Yaping Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yaping Wu has a total of 169 co-authors. Here are the top co-authors by number of shared publications:
- Meiyun Wang
Department of Radiology, Zhengzhou University People’s Hospital & Henan Provincial People’s Hospital, Zhengzhou, China
23 shared publications - Dong Liang
Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences
11 shared publications - Hairong Zheng
Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
10 shared publications - Zhanli Hu
Research Center for Medical AI, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
8 shared publications - Yusong Lin
Zhengzhou University
7 shared publications Meiyun Wang
Department of Medical Imaging, Henan Provincial Peoples Hospital and Peoples Hospital of Zhengzhou University, Zhengzhou, China
6 shared publications
Latest Publications
- 1 September 2026
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 320 (3)
Helical 3D DSA for Whole-Head-and-Neck Vascular Imaging: Technical Development and First-in-Human Application
A helical scanning trajectory extended the longitudinal coverage of three-dimensional (3D) digital subtraction angiography, enabling 3D angiography from the aortic arch to the cranial vertex using a robotic C-arm system.
- 1 September 2026
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 320 (3)
Helical 3D DSA for Whole-Head-and-Neck Vascular Imaging: Technical Development and First-in-Human Application
A helical scanning trajectory extended the longitudinal coverage of three-dimensional (3D) digital subtraction angiography, enabling 3D angiography from the aortic arch to the cranial vertex using a robotic C-arm system.
- 3 April 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 112, 104063
A hierarchical prompt and prototype learning framework for brain disorder classification
- 3 April 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 112, 104063
A hierarchical prompt and prototype learning framework for brain disorder classification
- 9 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. PP (21682194) , 1-11
DGRTA: Cross-Modality Unsupervised Domain Adaptation for Intracranial Vessel Segmentation via Dual-Gated Refinement and Topology-Aware Weighting
TOF-MRA intracranial vessel segmentation is critical in clinical practice but challenged by limited annotations and significant cross-modality domain shifts. To address these issues, this study proposes DGRTA, an unsupervised domain adaptation framework that integrates cross-modality pseudo-label generation, a dual-gated pseudo-label refinement strategy (DGR), and a topology aware weighting mechanism (TA). Initially, rigid and non-rigid registration are used to transfer CTA predictions to TOF-MRA to generate initial pseudo-labels. DGR then refines these labels using prediction probabilities and image intensity, enhancing sensitivity and specificity, while TA leverages Persistence Diagrams (PD) to quantify topological discrepancies and dynamically adjust loss weights. Experiments on 185 paired CTA/TOF-MRA cases demonstrated that DGRTA consistently improved performance across four backbone architectures (UNet, Attention UNet, UNETR, Swin UNETR). The Attention UNet DGRTA achieved the best results, with a Dice of 0.810, clDice of 0.800, and an AHD of 0.353 mm on the validation set, significantly outperforming the baseline model (p < 0.001). DGRTA offers a feasible solution that reduces reliance on extensive manual annotations, underscoring the potential of unsupervised cross-modality segmentation in various vascular imaging applications.
- 9 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. PP (21682194) , 1-11
DGRTA: Cross-Modality Unsupervised Domain Adaptation for Intracranial Vessel Segmentation via Dual-Gated Refinement and Topology-Aware Weighting
TOF-MRA intracranial vessel segmentation is critical in clinical practice but challenged by limited annotations and significant cross-modality domain shifts. To address these issues, this study proposes DGRTA, an unsupervised domain adaptation framework that integrates cross-modality pseudo-label generation, a dual-gated pseudo-label refinement strategy (DGR), and a topology aware weighting mechanism (TA). Initially, rigid and non-rigid registration are used to transfer CTA predictions to TOF-MRA to generate initial pseudo-labels. DGR then refines these labels using prediction probabilities and image intensity, enhancing sensitivity and specificity, while TA leverages Persistence Diagrams (PD) to quantify topological discrepancies and dynamically adjust loss weights. Experiments on 185 paired CTA/TOF-MRA cases demonstrated that DGRTA consistently improved performance across four backbone architectures (UNet, Attention UNet, UNETR, Swin UNETR). The Attention UNet DGRTA achieved the best results, with a Dice of 0.810, clDice of 0.800, and an AHD of 0.353 mm on the validation set, significantly outperforming the baseline model (p < 0.001). DGRTA offers a feasible solution that reduces reliance on extensive manual annotations, underscoring the potential of unsupervised cross-modality segmentation in various vascular imaging applications.
- 2 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (1) , 16-25
Diffusion-Based Model for Parametric K i Generation From Total-Body Dynamic PET of Short-Duration Scan
Dynamic positron emission tomography (PET) parametric imaging typically requires a 60-minute acquisition period, causing patient discomfort and reducing clinical efficiency. This study explores the feasibility of generating parametric Ki images from 10-minute dynamic PET images acquired in the early or late scanning phases employing a multi-channel feature fusion cold sampling (MCFFCoS) framework. PET data from 103 patients are acquired using the uEXPLORER total-body PET/CT scanner during 60-minute scans. This study conducts deep learning experiments, taking early-phase or late-phase PET images as input, respectively. The generated Ki images are evaluated by visual quality and quantitative metrics, including root mean squared error (RMSE), structural similarity index (SSIM), and peak signal-to-noise ratio (PSNR). Volumes of interest (VOIs) analysis is performed using linear regression and Bland-Altman plots. In the quantitative evaluation of total-body data, the parametric Ki images generated from late-phase PET data generally outperform those derived from early-phase data. The analysis of VOIs indicates that the appropriate scanning protocol for PET parametric imaging may vary for different body regions. The deep learning approach is able to generate high-quality parametric Ki images from 10-minute dynamic PET scans, bypassing the requirements of long acquisition time for the estimation of blood input function in kinetic modeling.
- 2 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (1) , 16-25
Diffusion-Based Model for Parametric K i Generation From Total-Body Dynamic PET of Short-Duration Scan
Dynamic positron emission tomography (PET) parametric imaging typically requires a 60-minute acquisition period, causing patient discomfort and reducing clinical efficiency. This study explores the feasibility of generating parametric Ki images from 10-minute dynamic PET images acquired in the early or late scanning phases employing a multi-channel feature fusion cold sampling (MCFFCoS) framework. PET data from 103 patients are acquired using the uEXPLORER total-body PET/CT scanner during 60-minute scans. This study conducts deep learning experiments, taking early-phase or late-phase PET images as input, respectively. The generated Ki images are evaluated by visual quality and quantitative metrics, including root mean squared error (RMSE), structural similarity index (SSIM), and peak signal-to-noise ratio (PSNR). Volumes of interest (VOIs) analysis is performed using linear regression and Bland-Altman plots. In the quantitative evaluation of total-body data, the parametric Ki images generated from late-phase PET data generally outperform those derived from early-phase data. The analysis of VOIs indicates that the appropriate scanning protocol for PET parametric imaging may vary for different body regions. The deep learning approach is able to generate high-quality parametric Ki images from 10-minute dynamic PET scans, bypassing the requirements of long acquisition time for the estimation of blood input function in kinetic modeling.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (8) , 1062-1073
Dual-Prompt-Enhanced Multiorgan Segmentation Model for Total-Body PET Images
Multi-organ segmentation in total-body PET images is crucial for accurately locating abnormalities and assisting in the observation of corresponding metabolic regions in the human body. Despite the emergence of numerous advanced methods in the field of multi-organ segmentation in recent years, available PET image segmentation techniques remain relatively limited. The complexity and variability of textures in PET images, the varying visibility and contrast of organs due to different metabolic activities, and the challenges posed by blurred organ boundaries in PET images all contribute to the increased difficulty of multi-organ segmentation. In this paper, we propose the Dual-Prompt Enhanced Multi-Organ Segmentation Model (DPESeg) for total-body PET image segmentation. Our approach focuses on enhancing the model’s ability to perceive organ thresholds and shapes by introducing textual and disentangled organ features, thereby improving segmentation accuracy. We validate our model on a dataset of total-body PET images obtained from 110 patients. Both visual and quantitative results demonstrate that DPESeg performs well in the multi-organ segmentation task, with a 2.02% improvement in the Dice coefficient and a 1.90% improvement in the Jaccard index compared to the best-performing comparison algorithm.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (8) , 1062-1073
Dual-Prompt-Enhanced Multiorgan Segmentation Model for Total-Body PET Images
Multi-organ segmentation in total-body PET images is crucial for accurately locating abnormalities and assisting in the observation of corresponding metabolic regions in the human body. Despite the emergence of numerous advanced methods in the field of multi-organ segmentation in recent years, available PET image segmentation techniques remain relatively limited. The complexity and variability of textures in PET images, the varying visibility and contrast of organs due to different metabolic activities, and the challenges posed by blurred organ boundaries in PET images all contribute to the increased difficulty of multi-organ segmentation. In this paper, we propose the Dual-Prompt Enhanced Multi-Organ Segmentation Model (DPESeg) for total-body PET image segmentation. Our approach focuses on enhancing the model’s ability to perceive organ thresholds and shapes by introducing textual and disentangled organ features, thereby improving segmentation accuracy. We validate our model on a dataset of total-body PET images obtained from 110 patients. Both visual and quantitative results demonstrate that DPESeg performs well in the multi-organ segmentation task, with a 2.02% improvement in the Dice coefficient and a 1.90% improvement in the Jaccard index compared to the best-performing comparison algorithm.
- 13 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems for Video Technology
- Vol. 35 (6) , 6021-6033
Disentangle and Then Fuse: A Cross-Modal Network for Synthesizing Gadolinium-Enhanced Brain MR Images
Despite the widespread use of gadolinium-based contrast agents in clinical MRI examinations due to their significant advantages in structural localization and tumor identification, there is a risk of brain deposition and nephrogenic systemic fibrosis. Cross-modal image synthesis methods offer a new alternative, yet lesion synthesis remains challenging. On one hand, brain lesions vary significantly in location, shape, and size. On the other hand, the high background ratio associated with brain lesions makes their synthesis more difficult. To address these issues, we first introduce a Multi-Objective Local Perception Module (M-OLPM), which utilizes edge generation and lesion segmentation tasks to prioritize local lesions from the disentangled local perceptual feature subspaces. To better extend to multi-objective local perception, we propose a ’Disentangle and Then Fuse’ learning strategy, including a Feature Disentanglement Module (FDM) and a Global Fusion Module (GFM). The FDM decouples multimodal deep features into low-frequency semantic features and high-frequency edge features, alleviating feature conflicts from weakly related perception tasks. To enhance feature interaction among multiple perception tasks, the GFM progressively integrates these local perceptual features and underlying detail features through an attention mechanism, further refining the global image quality. Evaluated on the publicly available BRaTS2020, BRaTS2021 datasets, and the private HPPH dataset, our method significantly outperforms the existing technology in both visual and quantitative assessments of gadolinium-enhanced MRI images in global and localized lesion areas, providing a safe alternative to gadolinium enhancement. The source code is publicly available at https://github.com/zengyangche/DTF-Net.
- 13 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems for Video Technology
- Vol. 35 (6) , 6021-6033
Disentangle and Then Fuse: A Cross-Modal Network for Synthesizing Gadolinium-Enhanced Brain MR Images
Despite the widespread use of gadolinium-based contrast agents in clinical MRI examinations due to their significant advantages in structural localization and tumor identification, there is a risk of brain deposition and nephrogenic systemic fibrosis. Cross-modal image synthesis methods offer a new alternative, yet lesion synthesis remains challenging. On one hand, brain lesions vary significantly in location, shape, and size. On the other hand, the high background ratio associated with brain lesions makes their synthesis more difficult. To address these issues, we first introduce a Multi-Objective Local Perception Module (M-OLPM), which utilizes edge generation and lesion segmentation tasks to prioritize local lesions from the disentangled local perceptual feature subspaces. To better extend to multi-objective local perception, we propose a ’Disentangle and Then Fuse’ learning strategy, including a Feature Disentanglement Module (FDM) and a Global Fusion Module (GFM). The FDM decouples multimodal deep features into low-frequency semantic features and high-frequency edge features, alleviating feature conflicts from weakly related perception tasks. To enhance feature interaction among multiple perception tasks, the GFM progressively integrates these local perceptual features and underlying detail features through an attention mechanism, further refining the global image quality. Evaluated on the publicly available BRaTS2020, BRaTS2021 datasets, and the private HPPH dataset, our method significantly outperforms the existing technology in both visual and quantitative assessments of gadolinium-enhanced MRI images in global and localized lesion areas, providing a safe alternative to gadolinium enhancement. The source code is publicly available at https://github.com/zengyangche/DTF-Net.
- Open Access
- 9 January 2025
- Published by Springer Nature in BMC Cancer
- Vol. 25 (1) , 1-12
Estimation of TP53 mutations for endometrial cancer based on diffusion-weighted imaging deep learning and radiomics features
To construct a prediction model based on deep learning (DL) and radiomics features of diffusion weighted imaging (DWI), and clinical variables for evaluating TP53 mutations in endometrial cancer (EC). DWI and clinical data from 155 EC patients were included in this study, consisting of 80 in the training set, 35 in the test set, and 40 in the external validation set. Radiomics features, convolutional neural network-based DL features, and clinical variables were analyzed. Feature selection was performed using Mann-Whitney U test, LASSO regression, and SelectKBest. Prediction models were established by gaussian process (GP) and decision tree (DT) algorithms and evaluated by the area under the receiver operating characteristic curve (AUC), net reclassification index (NRI), calibration curves, and decision curve analysis (DCA). Compared to the DL (AUCtraining = 0.830, AUCtest = 0.779, and AUCvalidation = 0.711), radiomics (AUCtraining = 0.810, AUCtest = 0.710, and AUCvalidation = 0.839), and clinical (AUCtraining = 0.780, AUCtest = 0.685, and AUCvalidation = 0.695) models, the combined model based on the GP algorithm, which consisted of four DL features, five radiomics features, and two clinical variables, not only demonstrated the highest diagnostic efficacy (AUCtraining = 0.949, AUCtest = 0.877, and AUCvalidation = 0.914) but also led to an improvement in risk reclassification of the TP53 mutation (NIRtraining = 66.38%, 56.98%, and 83.48%, NIRtest = 50.72%, 80.43%, and 89.49%, and NIRvalidation = 64.58%, 87.50%, and 120.83%, respectively). In addition, the combined model exhibited good agreement and clinical utility in calibration curves and DCA analyses, respectively. A prediction model based on the GP algorithm and consisting of DL and radiomics features of DWI as well as clinical variables can effectively assess TP53 mutation in EC.
- 9 January 2025
- Published by Springer Nature in BMC Cancer
- Vol. 25 (1) , 1-12
Open AccessEstimation of TP53 mutations for endometrial cancer based on diffusion-weighted imaging deep learning and radiomics features
To construct a prediction model based on deep learning (DL) and radiomics features of diffusion weighted imaging (DWI), and clinical variables for evaluating TP53 mutations in endometrial cancer (EC). DWI and clinical data from 155 EC patients were included in this study, consisting of 80 in the training set, 35 in the test set, and 40 in the external validation set. Radiomics features, convolutional neural network-based DL features, and clinical variables were analyzed. Feature selection was performed using Mann-Whitney U test, LASSO regression, and SelectKBest. Prediction models were established by gaussian process (GP) and decision tree (DT) algorithms and evaluated by the area under the receiver operating characteristic curve (AUC), net reclassification index (NRI), calibration curves, and decision curve analysis (DCA). Compared to the DL (AUCtraining = 0.830, AUCtest = 0.779, and AUCvalidation = 0.711), radiomics (AUCtraining = 0.810, AUCtest = 0.710, and AUCvalidation = 0.839), and clinical (AUCtraining = 0.780, AUCtest = 0.685, and AUCvalidation = 0.695) models, the combined model based on the GP algorithm, which consisted of four DL features, five radiomics features, and two clinical variables, not only demonstrated the highest diagnostic efficacy (AUCtraining = 0.949, AUCtest = 0.877, and AUCvalidation = 0.914) but also led to an improvement in risk reclassification of the TP53 mutation (NIRtraining = 66.38%, 56.98%, and 83.48%, NIRtest = 50.72%, 80.43%, and 89.49%, and NIRvalidation = 64.58%, 87.50%, and 120.83%, respectively). In addition, the combined model exhibited good agreement and clinical utility in calibration curves and DCA analyses, respectively. A prediction model based on the GP algorithm and consisting of DL and radiomics features of DWI as well as clinical variables can effectively assess TP53 mutation in EC.
- 8 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (10) , 4073-4086
Prompt-Agent-Driven Integration of Foundation Model Priors for Low-Count PET Reconstruction
Low-count Positron Emission Tomography reconstruction is critical for maintaining high imaging quality while minimizing tracer doses and radiation exposure. Although integrating structural information from CT and MR data has been shown to enhance PET reconstruction, this typically requires simultaneous PET and CT/MRI scans, complicating workflows and increasing radiation exposure. Recent advancements in foundation models offer a promising alternative to in-person CT/MRI imaging, potentially overcoming these limitations. However, the use of foundation models’ segmentation masks as semantic guides has been observed to introduce erroneous structures in low-count PET reconstructions. To address this challenge, this work introduces an innovative prompting agent-based framework that dynamically interacts with the foundation model to retrieve and refine priors, minimizing undue influence on the reconstruction process. Specifically, a box agent is designed for single-instance local area information retrieval, while a point agent is introduced to progressively prompt broader semantic structures globally, utilizing history point prompts. Additionally, an MDP paradigm has been developed to address the challenges of utilizing historical point prompts while maintaining the independence required by MDPs. Evaluated on both simulated and real datasets, the proposed method demonstrates superior qualitative and quantitative performance compared to state-of-the-art methods, even those leveraging in-person CT/MRI priors.
- 8 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (10) , 4073-4086
Prompt-Agent-Driven Integration of Foundation Model Priors for Low-Count PET Reconstruction
Low-count Positron Emission Tomography reconstruction is critical for maintaining high imaging quality while minimizing tracer doses and radiation exposure. Although integrating structural information from CT and MR data has been shown to enhance PET reconstruction, this typically requires simultaneous PET and CT/MRI scans, complicating workflows and increasing radiation exposure. Recent advancements in foundation models offer a promising alternative to in-person CT/MRI imaging, potentially overcoming these limitations. However, the use of foundation models’ segmentation masks as semantic guides has been observed to introduce erroneous structures in low-count PET reconstructions. To address this challenge, this work introduces an innovative prompting agent-based framework that dynamically interacts with the foundation model to retrieve and refine priors, minimizing undue influence on the reconstruction process. Specifically, a box agent is designed for single-instance local area information retrieval, while a point agent is introduced to progressively prompt broader semantic structures globally, utilizing history point prompts. Additionally, an MDP paradigm has been developed to address the challenges of utilizing historical point prompts while maintaining the independence required by MDPs. Evaluated on both simulated and real datasets, the proposed method demonstrates superior qualitative and quantitative performance compared to state-of-the-art methods, even those leveraging in-person CT/MRI priors.
- 12 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (3) , 1982-1994
Automatic Brain Segmentation for PET/MR Dual-Modal Images Through a Cross-Fusion Mechanism
The precise segmentation of different brain regions and tissues is usually a prerequisite for the detection and diagnosis of various neurological disorders in neuroscience. Considering the abundance of functional and structural dual-modality information for positron emission tomography/magnetic resonance (PET/MR) images, we propose a novel 3D whole-brain segmentation network with a cross-fusion mechanism introduced to obtain 45 brain regions. Specifically, the network processes PET and MR images simultaneously, employing UX-Net and a cross-fusion block for feature extraction and fusion in the encoder. We test our method by comparing it with other deep learning-based methods, including 3DUXNET, SwinUNETR, UNETR, nnFormer, UNet3D, NestedUNet, ResUNet, and VNet. The experimental results demonstrate that the proposed method achieves better segmentation performance in terms of both visual and quantitative evaluation metrics and achieves more precise segmentation in three views while preserving fine details. In particular, the proposed method achieves superior quantitative results, with a Dice coefficient of 85.73% $\pm$ 0.01%, a Jaccard index of 76.68% $\pm$ 0.02%, a sensitivity of 85.00% $\pm$ 0.01%, a precision of 83.26% $\pm$ 0.03% and a Hausdorff distance (HD) of 4.4885 $\pm$ 14.86%. Moreover, the distribution and correlation of the SUV in the volume of interest (VOI) are also evaluated (PCC>0.9), indicating consistency with the ground truth and the superiority of the proposed method. In future work, we will utilize our whole-brain segmentation method in clinical practice to assist doctors in accurately diagnosing and treating brain diseases.
- 12 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (3) , 1982-1994
Automatic Brain Segmentation for PET/MR Dual-Modal Images Through a Cross-Fusion Mechanism
The precise segmentation of different brain regions and tissues is usually a prerequisite for the detection and diagnosis of various neurological disorders in neuroscience. Considering the abundance of functional and structural dual-modality information for positron emission tomography/magnetic resonance (PET/MR) images, we propose a novel 3D whole-brain segmentation network with a cross-fusion mechanism introduced to obtain 45 brain regions. Specifically, the network processes PET and MR images simultaneously, employing UX-Net and a cross-fusion block for feature extraction and fusion in the encoder. We test our method by comparing it with other deep learning-based methods, including 3DUXNET, SwinUNETR, UNETR, nnFormer, UNet3D, NestedUNet, ResUNet, and VNet. The experimental results demonstrate that the proposed method achieves better segmentation performance in terms of both visual and quantitative evaluation metrics and achieves more precise segmentation in three views while preserving fine details. In particular, the proposed method achieves superior quantitative results, with a Dice coefficient of 85.73% $\pm$ 0.01%, a Jaccard index of 76.68% $\pm$ 0.02%, a sensitivity of 85.00% $\pm$ 0.01%, a precision of 83.26% $\pm$ 0.03% and a Hausdorff distance (HD) of 4.4885 $\pm$ 14.86%. Moreover, the distribution and correlation of the SUV in the volume of interest (VOI) are also evaluated (PCC>0.9), indicating consistency with the ground truth and the superiority of the proposed method. In future work, we will utilize our whole-brain segmentation method in clinical practice to assist doctors in accurately diagnosing and treating brain diseases.