Jaime L. Shaw
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jaime L. Shaw has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
- Anthony G. Christodoulou
Department of Radiological Sciences David Geffen School of Medicine at UCLA Los Angeles California USA
5 shared publications Debiao Li
Biomedical Imaging Research Institute Cedars‐Sinai Medical Center Los Angeles California
5 shared publications- Reza Nezafat
Beth Israel Deaconess Medical Center and Harvard Medical School
5 shared publications Hussein Rayatzadeh
Department of Medicine, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
4 shared publicationsWarren J. Manning
Division of Cardiology, Beth Israel Deaconess Medical Center, Harvard University, Boston, MA (M.L.C., W.J.M.).
4 shared publications- Debiao Li
Biomedical Imaging Research Institute, Cedars‐Sinai Medical Center Los Angeles California USA
3 shared publications
Latest Publications
- 1 February 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 17 (2) , e016090
Meta-Analysis of Normal Reference Values for Right and Left Ventricular Quantification by Cardiovascular Magnetic Resonance
BACKGROUND: Cardiovascular magnetic resonance (CMR) reference values are relied upon to accurately diagnose left ventricular (LV) and right ventricular (RV) pathologies. To date, reference values have been derived from modest sample sizes with limited patient diversity and attention to 1 but not both commonly used tracing techniques for papillary muscles and trabeculations. We sought to overcome these limitations by meta-analyzing normal reference values for CMR parameters stemming from multiple countries, vendors, analysts, and patient populations. METHODS: We comprehensively extracted published and unpublished data from studies reporting CMR parameters in healthy adults. A steady-state free-precession short-axis stack at 1.5T or 3T was used to trace either counting the papillary muscles and trabeculations in the LV volume or mass. We used a novel Bayesian hierarchical meta-analysis model to derive the pooled lower and upper reference values for each CMR parameter. Our model accounted for the expected differences between tracing techniques by including informative prior distributions from a large external data set. RESULTS: A total of 254 studies from 25 different countries were systematically reviewed, representing 12 812 healthy adults, of which 52 were meta-analyzed. For LV parameters counting papillary muscles and trabeculations in the LV volume, pooled normative reference ranges in men and women, respectively, were as follows: LV ejection fraction of 52% to 73% and 54% to 75%, LV end-diastolic volume index of 60 to 109 and 56 to 96 mL/m 2 , LV end-systolic volume index of 18 to 45 and 16 to 38 mL/m 2 , and LV mass index of 41 to 76 and 33 to 57 g/m 2 . For LV parameters counting papillary muscles and trabeculations in the LV mass, pooled normative reference ranges in men and women, respectively, were as follows: LV ejection fraction of 57% to 74% and 57% to 75%, LV end-diastolic volume index of 60 to 97 and 55 to 88 mL/m 2 , LV end-systolic volume index of 18 to 37 and 15 to 34 mL/m 2 , and LV mass index of 50 to 83 and 38 to 65 g/m 2 . For RV parameters, pooled normative reference ranges in men and women, respectively, were as follows: RV ejection fraction of 47% to 68% and 49% to 71%, RV end-diastolic volume index of 64 to 115 and 57 to 99 mL/m 2 , RV end-systolic volume index of 23 to 52 and 18 to 42 mL/m 2 , and RV mass index of 14 to 29 and 13 to 25 g/m 2 . CONCLUSIONS: Our Bayesian hierarchical meta-analysis provides normative reference values for CMR parameters of LV and RV size, systolic function, and mass, encompassing both tracing techniques across a diverse multinational sample of healthy men and women.
- 1 February 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 17 (2) , e016090
Meta-Analysis of Normal Reference Values for Right and Left Ventricular Quantification by Cardiovascular Magnetic Resonance
BACKGROUND: Cardiovascular magnetic resonance (CMR) reference values are relied upon to accurately diagnose left ventricular (LV) and right ventricular (RV) pathologies. To date, reference values have been derived from modest sample sizes with limited patient diversity and attention to 1 but not both commonly used tracing techniques for papillary muscles and trabeculations. We sought to overcome these limitations by meta-analyzing normal reference values for CMR parameters stemming from multiple countries, vendors, analysts, and patient populations. METHODS: We comprehensively extracted published and unpublished data from studies reporting CMR parameters in healthy adults. A steady-state free-precession short-axis stack at 1.5T or 3T was used to trace either counting the papillary muscles and trabeculations in the LV volume or mass. We used a novel Bayesian hierarchical meta-analysis model to derive the pooled lower and upper reference values for each CMR parameter. Our model accounted for the expected differences between tracing techniques by including informative prior distributions from a large external data set. RESULTS: A total of 254 studies from 25 different countries were systematically reviewed, representing 12 812 healthy adults, of which 52 were meta-analyzed. For LV parameters counting papillary muscles and trabeculations in the LV volume, pooled normative reference ranges in men and women, respectively, were as follows: LV ejection fraction of 52% to 73% and 54% to 75%, LV end-diastolic volume index of 60 to 109 and 56 to 96 mL/m 2 , LV end-systolic volume index of 18 to 45 and 16 to 38 mL/m 2 , and LV mass index of 41 to 76 and 33 to 57 g/m 2 . For LV parameters counting papillary muscles and trabeculations in the LV mass, pooled normative reference ranges in men and women, respectively, were as follows: LV ejection fraction of 57% to 74% and 57% to 75%, LV end-diastolic volume index of 60 to 97 and 55 to 88 mL/m 2 , LV end-systolic volume index of 18 to 37 and 15 to 34 mL/m 2 , and LV mass index of 50 to 83 and 38 to 65 g/m 2 . For RV parameters, pooled normative reference ranges in men and women, respectively, were as follows: RV ejection fraction of 47% to 68% and 49% to 71%, RV end-diastolic volume index of 64 to 115 and 57 to 99 mL/m 2 , RV end-systolic volume index of 23 to 52 and 18 to 42 mL/m 2 , and RV mass index of 14 to 29 and 13 to 25 g/m 2 . CONCLUSIONS: Our Bayesian hierarchical meta-analysis provides normative reference values for CMR parameters of LV and RV size, systolic function, and mass, encompassing both tracing techniques across a diverse multinational sample of healthy men and women.
- 16 April 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (5) , 2376-2388
Magnetic resonance multitasking for multidimensional assessment of cardiovascular system: Development and feasibility study on the thoracic aorta
Purpose: To develop an MR multitasking‐based multidimensional assessment of cardiovascular system (MT‐MACS) with electrocardiography‐free and navigator‐free data acquisition for a comprehensive evaluation of thoracic aortic diseases.Methods: The MT‐MACS technique adopts a low‐rank tensor image model with a cardiac time dimension for phase‐resolved cine imaging and a T2‐prepared inversion‐recovery dimension for multicontrast assessment. Twelve healthy subjects and 2 patients with thoracic aortic diseases were recruited for the study at 3 T, and both qualitative (image quality score) and quantitative (contrast‐to‐noise ratio between lumen and wall, lumen and wall area, and aortic strain index) analyses were performed in all healthy subjects. The overall image quality was scored based on a 4‐point scale: 3, excellent; 2, good; 1, fair; and 0, poor. Statistical analysis was used to test the measurement agreement between MT‐MACS and its corresponding 2D references.Results: The MT‐MACS images reconstructed from acquisitions as short as 6 minutes demonstrated good or excellent image quality for bright‐blood (2.58 ± 0.46), dark‐blood (2.58 ± 0.50), and gray‐blood (2.17 ± 0.53) contrast weightings, respectively. The contrast‐to‐noise ratios for the three weightings were 49.2 ± 12.8, 20.0 ± 5.8 and 2.8 ± 1.8, respectively. There were good agreements in the lumen and wall area (intraclass correlation coefficient = 0.993, P < .001 for lumen; intraclass correlation coefficient = 0.969, P < .001 for wall area) and strain (intraclass correlation coefficient = 0.947, P < .001) between MT‐MACS and conventional 2D sequences.Conclusion: The MT‐MACS technique provides high‐quality, multidimensional images for a comprehensive assessment of the thoracic aorta. Technical feasibility was demonstrated in healthy subjects and patients with thoracic aortic diseases. Further clinical validation is warranted.
- 16 April 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (5) , 2376-2388
Magnetic resonance multitasking for multidimensional assessment of cardiovascular system: Development and feasibility study on the thoracic aorta
Purpose: To develop an MR multitasking‐based multidimensional assessment of cardiovascular system (MT‐MACS) with electrocardiography‐free and navigator‐free data acquisition for a comprehensive evaluation of thoracic aortic diseases.Methods: The MT‐MACS technique adopts a low‐rank tensor image model with a cardiac time dimension for phase‐resolved cine imaging and a T2‐prepared inversion‐recovery dimension for multicontrast assessment. Twelve healthy subjects and 2 patients with thoracic aortic diseases were recruited for the study at 3 T, and both qualitative (image quality score) and quantitative (contrast‐to‐noise ratio between lumen and wall, lumen and wall area, and aortic strain index) analyses were performed in all healthy subjects. The overall image quality was scored based on a 4‐point scale: 3, excellent; 2, good; 1, fair; and 0, poor. Statistical analysis was used to test the measurement agreement between MT‐MACS and its corresponding 2D references.Results: The MT‐MACS images reconstructed from acquisitions as short as 6 minutes demonstrated good or excellent image quality for bright‐blood (2.58 ± 0.46), dark‐blood (2.58 ± 0.50), and gray‐blood (2.17 ± 0.53) contrast weightings, respectively. The contrast‐to‐noise ratios for the three weightings were 49.2 ± 12.8, 20.0 ± 5.8 and 2.8 ± 1.8, respectively. There were good agreements in the lumen and wall area (intraclass correlation coefficient = 0.993, P < .001 for lumen; intraclass correlation coefficient = 0.969, P < .001 for wall area) and strain (intraclass correlation coefficient = 0.947, P < .001) between MT‐MACS and conventional 2D sequences.Conclusion: The MT‐MACS technique provides high‐quality, multidimensional images for a comprehensive assessment of the thoracic aorta. Technical feasibility was demonstrated in healthy subjects and patients with thoracic aortic diseases. Further clinical validation is warranted.
- 10 October 2019
- Published by Springer Nature
- Vol. 11765, 495-504
Deep Learning Within a Priori Temporal Feature Spaces for Large-Scale Dynamic MR Image Reconstruction: Application to 5-D Cardiac MR Multitasking
High spatiotemporal resolution dynamic magnetic resonance imaging (MRI) is a powerful clinical tool for imaging moving structures as well as to reveal and quantify other physical and physiological dynamics. The low speed of MRI necessitates acceleration methods such as deep learning reconstruction from under-sampled data. However, the massive size of many dynamic MRI problems prevents deep learning networks from directly exploiting global temporal relationships. In this work, we show that by applying deep neural networks inside a priori calculated temporal feature spaces, we enable deep learning reconstruction with global temporal modeling even for image sequences with >40,000 frames. One proposed variation of our approach using dilated multi-level Densely Connected Network (mDCN) speeds up feature space coordinate calculation by 3000x compared to conventional iterative methods, from 20 min to 0.39 s. Thus, the combination of low-rank tensor and deep learning models not only makes large-scale dynamic MRI feasible but also practical for routine clinical application (This work was supported by NIH 1R01EB028146). Keywords Image reconstruction Low-Rank model Deep learning
- 10 October 2019
- Published by Springer Nature
- Vol. 11765, 495-504
Deep Learning Within a Priori Temporal Feature Spaces for Large-Scale Dynamic MR Image Reconstruction: Application to 5-D Cardiac MR Multitasking
High spatiotemporal resolution dynamic magnetic resonance imaging (MRI) is a powerful clinical tool for imaging moving structures as well as to reveal and quantify other physical and physiological dynamics. The low speed of MRI necessitates acceleration methods such as deep learning reconstruction from under-sampled data. However, the massive size of many dynamic MRI problems prevents deep learning networks from directly exploiting global temporal relationships. In this work, we show that by applying deep neural networks inside a priori calculated temporal feature spaces, we enable deep learning reconstruction with global temporal modeling even for image sequences with >40,000 frames. One proposed variation of our approach using dilated multi-level Densely Connected Network (mDCN) speeds up feature space coordinate calculation by 3000x compared to conventional iterative methods, from 20 min to 0.39 s. Thus, the combination of low-rank tensor and deep learning models not only makes large-scale dynamic MRI feasible but also practical for routine clinical application (This work was supported by NIH 1R01EB028146). Keywords Image reconstruction Low-Rank model Deep learning
- 19 November 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (4) , 2450-2463
Free‐breathing, non‐ECG, continuous myocardial T1 mapping with cardiovascular magnetic resonance multitasking
Purpose: To evaluate the accuracy and repeatability of a free‐breathing, non‐electrocardiogram (ECG), continuous myocardial T1 and extracellular volume (ECV) mapping technique adapted from the Multitasking framework.Methods: The Multitasking framework is adapted to quantify both myocardial native T1 and ECV with a free‐breathing, non‐ECG, continuous acquisition T1 mapping method. We acquire interleaved high–spatial resolution image data and high–temporal resolution auxiliary data following inversion‐recovery pulses at set intervals and perform low‐rank tensor imaging to reconstruct images at 344 inversion times, 20 cardiac phases, and 6 respiratory phases. The accuracy and repeatability of Multitasking T1 mapping in generating native T1 and ECV maps are compared with conventional techniques in a phantom, a simulation, 12 healthy subjects, and 10 acute myocardial infarction patients.Results: In phantoms, Multitasking T1 mapping correlated strongly with the gold‐standard spin‐echo inversion recovery (R2 = 0.99). A simulation study demonstrated that Multitasking T1 mapping has similar myocardial sharpness to the fully sampled ground truth. In vivo native T1 and ECV values from Multitasking T1 mapping agree well with conventional MOLLI values and show good repeatability for native T1 and ECV mapping for 60 seconds, 30 seconds, or 15 seconds of data. Multitasking native T1 and ECV in myocardial infarction patients correlate positively with values from MOLLI.Conclusion: Multitasking T1 mapping can quantify native T1 and ECV in the myocardium with free‐breathing, non‐ECG, continuous scans with good image quality and good repeatability in vivo in healthy subjects, and correlation with MOLLI T1 and ECV in acute myocardial infarction patients.
- 19 November 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (4) , 2450-2463
Free‐breathing, non‐ECG, continuous myocardial T1 mapping with cardiovascular magnetic resonance multitasking
Purpose: To evaluate the accuracy and repeatability of a free‐breathing, non‐electrocardiogram (ECG), continuous myocardial T1 and extracellular volume (ECV) mapping technique adapted from the Multitasking framework.Methods: The Multitasking framework is adapted to quantify both myocardial native T1 and ECV with a free‐breathing, non‐ECG, continuous acquisition T1 mapping method. We acquire interleaved high–spatial resolution image data and high–temporal resolution auxiliary data following inversion‐recovery pulses at set intervals and perform low‐rank tensor imaging to reconstruct images at 344 inversion times, 20 cardiac phases, and 6 respiratory phases. The accuracy and repeatability of Multitasking T1 mapping in generating native T1 and ECV maps are compared with conventional techniques in a phantom, a simulation, 12 healthy subjects, and 10 acute myocardial infarction patients.Results: In phantoms, Multitasking T1 mapping correlated strongly with the gold‐standard spin‐echo inversion recovery (R2 = 0.99). A simulation study demonstrated that Multitasking T1 mapping has similar myocardial sharpness to the fully sampled ground truth. In vivo native T1 and ECV values from Multitasking T1 mapping agree well with conventional MOLLI values and show good repeatability for native T1 and ECV mapping for 60 seconds, 30 seconds, or 15 seconds of data. Multitasking native T1 and ECV in myocardial infarction patients correlate positively with values from MOLLI.Conclusion: Multitasking T1 mapping can quantify native T1 and ECV in the myocardium with free‐breathing, non‐ECG, continuous scans with good image quality and good repeatability in vivo in healthy subjects, and correlation with MOLLI T1 and ECV in acute myocardial infarction patients.
- 30 May 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 80 (4) , 1352-1363
Chemical exchange saturation transfer fingerprinting for exchange rate quantification
Purpose: There is an increased interest to determine the exchange rate using CEST to provide pH information. However, current CEST quantification methods require lengthy scan times and do not address magnetization transfer effects. The purpose of this work was to apply the magnetic resonance fingerprinting (MRF) concept to CEST to achieve more efficient and accurate exchange rate quantification.Methods: The proposed CEST fingerprinting method used varying saturation powers and saturation times to create unique signal evolutions for different exchange rates. The acquired signal was matched to a predefined dictionary to determine the exchange rate. The magnetization transfer effects were also addressed in the framework of CEST fingerprinting: The simulated dictionary could predict the signal curves without magnetization transfer effects, and comparing the dictionary to the acquired signals allowed the correction of the magnetization transfer effects. The CEST fingerprinting method was compared with the conventional pulsed quantitative CEST method using omega plots in the creatine phantom study.Results: The CEST fingerprinting method has a significantly reduced scan time (10 minutes versus 50 minutes) while providing more accurate exchange rate quantification using literature values as the reference.Conclusion: In this study, we demonstrate that CEST fingerprinting is more efficient (5 times faster) compared with pulsed quantitative CEST. It is also shown that the results of the proposed CEST fingerprinting technique are much closer to the literature values than pulsed quantitative CEST at 3 T.
- 30 May 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 80 (4) , 1352-1363
Chemical exchange saturation transfer fingerprinting for exchange rate quantification
Purpose: There is an increased interest to determine the exchange rate using CEST to provide pH information. However, current CEST quantification methods require lengthy scan times and do not address magnetization transfer effects. The purpose of this work was to apply the magnetic resonance fingerprinting (MRF) concept to CEST to achieve more efficient and accurate exchange rate quantification.Methods: The proposed CEST fingerprinting method used varying saturation powers and saturation times to create unique signal evolutions for different exchange rates. The acquired signal was matched to a predefined dictionary to determine the exchange rate. The magnetization transfer effects were also addressed in the framework of CEST fingerprinting: The simulated dictionary could predict the signal curves without magnetization transfer effects, and comparing the dictionary to the acquired signals allowed the correction of the magnetization transfer effects. The CEST fingerprinting method was compared with the conventional pulsed quantitative CEST method using omega plots in the creatine phantom study.Results: The CEST fingerprinting method has a significantly reduced scan time (10 minutes versus 50 minutes) while providing more accurate exchange rate quantification using literature values as the reference.Conclusion: In this study, we demonstrate that CEST fingerprinting is more efficient (5 times faster) compared with pulsed quantitative CEST. It is also shown that the results of the proposed CEST fingerprinting technique are much closer to the literature values than pulsed quantitative CEST at 3 T.
- Top Cited Papers
- 9 April 2018
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 2 (4) , 215-226
Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging
Quantitative cardiovascular magnetic resonance (CMR) imaging can be used to characterize fibrosis, oedema, ischaemia, inflammation and other disease conditions. However, the need to reduce artefacts arising from body motion through a combination of electrocardiography (ECG) control, respiration control and contrast-weighting selection makes CMR exams lengthy. Here, we show that physiological motions and other dynamic processes can be conceptualized as multiple time dimensions that can be resolved via low-rank tensor imaging, allowing for motion-resolved quantitative imaging with up to four time dimensions. This continuous-acquisition approach, which we name CMR multitasking, captures—rather than avoids—motion, relaxation and other dynamics to efficiently perform quantitative CMR without the use of ECG triggering or breath holds. We demonstrate that CMR multitasking allows for T1 mapping, T1/T2 mapping and time-resolved T1 mapping of myocardial perfusion without ECG information and/or under free-breathing conditions. CMR multitasking may provide a foundation for the development of setup-free CMR imaging for the quantitative evaluation of cardiovascular health.
- 9 April 2018
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 2 (4) , 215-226
Top Cited PapersMagnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging
Quantitative cardiovascular magnetic resonance (CMR) imaging can be used to characterize fibrosis, oedema, ischaemia, inflammation and other disease conditions. However, the need to reduce artefacts arising from body motion through a combination of electrocardiography (ECG) control, respiration control and contrast-weighting selection makes CMR exams lengthy. Here, we show that physiological motions and other dynamic processes can be conceptualized as multiple time dimensions that can be resolved via low-rank tensor imaging, allowing for motion-resolved quantitative imaging with up to four time dimensions. This continuous-acquisition approach, which we name CMR multitasking, captures—rather than avoids—motion, relaxation and other dynamics to efficiently perform quantitative CMR without the use of ECG triggering or breath holds. We demonstrate that CMR multitasking allows for T1 mapping, T1/T2 mapping and time-resolved T1 mapping of myocardial perfusion without ECG information and/or under free-breathing conditions. CMR multitasking may provide a foundation for the development of setup-free CMR imaging for the quantitative evaluation of cardiovascular health.
- Open Access
- 1 December 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 19 (1) , 95-7
Optimized CEST cardiovascular magnetic resonance for assessment of metabolic activity in the heart
- 1 December 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 19 (1) , 95-7
Open AccessOptimized CEST cardiovascular magnetic resonance for assessment of metabolic activity in the heart
- 1 July 2015
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 28 (7) , 795-801
Guideline Adherence for Echocardiographic Follow-Up in Outpatients with at Least Moderate Valvular Disease
- 1 July 2015
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 28 (7) , 795-801
Guideline Adherence for Echocardiographic Follow-Up in Outpatients with at Least Moderate Valvular Disease
- Open Access
- 1 February 2015
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 17 (1) , P141
Native myocardial T1 is elevated in subjects with coronary microvascular dysfunction and no obstructive CAD
- 1 February 2015
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 17 (1) , P141
Open AccessNative myocardial T1 is elevated in subjects with coronary microvascular dysfunction and no obstructive CAD