Kevin Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kevin Chen has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Ali Javey
Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, USA
2 shared publications Hossain M. Fahad
Materials Sciences Division, Lawrence Berkeley National Laboratory , Berkeley, California 94720, United States
2 shared publications- Abhishek Paul
NIT Silchar
1 shared publication - Carl Wassgren
School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA
1 shared publication Daisuke Kiriya
Electrical Engineering and Computer Sciences, University of California , Berkeley, California 94720, United States
1 shared publicationEric Wu
University of California, Berkeley
1 shared publication
Latest Publications
- 18 July 2023
- Published by Elsevier in Bioresource Technology Reports
- Vol. 23, 101554
A laboratory-scale compression feed screw for characterizing continuous feeding of dense granular materials
- 18 July 2023
- Published by Elsevier in Bioresource Technology Reports
- Vol. 23, 101554
A laboratory-scale compression feed screw for characterizing continuous feeding of dense granular materials
- 15 June 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12516, 21-108
Development of a 3D-printed, sensitivity-optimized fluorometer based on ultraviolet LED for VIS fluorescence spectrum analysis
This paper introduces a fluorometer that is both economically viable and optimized for sensitivity. The sensor is designed to detect low concentrations of fluorophores in the visible spectrum range, utilizing a deep ultraviolet (DUV) 275-nm LED and a dichroic mirror to establish a co-axial optical path for excitation and emission. Unlike traditional general-purpose spectrometers, this sensor achieves a balance between the two through an appropriate aperture size and tailored optical design optimized for the spectral characteristics of fluorophores. The manuscript presents measurements of rare earth element (REE) samples containing terbium (Tb), europium (Eu), dysprosium (Dy), and samarium (Sm) in aqueous solutions at ppb-level concentrations. By optimizing the collection of fluorescence emission without sacrificing spectral information, this work demonstrates the feasibility of developing a low-cost, compact, and highly sensitive fluorescence sensor that is comparable to bench-top commercial spectrofluorometers at a fraction of the cost.
- 15 June 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12516, 21-108
Development of a 3D-printed, sensitivity-optimized fluorometer based on ultraviolet LED for VIS fluorescence spectrum analysis
This paper introduces a fluorometer that is both economically viable and optimized for sensitivity. The sensor is designed to detect low concentrations of fluorophores in the visible spectrum range, utilizing a deep ultraviolet (DUV) 275-nm LED and a dichroic mirror to establish a co-axial optical path for excitation and emission. Unlike traditional general-purpose spectrometers, this sensor achieves a balance between the two through an appropriate aperture size and tailored optical design optimized for the spectral characteristics of fluorophores. The manuscript presents measurements of rare earth element (REE) samples containing terbium (Tb), europium (Eu), dysprosium (Dy), and samarium (Sm) in aqueous solutions at ppb-level concentrations. By optimizing the collection of fluorescence emission without sacrificing spectral information, this work demonstrates the feasibility of developing a low-cost, compact, and highly sensitive fluorescence sensor that is comparable to bench-top commercial spectrofluorometers at a fraction of the cost.
- Open Access
- 19 July 2017
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 2 (7) , 990-997
3D Printed “Earable” Smart Devices for Real-Time Detection of Core Body Temperature
Real-time detection of basic physiological parameters such as blood pressure and heart rate is an important target in wearable smart devices for healthcare. Among these, the core body temperature is one of the most important basic medical indicators of fever, insomnia, fatigue, metabolic functionality, and depression. However, traditional wearable temperature sensors are based upon the measurement of skin temperature, which can vary dramatically from the true core body temperature. Here, we demonstrate a three-dimensional (3D) printed wearable “earable” smart device that is designed to be worn on the ear to track core body temperature from the tympanic membrane (i.e., ear drum) based on an infrared sensor. The device is fully integrated with data processing circuits and a wireless module for standalone functionality. Using this smart earable device, we demonstrate that the core body temperature can be accurately monitored regardless of the environment and activity of the user. In addition, a microphone and actuator are also integrated so that the device can also function as a bone conduction hearing aid. Using 3D printing as the fabrication method enables the device to be customized for the wearer for more personalized healthcare. This smart device provides an important advance in realizing personalized health care by enabling real-time monitoring of one of the most important medical parameters, core body temperature, employed in preliminary medical screening tests.
- 19 July 2017
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 2 (7) , 990-997
Open Access3D Printed “Earable” Smart Devices for Real-Time Detection of Core Body Temperature
Real-time detection of basic physiological parameters such as blood pressure and heart rate is an important target in wearable smart devices for healthcare. Among these, the core body temperature is one of the most important basic medical indicators of fever, insomnia, fatigue, metabolic functionality, and depression. However, traditional wearable temperature sensors are based upon the measurement of skin temperature, which can vary dramatically from the true core body temperature. Here, we demonstrate a three-dimensional (3D) printed wearable “earable” smart device that is designed to be worn on the ear to track core body temperature from the tympanic membrane (i.e., ear drum) based on an infrared sensor. The device is fully integrated with data processing circuits and a wireless module for standalone functionality. Using this smart earable device, we demonstrate that the core body temperature can be accurately monitored regardless of the environment and activity of the user. In addition, a microphone and actuator are also integrated so that the device can also function as a bone conduction hearing aid. Using 3D printing as the fabrication method enables the device to be customized for the wearer for more personalized healthcare. This smart device provides an important advance in realizing personalized health care by enabling real-time monitoring of one of the most important medical parameters, core body temperature, employed in preliminary medical screening tests.
- 7 June 2017
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 9 (24) , 20648-20655
Nanoscale Junction Formation by Gas-Phase Monolayer Doping
A major challenge in transistor technology scaling is the formation of controlled ultrashallow junctions with nanometer-scale thickness and high spatial uniformity. Monolayer doping (MLD) is an efficient method to form such nanoscale junctions, where the self-limiting nature of semiconductor surfaces is utilized to form adsorbed monolayers of dopant-containing molecules followed by rapid thermal annealing (RTA) to diffuse the dopants to a desired depth. Unlike ion implantation, the process does not induce crystal damage, thus making it highly attractive for nanoscale transistor processing. To date, reported MLD processes have relied on solution processing for monolayer formation. Gas-phase processing, however, benefits from higher intra- and interwafer uniformity and conformal coverage of 3D structures and is more desirable for manufacturing. In this regard, we report a new approach for MLD in silicon and germanium using gas-phase monolayer formation. We call this technology gas-phase monolayer doping (GP-MLD). This method relies on sequential pulse–purge cycles of gas-phase dopant-containing molecules to form a boron- or phosphorus-containing monolayer on a target semiconductor surface. Here, we show the feasibility of our approach through the formation of ultrashallow B- and P-doped junctions on Si and Ge surfaces. The mechanism of adsorption is characterized using Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy. Sub-5 nm junction depths with high dopant dose are obtained as characterized by secondary ion mass spectrometry and sheet resistance measurements. Additionally, we demonstrate that area selectivity can be achieved via lithographic patterning of the monolayer dopants before the diffusion step. The results demonstrate the versatility of the GP-MLD approach for formation of controlled and ultrashallow junctions.
- 7 June 2017
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 9 (24) , 20648-20655
Nanoscale Junction Formation by Gas-Phase Monolayer Doping
A major challenge in transistor technology scaling is the formation of controlled ultrashallow junctions with nanometer-scale thickness and high spatial uniformity. Monolayer doping (MLD) is an efficient method to form such nanoscale junctions, where the self-limiting nature of semiconductor surfaces is utilized to form adsorbed monolayers of dopant-containing molecules followed by rapid thermal annealing (RTA) to diffuse the dopants to a desired depth. Unlike ion implantation, the process does not induce crystal damage, thus making it highly attractive for nanoscale transistor processing. To date, reported MLD processes have relied on solution processing for monolayer formation. Gas-phase processing, however, benefits from higher intra- and interwafer uniformity and conformal coverage of 3D structures and is more desirable for manufacturing. In this regard, we report a new approach for MLD in silicon and germanium using gas-phase monolayer formation. We call this technology gas-phase monolayer doping (GP-MLD). This method relies on sequential pulse–purge cycles of gas-phase dopant-containing molecules to form a boron- or phosphorus-containing monolayer on a target semiconductor surface. Here, we show the feasibility of our approach through the formation of ultrashallow B- and P-doped junctions on Si and Ge surfaces. The mechanism of adsorption is characterized using Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy. Sub-5 nm junction depths with high dopant dose are obtained as characterized by secondary ion mass spectrometry and sheet resistance measurements. Additionally, we demonstrate that area selectivity can be achieved via lithographic patterning of the monolayer dopants before the diffusion step. The results demonstrate the versatility of the GP-MLD approach for formation of controlled and ultrashallow junctions.