Salih Fadil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Salih Fadil has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Burak Urazel
Eskisehir Osmangazi University
2 shared publications - Celal Yaşar
Kütahya Sağlık Bilimleri Üniversitesi
2 shared publications Burak Urazel
Eskisehir Osmangazi University, Faculty of Engineering, Department of Electrical Engineering, Eskisehir, Turkey
1 shared publicationCüneyt Demir
Department of Electrical Engineering, Eskişehir Osmangazi University, Meşelik, 26480 Eskişehir, Turkey
1 shared publicationMustafa Babadağı
Air Corps Schools and Technical Training Center, 35410, Gaziemir, İzmir, Turkey
1 shared publication
Latest Publications
- 1 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 505-509
Solution to short term hydrothermal scheduling problem by modified subgradient algorithm based on feasible values
In this paper, the modified subgradient algorithm based on feasible values (F-MSG) is applied to a short term hydrothermal coordination problem. Power system transmission loss is inserted into this model as equality constraints via load flow equations. Unit generation constraints, transmission line capacity constraints, bus voltage magnitude constraints, off nominal tap ratio constraints, SVAR system susceptances constraints, hydraulic units' minimum and maximum reservoir volume constraints, hydraulic units' starting and final reservoir volume constraints are also added into the optimization problem. Since all constraints in the nonlinear programming model are functions of complex bus voltages, off-nominal tap ratios and SVAR system susceptances (once there are off nominal tap changing transformers and SVAR systems in the power system), they are taken as independent variables. The proposed approach is tested on 16 bus test system where there are four serial-parallel hydraulically coupled hydro plants. The same dispatch problem was also solved by other dispatch techniques that use pseudo spot price algorithm and classical gradient method previously. Results obtained from those algorithms and F-MSG are also compared.
- 1 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 505-509
Solution to short term hydrothermal scheduling problem by modified subgradient algorithm based on feasible values
In this paper, the modified subgradient algorithm based on feasible values (F-MSG) is applied to a short term hydrothermal coordination problem. Power system transmission loss is inserted into this model as equality constraints via load flow equations. Unit generation constraints, transmission line capacity constraints, bus voltage magnitude constraints, off nominal tap ratio constraints, SVAR system susceptances constraints, hydraulic units' minimum and maximum reservoir volume constraints, hydraulic units' starting and final reservoir volume constraints are also added into the optimization problem. Since all constraints in the nonlinear programming model are functions of complex bus voltages, off-nominal tap ratios and SVAR system susceptances (once there are off nominal tap changing transformers and SVAR systems in the power system), they are taken as independent variables. The proposed approach is tested on 16 bus test system where there are four serial-parallel hydraulically coupled hydro plants. The same dispatch problem was also solved by other dispatch techniques that use pseudo spot price algorithm and classical gradient method previously. Results obtained from those algorithms and F-MSG are also compared.
- Open Access
- 22 September 2013
- Published by Wiley in ISRN Power Engineering
- Vol. 2013, 1-12
Solution to Security Constrained Environmental Pumped-Storage Hydraulic Unit Scheduling Problem by Genetic Algorithm
A lossy electric power system area that contains thermal units and a pumped-storage (p-s) hydraulic unit is considered in this paper. The cost function, which is weighted combination of the total fuel cost and the total emission cost of the thermal units, in an operation cycle, is minimized under some possible electric and hydraulic constraints. The dispatch technique that is based on genetic algorithm considers minimum and maximum reservoir storage limits of the p-s unit, upper and lower active and reactive generation limits of the thermal units, upper and lower active pumping/generation power limits of the p-s unit, maximum transmission capacities of the transmission lines, and upper and lower limits of the bus voltage magnitudes in a considered power system. The proposed dispatch technique was tested on an example power system that has 12 buses with five thermal units and a p-s hydraulic unit. The same dispatch problem is solved via an iterative solution method based on modified subgradient algorithm operating on feasible values (F-MSG) and pseudowater price just for comparison purpose. It is seen that the solution technique based on the F-MSG algorithm and pseudowater price gives similar results with the proposed algorithm based on genetic algorithm.
- 22 September 2013
- Published by Wiley in ISRN Power Engineering
- Vol. 2013, 1-12
Open AccessSolution to Security Constrained Environmental Pumped-Storage Hydraulic Unit Scheduling Problem by Genetic Algorithm
A lossy electric power system area that contains thermal units and a pumped-storage (p-s) hydraulic unit is considered in this paper. The cost function, which is weighted combination of the total fuel cost and the total emission cost of the thermal units, in an operation cycle, is minimized under some possible electric and hydraulic constraints. The dispatch technique that is based on genetic algorithm considers minimum and maximum reservoir storage limits of the p-s unit, upper and lower active and reactive generation limits of the thermal units, upper and lower active pumping/generation power limits of the p-s unit, maximum transmission capacities of the transmission lines, and upper and lower limits of the bus voltage magnitudes in a considered power system. The proposed dispatch technique was tested on an example power system that has 12 buses with five thermal units and a p-s hydraulic unit. The same dispatch problem is solved via an iterative solution method based on modified subgradient algorithm operating on feasible values (F-MSG) and pseudowater price just for comparison purpose. It is seen that the solution technique based on the F-MSG algorithm and pseudowater price gives similar results with the proposed algorithm based on genetic algorithm.
- 18 April 2007
- Published by Wiley in European Transactions on Electrical Power
- Vol. 18 (3) , 296-312
A spot price of electricity algorithm applied to lossy short‐term hydrothermal scheduling problem with limited energy supply thermal units
- 18 April 2007
- Published by Wiley in European Transactions on Electrical Power
- Vol. 18 (3) , 296-312
A spot price of electricity algorithm applied to lossy short‐term hydrothermal scheduling problem with limited energy supply thermal units
- 26 November 2001
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 24 (2) , 87-95
An active power dispatch technique using pseudo spot price of electricity for a power system area including limited energy supply thermal units
- 26 November 2001
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 24 (2) , 87-95
An active power dispatch technique using pseudo spot price of electricity for a power system area including limited energy supply thermal units