Mushtaq Ismael Hasan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mushtaq Ismael Hasan has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Hind Lafta Tbena
Mechanical Engineering Department, College of Engineering, Thi-Qar University, Iraq
3 shared publicationsAhmed O. Shdhan
Mechanical Engineering Department, College of Engineering, Wasit University, Iraq
2 shared publicationsGhassan Adnan Abid
2 shared publicationsHadi O. Basher
Mechanical Engineering Department, College of Engineering, Wasit University, Iraq
2 shared publicationsSajad W. Noori
Mechanical Engineering Department, College of Engineering Thi‐Qar University Nasiriyah Iraq
2 shared publicationsA.A. Rageb
1 shared publication
Latest Publications
- Open Access
- 1 June 2025
- Published by Thi-Qar University Journal for Engineering Sciences in University of Thi-Qar Journal for Engineering Sciences
- Vol. 15 (1) , 23-37
Modeling and design procedure for LiBr-water absorption air-conditioning by solar energy
The aim of this study is to design a lithium bromide-water (LiBr-H2O) absorption cooling system with a rated capacity of about 1 kW of solar-powered cooling using lithium bromide as an adsorbent and water as a refrigerant. The proposed absorption cooling system consists of a rooftop evacuated tube solar collector, a LiBr-H2O single-effect absorption chiller (including a generator, a solution heat exchanger, an evaporator, a condenser, and an absorber), a fan coil unit, pumps, a flow choke, and control valves. All the governing thermal equations of the system were studied theoretically, and the system was designed according to the following assumptions (system capacity 1 kW, generator temperature 85 , condenser temperature 38 , evaporator temperature 5 , and absorber temperature 37 . To find out how different operational and design factors affect the thermal efficiency, a thermodynamic analysis of the absorption cooling cycle was performed. The dimensions of the components and the cooling capacity were explored in the results.
- 1 June 2025
- Published by Thi-Qar University Journal for Engineering Sciences in University of Thi-Qar Journal for Engineering Sciences
- Vol. 15 (1) , 23-37
Open AccessModeling and design procedure for LiBr-water absorption air-conditioning by solar energy
The aim of this study is to design a lithium bromide-water (LiBr-H2O) absorption cooling system with a rated capacity of about 1 kW of solar-powered cooling using lithium bromide as an adsorbent and water as a refrigerant. The proposed absorption cooling system consists of a rooftop evacuated tube solar collector, a LiBr-H2O single-effect absorption chiller (including a generator, a solution heat exchanger, an evaporator, a condenser, and an absorber), a fan coil unit, pumps, a flow choke, and control valves. All the governing thermal equations of the system were studied theoretically, and the system was designed according to the following assumptions (system capacity 1 kW, generator temperature 85 , condenser temperature 38 , evaporator temperature 5 , and absorber temperature 37 . To find out how different operational and design factors affect the thermal efficiency, a thermodynamic analysis of the absorption cooling cycle was performed. The dimensions of the components and the cooling capacity were explored in the results.
- Open Access
- 24 July 2021
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 84 (2) , 167-184
Numerical Investigation of The Air Flow Rate Effect Performance of Earth to Air Heat Exchanger Used for Cooling of Poultry Houses
Usually, poultry houses are located in a remote area where there is no electricity, and where there is electricity, it is expensive, so resorting to these solutions is considered important solutions to save electrical energy and provide free cooling. The main part of generated energy is consumed by cooling and heating systems. One of the well-known approaches to implemented heating and cooling system is earth to air heat exchanger (EAHE) system. This system is effective passive heating and cooling systems which can be used with poultry houses and building. This research studies numerically the effect of mass flow rate on the overall performance of earth to air HE for poultry houses. Four parameters (mass flow rate, required rate, required cooling load and pipe lengths) are selected under environment of Nasiriyah city (a city located in the south of Iraq). The study is conducted using PVC material. The study has been done during summer season. The suggested numerical model has been tested and validated using existing approaches selected from literature review papers. This test shows good agreement with results of selected papers. Moreover, validation and simulation results showed that the required cooling load increased with increasing mass flow rate. Also, with the increasing length of pipe of EAHE, the inflow temperature compared to the space temperature is decreased. However, the overall performance factor of EAHEs decreases by the increase of length of pipe and mass flow rate. Which indicate the possibility of using the earth to air heat exchanger for cooling and heating poultry houses and reduce the use of electrical energy.
- 24 July 2021
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 84 (2) , 167-184
Open AccessNumerical Investigation of The Air Flow Rate Effect Performance of Earth to Air Heat Exchanger Used for Cooling of Poultry Houses
Usually, poultry houses are located in a remote area where there is no electricity, and where there is electricity, it is expensive, so resorting to these solutions is considered important solutions to save electrical energy and provide free cooling. The main part of generated energy is consumed by cooling and heating systems. One of the well-known approaches to implemented heating and cooling system is earth to air heat exchanger (EAHE) system. This system is effective passive heating and cooling systems which can be used with poultry houses and building. This research studies numerically the effect of mass flow rate on the overall performance of earth to air HE for poultry houses. Four parameters (mass flow rate, required rate, required cooling load and pipe lengths) are selected under environment of Nasiriyah city (a city located in the south of Iraq). The study is conducted using PVC material. The study has been done during summer season. The suggested numerical model has been tested and validated using existing approaches selected from literature review papers. This test shows good agreement with results of selected papers. Moreover, validation and simulation results showed that the required cooling load increased with increasing mass flow rate. Also, with the increasing length of pipe of EAHE, the inflow temperature compared to the space temperature is decreased. However, the overall performance factor of EAHEs decreases by the increase of length of pipe and mass flow rate. Which indicate the possibility of using the earth to air heat exchanger for cooling and heating poultry houses and reduce the use of electrical energy.
- Open Access
- 1 February 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1773 (1) , 012021
Theoretical study the effect of dispersion of nanoparticles on thermo-physical characteristics of PCM with micro-channel heat sink
Thermal performance of micro-channel heat sink (MHS) with different cooling mediums has been investigated numerically using 3D model of conjugated heat transfer. Four types of coolants have been used in this study starting with air as a baseline to compare its thermal performance with pure phase change material (PCM) which was paraffin wax and nanoparticles-enhanced phase change material (NEPCM) which were (Silicon carbide (Sic)-PCM and Diamond-PCM) with volume fraction values of (1, 3, and 5%). On the heat sink base, a constant and uniform heat flux of (8000, 10000, 12000, and 14000W.m−2) is applied. Numerical simulations have been performed to investigate the effect of nanoparticle material and concentrations of nanoparticles on cooling performance of heat sink. The findings elucidated the cooling performance of MHS is enhanced with PCM compared with air and suspension nanoparticles lead to improve the thermal conductivity of (NEPCM) comparing with pure PCM, that causing expedite the melting process and enhancement of cooling performance. Also, as the concentration of nanoparticles increased, the heat transfer rate for (NEPCM) enhanced and decreasing the time of the melting process.
- 1 February 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1773 (1) , 012021
Open AccessTheoretical study the effect of dispersion of nanoparticles on thermo-physical characteristics of PCM with micro-channel heat sink
Thermal performance of micro-channel heat sink (MHS) with different cooling mediums has been investigated numerically using 3D model of conjugated heat transfer. Four types of coolants have been used in this study starting with air as a baseline to compare its thermal performance with pure phase change material (PCM) which was paraffin wax and nanoparticles-enhanced phase change material (NEPCM) which were (Silicon carbide (Sic)-PCM and Diamond-PCM) with volume fraction values of (1, 3, and 5%). On the heat sink base, a constant and uniform heat flux of (8000, 10000, 12000, and 14000W.m−2) is applied. Numerical simulations have been performed to investigate the effect of nanoparticle material and concentrations of nanoparticles on cooling performance of heat sink. The findings elucidated the cooling performance of MHS is enhanced with PCM compared with air and suspension nanoparticles lead to improve the thermal conductivity of (NEPCM) comparing with pure PCM, that causing expedite the melting process and enhancement of cooling performance. Also, as the concentration of nanoparticles increased, the heat transfer rate for (NEPCM) enhanced and decreasing the time of the melting process.
- 27 August 2019
- Published by Wiley in Heat Transfer
- Vol. 48 (8) , 3902-3927
A study of the potential of using the Earth to air heat exchanger for cooling and heating of residential buildings in Iraq
The Earth to air heat exchanger (EAHE) is an effective passive cooling and heating system for buildings. This paper studied numerically the potential for reduction in energy consumption for cooling and heating loads for a residence equipped with an EAHE system in the climate of Nasiriya city, which is located in southern Iraq and at 31.7°N and 45.8°E, latitude and longitude, respectively. Also, this paper presents a study about the thermal performance of three types of EAHE systems, system 1, consisting of one layer of EAHE and buried at an available area of house garden with 3‐m depth, system 2, at the same site of system 1, but with two layers of EAHE at two depths, 3 and 4 m, and finally, system 3, buried along the area of the house at a depth of 3 m. First, the built numerical model was validated against experimental results, and the results of the comparison showed good agreement. The electricity consumption for cooling and heating of the house is calculated with and without the EAHE system. The results showed that with using EAHE, there is a considerable saving in energy and saving in the cost of electricity consumption, which reached 376 329 IQD ($301.11) over 1 year for system 2.
- 27 August 2019
- Published by Wiley in Heat Transfer
- Vol. 48 (8) , 3902-3927
A study of the potential of using the Earth to air heat exchanger for cooling and heating of residential buildings in Iraq
The Earth to air heat exchanger (EAHE) is an effective passive cooling and heating system for buildings. This paper studied numerically the potential for reduction in energy consumption for cooling and heating loads for a residence equipped with an EAHE system in the climate of Nasiriya city, which is located in southern Iraq and at 31.7°N and 45.8°E, latitude and longitude, respectively. Also, this paper presents a study about the thermal performance of three types of EAHE systems, system 1, consisting of one layer of EAHE and buried at an available area of house garden with 3‐m depth, system 2, at the same site of system 1, but with two layers of EAHE at two depths, 3 and 4 m, and finally, system 3, buried along the area of the house at a depth of 3 m. First, the built numerical model was validated against experimental results, and the results of the comparison showed good agreement. The electricity consumption for cooling and heating of the house is calculated with and without the EAHE system. The results showed that with using EAHE, there is a considerable saving in energy and saving in the cost of electricity consumption, which reached 376 329 IQD ($301.11) over 1 year for system 2.
- 4 July 2019
- Published by Wiley in Heat Transfer
- Vol. 48 (6) , 2440-2455
Modifying the thermal performance of electrical distribution transformers using phase change materials (paraffin wax)
In this paper, an electrical distribution transformer has been studied experimentally and a novel technique has been proposed to enhance its cooling performance by addition of paraffin wax to transformer oil using closed containers made of aluminum. These containers were immersed in the transformer oil. A 100 kVA transformer was used as a model for study because these transformers are widely used in the electricity distribution network in Iraq. As temperature rises, the phase change material (paraffin wax) absorbs heat and melts inside the containers at a constant temperature. This feature can be utilized to store heat for a period until the temperature for weather drops; then this heat is rejected, and the wax begins to solidify. In this experiment, five containers were used, each containing 2 kg of wax. The results showed a clear decrease in the temperature of the oil, which led to the enhancment of its thermal insulation and kept the oil from failure and the preserved the transformer from breakdown. The results showed that the reduction in temperature is approximately 7°C and the reduction increased upon increasing the amount of wax added.
- 4 July 2019
- Published by Wiley in Heat Transfer
- Vol. 48 (6) , 2440-2455
Modifying the thermal performance of electrical distribution transformers using phase change materials (paraffin wax)
In this paper, an electrical distribution transformer has been studied experimentally and a novel technique has been proposed to enhance its cooling performance by addition of paraffin wax to transformer oil using closed containers made of aluminum. These containers were immersed in the transformer oil. A 100 kVA transformer was used as a model for study because these transformers are widely used in the electricity distribution network in Iraq. As temperature rises, the phase change material (paraffin wax) absorbs heat and melts inside the containers at a constant temperature. This feature can be utilized to store heat for a period until the temperature for weather drops; then this heat is rejected, and the wax begins to solidify. In this experiment, five containers were used, each containing 2 kg of wax. The results showed a clear decrease in the temperature of the oil, which led to the enhancment of its thermal insulation and kept the oil from failure and the preserved the transformer from breakdown. The results showed that the reduction in temperature is approximately 7°C and the reduction increased upon increasing the amount of wax added.
- Open Access
- 1 June 2019
- Published by Thi-Qar University Journal for Engineering Sciences in University of Thi-Qar Journal for Engineering Sciences
- Vol. 10 (1) , 101-113
Numerical investigation the performance of micro channel heat sink with different cooling mediums
This study aims to study the effect of different cooling fluids (pure fluids, Nanofluids and microencapsulated phase change materials suspensions) and the cooling performance of rectangular micro-channel heat sink. Three types of Nanofluids (Al2O3-water, Cu-water,Tio2-water), three types of microencapsulated phase change materials suspensions(MEPCM) are(RT44-water, paraffin wax water, n-octed-water ) and three pure fluids )Water, Oil ,Ethylene Glycol ) were used with constant heat flux(100 W /cm2 ) applied on the base of heat sink. The volumetric concentrations of Nanofluids and MEPCM suspensions (1%, 3%, and 5%) and (100 to 900) is the range of Reynolds number used in this study. The results showed that, using different types of Nanofluids and MEPCM suspensions lead to enhance the cooling performance of the micro channel heat sink (MCHS), since it lead to increase the heat transfer compared with pure fluids. The heat transfer in (MCHS) for MEPCMs is higher than that for Nanofluids. Also, the performance of heat sink increases with increase the concentration of Nanofluids and MEPCMS at certain volumetric concentration
- 1 June 2019
- Published by Thi-Qar University Journal for Engineering Sciences in University of Thi-Qar Journal for Engineering Sciences
- Vol. 10 (1) , 101-113
Open AccessNumerical investigation the performance of micro channel heat sink with different cooling mediums
This study aims to study the effect of different cooling fluids (pure fluids, Nanofluids and microencapsulated phase change materials suspensions) and the cooling performance of rectangular micro-channel heat sink. Three types of Nanofluids (Al2O3-water, Cu-water,Tio2-water), three types of microencapsulated phase change materials suspensions(MEPCM) are(RT44-water, paraffin wax water, n-octed-water ) and three pure fluids )Water, Oil ,Ethylene Glycol ) were used with constant heat flux(100 W /cm2 ) applied on the base of heat sink. The volumetric concentrations of Nanofluids and MEPCM suspensions (1%, 3%, and 5%) and (100 to 900) is the range of Reynolds number used in this study. The results showed that, using different types of Nanofluids and MEPCM suspensions lead to enhance the cooling performance of the micro channel heat sink (MCHS), since it lead to increase the heat transfer compared with pure fluids. The heat transfer in (MCHS) for MEPCMs is higher than that for Nanofluids. Also, the performance of heat sink increases with increase the concentration of Nanofluids and MEPCMS at certain volumetric concentration
- Open Access
- 1 June 2019
- Published by University of Thi-Qar in University of Thi-Qar Journal for Engineering Sciences
- Vol. 10 (1) , 91-100
Study surface roughness on overall performance of parallel flow microchannel heat exchanger
The aim of this paper is to investigate numerically the surface roughness effects on the overall performance of parallel flow microchannel heat exchanger (PFMCHE) with different hydraulic diameters. Water has been used as working fluid flow velocities in one direction for hot and cold channels with square shape. Surface roughness considered in this study has been choiced as ratio with equal 0.14 of surface roughness to hydraulic diameter. The obtained results showed that, the pumping power increased with increasing effect of surface roughness and decreasing hydraulic diameter, also the thermal performance increased slightly with increasing surface roughness
- 1 June 2019
- Published by University of Thi-Qar in University of Thi-Qar Journal for Engineering Sciences
- Vol. 10 (1) , 91-100
Open AccessStudy surface roughness on overall performance of parallel flow microchannel heat exchanger
The aim of this paper is to investigate numerically the surface roughness effects on the overall performance of parallel flow microchannel heat exchanger (PFMCHE) with different hydraulic diameters. Water has been used as working fluid flow velocities in one direction for hot and cold channels with square shape. Surface roughness considered in this study has been choiced as ratio with equal 0.14 of surface roughness to hydraulic diameter. The obtained results showed that, the pumping power increased with increasing effect of surface roughness and decreasing hydraulic diameter, also the thermal performance increased slightly with increasing surface roughness
- 2 April 2019
- Published by Wiley in Heat Transfer
- Vol. 48 (5) , 1805-1829
Parametric study on the performance of the earth‐to‐air heat exchanger for cooling and heating applications
To reduce energy consumption, the earth‐to‐air heat exchanger (EAHE) is a suitable technique for cooling and heating buildings. This paper studies numerically the effect of some design parameters (pipe diameter, inlet condition, pipe length, and outlet condition) on the overall performance of the EAHE system. Four diameters of the EAHE pipe (2, 3, 4, and 6 in) are studied and this numerical study has been done for summer and winter seasons for Nasiriyah city in southern Iraq. First, the built numerical model was validated against the experimental model, and the results of comparison showed a good consensus. After the validation and by using computational fluid dynamics modeling, the overall performance of the EAHE system with all pipe diameters was analyzed with ranges of air velocity, DBT or inlet temperature, and a pipe length of 50 m. The simulated results showed that the EAHE system with 6 in pipe diameter has the best values of overall performance, but from the thermal performance point of view, the 2 in pipe diameter is more suitable.
- 2 April 2019
- Published by Wiley in Heat Transfer
- Vol. 48 (5) , 1805-1829
Parametric study on the performance of the earth‐to‐air heat exchanger for cooling and heating applications
To reduce energy consumption, the earth‐to‐air heat exchanger (EAHE) is a suitable technique for cooling and heating buildings. This paper studies numerically the effect of some design parameters (pipe diameter, inlet condition, pipe length, and outlet condition) on the overall performance of the EAHE system. Four diameters of the EAHE pipe (2, 3, 4, and 6 in) are studied and this numerical study has been done for summer and winter seasons for Nasiriyah city in southern Iraq. First, the built numerical model was validated against the experimental model, and the results of comparison showed a good consensus. After the validation and by using computational fluid dynamics modeling, the overall performance of the EAHE system with all pipe diameters was analyzed with ranges of air velocity, DBT or inlet temperature, and a pipe length of 50 m. The simulated results showed that the EAHE system with 6 in pipe diameter has the best values of overall performance, but from the thermal performance point of view, the 2 in pipe diameter is more suitable.
- Open Access
- 1 February 2019
- Published by Al-Qadisiyah Journal for Engineering Sciences (QJES) in Al-Qadisiyah Journal for Engineering Sciences
- Vol. 11 (4) , 426-445
NUMERICAL INVESTIGATION OF ROUGNESS EFFECTS ON HYDERDYNMIC AND THERMAL PERFORMANCE OF COUNTER FLOW MICROCHANNEL HEAT EXCHANGER
In this paper the effect of surface roughness on the performance of counter flow microchannel heat exchanger has been numerically investigated. The studied Microchannel heat exchanger is a square shape and made of aluminum as substrate material with different values of hydraulic diameters (20, 50, 110, 150 ) μm. The working fluid used is water at constant properties. Roughness- viscosity model has been used to study the roughness effect with 0.14 ratio of roughness to hydraulic diameter. The results obtained indicate that pressure drop of (CFMCHX) increased with increasing surface roughness and decrease hydraulic diameter also the results showed that there is a slight increasing in thermal performance with increasing the surface roughness.
- 1 February 2019
- Published by Al-Qadisiyah Journal for Engineering Sciences (QJES) in Al-Qadisiyah Journal for Engineering Sciences
- Vol. 11 (4) , 426-445
Open AccessNUMERICAL INVESTIGATION OF ROUGNESS EFFECTS ON HYDERDYNMIC AND THERMAL PERFORMANCE OF COUNTER FLOW MICROCHANNEL HEAT EXCHANGER
In this paper the effect of surface roughness on the performance of counter flow microchannel heat exchanger has been numerically investigated. The studied Microchannel heat exchanger is a square shape and made of aluminum as substrate material with different values of hydraulic diameters (20, 50, 110, 150 ) μm. The working fluid used is water at constant properties. Roughness- viscosity model has been used to study the roughness effect with 0.14 ratio of roughness to hydraulic diameter. The results obtained indicate that pressure drop of (CFMCHX) increased with increasing surface roughness and decrease hydraulic diameter also the results showed that there is a slight increasing in thermal performance with increasing the surface roughness.
- 30 August 2018
- Published by Wasit University in Wasit Journal of Engineering Sciences
- Vol. 6 (2) , 1-20
Numerical Investigation of Phase Change Materials for Insulation of Residential Buildings in Hot Regions in Iraqi cities
In this paper, numerical study has been conducted for using PCM as thermal insulation materials by incorporating it with layers of walls and ceiling of buildings. The effect of PCM and its role in improvement of thermal performance and thermal comfort is numerically studied. ESP-r software program has been used for numerical simulation in this paper. Energy plus weather database software was used to create climate date for Kut city (32.5 oN 45.8 oE) that used for simulation in this study. Two identical rooms were inserted in software ESP-r with dimensions (1.5m*1.5m*1m), the first is standard room for comparison and the second is test room for experimenting. Many cases were studied according to the thickness of the PCM and according to the orientation (North wall, South wall, East wall, West wall, and ceiling). Results obtained showed a reduction in indoor temperature of the zone and the reduction in the cooling load and as a result saving in electricity consumption with using PCM as insulation materials.
- 30 August 2018
- Published by Wasit University in Wasit Journal of Engineering Sciences
- Vol. 6 (2) , 1-20
Numerical Investigation of Phase Change Materials for Insulation of Residential Buildings in Hot Regions in Iraqi cities
In this paper, numerical study has been conducted for using PCM as thermal insulation materials by incorporating it with layers of walls and ceiling of buildings. The effect of PCM and its role in improvement of thermal performance and thermal comfort is numerically studied. ESP-r software program has been used for numerical simulation in this paper. Energy plus weather database software was used to create climate date for Kut city (32.5 oN 45.8 oE) that used for simulation in this study. Two identical rooms were inserted in software ESP-r with dimensions (1.5m*1.5m*1m), the first is standard room for comparison and the second is test room for experimenting. Many cases were studied according to the thickness of the PCM and according to the orientation (North wall, South wall, East wall, West wall, and ceiling). Results obtained showed a reduction in indoor temperature of the zone and the reduction in the cooling load and as a result saving in electricity consumption with using PCM as insulation materials.