Sven Richter
Sven Richter has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Jochen Schuld
University of Saarland
2 shared publications A. Olinger
Abteilung für Unfall-, Hand- und Wiederherstellungschirurgie
1 shared publication- Brigitte Vollmar
University Medical Center Rostock
1 shared publication D. Igna
Departments of General, Visceral, Vascular and Paediatric Surgery, University of Saarland, Homburg/Saar, Germany
1 shared publicationJohannes P. Doberauer
Department of General and Visceral Surgery
1 shared publicationM. R. Moussavian
Departments of General, Visceral, Vascular and Paediatric Surgery, University of Saarland, Homburg/Saar, Germany
1 shared publication
Latest Publications
- Open Access
- 28 October 2013
- Published by Wiley in Gastroenterology Research and Practice
- Vol. 2013, 1-6
Negative Pressure Wound Therapy for the Treatment of the Open Abdomen and Incidence of Enteral Fistulas: A Retrospective Bicentre Analysis
Introduction.The open abdomen (OA) is often associated with complications. It has been hypothesized that negative pressure wound therapy (NPWT) in the treatment of OA may provoke enteral fistulas. Therefore, we analyzed patients with OA and NPWT with special regard to the occurrence of intestinal fistulas.Methods.The present study included all consecutive patients with OA treated with NWPT from April 2010 to August 2011 in two hospitals. Patients’ demographics, indications for OA, risk factors, complications, outcome and incidence of fistulas before, during and after NPWT were recorded.Results.Of 81 patients with OA, 26 had pre-existing fistulas and 55 were free from a fistula at the beginning of NPWT. Nine of the 55 patients developed fistulas during () or after NPWT (). Seventy-five patients received ABThera therapy, 6 patients other temporary abdominal closure devices. Only diverticulitis seemed to be a significant predisposing factor for fistulas. Mortality was slightly lower for patients without fistulas.Conclusion.The present study revealed no correlation between occurrence of fistulas before, during, and after NWPT, with diverticulitis being the only risk factor. Fistula formation during NPWT was comparable to reports from literature. Prospective studies are mandatory to clarify the impact of NPWT on fistula formation.
- 28 October 2013
- Published by Wiley in Gastroenterology Research and Practice
- Vol. 2013, 1-6
Open AccessNegative Pressure Wound Therapy for the Treatment of the Open Abdomen and Incidence of Enteral Fistulas: A Retrospective Bicentre Analysis
Introduction.The open abdomen (OA) is often associated with complications. It has been hypothesized that negative pressure wound therapy (NPWT) in the treatment of OA may provoke enteral fistulas. Therefore, we analyzed patients with OA and NPWT with special regard to the occurrence of intestinal fistulas.Methods.The present study included all consecutive patients with OA treated with NWPT from April 2010 to August 2011 in two hospitals. Patients’ demographics, indications for OA, risk factors, complications, outcome and incidence of fistulas before, during and after NPWT were recorded.Results.Of 81 patients with OA, 26 had pre-existing fistulas and 55 were free from a fistula at the beginning of NPWT. Nine of the 55 patients developed fistulas during () or after NPWT (). Seventy-five patients received ABThera therapy, 6 patients other temporary abdominal closure devices. Only diverticulitis seemed to be a significant predisposing factor for fistulas. Mortality was slightly lower for patients without fistulas.Conclusion.The present study revealed no correlation between occurrence of fistulas before, during, and after NWPT, with diverticulitis being the only risk factor. Fistula formation during NPWT was comparable to reports from literature. Prospective studies are mandatory to clarify the impact of NPWT on fistula formation.
- Open Access
- 29 April 2009
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 96 (6) , 593-601
Randomized clinical trial of efficacy and costs of three dissection devices in liver resection
Background: In recent decades a variety of instruments for liver dissection has become available. This randomized controlled trial analysed the efficacy and costs of three different liver dissection devices. Methods: Ninety‐six patients without cirrhosis undergoing liver resection were randomized to either ultrasonic dissection, waterjet dissection or dissecting sealer (32 in each group). Patients were unaware of the device used. The primary endpoint was dissection speed. Secondary endpoints were intraoperative blood loss, morbidity and mortality, and costs of dissection devices, staplers and haemostatic agents. Results: Dissection was slower with the dissecting sealer (P = 0·004 versus waterjet dissector). The difference was more pronounced for extended resections (mean(s.e.m.) 1·62(0·36) cm2/min versus 3·42(0·53) and 3·63(0·51) cm2/min for ultrasonic and water dissectors respectively; P = 0·037). Costs were significantly higher for the dissecting sealer when atypical or segmental resections were performed. Four patients died after extended resections; postoperative complications did not differ between groups. Conclusion: The dissecting sealer is slower than the ultrasonic dissector or water dissector. The three devices are equally safe in terms of blood loss, transfusions and postoperative complications. Ultrasonic and water dissectors might be more favourable economically than the dissecting sealer. Registration number: ISRCTN52294555 ( http://www.controlled‐trials.com). Copyright © 2009 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.
- 29 April 2009
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 96 (6) , 593-601
Open AccessRandomized clinical trial of efficacy and costs of three dissection devices in liver resection
Background: In recent decades a variety of instruments for liver dissection has become available. This randomized controlled trial analysed the efficacy and costs of three different liver dissection devices. Methods: Ninety‐six patients without cirrhosis undergoing liver resection were randomized to either ultrasonic dissection, waterjet dissection or dissecting sealer (32 in each group). Patients were unaware of the device used. The primary endpoint was dissection speed. Secondary endpoints were intraoperative blood loss, morbidity and mortality, and costs of dissection devices, staplers and haemostatic agents. Results: Dissection was slower with the dissecting sealer (P = 0·004 versus waterjet dissector). The difference was more pronounced for extended resections (mean(s.e.m.) 1·62(0·36) cm2/min versus 3·42(0·53) and 3·63(0·51) cm2/min for ultrasonic and water dissectors respectively; P = 0·037). Costs were significantly higher for the dissecting sealer when atypical or segmental resections were performed. Four patients died after extended resections; postoperative complications did not differ between groups. Conclusion: The dissecting sealer is slower than the ultrasonic dissector or water dissector. The three devices are equally safe in terms of blood loss, transfusions and postoperative complications. Ultrasonic and water dissectors might be more favourable economically than the dissecting sealer. Registration number: ISRCTN52294555 ( http://www.controlled‐trials.com). Copyright © 2009 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.