Ricardo Adriano Dorledo de Faria
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ricardo Adriano Dorledo de Faria has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Luiz Guilherme Dias Heneine
Laboratory of Applied Immunology, Fundação Ezequiel Dias (FUNED), Minas Gerais, Brazil
7 shared publications- Renata Braga Soares
Universidade Federal de Minas Gerais, Brasil
5 shared publications Tulio Matencio
Department of Chemistry, Universidade Federal de Minas Gerais (UFMG), Minas Gerais, Brazil
5 shared publications- Tulio Matencio
Departamento de Química/ICEx, Universidade Federal de Minas Gerais, Av. Antônio Carlos, 6627, Pampulha, Belo Horizonte CEP 31270-901, MG, Brazil
5 shared publications Hassan Iden
Center for Optics, Photonics and Lasers (COPL), Université Laval, Quebec, Canada
3 shared publicationsVanessa de Freitas Cunha Lins
Department of Chemical Engineering, Universidade Federal de Minas Gerais (UFMG), Minas Gerais, 30270-901, Brazil
3 shared publications
Latest Publications
- Open Access
- 1 January 2021
- Published by Editora Cubo in Tecnologia em Metalurgia, Materiais e Mineração
- Vol. 18, e2425
Análise da influência das condições de envelhecimento na resistência mecânica e à corrosão do aço UNS S31803
Tecnol. Metal. Mater. Min., vol.18, e2425, 2021
- 1 January 2021
- Published by Editora Cubo in Tecnologia em Metalurgia, Materiais e Mineração
- Vol. 18, e2425
Open AccessAnálise da influência das condições de envelhecimento na resistência mecânica e à corrosão do aço UNS S31803
Tecnol. Metal. Mater. Min., vol.18, e2425, 2021
- 20 August 2020
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 31 (18) , 16087
Correction to: A novel impedimetric sensor for trace level detection of dimethyl sulfide (DMS)
- 20 August 2020
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 31 (18) , 16087
Correction to: A novel impedimetric sensor for trace level detection of dimethyl sulfide (DMS)
- 3 June 2020
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 31 (13) , 10940
Correction to: A novel impedimetric sensor for trace level detection of dimethyl sulfide (DMS)
- 3 June 2020
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 31 (13) , 10940
Correction to: A novel impedimetric sensor for trace level detection of dimethyl sulfide (DMS)
- 21 May 2020
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 31 (13) , 10398-10407
A novel impedimetric sensor for trace level detection of dimethyl sulfide (DMS)
- 21 May 2020
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 31 (13) , 10398-10407
A novel impedimetric sensor for trace level detection of dimethyl sulfide (DMS)
- 11 March 2020
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 76 (6) , 553-561
Electrochemical Behavior of Screen-Printed Carbon Electrodes as Transducers in Biosensors
Screen-printed carbon electrode (SPCE) was examined as a transducer substrate for application in electrochemical sensors. Aqueous solutions of 0.1 M KCl and 0.1 M KCl + 5 mM K3[Fe(CN)6]/K4[Fe(CN)6] (redox solution) were prepared to simulate the environment of faradaic and non-faradaic sensing, respectively. The SPCE presented an irregular surface composed by two main carbon phases. Raman spectroscopy results revealed the presence of peaks around 1,580 cm−1 and 1,334 cm−1 related to the G and D bands corresponding to sp2 carbon atoms (graphite flakes) and a multitude of broad bands associable to amorphous sp3 carbon in the ink matrix. Conductive atomic force microscopy indicated that the irregular structure of the SPCE led to the heterogeneous distribution of the current over the surface and the electroactivity of this material was mainly attributed to the presence of graphite. Polarization curves and electrochemical impedance spectroscopy (EIS) revealed that the redox solution was more aggressive to the SPCE, despite this electrode was achieved a quasi-steady state for 1 h under the effect of a polarization potential in both electrolytes, which justifies its use as an electrochemical transducer in faradaic and non-faradaic devices.
- 11 March 2020
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 76 (6) , 553-561
Electrochemical Behavior of Screen-Printed Carbon Electrodes as Transducers in Biosensors
Screen-printed carbon electrode (SPCE) was examined as a transducer substrate for application in electrochemical sensors. Aqueous solutions of 0.1 M KCl and 0.1 M KCl + 5 mM K3[Fe(CN)6]/K4[Fe(CN)6] (redox solution) were prepared to simulate the environment of faradaic and non-faradaic sensing, respectively. The SPCE presented an irregular surface composed by two main carbon phases. Raman spectroscopy results revealed the presence of peaks around 1,580 cm−1 and 1,334 cm−1 related to the G and D bands corresponding to sp2 carbon atoms (graphite flakes) and a multitude of broad bands associable to amorphous sp3 carbon in the ink matrix. Conductive atomic force microscopy indicated that the irregular structure of the SPCE led to the heterogeneous distribution of the current over the surface and the electroactivity of this material was mainly attributed to the presence of graphite. Polarization curves and electrochemical impedance spectroscopy (EIS) revealed that the redox solution was more aggressive to the SPCE, despite this electrode was achieved a quasi-steady state for 1 h under the effect of a polarization potential in both electrolytes, which justifies its use as an electrochemical transducer in faradaic and non-faradaic devices.
- 7 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (23) , 11624-11633
Detection of Neuromuscular Activity Using New Non-Invasive and Flexible Multimaterial Fiber Dry-Electrodes
A new non-invasive and flexible sensor was fabricated to monitor the muscular activity of upper body muscles. It consists of a dry electrode made of multimaterial metal-polymerglass hollow-core fiber electrodes connected to a custom made signal acquisition platform. This fiber electrode only adds a negligible contribution to the recording systems internal noise (7.626 μV peak-to-peak and 1.234 μV RMS; recording system noise: 6.901 μV peak-to-peak and 1.205 μV RMS). Surface electromyograms (sEMGs) of the biceps bracci and trapezius muscles were recorded during maximal voluntary contractions using the new sensor and compared to that obtained with medical grade commercial sensors. Frequency content and time domain analysis show that the new flexible sensor performs similarly to commercial devices in terms of sEMG signal amplitude discrimination and frequency shift evaluation during the development of muscle fatigue. The advantage of the new sensor is the high flexibility of the fibers allowing their easy integration into stretchable garments without compromising the user’s comfort. This will lead to the development of a new generation of smart textile with large application for telemedicine and assistive devices.
- 7 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (23) , 11624-11633
Detection of Neuromuscular Activity Using New Non-Invasive and Flexible Multimaterial Fiber Dry-Electrodes
A new non-invasive and flexible sensor was fabricated to monitor the muscular activity of upper body muscles. It consists of a dry electrode made of multimaterial metal-polymerglass hollow-core fiber electrodes connected to a custom made signal acquisition platform. This fiber electrode only adds a negligible contribution to the recording systems internal noise (7.626 μV peak-to-peak and 1.234 μV RMS; recording system noise: 6.901 μV peak-to-peak and 1.205 μV RMS). Surface electromyograms (sEMGs) of the biceps bracci and trapezius muscles were recorded during maximal voluntary contractions using the new sensor and compared to that obtained with medical grade commercial sensors. Frequency content and time domain analysis show that the new flexible sensor performs similarly to commercial devices in terms of sEMG signal amplitude discrimination and frequency shift evaluation during the development of muscle fatigue. The advantage of the new sensor is the high flexibility of the fibers allowing their easy integration into stretchable garments without compromising the user’s comfort. This will lead to the development of a new generation of smart textile with large application for telemedicine and assistive devices.
- Open Access
- 30 July 2019
- Published by Croatian Society of Chemical Engineers/HDKI in Chemical and Biochemical Engineering Quarterly
- Vol. 33 (2) , 221-227
Electrochemical Behavior of AISI 1020 Steel in Type C Commercial Gasolines
In the present paper, the corrosion behavior of 1020 carbon steel in commercial gasoline-ethanol blends was investigated. The composition of each gasoline-ethanol blend was evaluated by infrared spectroscopy, and the ethanol content was determined by the ABNT 13992 reference method. Electrochemical Impedance Spectroscopy (EIS) and polarization methods were employed to evaluate corrosion resistance and penetration rates. Statistical analyses revealed that the gasoline’s solution resistance governs the corrosion process, the RON (Research Octane Number) and MON (Motor Octane Number) numbers as well as the olefin content being more related to the corrosion rates. The polarization resistance had minor impact on the corrosion process.
- 30 July 2019
- Published by Croatian Society of Chemical Engineers/HDKI in Chemical and Biochemical Engineering Quarterly
- Vol. 33 (2) , 221-227
Open AccessElectrochemical Behavior of AISI 1020 Steel in Type C Commercial Gasolines
In the present paper, the corrosion behavior of 1020 carbon steel in commercial gasoline-ethanol blends was investigated. The composition of each gasoline-ethanol blend was evaluated by infrared spectroscopy, and the ethanol content was determined by the ABNT 13992 reference method. Electrochemical Impedance Spectroscopy (EIS) and polarization methods were employed to evaluate corrosion resistance and penetration rates. Statistical analyses revealed that the gasoline’s solution resistance governs the corrosion process, the RON (Research Octane Number) and MON (Motor Octane Number) numbers as well as the olefin content being more related to the corrosion rates. The polarization resistance had minor impact on the corrosion process.
- Open Access
- 21 May 2019
- Published by Biomedical Research Network, LLC in Biomedical Journal of Scientific & Technical Research
- Vol. 18 (2) , 13382-13388
AISI 304 Stainless Steel as a Transducer Substrate in Electrochemical Biosensors for Medical Applications
For many reasons, the material sciences have focused in studies of electroanalysis, exploring the knowledge of conductive materials that can be used as sensitive elements for composing sensors in order to specifically recognize analytes of interest [1].
- 21 May 2019
- Published by Biomedical Research Network, LLC in Biomedical Journal of Scientific & Technical Research
- Vol. 18 (2) , 13382-13388
Open AccessAISI 304 Stainless Steel as a Transducer Substrate in Electrochemical Biosensors for Medical Applications
For many reasons, the material sciences have focused in studies of electroanalysis, exploring the knowledge of conductive materials that can be used as sensitive elements for composing sensors in order to specifically recognize analytes of interest [1].
- Open Access
- 9 May 2019
- Published by MedCrave Group Kft. in International Journal of Biosensors & Bioelectronics
- Vol. 5 (3)
Recent trends in the electroanalytical detection of food fraud
- 9 May 2019
- Published by MedCrave Group Kft. in International Journal of Biosensors & Bioelectronics
- Vol. 5 (3)
Open AccessRecent trends in the electroanalytical detection of food fraud
- Open Access
Non-Enzymatic Impedimetric Sensor Based on 3-Aminophenylboronic Acid Functionalized Screen-Printed Carbon Electrode for Highly Sensitive Glucose Detection
A highly sensitive glucose sensor was prepared by a one-step method using 3-aminophenyl boronic acid as a unit of recognition and a screen-printed carbon electrode (SPCE) as an electrochemical transducer. Scanning Electron Microscopy confirmed the success of the functionalization of the SPCE due to the presence of clusters of boronic acid distributed on the carbon surface. In agreement with the Electrochemical Impedance Spectroscopy (EIS) tests performed before and after the functionalization, Cyclic Voltammetry results indicated that the electroactivity of the electrode decreased 37.9% owing to the presence of the poly phenylboronic acid on the electrode surface. EIS revealed that the sensor was capable to selectively detect glucose at a broad range of concentrations (limit of detection of 8.53 × 10−9 M), not recognizing fructose and sucrose. The device presented a stable impedimetric response when immediately prepared but suffered the influence of the storage time and some interfering species (dopamine, NaCl and animal serum). The response time at optimized conditions was estimated to be equal to 4.0 ± 0.6 s.
Open AccessNon-Enzymatic Impedimetric Sensor Based on 3-Aminophenylboronic Acid Functionalized Screen-Printed Carbon Electrode for Highly Sensitive Glucose Detection
A highly sensitive glucose sensor was prepared by a one-step method using 3-aminophenyl boronic acid as a unit of recognition and a screen-printed carbon electrode (SPCE) as an electrochemical transducer. Scanning Electron Microscopy confirmed the success of the functionalization of the SPCE due to the presence of clusters of boronic acid distributed on the carbon surface. In agreement with the Electrochemical Impedance Spectroscopy (EIS) tests performed before and after the functionalization, Cyclic Voltammetry results indicated that the electroactivity of the electrode decreased 37.9% owing to the presence of the poly phenylboronic acid on the electrode surface. EIS revealed that the sensor was capable to selectively detect glucose at a broad range of concentrations (limit of detection of 8.53 × 10−9 M), not recognizing fructose and sucrose. The device presented a stable impedimetric response when immediately prepared but suffered the influence of the storage time and some interfering species (dopamine, NaCl and animal serum). The response time at optimized conditions was estimated to be equal to 4.0 ± 0.6 s.