Ryo Itatani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ryo Itatani has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Kazuhiro Katahira
Department of Radiology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto, 862-0965, Japan
4 shared publicationsTomohiro Namimoto
Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Kumamoto, 860-8556, Japan
4 shared publicationsYasuyuki Yamashita
Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Kumamoto, 860-8556, Japan
4 shared publicationsKosuke Kitani
From the *Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University; Departments of †Radiology, ‡Urology, and §Pathology, Kumamoto Chuo Hospital; and ∥Department of Diagnostic Radiology, Amakusa Medical Center, Kumamoto, Japan
2 shared publicationsMitsuhiko Kitaoka
From the *Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University; Departments of †Radiology, ‡Urology, and §Pathology, Kumamoto Chuo Hospital; and ∥Department of Diagnostic Radiology, Amakusa Medical Center, Kumamoto, Japan
2 shared publicationsYasuyuki Hamada
From the *Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University; Departments of †Radiology, ‡Urology, and §Pathology, Kumamoto Chuo Hospital; and ∥Department of Diagnostic Radiology, Amakusa Medical Center, Kumamoto, Japan
2 shared publications
Latest Publications
- 7 January 2016
- Published by Springer Nature in Abdominal Radiology
- Vol. 41 (7) , 1285-1292
Clinical application of navigator-gated three-dimensional balanced turbo-field-echo magnetic resonance cholangiopancreatography at 3 T: prospective intraindividual comparison with 1.5 T
To evaluate and compare the clinical utility of balanced turbo-field-echo (BTFE) magnetic resonance cholangiopancreatography (MRCP) sequences obtained at 3 and 1.5 T. We acquired three-dimensional (3D) BTFE MRCP scans with a navigator-gated technique at 3 T on a different day after 1.5 T in 39 consecutive patients. Two radiologists independently rated the image quality and visibility of anatomical structures (right and left hepatic duct, cystic duct, gallbladder, common bile duct, and main pancreatic duct) using a four-point scale. For quantitative analysis, the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and acquisition time were evaluated. All visual scores tended to be higher for 1.5 T than 3 T images. There was a significant difference in the image quality and the depiction of the main pancreatic duct (p < 0.01). The image acquisition time was significantly shorter for 3 T than 1.5 T (199.3 ± 40.1 vs. 264.0 ± 86.5 s, p < 0.01). There was no significant difference in SNR and CNR. 3D-BTFE MRCP scans acquired at 3 T were of sufficient image quality with respect to the biliary tree. SNR and CNR were comparable on 3 and 1.5 T scans, although the acquisition time was significantly shorter with the 3 T scanner.
- 7 January 2016
- Published by Springer Nature in Abdominal Radiology
- Vol. 41 (7) , 1285-1292
Clinical application of navigator-gated three-dimensional balanced turbo-field-echo magnetic resonance cholangiopancreatography at 3 T: prospective intraindividual comparison with 1.5 T
To evaluate and compare the clinical utility of balanced turbo-field-echo (BTFE) magnetic resonance cholangiopancreatography (MRCP) sequences obtained at 3 and 1.5 T. We acquired three-dimensional (3D) BTFE MRCP scans with a navigator-gated technique at 3 T on a different day after 1.5 T in 39 consecutive patients. Two radiologists independently rated the image quality and visibility of anatomical structures (right and left hepatic duct, cystic duct, gallbladder, common bile duct, and main pancreatic duct) using a four-point scale. For quantitative analysis, the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and acquisition time were evaluated. All visual scores tended to be higher for 1.5 T than 3 T images. There was a significant difference in the image quality and the depiction of the main pancreatic duct (p < 0.01). The image acquisition time was significantly shorter for 3 T than 1.5 T (199.3 ± 40.1 vs. 264.0 ± 86.5 s, p < 0.01). There was no significant difference in SNR and CNR. 3D-BTFE MRCP scans acquired at 3 T were of sufficient image quality with respect to the biliary tree. SNR and CNR were comparable on 3 and 1.5 T scans, although the acquisition time was significantly shorter with the 3 T scanner.
- 1 January 2015
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 39 (1) , 37-43
Extracapsular Extension of Prostate Cancer
Objective The objective of this study was to assess whether adding isovoxel 3-dimensional T2-weighted imaging (volume isotropic T2-weighted acquisition [VISTA]) to multiparametric magnetic resonance imaging (mp-MRI) improves the ability to diagnose the extracapsular extension (ECE) of prostate cancer. Methods Two radiologists independently evaluated ECE on images acquired with mp-MRI only (method A) and mp-MRI plus VISTA (method B) in 50 men who had undergone prostatectomy. We also compared the signal-to-noise ratio of the tumor on T2WI and VISTA scans. Results Sensitivity, specificity, and accuracy were higher with method B. For both readers, specificity, accuracy, and the area under the receiver operating characteristic curve of method B were significantly higher than those of method A (reader 1: P = 0.028, 0.025, and 0.006; reader 2: P = 0.017, 0.0071, and 0.018). The signal-to-noise ratio was significantly higher on T2-weighted imaging than VISTA images (9.21 [SD, 2.46] vs 7.30 [SD, 1.87], P < 0.01). Conclusions The addition of VISTA to mp-MRI improves the diagnostic value for ECE significantly.
- 1 January 2015
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 39 (1) , 37-43
Extracapsular Extension of Prostate Cancer
Objective The objective of this study was to assess whether adding isovoxel 3-dimensional T2-weighted imaging (volume isotropic T2-weighted acquisition [VISTA]) to multiparametric magnetic resonance imaging (mp-MRI) improves the ability to diagnose the extracapsular extension (ECE) of prostate cancer. Methods Two radiologists independently evaluated ECE on images acquired with mp-MRI only (method A) and mp-MRI plus VISTA (method B) in 50 men who had undergone prostatectomy. We also compared the signal-to-noise ratio of the tumor on T2WI and VISTA scans. Results Sensitivity, specificity, and accuracy were higher with method B. For both readers, specificity, accuracy, and the area under the receiver operating characteristic curve of method B were significantly higher than those of method A (reader 1: P = 0.028, 0.025, and 0.006; reader 2: P = 0.017, 0.0071, and 0.018). The signal-to-noise ratio was significantly higher on T2-weighted imaging than VISTA images (9.21 [SD, 2.46] vs 7.30 [SD, 1.87], P < 0.01). Conclusions The addition of VISTA to mp-MRI improves the diagnostic value for ECE significantly.
- 17 October 2014
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 32 (12) , 685-691
Clinical utility of the normalized apparent diffusion coefficient for preoperative evaluation of the aggressiveness of prostate cancer
Normalization of the apparent diffusion coefficient (ADC) may overcome ADC variability attributable to different patient and/or technical factors. The purpose of this study was to compare the efficacy of ADC and the normalized ADC (nADC) for differentiating between prostate cancer with a Gleason score (GS) = 6 and GS > 6 and to identify an optimum reference for nADC calculations. Our study population comprised 58 patients who underwent diffusion-weighted MRI followed by radical prostatectomy. The nADC of the prostate cancer was calculated as ADC (cancer)/ADC (reference) by using the obturator internus muscle, urine in the bladder, and a 20-ml saline bottle placed on the groin as references. We performed receiver operating characteristic (ROC) analysis to identify the optimum reference for nADC calculations. To differentiate between GS = 6 and GS > 6 prostate cancer, the area under the ROC curve of the nADC obtained with a saline bottle as reference was best (0.85) and significantly better than the area under the ADC ROC curve (0.71). nADC is superior to ADC for estimating the aggressiveness of prostate cancer. It is a noninvasive technique that aids in the selection of appropriate treatments.
- 17 October 2014
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 32 (12) , 685-691
Clinical utility of the normalized apparent diffusion coefficient for preoperative evaluation of the aggressiveness of prostate cancer
Normalization of the apparent diffusion coefficient (ADC) may overcome ADC variability attributable to different patient and/or technical factors. The purpose of this study was to compare the efficacy of ADC and the normalized ADC (nADC) for differentiating between prostate cancer with a Gleason score (GS) = 6 and GS > 6 and to identify an optimum reference for nADC calculations. Our study population comprised 58 patients who underwent diffusion-weighted MRI followed by radical prostatectomy. The nADC of the prostate cancer was calculated as ADC (cancer)/ADC (reference) by using the obturator internus muscle, urine in the bladder, and a 20-ml saline bottle placed on the groin as references. We performed receiver operating characteristic (ROC) analysis to identify the optimum reference for nADC calculations. To differentiate between GS = 6 and GS > 6 prostate cancer, the area under the ROC curve of the nADC obtained with a saline bottle as reference was best (0.85) and significantly better than the area under the ADC ROC curve (0.71). nADC is superior to ADC for estimating the aggressiveness of prostate cancer. It is a noninvasive technique that aids in the selection of appropriate treatments.
- 1 October 2014
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (10) , 1740-1745
Negative predictive value of multiparametric MRI for prostate cancer detection: Outcome of 5-year follow-up in men with negative findings on initial MRI studies
- 1 October 2014
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (10) , 1740-1745
Negative predictive value of multiparametric MRI for prostate cancer detection: Outcome of 5-year follow-up in men with negative findings on initial MRI studies
- 13 January 2014
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 8 (2) , 115-123
Value of knowledge-based iterative model reconstruction in low-kV 256-slice coronary CT angiography
- 13 January 2014
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 8 (2) , 115-123
Value of knowledge-based iterative model reconstruction in low-kV 256-slice coronary CT angiography