Anoop Kumar Gupta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anoop Kumar Gupta has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Rajendra Prasad Chhabra
Department of Chemical Engineering, Indian Institute of Technology Kanpur, Kanpur 208016, India
10 shared publications R.P. Chhabra
6 shared publicationsLalan K. Singh
Indian Inst Technol Patna, Dept Chem & Biochem Engn, Energy & Thermofluids Lab, Amhara Rd, Patna 801106, Bihar, India
5 shared publicationsRajesh Kumar
5 shared publicationsTabrez Alam
5 shared publicationsN. Nirmalkar
3 shared publications
Latest Publications
- 26 December 2024
- Published by Elsevier in Chemical Engineering Research and Design
- Vol. 214, 125-143
Effect of enclosure design with composite/nano-enhanced/dual phase change material on melting response of latent heat storage systems
- 26 December 2024
- Published by Elsevier in Chemical Engineering Research and Design
- Vol. 214, 125-143
Effect of enclosure design with composite/nano-enhanced/dual phase change material on melting response of latent heat storage systems
- 24 June 2024
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 102 (11) , 3852-3866
Effects of segmentation in composite phase change material on melting/solidification performance of triplex‐tube thermal energy storage systems
In this work, a numerical evaluation of the melting/solidification performance of phase change material (PCM) filled inside a triplex‐tube latent heat storage unit has been carried out. To enhance the melting/solidification performance, the porous Cu metal foam (MF) was embedded inside PCM (termed as composite PCM). Alternative segments of pure PCM and composite PCM have been allocated in such a way that both the pure PCM and composite PCM occupy the equal annular area (i.e., equal volumes). Influence of increasing number of segments was delineated on the melting/solidification rate, complete melting time, and thermal energy storage/recovery enhancement. The comparisons were drawn with reference to the model having two segments of PCM and composite PCM. The results show that the model containing 64 segments with alternate allocations of PCM and composite PCM has a faster melting/solidification rate than other models. With 32 alternate segments of MF, the full melting/solidification time reduced by 23%/77% with respect to the case with one segment of MF only. The melting/solidification performance gets saturated beyond 32 segments (M‐5) and negligible variation (only ~1%) in the thermal performance was noticed upon further segmentation. Finally, the model M‐5 proved as the best model considering the aspects of augmented melting/solidification rate and associated complexities. Moreover, the heterogeneity of MF applied in 32‐segment model confirmed that the anisotropic MF results in an increased melting rate and leads over other random isotropic distributions of MF.
- 24 June 2024
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 102 (11) , 3852-3866
Effects of segmentation in composite phase change material on melting/solidification performance of triplex‐tube thermal energy storage systems
In this work, a numerical evaluation of the melting/solidification performance of phase change material (PCM) filled inside a triplex‐tube latent heat storage unit has been carried out. To enhance the melting/solidification performance, the porous Cu metal foam (MF) was embedded inside PCM (termed as composite PCM). Alternative segments of pure PCM and composite PCM have been allocated in such a way that both the pure PCM and composite PCM occupy the equal annular area (i.e., equal volumes). Influence of increasing number of segments was delineated on the melting/solidification rate, complete melting time, and thermal energy storage/recovery enhancement. The comparisons were drawn with reference to the model having two segments of PCM and composite PCM. The results show that the model containing 64 segments with alternate allocations of PCM and composite PCM has a faster melting/solidification rate than other models. With 32 alternate segments of MF, the full melting/solidification time reduced by 23%/77% with respect to the case with one segment of MF only. The melting/solidification performance gets saturated beyond 32 segments (M‐5) and negligible variation (only ~1%) in the thermal performance was noticed upon further segmentation. Finally, the model M‐5 proved as the best model considering the aspects of augmented melting/solidification rate and associated complexities. Moreover, the heterogeneity of MF applied in 32‐segment model confirmed that the anisotropic MF results in an increased melting rate and leads over other random isotropic distributions of MF.
- 12 December 2023
- Published by Wiley in Energy Technology
- Vol. 12 (2)
Evaluating Air‐Cooling Performance of Lithium‐Ion‐Battery Module with Various Cell Arrangements
The significant heat generated during the operation of lithium‐ion batteries raises the battery temperature thereby leading to performance degradation and thermal runaway in a thermal abuse environment. Therefore, a simple but effective battery thermal management system (BTMS) is crucial to achieve the permissible operating temperatures. In this work, the performance of air‐cooled BTMS is evaluated by changing the arrangement of cells under discharging conditions. Seven distinct arrangements (trapezoidal, slanted, cross, aligned, staggered, tilted square, and zigzag) of lithium‐ion cells are investigated in a rectangular battery pack. Two‐way coupling of 1D electrochemical model and 2D conjugate thermal‐fluid model is employed. The increasing Reynolds number reduces the cell temperature due to augmented convective effects. Under otherwise identical conditions, the zigzag cell arrangement outperforms the other cell arrangements but at the expense of the highest pressure drop (≈threefold). Particularly, the values of average and maximum cell temperature are reduced by ≈5K and ≈4K, respectively, for Re = 1000 at 1C in comparison to the aligned cell arrangement. Similarly, the least favorable performance is predicted by the trapezoidal, slanted, and cross‐cell arrangements. Finally, a performance plot is suggested considering the trade‐off between the power requirement and the cooling enhancement.
- 12 December 2023
- Published by Wiley in Energy Technology
- Vol. 12 (2)
Evaluating Air‐Cooling Performance of Lithium‐Ion‐Battery Module with Various Cell Arrangements
The significant heat generated during the operation of lithium‐ion batteries raises the battery temperature thereby leading to performance degradation and thermal runaway in a thermal abuse environment. Therefore, a simple but effective battery thermal management system (BTMS) is crucial to achieve the permissible operating temperatures. In this work, the performance of air‐cooled BTMS is evaluated by changing the arrangement of cells under discharging conditions. Seven distinct arrangements (trapezoidal, slanted, cross, aligned, staggered, tilted square, and zigzag) of lithium‐ion cells are investigated in a rectangular battery pack. Two‐way coupling of 1D electrochemical model and 2D conjugate thermal‐fluid model is employed. The increasing Reynolds number reduces the cell temperature due to augmented convective effects. Under otherwise identical conditions, the zigzag cell arrangement outperforms the other cell arrangements but at the expense of the highest pressure drop (≈threefold). Particularly, the values of average and maximum cell temperature are reduced by ≈5K and ≈4K, respectively, for Re = 1000 at 1C in comparison to the aligned cell arrangement. Similarly, the least favorable performance is predicted by the trapezoidal, slanted, and cross‐cell arrangements. Finally, a performance plot is suggested considering the trade‐off between the power requirement and the cooling enhancement.
- 19 June 2023
- Published by Elsevier in Thermal Science and Engineering Progress
- Vol. 43, 101964
A novel strategy of enhanced thermal performance in air cooled lithium-ion battery by wavy walls
- 19 June 2023
- Published by Elsevier in Thermal Science and Engineering Progress
- Vol. 43, 101964
A novel strategy of enhanced thermal performance in air cooled lithium-ion battery by wavy walls
- 4 May 2023
- Published by Walter de Gruyter GmbH in Chemical Product and Process Modeling
- Vol. 18 (5) , 823-837
Simultaneous charging and discharging of metal foam composite phase change material in triplex-tube latent heat storage system under various configurations
Phase change material (PCM) has high latent heat on one hand albeit low thermal conductivity on the other hand which restricts its utilization in thermal energy storage applications. Therefore, to improve thermal performance of PCM, various techniques have been employed. This numerical work intends to estimate the effect of copper metal foam (MF) in the seven various configurations (M1–M7) of triple-tube heat exchanger (TTHX) under simultaneous charging and discharging (SCD) conditions using heat transfer fluids (HTF) both the sides. Five distinct configurations with equal volumes of PCM and composite PCM (CPCM) have been considered for optimization standpoint. RT55 (melting temperature = 327 K) is taken as PCM. Based on thermo-physical properties of PCM and thermal boundary conditions on the heated tube, the dimensionless controlling parameters such as the Rayleigh number ( Ra ), Prandtl number ( Pr ), and Stefan number ( Ste ) were taken as 1.79 × 10 5 , 30, and 0.21, respectively. Typical results on melt fraction, latent heat storage, temperature contours, and steady-state melt fraction and corresponding melting time have been reported. Performance yielded by all the configurations was compared for a fixed duration of 2 h. The positioning of MF largely affects the heat transfer mechanism in the latent heat storage unit. Results show that the bottom-side positioning of MF can boost the heat storage due to enhanced buoyancy-induced convection. Among all the models, M3 predicts the highest steady-state melt fraction ( λ $\lambda $ ss ≈ 0.62) in the shortest steady-state melting time ( t ss ≈ 66 min), followed by model M6 ( λ ss ≈ 0.58, t ss ≈ 65 min). The optimized design (model M3) shows ∼75 % latent heat storage enhancement than pure PCM (M1) case. Interestingly, one may also achieve ∼17.2 % higher enhancement using model M3 than M2 but with only half of the mass of MF than that used in full porous configuration (M2).- 4 May 2023
- Published by Walter de Gruyter GmbH in Chemical Product and Process Modeling
- Vol. 18 (5) , 823-837
Simultaneous charging and discharging of metal foam composite phase change material in triplex-tube latent heat storage system under various configurations
Phase change material (PCM) has high latent heat on one hand albeit low thermal conductivity on the other hand which restricts its utilization in thermal energy storage applications. Therefore, to improve thermal performance of PCM, various techniques have been employed. This numerical work intends to estimate the effect of copper metal foam (MF) in the seven various configurations (M1–M7) of triple-tube heat exchanger (TTHX) under simultaneous charging and discharging (SCD) conditions using heat transfer fluids (HTF) both the sides. Five distinct configurations with equal volumes of PCM and composite PCM (CPCM) have been considered for optimization standpoint. RT55 (melting temperature = 327 K) is taken as PCM. Based on thermo-physical properties of PCM and thermal boundary conditions on the heated tube, the dimensionless controlling parameters such as the Rayleigh number ( Ra ), Prandtl number ( Pr ), and Stefan number ( Ste ) were taken as 1.79 × 10 5 , 30, and 0.21, respectively. Typical results on melt fraction, latent heat storage, temperature contours, and steady-state melt fraction and corresponding melting time have been reported. Performance yielded by all the configurations was compared for a fixed duration of 2 h. The positioning of MF largely affects the heat transfer mechanism in the latent heat storage unit. Results show that the bottom-side positioning of MF can boost the heat storage due to enhanced buoyancy-induced convection. Among all the models, M3 predicts the highest steady-state melt fraction ( λ $\lambda $ ss ≈ 0.62) in the shortest steady-state melting time ( t ss ≈ 66 min), followed by model M6 ( λ ss ≈ 0.58, t ss ≈ 65 min). The optimized design (model M3) shows ∼75 % latent heat storage enhancement than pure PCM (M1) case. Interestingly, one may also achieve ∼17.2 % higher enhancement using model M3 than M2 but with only half of the mass of MF than that used in full porous configuration (M2).- Open Access
- 17 April 2022
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 34
Computational study on effect of enclosure shapes on melting characteristics of phase change material around a heated cylinder
- 17 April 2022
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 34
Open AccessComputational study on effect of enclosure shapes on melting characteristics of phase change material around a heated cylinder
- 1 March 2022
- Published by Springer Nature in Environment, Development and Sustainability
- Vol. 25 (4) , 3627-3648
Hybrid cooling-based lithium-ion battery thermal management for electric vehicles
- 1 March 2022
- Published by Springer Nature in Environment, Development and Sustainability
- Vol. 25 (4) , 3627-3648
Hybrid cooling-based lithium-ion battery thermal management for electric vehicles