Steven Dain
Research Subjects
Research Interests
Steven Dain has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Alexander Kiss
1 shared publicationAnthony Webster
1 shared publication- Catherine Marie Burns
University of Waterloo
1 shared publication Chris Christodoulou
Winnipeg Manitoba
1 shared publication- Dev Minotra
University of Waterloo
1 shared publication Gianluca Bertolizio
1 shared publication
Latest Publications
- Open Access
- 8 September 2017
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 6 (9) , e166
Protocol for Usability Testing and Validation of the ISO Draft International Standard 19223 for Lung Ventilators
Clinicians, such as respiratory therapists and physicians, are often required to set up pieces of medical equipment that use inconsistent terminology. Current lung ventilator terminology that is used by different manufacturers contributes to the risk of usage errors, and in turn the risk of ventilator-associated lung injuries and other conditions. Human factors and communication issues are often associated with ventilator-related sentinel events, and inconsistent ventilator terminology compounds these issues. This paper describes our proposed protocol, which will be implemented at the University of Waterloo, Canada when this project is externally funded. We propose to determine whether a standardized vocabulary improves the ease of use, safety, and utility as it relates to the usability of medical devices, compared to legacy medical devices from multiple manufacturers, which use different terms. We hypothesize that usage errors by clinicians will be lower when standardization is consistently applied by all manufacturers. The proposed study will experimentally examine the impact of standardized nomenclature on performance declines in the use of an unfamiliar ventilator product in clinically relevant scenarios. Participants will be respiratory therapy practitioners and trainees, and we propose studying approximately 60 participants. The work reported here is in the proposal phase. Once the protocol is implemented, we will report the results in a follow-up paper. The proposed study will help us better understand the effects of standardization on medical device usability. The study will also help identify any terms in the International Organization for Standardization (ISO) Draft International Standard (DIS) 19223 that may be associated with recurrent errors. Amendments to the standard will be proposed if recurrent errors are identified. This report contributes a protocol that can be used to assess the effect of standardization in any given domain that involves equipment, multiple manufacturers, inconsistent vocabulary, symbology, audio tones, or patterns in interface navigation. Second, the protocol can be used to experimentally evaluate the ISO DIS 19223 for its effectiveness, as researchers around the world may wish to conduct such tests and compare results.
- 8 September 2017
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 6 (9) , e166
Open AccessProtocol for Usability Testing and Validation of the ISO Draft International Standard 19223 for Lung Ventilators
Clinicians, such as respiratory therapists and physicians, are often required to set up pieces of medical equipment that use inconsistent terminology. Current lung ventilator terminology that is used by different manufacturers contributes to the risk of usage errors, and in turn the risk of ventilator-associated lung injuries and other conditions. Human factors and communication issues are often associated with ventilator-related sentinel events, and inconsistent ventilator terminology compounds these issues. This paper describes our proposed protocol, which will be implemented at the University of Waterloo, Canada when this project is externally funded. We propose to determine whether a standardized vocabulary improves the ease of use, safety, and utility as it relates to the usability of medical devices, compared to legacy medical devices from multiple manufacturers, which use different terms. We hypothesize that usage errors by clinicians will be lower when standardization is consistently applied by all manufacturers. The proposed study will experimentally examine the impact of standardized nomenclature on performance declines in the use of an unfamiliar ventilator product in clinically relevant scenarios. Participants will be respiratory therapy practitioners and trainees, and we propose studying approximately 60 participants. The work reported here is in the proposal phase. Once the protocol is implemented, we will report the results in a follow-up paper. The proposed study will help us better understand the effects of standardization on medical device usability. The study will also help identify any terms in the International Organization for Standardization (ISO) Draft International Standard (DIS) 19223 that may be associated with recurrent errors. Amendments to the standard will be proposed if recurrent errors are identified. This report contributes a protocol that can be used to assess the effect of standardization in any given domain that involves equipment, multiple manufacturers, inconsistent vocabulary, symbology, audio tones, or patterns in interface navigation. Second, the protocol can be used to experimentally evaluate the ISO DIS 19223 for its effectiveness, as researchers around the world may wish to conduct such tests and compare results.
- 7 October 2016
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 64 (1) , 96-97
Anesthesia scavenging in critical care areas: beware of possible hazards and questionable efficacy
- 7 October 2016
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 64 (1) , 96-97
Anesthesia scavenging in critical care areas: beware of possible hazards and questionable efficacy
- 1 July 2013
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 117 (1) , 43-46
The Effect of the Double Mask on Anesthetic Waste Gas Levels During Pediatric Mask Inductions in Dental Offices
A significant portion of office-based general anesthesia for pediatric patients is performed in dental offices and involves mask inductions with inhaled drugs. This can lead to significant pollution with waste gases. We assessed occupational exposure to anesthetic drugs during pediatric general anesthesia in dental offices and assessed the effectiveness of the "double mask." Nine freestanding dental offices had measurements of anesthetic waste gas levels taken before and immediately after implementation of a double-mask system. Levels of nitrous oxide decreased from a median of 40.0 parts per million (ppm; interquartile range [IQR] = 23.0-46.0 ppm, n = 9) to 3.0 ppm, (IQR = 2.3-4.7 ppm, n = 9, P = 0.0055) and exceeded 25 ppm in 0% of the 9 offices (upper 95% confidence limit 34%) when using the double mask. Levels of sevoflurane decreased from a median of 4.60 ppm (IQR = 3.10-7.00 ppm, n = 9) to 0 ppm (IQR = 0-0.39 ppm, n = 9, P = 0.0024) and exceeded 2 ppm in 0% of the 9 offices (upper 95% confidence limit 34%) when using the double mask. We demonstrated in our study that the double-mask system, when used with dental "high-volumes" suctions (high-volume evacuators producing approximately 12 m(3)/h) in freestanding dental offices, was sufficient to decrease the exposure to anesthetic waste gas during pediatric mask induction in at least two thirds of offices when compared with the traditional mask.
- 1 July 2013
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 117 (1) , 43-46
The Effect of the Double Mask on Anesthetic Waste Gas Levels During Pediatric Mask Inductions in Dental Offices
A significant portion of office-based general anesthesia for pediatric patients is performed in dental offices and involves mask inductions with inhaled drugs. This can lead to significant pollution with waste gases. We assessed occupational exposure to anesthetic drugs during pediatric general anesthesia in dental offices and assessed the effectiveness of the "double mask." Nine freestanding dental offices had measurements of anesthetic waste gas levels taken before and immediately after implementation of a double-mask system. Levels of nitrous oxide decreased from a median of 40.0 parts per million (ppm; interquartile range [IQR] = 23.0-46.0 ppm, n = 9) to 3.0 ppm, (IQR = 2.3-4.7 ppm, n = 9, P = 0.0055) and exceeded 25 ppm in 0% of the 9 offices (upper 95% confidence limit 34%) when using the double mask. Levels of sevoflurane decreased from a median of 4.60 ppm (IQR = 3.10-7.00 ppm, n = 9) to 0 ppm (IQR = 0-0.39 ppm, n = 9, P = 0.0024) and exceeded 2 ppm in 0% of the 9 offices (upper 95% confidence limit 34%) when using the double mask. We demonstrated in our study that the double-mask system, when used with dental "high-volumes" suctions (high-volume evacuators producing approximately 12 m(3)/h) in freestanding dental offices, was sufficient to decrease the exposure to anesthetic waste gas during pediatric mask induction in at least two thirds of offices when compared with the traditional mask.
- 1 April 2013
- Published by Wolters Kluwer Health in Survey of Anesthesiology
- Vol. 57 (2) , 81-82
Home Noninvasive Ventilation
- 1 April 2013
- Published by Wolters Kluwer Health in Survey of Anesthesiology
- Vol. 57 (2) , 81-82
Home Noninvasive Ventilation
- 1 August 2007
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 54 (8) , 613-619
Towards international standardization of the anesthesia machine
- 1 August 2007
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 54 (8) , 613-619
Towards international standardization of the anesthesia machine
- 1 June 2006
- Published by SAGE Publications in Seminars in Cardiothoracic and Vascular Anesthesia
- Vol. 10 (2) , 180-183
Management of High-Risk Perioperative Systems
The perioperative system is a complex system that requires people, materials, and processes to come together in a highly ordered and timely manner. However, when working in this high-risk system, even well-organized, knowledgeable, vigilant, and well-intentioned individuals will eventually make errors. All systems need to be evaluated on a continual basis to reduce the risk of errors, make errors more easily recognizable, and provide methods for error mitigation. A simple approach to risk management that may be applied in clinical medicine is discussed.
- 1 June 2006
- Published by SAGE Publications in Seminars in Cardiothoracic and Vascular Anesthesia
- Vol. 10 (2) , 180-183
Management of High-Risk Perioperative Systems
The perioperative system is a complex system that requires people, materials, and processes to come together in a highly ordered and timely manner. However, when working in this high-risk system, even well-organized, knowledgeable, vigilant, and well-intentioned individuals will eventually make errors. All systems need to be evaluated on a continual basis to reduce the risk of errors, make errors more easily recognizable, and provide methods for error mitigation. A simple approach to risk management that may be applied in clinical medicine is discussed.
- 1 February 2004
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 51 (2) , 185-186
Incident with a Baxter AS40A syringe pump: vigilance is warranted
- 1 February 2004
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 51 (2) , 185-186
Incident with a Baxter AS40A syringe pump: vigilance is warranted
- 1 June 2003
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 50 (6) , 625
Erratum 2
- 1 June 2003
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 50 (6) , 625
Erratum 2
- 1 March 2003
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 50 (3) , 209-214
Current equipment alarm sounds: friend or foe?
- 1 March 2003
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 50 (3) , 209-214
Current equipment alarm sounds: friend or foe?
- 1 January 2002
- Vol. 5 (3) , 254-7
Normal accidents: human error and medical equipment design.
High-risk systems, which are typical of our technologically complex era, include not just nuclear power plants but also hospitals, anesthesia systems, and the practice of medicine and perfusion. In high-risk systems, no matter how effective safety devices are, some types of accidents are inevitable because the system's complexity leads to multiple and unexpected interactions. It is important for healthcare providers to apply a risk assessment and management process to decisions involving new equipment and procedures or staffing matters in order to minimize the residual risks of latent errors, which are amenable to correction because of the large window of opportunity for their detection. This article provides an introduction to basic risk management and error theory principles and examines ways in which they can be applied to reduce and mitigate the inevitable human errors that accompany high-risk systems. The article also discusses "human factor engineering" (HFE), the process which is used to design equipment/ human interfaces in order to mitigate design errors. The HFE process involves interaction between designers and endusers to produce a series of continuous refinements that are incorporated into the final product. The article also examines common design problems encountered in the operating room that may predispose operators to commit errors resulting in harm to the patient. While recognizing that errors and accidents are unavoidable, organizations that function within a high-risk system must adopt a "safety culture" that anticipates problems and acts aggressively through an anonymous, "blameless" reporting mechanism to resolve them. We must continuously examine and improve the design of equipment and procedures, personnel, supplies and materials, and the environment in which we work to reduce error and minimize its effects. Healthcare providers must take a leading role in the day-to-day management of the "Perioperative System" and be a role model in promoting a culture of safety in their organizations.
- 1 January 2002
- Vol. 5 (3) , 254-7
Normal accidents: human error and medical equipment design.
High-risk systems, which are typical of our technologically complex era, include not just nuclear power plants but also hospitals, anesthesia systems, and the practice of medicine and perfusion. In high-risk systems, no matter how effective safety devices are, some types of accidents are inevitable because the system's complexity leads to multiple and unexpected interactions. It is important for healthcare providers to apply a risk assessment and management process to decisions involving new equipment and procedures or staffing matters in order to minimize the residual risks of latent errors, which are amenable to correction because of the large window of opportunity for their detection. This article provides an introduction to basic risk management and error theory principles and examines ways in which they can be applied to reduce and mitigate the inevitable human errors that accompany high-risk systems. The article also discusses "human factor engineering" (HFE), the process which is used to design equipment/ human interfaces in order to mitigate design errors. The HFE process involves interaction between designers and endusers to produce a series of continuous refinements that are incorporated into the final product. The article also examines common design problems encountered in the operating room that may predispose operators to commit errors resulting in harm to the patient. While recognizing that errors and accidents are unavoidable, organizations that function within a high-risk system must adopt a "safety culture" that anticipates problems and acts aggressively through an anonymous, "blameless" reporting mechanism to resolve them. We must continuously examine and improve the design of equipment and procedures, personnel, supplies and materials, and the environment in which we work to reduce error and minimize its effects. Healthcare providers must take a leading role in the day-to-day management of the "Perioperative System" and be a role model in promoting a culture of safety in their organizations.