Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gerald Hefferman has a total of 113 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Balloon angioplasty versus stent placement for the treatment of portal vein stenosis in children: a single center experience

    by Patrick Ghibes, Gerd Grözinger, Steffen Hartleif, Ekkehard Sturm, Gerald M. Hefferman, Silvio Nadalin, Ilias Tsiflikas, Jürgen F. Schäfer, Christoph Artzner

    Purpose To evaluate the safety and efficacy of percutaneous interventional treatment of portal vein stenosis in children. Material and methods A retrospective analysis of all interventional treatments for portal vein stenosis in pediatric patients at a single institution from 2010 to 2021 was conducted. Platelet count, spleen size and portal vein flow velocity were assessed during the follow-up period. Primary and primary assisted patency time were determined. Results A total of ten children (median age 28.5 months, interquartile range (IQR): 2.75–52.5 months) with portal vein stenosis after Mesorex-Shunt (n = 4), liver transplantation (n = 3) and other etiologies (n = 3) underwent 15 interventional procedures. There were five reinterventions and one discontinued intervention. The technical success rate was 93.3% (14/15) and clinical success of treated patients was 100% (14/14). Median follow-up was 18 months (IQR: 13.5–81 months). The median primary patency time for stent placement was 70 months (IQR: 13.5–127.25 months). For balloon angioplasty, the median primary patency time was 9 months (IQR 7.25–11.5 months), while the median assisted primary patency time was 14 months (IQR: 12 to 15 months). Platelet count, spleen size and portal vein flow velocity reliably corresponded to recurrence of portal vein stenosis in asymptomatic patients during follow-up. Conclusion Interventional treatment is a safe and efficient method to treat portal vein stenosis with long patency times, regardless of etiology. Primary stent placement shows a higher primary patency time than balloon angioplasty. Implementation of stent placement as the primary interventional method may improve patency times and reduce the need for repeat reinterventions in pediatric patients.


  • Lack of correlation between hip osteoarthritis and anatomical spinopelvic parameters obtained in supine position on MRI

    by Elke Maurer, Roberto Lorbeer, Gerald Hefferman, Christopher L. Schlett, Annette Peters, Susanne Rospleszcz, Lena S. Kiefer, Konstantin Nikolaou, Fabian Bamberg, Sven S. Walter


  • Safety and Efficacy of Rotational Thrombectomy for Treatment of Arterial Occlusions of the Lower Extremities: A Large Single-Center Retrospective Study

    by Christoph Artzner, Isabelle Martin, Gerald Hefferman, Kerstin Artzner, Mario Lescan, Rick de Graaf, Gerd Grözinger

    Purpose To evaluate the safety and efficacy of rotational thrombectomy (RT) in a large single-center real-world cohort for total vascular occlusions of the lower extremity. Materials and Methods The clinical records and images of all patients between 2010 and 2020 treated via RT (Rotarex, BD) were assessed. Patient demographics, clinical data, procedural characteristics, and outcome parameters were documented. In total, 397 procedures in 293 patients were included (mean age 69.8 ± 12.0 years; 64.8 % male). Occlusions were acute (47.5 %), subacute and acute-on-chronic (22.2 %), and chronic (30.3 %). The target lesions were the iliac artery (7.1 %), iliac/femoropopliteal (5.0 %), femoropopliteal (59.4 %), femoropopliteal/below-the-knee (27.0 %), below-the-knee (1.5 %), and after bypass surgery (14.9 %). Lesion length was > 20 cm in 61.5 % of cases. Results Clinically successful revascularization was achieved in 90.4 % of cases. Additional thrombolysis was necessary for 32.0 % of procedures. The arithmetic mean ankle-brachial index increased from 0.33 ± 0.29 to 0.81 ± 0.25 (p < 0.0001). Bypass grafts were less likely to be fully treatable and required additional lysis (p < 0.001). The overall primary patency (no clinically driven target lesion revascularization) was 93.2 %, 88.8 %, 79.1 %, and 72.4 % at 1, 3, 6, and 12 months, respectively. Adverse events occurred in 46.1 % of cases, of which peripheral embolization (22.4 %) was most frequent, requiring interventional treatment in 67.4 % of cases. RT was directly associated with 7.1 % (n = 28) of complications, which consisted of perforations 2.8 %, arteriovenous fistula 1.3 %, and dissections 2.0 %. Conclusion Rotational thrombectomy is a safe and efficient method for the treatment of occlusions of the arterial circulation of the lower extremity with bypass occlusions having a higher propensity for residual thrombi requiring further lysis therapy. Key Points: Citation Format


  • Open Access

    Assessing the Accuracy of an Artificial Intelligence-Based Segmentation Algorithm for the Thoracic Aorta in Computed Tomography Applications

    by Christoph Artzner, Malte N. Bongers, Rainer Kärgel, Sebastian Faby, Gerald Hefferman, Judith Herrmann, Svenja L. Nopper, Regine M. Perl, Sven S. Walter

    The aim was to evaluate the accuracy of a prototypical artificial intelligence-based algorithm for automated segmentation and diameter measurement of the thoracic aorta (TA) using CT. One hundred twenty-two patients who underwent dual-source CT were retrospectively included. Ninety-three of these patients had been administered intravenous iodinated contrast. Images were evaluated using the prototypical algorithm, which segments the TA and determines the corresponding diameters at predefined anatomical locations based on the American Heart Association guidelines. The reference standard was established by two radiologists individually in a blinded, randomized fashion. Equivalency was tested and inter-reader agreement was assessed using intra-class correlation (ICC). In total, 99.2% of the parameters measured by the prototype were assessable. In nine patients, the prototype failed to determine one diameter along the vessel. Measurements along the TA did not differ between the algorithm and readers (p > 0.05), establishing equivalence. Inter-reader agreement between the algorithm and readers (ICC ≥ 0.961; 95% CI: 0.940–0.974), and between the readers was excellent (ICC ≥ 0.879; 95% CI: 0.818–0.92). The evaluated prototypical AI-based algorithm accurately measured TA diameters at each region of interest independent of the use of either contrast utilization or pathology. This indicates that the prototypical algorithm has substantial potential as a valuable tool in the rapid clinical evaluation of aortic pathology.


  • Compact multifunction digital OFDR system without using an auxiliary interferometer

    by Zheyi Yao, Thomas Mauldin, Zhenyu Xu, Gerald Hefferman, Tao Wei

    This paper describes an integrated, accurate, and inexpensive semiconductor laser -based optical frequency domain reflectometry (OFDR) system design. The system utilizes the fiber under test for both sensing and frequency sweep linearization functions, allowing the system to mitigate and compensate for phase errors without the need for an auxiliary interferometer, as is the case for traditional OFDR systems. Benefiting from the unique and embedded design, this system reaches the minimal OFDR system with only one optical interferometer and its corresponding optic-electric components without sacrificing accuracy. In addition, conventional design requires an external auxiliary interferometer, which may experience different noises from the main measuring interferometer, deteriorating the overall performance. Experimental results demonstrate the enhanced performance of the compact design as compared with the former methods, as well as the reduced complexity and improved cost-effectiveness.


  • Open Access

    Correlation between thoracolumbar disc degeneration and anatomical spinopelvic parameters in supine position on MRI

    by Sven S. Walter, Roberto Lorbeer, Gerald Hefferman, Christopher L. Schlett, Anette Peters, Susanne Rospleszcz, Konstantin Nikolaou, Fabian Bamberg, Mike Notohamiprodjo, Elke Maurer

    Objective: This study aims to investigate the correlation between spinopelvic parameters in supine position (pelvic incidence (PI), sacral slope (SS), pelvic tilt (PT), lumbar lordosis (LL)), disc degeneration and herniation of the thoracolumbar spine, as well as cardiovascular risk factors and back pain in a southern German cohort from the general population. Methods: This study is a cross-sectional, case–control study drawn from a prospective cohort of the “Cooperative Health Research in the Region of Augsburg/Kooperative Gesundheitsforschung in der Region Augsburg” study (KORA). In total, 374 participants (mean age 56.4 ± 9.2 years; 57.8% male) from the whole-body MRI cohort (FF4) were included. All participants underwent a standardized whole-body MRI on which disc degeneration of the thoracic and lumbar spine was evaluated using a sequence adapted Pfirrmann score. PI, PT, SS and LL were measured according to the description in the literature, using sagittal imaging. Furthermore, disc bulging and protrusion were assessed. Correlations were estimated by logistic regression models providing odds ratios. Results: Mean PI was 54.0° ± 11.1°, PT 13.0° ± 5.8°, SS 40.2° ± 8.8° and LL 36.2° ± 9.6°. SS was greater in men (p<0.05) and lumbar lordosis in women (p<0.001). PT increased by 0.09° per age-year with rising age. Age was not associated with PI, SS and LL. Neither BMI, hypertension, cholesterol, lipid levels, nor physical activity were associated with PI, PT, SS or LL. Diabetes mellitus negatively correlated with SS (β = -4.19; 95%CI -7.31–1.06, p<0.01). Smaller spinopelvic parameters (PI, SS and LL) where significantly (p<0.05) correlated with an increased frequency of disc bulging, as well as a local clustering in the lumbar, but not the thoracic spine. Conclusion: In conclusion, spinopelvic parameters, measured in supine position, are significantly correlated with disc bulging alone; there is no significant correlation between supine spinopelvic parameters and disc degeneration, back pain or cardiovascular risk factors.


  • Association between cardiovascular risk factors and degenerative disc disease of the thoracolumbar spine in the general population: results from the KORA MRI Study

    by Elke Maurer, Christian Klinger, Roberto Lorbeer, Gerald Hefferman, Christopher L Schlett, Annette Peters, Konstantin Nikolaou, Fabian Bamberg, Mike Notohamiprodjo, Sven S Walter

    Little is known about the associations between cardiovascular risk factors (CRF) and disc degeneration (DD). To evaluate the potential association between CRFs and intervertebral DD in a population-based sample. A total of 400 participants from the community-based KORA-study were assessed in terms of CRFs, specifically obesity, hypertension, diabetes, elevated LDL-c, low HDL-c, elevated triglycerides, smoking status, and alcohol consumption. The patients additionally underwent whole-body magnetic resonance imaging (MRI) using T2-weighted single-shot fast-spin-echo and T1 dual-echo gradient-echo Dixon pulse sequences. Thoracic and lumbar DD were assessed using the Pfirrmann score and for the presence of disc bulging/protrusion. Cross-sectional associations between CRFs and MR-based Pfirrmann score were then analyzed. A total of 385 individuals (58.2% men; mean age 56.3 ± 9.2 years) were included. Prevalence of DD was 76.4%. Older age (β = 0.18; 95% CI 0.12–0.25; P < 0.001) and higher body mass index (BMI) (β = 0.19; 95% CI 0.06–0.30; P = 0.003) were significantly associated with DD of the thoracolumbar spine. Diabetes was significantly associated with DD at T7/8 (P = 0.029) and L3/4 (P = 0.017). Hypertension correlated significantly with DD in univariate analysis, but the association did not persist using multivariate analysis (β = 0.53; 95% CI –0.74 to 1.81; P = 0.41). None of the other CRFs (P ≥ 0.11) were associated with advanced DD. Disc bulging was independently associated with hypertension (β = 0.47; 95% CI 0.27–0.81; P = 0.01). A significant independent association exists between age, BMI, and intervertebral DD. In contrast, there is no significant association between cardiovascular risk factors and DD. Providing strong evidence that the pathologic process undergirding DD is mechanical, rather than microvascular, in nature.


  • Effects of multiphase versus single-phase CT angiography for the detection of distal cerebral vessel occlusion

    by Gerald M. Hefferman, Grayson L. Baird, David W. Swenson, Robert C. Ward, Mahesh V. Jayaraman, Shawna Cutting, Gaurav Jindal

    Purpose The goal of this study was to determine whether the benefits of multiphase CTA (mCTA) over single-phase CTA (sCTA) for the detection of proximal cerebrovascular occlusions similarly extend to the distal cerebral vasculature. Methods Four attending radiologists, two neuroradiologists and two emergency radiologists, contributed as readers to this retrospective study. For each reader, two sessions were conducted, one using sCTA and one using mCTA. During each session, the reader interpreted the studies of 104 patients who underwent imaging for suspicion of acute ischemic stroke, resulting in a total of 832 interpretations. Changes in diagnostic accuracy, time to render final decision, and reported levels of reader confidence were quantitatively assessed. Further analysis comparing the effects for neuroradiologists versus emergency radiologists was additionally conducted. Results Using mCTA resulted in a significant 5.0% absolute increase in sensitivity (91.6% vs. 96.6%, p = .004) and an insignificant increase in specificity (99.5% vs. 99.7%, p = .39). A significant reduction in reading time (66.7 s vs. 59.6 s, p = .001) and an increase in diagnostic confidence (2.26 vs. 2.58, p < .001) were observed. Using sCTA, higher sensitivity was achieved by neuroradiologists than emergency radiologists (96.0% vs. 86.9%, p = .002); using mCTA resulted in an absolute increase in sensitivity of 0.9% (97.4%, p = .44) for neuroradiologists and 9.6% (96.5%, p < .001) for emergency radiologists, eliminating significant differences between the groups (p = 0.57). Conclusion The use of mCTA results in increased sensitivity and negative predictive value, decreased reading time, increased diagnostic confidence, and the elimination of differences in accuracy between neuroradiologists and emergency radiologists.


  • A High-Performance, Reconfigurable, Fully Integrated Time-Domain Reflectometry Architecture Using Digital I/Os

    by Zhenyu Xu, Thomas Mauldin, Zheyi Yao, Gerald Hefferman, Tao Wei

    Time-domain reflectometry (TDR) is an established means of measuring impedance inhomogeneity of a variety of waveguides, providing critical data necessary to characterize and optimize the performance of high-bandwidth computational and communication systems. However, TDR systems with both the high spatial resolution (sub-cm) and voltage resolution (sub-μV) required to evaluate high-performance waveguides are physically large and often cost-prohibitive, severely limiting their utility as testing platforms and greatly limiting their use in characterizing and trouble-shooting fielded hardware. Consequently, there exists a growing technical need for an electronically simple, portable, and low-cost TDR technology. The receiver of a TDR system plays a key role in recording reflection waveforms; thus, such a receiver must have high analog bandwidth, high sampling rate, and high-voltage resolution. However, these requirements are difficult to meet using low-cost analog-to-digital converters (ADCs). This article describes a new TDR architecture, namely, jitter-based APC (JAPC), which obviates the need for external components based on an alternative concept, analog-to-probability conversion (APC) that was recently proposed. These results demonstrate that a fully reconfigurable and highly integrated TDR (iTDR) can be implemented on a field-programmable gate array (FPGA) chip without using any external circuit components. Empirical evaluation of the system was conducted using an HDMI cable as the device under test (DUT), and the resulting impedance inhomogeneity pattern (IIP) of the DUT was extracted with spatial and voltage resolutions of 5 cm and 80 μV, respectively. These results demonstrate the feasibility of using the prototypical JAPC-based iTDR for real-world waveguide characterization applications.


  • An Integrated OFDR System Using Combined Swept-Laser Linearization and Phase Error Compensation

    by Zheyi Yao, Thomas Mauldin, Zhenyu Xu, Gerald Hefferman, Tao Wei

    This paper describes a flexible, compact, semiconductor laser (SCL)-based optical frequency-domain reflectometry (OFDR) design, incorporating swept-laser linearization functions (both passive and active), in-situ phase error evaluation function, and phase error compensation function. At the core of the proposed design, a fiber-optic Mach-Zehnder interferometer (MZI) and its electronic digitization components (photodetector and zero-cross circuit) simultaneously perform all abovementioned functions. Benefitting from the unique digital design, this system combines all functions in a compact fashion without increasing complexity and overhead. Experimental results demonstrate enhanced accuracy using the integrated design as compared to prior methods, as well as improved cost-effectiveness, reduced complexity, and optimized form factor.