow electrostatic charge‐based self‐assembly of oppositely charged polymer solutions forming a hydrogel fiber and eventually, a nanocomposite fibrous hydrogel film. The film recapitulates unidirectional hierarchical fibrous structure along with the conductive properties to guide initial alignment and myotube formation from cultured myoblasts. We combined high conductivity, and charge carrier mobility of graphene with biocompatibility of polysaccharides to develop graphene–polysaccharide nanocomposite fibrous hydrogel films. The incorporation of graphene in fibrous hydrogel films enhanced their wettability, electrical conductivity, tensile strength, and toughness without significantly altering their elastic properties (Young's modulus). In a proof‐of‐concept study, the mouse myoblast cells (C2C12) seeded on these nanocomposite fibrous hydrogel films showed improved spreading and enhanced myogenesis as evident by the formation of multinucleated myotubes, an early indicator of myogenesis. Overall, graphene–polysaccharide nanocomposite fibrous hydrogel films provide a potential biomaterial to promote skeletal muscle tissue regeneration.
- 16 July 2018
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 115 (10) , 2654-2667
Hierarchically aligned fibrous hydrogel films through microfluidic self‐assembly of graphene and polysaccharides
Despite significant interest in developing extracellular matrix (ECM)‐inspired biomaterials to recreate native cell‐instructive microenvironments, the major challenge in the biomaterial field is to recapitulate the complex structural and biophysical features of native ECM. These biophysical features include multiscale hierarchy, electrical conductivity, optimum wettability, and mechanical properties. These features are critical to the design of cell‐instructive biomaterials for bioengineering applications such as skeletal muscle tissue engineering. In this study, we used a custom‐designed film fabrication assembly, which consists of a microfluidic chamber to allow electrostatic charge‐based self‐assembly of oppositely charged polymer solutions forming a hydrogel fiber and eventually, a nanocomposite fibrous hydrogel film. The film recapitulates unidirectional hierarchical fibrous structure along with the conductive properties to guide initial alignment and myotube formation from cultured myoblasts. We combined high conductivity, and charge carrier mobility of graphene with biocompatibility of polysaccharides to develop graphene–polysaccharide nanocomposite fibrous hydrogel films. The incorporation of graphene in fibrous hydrogel films enhanced their wettability, electrical conductivity, tensile strength, and toughness without significantly altering their elastic properties (Young's modulus). In a proof‐of‐concept study, the mouse myoblast cells (C2C12) seeded on these nanocomposite fibrous hydrogel films showed improved spreading and enhanced myogenesis as evident by the formation of multinucleated myotubes, an early indicator of myogenesis. Overall, graphene–polysaccharide nanocomposite fibrous hydrogel films provide a potential biomaterial to promote skeletal muscle tissue regeneration.