Atsuo Tomidokoro
Research Subjects
Atsuo Tomidokoro has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
Makoto Araie
Department of Ophthalmology, University of Tokyo, Graduate School of Medicine, Tokyo, Japan
13 shared publications- Makoto Araie
Department of Ophthalmology, University of Tokyo Graduate School of Medicine
8 shared publications Aiko Iwase
Department of Ophthalmology, Tajimi Iwase Eye Clinic, Gifu, Tajimi, Japan
7 shared publications- Aiko Iwase
Tajimi Iwase Eye Clinic, Tajimi, Japan
5 shared publications Shoichi Sawaguchi
Department of Ophthalmology Faculty of Medicine University of Ryukyu Naha Okinawa Japan
4 shared publicationsGoji Tomita
3 shared publications
Latest Publications
- Open Access
- 22 June 2020
- Published by Wiley in Acta Ophthalmologica
- Vol. 99 (1) , E86-E95
Evaluation of anterior chamber angle by van Herick grading and ultrasound biomicroscopy in light and dark conditions for finding appositional angle closure and plateau iris configuration
Purpose: To evaluate association of the van Herick (VH) grades with the ultrasound biomicroscopic (UBM) parameters, appositional irido‐trabecular contact (A‐ITC) and plateau iris (PI) in a randomly sampled population.Methods: A 10% random sample of all residents aged 40 or older of the Kumejima study underwent UBM under dark and light conditions in the four quadrants of right eyes.Results: Of 301 right eyes with eligible UBM images, 101 (33.6%) and 200 (66.4%) were classified as VH ≤ 2 and VH ≥ 3, respectively. The UBM parameters on angle width and ciliary body configuration were significantly different between VH ≤ 2 and VH ≥ 3 eyes (p < 0.001). A‐ITC was found in at least one quadrant in 54.5% and 75.2% of VH ≤ 2 eyes under light and dark conditions, respectively; and 20.5% and 45.5% of VH ≥ 3 eyes. When ‘VH ≤ 2’ was used to screen eyes with A‐ITC in three or more quadrants, the sensitivity and specificity were 74.1% and 75.3%, respectively. A‐ITC was significantly associated with shallower anterior chamber (p = 0.018) and higher intraocular pressure (p = 0.044) in VH ≥ 3 eyes. Plateau iris (PI) was found in 15.8% and 6.0% of VH ≤ 2 and VH ≥ 3 eyes, respectively. Plateau iris (PI) was significantly associated with the UBM parameters on angle width and ciliary body configuration. When ‘VH ≤ 2’ was used to screen eyes with PI, the sensitivity and specificity were 57.1% and 68.9%, respectively.Conclusions: The VH grade of ≤2 and ≥3 showed significant association with UBM angle width and ciliary body configuration parameters. The VH ≤ 2 criterion should be useful for screening of A‐ITC and PI.
- 22 June 2020
- Published by Wiley in Acta Ophthalmologica
- Vol. 99 (1) , E86-E95
Open AccessEvaluation of anterior chamber angle by van Herick grading and ultrasound biomicroscopy in light and dark conditions for finding appositional angle closure and plateau iris configuration
Purpose: To evaluate association of the van Herick (VH) grades with the ultrasound biomicroscopic (UBM) parameters, appositional irido‐trabecular contact (A‐ITC) and plateau iris (PI) in a randomly sampled population.Methods: A 10% random sample of all residents aged 40 or older of the Kumejima study underwent UBM under dark and light conditions in the four quadrants of right eyes.Results: Of 301 right eyes with eligible UBM images, 101 (33.6%) and 200 (66.4%) were classified as VH ≤ 2 and VH ≥ 3, respectively. The UBM parameters on angle width and ciliary body configuration were significantly different between VH ≤ 2 and VH ≥ 3 eyes (p < 0.001). A‐ITC was found in at least one quadrant in 54.5% and 75.2% of VH ≤ 2 eyes under light and dark conditions, respectively; and 20.5% and 45.5% of VH ≥ 3 eyes. When ‘VH ≤ 2’ was used to screen eyes with A‐ITC in three or more quadrants, the sensitivity and specificity were 74.1% and 75.3%, respectively. A‐ITC was significantly associated with shallower anterior chamber (p = 0.018) and higher intraocular pressure (p = 0.044) in VH ≥ 3 eyes. Plateau iris (PI) was found in 15.8% and 6.0% of VH ≤ 2 and VH ≥ 3 eyes, respectively. Plateau iris (PI) was significantly associated with the UBM parameters on angle width and ciliary body configuration. When ‘VH ≤ 2’ was used to screen eyes with PI, the sensitivity and specificity were 57.1% and 68.9%, respectively.Conclusions: The VH grade of ≤2 and ≥3 showed significant association with UBM angle width and ciliary body configuration parameters. The VH ≤ 2 criterion should be useful for screening of A‐ITC and PI.
- 12 March 2020
- Published by Wiley in Acta Ophthalmologica
- Vol. 98 (7) , E888-E894
Pseudoexfoliation syndrome and relating factors in a rural Japanese population: the Kumejima Study
Purpose: To report the prevalence of pseudoexfoliation (PEX) syndrome and glaucoma associated with PEX (PEX‐G) and their relating factors of them in a south‐western island of Japan.Methods: A population‐based survey of all residents aged ≥ 40 years was conducted in Kumejima, Okinawa, Japan, and 3762 subjects (participation rate, 81.2%) underwent detailed ophthalmic examinations. Presence of PEX material on the lens capsule, iris surface and/or pupillary margin was determined by slit‐lamp biomicroscopy. Glaucoma was diagnosed according to the criteria of the International Society of Geographical and Epidemiological Ophthalmology.Results: In subjects aged ≥ 40 years, prevalence rates of PEX syndrome, PEX without glaucoma and PEX‐G in at least one eye were 1.5% (95% confidence interval [CI]: 1.0–1.9%), 1.3% (95% CI: 0.9–1.7%) and 0.1% (95% CI: 0.0–0.2%), respectively, excluding eyes after cataract surgery; and 2.8% (95% CI: 2.3–3.3%), 2.2% (95% CI: 1.8–2.6 %) and 0.4% (95% CI: 0.2–0.6%), respectively, including eyes after cataract surgery. Cataract surgery had been performed in 61% of subjects with PEX in at least one eye; presence of PEX showed no significant effects on the intraocular pressure (IOP). A multivariate analysis showed that PEX was associated with older age (p < 0.0001, odds ratio: 1.10 [95% CI: 1.07–1.13]) and working outdoors (p = 0.0395, odds ratio: 2.18 [95% CI: 0.99–4.82]).Conclusions: The prevalence rates of PEX syndrome and PEX‐G in a south‐western island of Japan were reported. PEX showed no significant effect on IOP, and age and working outdoors were significantly related with PEX.
- 12 March 2020
- Published by Wiley in Acta Ophthalmologica
- Vol. 98 (7) , E888-E894
Pseudoexfoliation syndrome and relating factors in a rural Japanese population: the Kumejima Study
Purpose: To report the prevalence of pseudoexfoliation (PEX) syndrome and glaucoma associated with PEX (PEX‐G) and their relating factors of them in a south‐western island of Japan.Methods: A population‐based survey of all residents aged ≥ 40 years was conducted in Kumejima, Okinawa, Japan, and 3762 subjects (participation rate, 81.2%) underwent detailed ophthalmic examinations. Presence of PEX material on the lens capsule, iris surface and/or pupillary margin was determined by slit‐lamp biomicroscopy. Glaucoma was diagnosed according to the criteria of the International Society of Geographical and Epidemiological Ophthalmology.Results: In subjects aged ≥ 40 years, prevalence rates of PEX syndrome, PEX without glaucoma and PEX‐G in at least one eye were 1.5% (95% confidence interval [CI]: 1.0–1.9%), 1.3% (95% CI: 0.9–1.7%) and 0.1% (95% CI: 0.0–0.2%), respectively, excluding eyes after cataract surgery; and 2.8% (95% CI: 2.3–3.3%), 2.2% (95% CI: 1.8–2.6 %) and 0.4% (95% CI: 0.2–0.6%), respectively, including eyes after cataract surgery. Cataract surgery had been performed in 61% of subjects with PEX in at least one eye; presence of PEX showed no significant effects on the intraocular pressure (IOP). A multivariate analysis showed that PEX was associated with older age (p < 0.0001, odds ratio: 1.10 [95% CI: 1.07–1.13]) and working outdoors (p = 0.0395, odds ratio: 2.18 [95% CI: 0.99–4.82]).Conclusions: The prevalence rates of PEX syndrome and PEX‐G in a south‐western island of Japan were reported. PEX showed no significant effect on IOP, and age and working outdoors were significantly related with PEX.
- Open Access
- 15 November 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (11) , e0207180
Refractive errors in an elderly rural Japanese population: The Kumejima study
The prevalence of refractive errors, which closely relates to visual function difficulties, several ocular disorders, and decreased quality of life, varies among countries and populations. One of the highest prevalence of myopia (spherical equivalent [SE] < -0.5 diopters [D], 41.8%) has been reported in an urban city (Tajimi) in central Japan. Here, we assess refractive conditions in a rural southwestern island (Kumejima) of Japan, where a high prevalence of glaucoma, especially angle-closure glaucoma, has been found. In Kumejima, the prevalence of myopia (SE < -0.5 D), high myopia (SE < -5 D), hyperopia (SE > +0.5 D), refractive astigmatism (cylinder > 0.5 D), and anisometropia (difference in SE between eyes > 1.0 D) were 29.5%, 1.9%, 34.1%, 38.8%, and 15.5%, respectively. Myopia decreased with age up to 70 years old but increased slightly thereafter, whereas hyperopia increased up to 70 years old and was unchanged thereafter. The prevalence of astigmatism and anisometropia was higher in older subjects. The prevalence of myopia and high myopia was higher than most of white, Hispanic, and other Asian populations, while was considerably lower than in the urban city of Japan. The high prevalence of hyperopia should be associated with high prevalence of angle closure glaucoma in this island.
- 15 November 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (11) , e0207180
Open AccessRefractive errors in an elderly rural Japanese population: The Kumejima study
The prevalence of refractive errors, which closely relates to visual function difficulties, several ocular disorders, and decreased quality of life, varies among countries and populations. One of the highest prevalence of myopia (spherical equivalent [SE] < -0.5 diopters [D], 41.8%) has been reported in an urban city (Tajimi) in central Japan. Here, we assess refractive conditions in a rural southwestern island (Kumejima) of Japan, where a high prevalence of glaucoma, especially angle-closure glaucoma, has been found. In Kumejima, the prevalence of myopia (SE < -0.5 D), high myopia (SE < -5 D), hyperopia (SE > +0.5 D), refractive astigmatism (cylinder > 0.5 D), and anisometropia (difference in SE between eyes > 1.0 D) were 29.5%, 1.9%, 34.1%, 38.8%, and 15.5%, respectively. Myopia decreased with age up to 70 years old but increased slightly thereafter, whereas hyperopia increased up to 70 years old and was unchanged thereafter. The prevalence of astigmatism and anisometropia was higher in older subjects. The prevalence of myopia and high myopia was higher than most of white, Hispanic, and other Asian populations, while was considerably lower than in the urban city of Japan. The high prevalence of hyperopia should be associated with high prevalence of angle closure glaucoma in this island.
- 25 March 2018
- Published by Wiley in Acta Ophthalmologica
- Vol. 96 (6) , E701-E706
Beta‐peripapillary atrophy of the optic disc and its determinants in Japanese eyes: a population‐based study
Purposes: To assess β‐zone of peripapillary atrophy (β‐PPA) and its relationship between systemic and ocular factors, especially glaucoma, in a Japanese population.Methods: Fundus photographs obtained from 2129 normal, 84 primary open‐angle glaucoma (POAG) and 10 primary angle closure glaucoma subjects from 3021 participants aged 40 years or older in the Tajimi Study were analysed planimetrically. If both eyes of a subject met inclusion criteria, one eye was randomly chosen.Results: The presence rates of β‐PPA were 54.7 and 77.4% (p < 0.001) and β‐PPA area averaged 0.67 and 1.06 mm2 (p < 0.001), in normal and POAG eyes, respectively. Myopia was closely related to disc ovality and β‐PPA. In normal eyes, logistic analysis showed that the presence of β‐PPA was correlated with older age, female gender, myopic refraction, thicker central corneal thickness (CCT), greater disc ovality and disc centre to fovea (disc‐fovea) distance and lower intraocular pressure (IOP) (p = 0.039 ~ β‐PPA area was correlated with older age, myopic refraction, greater disc area and ovality, disc‐fovea distance and lower IOP (p = 0.004 ~ β‐PPA in normal eyes were correlated with older age, greater disc ovality and disc‐fovea distance and lower IOP. Further, its presence was associated with female gender, thicker CCT and its size with greater disc area. β‐zone of peripapillary atrophy (β‐PPA) was also associated with POAG. These results provide reference data of the β‐PPA in a Japanese population and possibly indicate clinical importance of β‐PPA in glaucoma clinic.
- 25 March 2018
- Published by Wiley in Acta Ophthalmologica
- Vol. 96 (6) , E701-E706
Beta‐peripapillary atrophy of the optic disc and its determinants in Japanese eyes: a population‐based study
Purposes: To assess β‐zone of peripapillary atrophy (β‐PPA) and its relationship between systemic and ocular factors, especially glaucoma, in a Japanese population.Methods: Fundus photographs obtained from 2129 normal, 84 primary open‐angle glaucoma (POAG) and 10 primary angle closure glaucoma subjects from 3021 participants aged 40 years or older in the Tajimi Study were analysed planimetrically. If both eyes of a subject met inclusion criteria, one eye was randomly chosen.Results: The presence rates of β‐PPA were 54.7 and 77.4% (p < 0.001) and β‐PPA area averaged 0.67 and 1.06 mm2 (p < 0.001), in normal and POAG eyes, respectively. Myopia was closely related to disc ovality and β‐PPA. In normal eyes, logistic analysis showed that the presence of β‐PPA was correlated with older age, female gender, myopic refraction, thicker central corneal thickness (CCT), greater disc ovality and disc centre to fovea (disc‐fovea) distance and lower intraocular pressure (IOP) (p = 0.039 ~ β‐PPA area was correlated with older age, myopic refraction, greater disc area and ovality, disc‐fovea distance and lower IOP (p = 0.004 ~ β‐PPA in normal eyes were correlated with older age, greater disc ovality and disc‐fovea distance and lower IOP. Further, its presence was associated with female gender, thicker CCT and its size with greater disc area. β‐zone of peripapillary atrophy (β‐PPA) was also associated with POAG. These results provide reference data of the β‐PPA in a Japanese population and possibly indicate clinical importance of β‐PPA in glaucoma clinic.
- 1 January 2016
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 25 (1) , e12-e18
Reproducibility of Circumpapillary Retinal Nerve Fiber Layer Thickness Measurements Evaluated by Circle and Annulus Area With and Without Correction for Ocular Rotation
To compare the reproducibility of annulus area measurements of the circumpapillary retinal nerve fiber layer thickness (cpRNFLTannulus) using spectral-domain optical coherence tomography (SD-OCT) with that of conventional cpRNFLT (cpRNFLTring) measurements and evaluate the effect of correction of ocular rotation on the reproducibility. Peripapillary SD-OCT raster scans were performed on 2 different days in 48 normal subjects and 59 patients with glaucoma using the Topcon OCT-1000. In the raster scan dataset, the cpRNFLTring and cpRNFLTannulus were averaged along a circle (3.4-mm diameter) and in an annulus area (diameters from 2.8 to 4.0 mm) centered on the barycenter of the disc. The measurement reproducibility, effects of ocular rotational correction, and factors affecting the reproducibility were studied. The intervisit reproducibility values, expressed as the coefficients of variation, for the cpRNFLTannulus, were significantly smaller than those for the cpRNFLTring measurements in sectors 30 degrees wide in glaucomatous eyes (P=0.006) and in sectors 10 degrees wide in normal and glaucomatous eyes (P<0.001). The ocular rotational angles averaged 7.1 and 7.2 degrees with intervisit differences of 1.4 and 1.8 degrees, respectively, in normal and glaucomatous eyes. Correction for the ocular rotation had little effect on the reproducibility. The mean deviation and cpRNFLT were correlated negatively with the coefficient of variation (β=-0.93 to -0.83; P=0.027 to 0.028). The cpRNFLTannulus measurement yielded better reproducibility than the cpRNFLTring measurement, and multiple linear regression analysis showed that the more advanced the glaucomatous damage, the worse the intervisit reproducibility.
- 1 January 2016
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 25 (1) , e12-e18
Reproducibility of Circumpapillary Retinal Nerve Fiber Layer Thickness Measurements Evaluated by Circle and Annulus Area With and Without Correction for Ocular Rotation
To compare the reproducibility of annulus area measurements of the circumpapillary retinal nerve fiber layer thickness (cpRNFLTannulus) using spectral-domain optical coherence tomography (SD-OCT) with that of conventional cpRNFLT (cpRNFLTring) measurements and evaluate the effect of correction of ocular rotation on the reproducibility. Peripapillary SD-OCT raster scans were performed on 2 different days in 48 normal subjects and 59 patients with glaucoma using the Topcon OCT-1000. In the raster scan dataset, the cpRNFLTring and cpRNFLTannulus were averaged along a circle (3.4-mm diameter) and in an annulus area (diameters from 2.8 to 4.0 mm) centered on the barycenter of the disc. The measurement reproducibility, effects of ocular rotational correction, and factors affecting the reproducibility were studied. The intervisit reproducibility values, expressed as the coefficients of variation, for the cpRNFLTannulus, were significantly smaller than those for the cpRNFLTring measurements in sectors 30 degrees wide in glaucomatous eyes (P=0.006) and in sectors 10 degrees wide in normal and glaucomatous eyes (P<0.001). The ocular rotational angles averaged 7.1 and 7.2 degrees with intervisit differences of 1.4 and 1.8 degrees, respectively, in normal and glaucomatous eyes. Correction for the ocular rotation had little effect on the reproducibility. The mean deviation and cpRNFLT were correlated negatively with the coefficient of variation (β=-0.93 to -0.83; P=0.027 to 0.028). The cpRNFLTannulus measurement yielded better reproducibility than the cpRNFLTring measurement, and multiple linear regression analysis showed that the more advanced the glaucomatous damage, the worse the intervisit reproducibility.
- 1 January 2014
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 23 (4) , 202-205
Factors Related to Future Peripheral Anterior Synechiae Formation on Ultrasound Biomicroscopy
Purpose: To study factors associated with future peripheral anterior synechiae (PAS) formation on ultrasound biomicroscopy (UBM) in eyes with a shallow peripheral anterior chamber. Patients and Methods: Fifteen subjects with a shallow peripheral anterior chamber but no PAS in both eyes, in 2001, that had no medical or surgical intervention until 2008 were included in this study. The same examiners performed gonioscopy and UBM at the 3, 6, 9, and 12 o’clock limbal positions under dark and light conditions in 2001 and 2008. A masked examiner performed a quantitative evaluation of the angle configurations in the UBM images. The presence or absence of PAS was determined by compression gonioscopy. The UBM parameters and the number of appositional closures per eye were compared between PAS-positive eyes and PAS-negative eyes. Results: One eye from 15 subjects were randomly selected and included in the analyses. The gonioscopic gradings and UBM parameters did not change significantly (P>0.1) between 2001 and 2008. Seven (47%; 95% confidence interval, 25-70) of 15 eyes developed PAS. In 2001, under dark conditions, the appositional angle closure in 3 to 4 quadrants was found more often (P=0.026) in 7 eyes where PAS developed during the following 7 years than in other 8 eyes. Conclusions: In eyes with a shallow peripheral anterior chamber but no PAS, PAS developed in 47% of eyes followed without intervention for 7 years. PAS was significantly more likely to develop in eyes with the appositional angle closure found in 3 to 4 quadrants under dark conditions.
- 1 January 2014
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 23 (4) , 202-205
Factors Related to Future Peripheral Anterior Synechiae Formation on Ultrasound Biomicroscopy
Purpose: To study factors associated with future peripheral anterior synechiae (PAS) formation on ultrasound biomicroscopy (UBM) in eyes with a shallow peripheral anterior chamber. Patients and Methods: Fifteen subjects with a shallow peripheral anterior chamber but no PAS in both eyes, in 2001, that had no medical or surgical intervention until 2008 were included in this study. The same examiners performed gonioscopy and UBM at the 3, 6, 9, and 12 o’clock limbal positions under dark and light conditions in 2001 and 2008. A masked examiner performed a quantitative evaluation of the angle configurations in the UBM images. The presence or absence of PAS was determined by compression gonioscopy. The UBM parameters and the number of appositional closures per eye were compared between PAS-positive eyes and PAS-negative eyes. Results: One eye from 15 subjects were randomly selected and included in the analyses. The gonioscopic gradings and UBM parameters did not change significantly (P>0.1) between 2001 and 2008. Seven (47%; 95% confidence interval, 25-70) of 15 eyes developed PAS. In 2001, under dark conditions, the appositional angle closure in 3 to 4 quadrants was found more often (P=0.026) in 7 eyes where PAS developed during the following 7 years than in other 8 eyes. Conclusions: In eyes with a shallow peripheral anterior chamber but no PAS, PAS developed in 47% of eyes followed without intervention for 7 years. PAS was significantly more likely to develop in eyes with the appositional angle closure found in 3 to 4 quadrants under dark conditions.
- 1 March 2012
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 53 (3) , 1332-1340
Planimetrically Determined Vertical Cup/Disc and Rim Width/Disc Diameter Ratios and Related Factors
Purpose.: To evaluate the distribution and factors related to planimetrically determined vertical cup/disc (v-C/D) and rim width/disc diameter (Rw/Dd) ratios of the optic discs in a population-based study of Japanese subjects without glaucoma. Methods.: Of 4632 eligible residents 40 years of age and older, 3762 residents underwent a detailed ocular examination including sequential optic disc stereo photography with a digital nonmydriatic fundus camera. The photographs were assessed by computer-assisted planimetry. The authors studied both eyes of 2311 nonglaucomatous subjects and only one right (left) eye of 196 (175) subjects for whom disc stereo photographs were of acceptable quality. Results.: The median (2.5th and/or 97.5th percentile) disc area, v-C/D, its asymmetry, and the superior- and inferior-minimal Rw/Dd ratios were 2.56 (1.68, 3.71) mm2, 0.56 (0.70), 0.05 (0.14), 0.18 (0.10), and 0.21 (0.12), respectively. Multiple regression analysis showed that males had larger discs and superior Rw/Dd and smaller inferior Rw/Dd ratios. Increased age was correlated with increased v-C/D and decreased superior and inferior Rw/Dd ratios. Higher intraocular pressure (IOP) and thinner central corneal thickness (CCT) were correlated with higher v-C/D and smaller inferior rim/disc ratios, and lower diastolic ocular perfusion pressure (OPP) with greater v-C/D and smaller superior Rw/Dd ratios. Conclusions.: In nonglaucomatous eyes, increased v-C/D and decreased superior and inferior Rw/Dd ratios were significantly correlated not only with increased age and disc size but also with higher IOP, lower diastolic OPP, and thinner CCT, suggesting that these simple disc parameters also represent vulnerability to glaucoma insults in nonglaucomatous eyes.
- 1 March 2012
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 53 (3) , 1332-1340
Planimetrically Determined Vertical Cup/Disc and Rim Width/Disc Diameter Ratios and Related Factors
Purpose.: To evaluate the distribution and factors related to planimetrically determined vertical cup/disc (v-C/D) and rim width/disc diameter (Rw/Dd) ratios of the optic discs in a population-based study of Japanese subjects without glaucoma. Methods.: Of 4632 eligible residents 40 years of age and older, 3762 residents underwent a detailed ocular examination including sequential optic disc stereo photography with a digital nonmydriatic fundus camera. The photographs were assessed by computer-assisted planimetry. The authors studied both eyes of 2311 nonglaucomatous subjects and only one right (left) eye of 196 (175) subjects for whom disc stereo photographs were of acceptable quality. Results.: The median (2.5th and/or 97.5th percentile) disc area, v-C/D, its asymmetry, and the superior- and inferior-minimal Rw/Dd ratios were 2.56 (1.68, 3.71) mm2, 0.56 (0.70), 0.05 (0.14), 0.18 (0.10), and 0.21 (0.12), respectively. Multiple regression analysis showed that males had larger discs and superior Rw/Dd and smaller inferior Rw/Dd ratios. Increased age was correlated with increased v-C/D and decreased superior and inferior Rw/Dd ratios. Higher intraocular pressure (IOP) and thinner central corneal thickness (CCT) were correlated with higher v-C/D and smaller inferior rim/disc ratios, and lower diastolic ocular perfusion pressure (OPP) with greater v-C/D and smaller superior Rw/Dd ratios. Conclusions.: In nonglaucomatous eyes, increased v-C/D and decreased superior and inferior Rw/Dd ratios were significantly correlated not only with increased age and disc size but also with higher IOP, lower diastolic OPP, and thinner CCT, suggesting that these simple disc parameters also represent vulnerability to glaucoma insults in nonglaucomatous eyes.
- 1 August 2011
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 52 (9) , 6934-6939
Identification of Schlemm's Canal and Its Surrounding Tissues by Anterior Segment Fourier Domain Optical Coherence Tomography
Purpose.: To identify Schlemm's canal (SC) and trabecular meshwork (TM) by anterior segment Fourier-domain optical coherence tomography (AS-FD-OCT) with histologic confirmation in enucleated human eyes and to quantitatively evaluate SC and TM in living human eyes. Methods.: In enucleated human eyes, the imaging of the anterior chamber angle by AS-FD-OCT was performed before and after surgical expansion of SC with an injection of a viscoelastic material, followed by histologic examination. In 60 living human eyes, the agreement of identification of SC between examiners was evaluated with the Cohen's κ values, and the lengths of SC and TM and the area of TM were measured on temporal and nasal sections of the AS-FD-OCT images. Results.: In enucleated human eyes, SC was observed to be a thin, linear, lucent space in the AS-FD-OCT image obtained with the high-definition raster scan protocol, but not in those obtained with the bi-angle radial scan protocol. This space was enlarged after the SC expansion. In the histologic study, the SC was confirmed to be in the same position as in the AS-FD-OCT images. The κ values of observable SC in living human subjects were 0.92 or higher. The axial length of the SC averaged 347.2 ± 42.3 μm, TM length 466.9 ± 60.7 μm, and TM area 0.0671 ± 0.0058 mm2. These measurements showed sufficient repeatability and reproducibility. Conclusions.: Using the high-definition images of the AS-FD-OCT, SC and its surrounding tissues were successfully observed in most of the living eyes and were quantitatively evaluated in a noninvasive manner.
- 1 August 2011
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 52 (9) , 6934-6939
Identification of Schlemm's Canal and Its Surrounding Tissues by Anterior Segment Fourier Domain Optical Coherence Tomography
Purpose.: To identify Schlemm's canal (SC) and trabecular meshwork (TM) by anterior segment Fourier-domain optical coherence tomography (AS-FD-OCT) with histologic confirmation in enucleated human eyes and to quantitatively evaluate SC and TM in living human eyes. Methods.: In enucleated human eyes, the imaging of the anterior chamber angle by AS-FD-OCT was performed before and after surgical expansion of SC with an injection of a viscoelastic material, followed by histologic examination. In 60 living human eyes, the agreement of identification of SC between examiners was evaluated with the Cohen's κ values, and the lengths of SC and TM and the area of TM were measured on temporal and nasal sections of the AS-FD-OCT images. Results.: In enucleated human eyes, SC was observed to be a thin, linear, lucent space in the AS-FD-OCT image obtained with the high-definition raster scan protocol, but not in those obtained with the bi-angle radial scan protocol. This space was enlarged after the SC expansion. In the histologic study, the SC was confirmed to be in the same position as in the AS-FD-OCT images. The κ values of observable SC in living human subjects were 0.92 or higher. The axial length of the SC averaged 347.2 ± 42.3 μm, TM length 466.9 ± 60.7 μm, and TM area 0.0671 ± 0.0058 mm2. These measurements showed sufficient repeatability and reproducibility. Conclusions.: Using the high-definition images of the AS-FD-OCT, SC and its surrounding tissues were successfully observed in most of the living eyes and were quantitatively evaluated in a noninvasive manner.
- 1 March 2011
- Vol. 115 (3) , 276
[Imagings of glaucoma: characteristics of ocular configurations and automated diagnosis].
Glaucoma is characterized by the coexistence of structural changes in the fundus and the corresponding functional abnormalities. The advances in imaging devices that reveal structural changes in glaucoma should facilitate reliable diagnosis of early or preperimetric glaucoma and a proper evaluation of glaucoma progression. Moreover, the increase in our knowledge of structural changes in glaucoma will provide a better platform for investigating up to now unknown glaucoma etiologies. In this review, we summarize a series of our clinical investigations of glaucoma imaging technologies. The diagnostic performance of Heidelberg Retina Tomograph (HRT) II and the characteristics of the HRT II parameters in high myopia were studied with population-based data to provide data for nerve head configuration; the correlation of parameters determined by planimetry of optic disc stereophotography with the results of the HRT II was evaluated; optic disc parameters were determined based on spectral-domain optical coherence tomography (SD-OCT); and optic disc configurations were evaluated in eyes with peripapillary atrophy and eyes with superior segmental optic nerve hypoplasia. Peripapillary retinal nerve fiber layer (RNFL) thickness was determined with SD-OCT in normal Japanese eyes; and the diagnostic performance of RNFL thickness was studied. The characteristics of each layer, including retinal nerve fiber layer, ganglion cell layer, and each complex layer in the macular area, and their correlation with the stages of glaucoma were evaluated. Finally, imaging of the anterior chamber angle using ultrasound biomicroscopy (UBM) were studied about the distribution of the UBM parameters in a Japanese population and the factors relating to the presence of peripheral anterior synechia in narrow angle eyes.
- 1 March 2011
- Vol. 115 (3) , 276
[Imagings of glaucoma: characteristics of ocular configurations and automated diagnosis].
Glaucoma is characterized by the coexistence of structural changes in the fundus and the corresponding functional abnormalities. The advances in imaging devices that reveal structural changes in glaucoma should facilitate reliable diagnosis of early or preperimetric glaucoma and a proper evaluation of glaucoma progression. Moreover, the increase in our knowledge of structural changes in glaucoma will provide a better platform for investigating up to now unknown glaucoma etiologies. In this review, we summarize a series of our clinical investigations of glaucoma imaging technologies. The diagnostic performance of Heidelberg Retina Tomograph (HRT) II and the characteristics of the HRT II parameters in high myopia were studied with population-based data to provide data for nerve head configuration; the correlation of parameters determined by planimetry of optic disc stereophotography with the results of the HRT II was evaluated; optic disc parameters were determined based on spectral-domain optical coherence tomography (SD-OCT); and optic disc configurations were evaluated in eyes with peripapillary atrophy and eyes with superior segmental optic nerve hypoplasia. Peripapillary retinal nerve fiber layer (RNFL) thickness was determined with SD-OCT in normal Japanese eyes; and the diagnostic performance of RNFL thickness was studied. The characteristics of each layer, including retinal nerve fiber layer, ganglion cell layer, and each complex layer in the macular area, and their correlation with the stages of glaucoma were evaluated. Finally, imaging of the anterior chamber angle using ultrasound biomicroscopy (UBM) were studied about the distribution of the UBM parameters in a Japanese population and the factors relating to the presence of peripheral anterior synechia in narrow angle eyes.