İÖİbrahim Ulaş Özturan

İbrahim Ulaş Özturan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


İbrahim Ulaş Özturan has a total of 184 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    AI-Assisted Self-Directed Versus Instructor-Guided Simulation Training for Videolaryngoscopy Intubation: A Mixed Methods Randomized Study (Preprint)

    by Cansu Alyeşil Özturan, Erdal Karataş, Çağrıhan Ceylan, Ayşe Nur Sezer, Pınar Daylan, Dilek Kitapçıoğlu, İbrahim Ulaş Özturan

    BACKGROUND Videolaryngoscopy (VL) is increasingly used for emergency intubation, and simulation-based training (SBT) is an effective approach to training the skill. SBT typically requires an instructor for real-time feedback, which limits scalability in settings where faculty time is scarce. Self-directed learning supported by artificial intelligence (AI) guidance modules built into VL devices could extend SBT to such settings, but has not been directly compared with instructor coaching within an SBT curriculum. OBJECTIVE We compared AI-assisted self-directed and instructor-guided SBT for VL intubation on time to the Minimum Passing Standard (MPS), immediate performance, one-week retention, and learner experience. METHODS This single-center mixed-methods randomized study enrolled 122 medical interns with no prior VL experience, who were randomized 1:1 to instructor-guided training or AI-assisted self-directed training using a VL device's on-screen guidance module. In both arms, participants practiced until they declared readiness, at which point feedback was discontinued and they performed two consecutive testing attempts; the MPS required first-pass success in under 60 seconds without critical errors. Time to MPS was the cumulative practice time from the first practice attempt to the readiness declaration. The 122 post-training interviews underwent reflexive thematic analysis. RESULTS All 122 participants met the MPS without reaching the practice cap. Time to MPS did not differ between arms (medians 194 vs 203 seconds; 95% CI for between-arm difference −37 to +45 seconds; P>.99). At short-term (one-week) retention (76% follow-up), first-pass success was numerically higher with instructor guidance (80.4% vs 68.1%; absolute difference +12.3%, 95% CI −5.2% to +29.9%; P=.24). Six themes emerged: in both arms the videolaryngoscope screen itself was the main teacher; feedback mostly confirmed rather than corrected what learners were doing; only the instructor arm named errors with their clinical consequences; AI-arm participants met recognition lag, false negatives, and conflicting cues and disengaged from the module; the instructor arm added encouragement and reassurance the AI did not; and in both arms confidence stayed bounded by the gap between manikin and patient. CONCLUSIONS AI-assisted and instructor-guided SBT produced similar time to MPS on a high-fidelity simulator. A nonsignificant short-term retention trend favored instructor guidance, which the interviews linked to the instructor's corrective feedback and reassurance — features the AI did not provide.

  • Open Access

    Effects of air pollution and meteorological factors on hematological exacerbation phenotypes in patients presenting to the emergency department with COPD exacerbation

    by Erdal Karataş, Nurettin Özgür Doğan, Sibel Balcı, İbrahim Ulaş Özturan, Elif Yaka, Serkan Yılmaz, Murat Pekdemir

    To evaluate the short-term effects and lagged temporal patterns of air pollutants and meteorological factors on hematological exacerbation phenotypes in patients presenting to the emergency department with chronic obstructive pulmonary disease (COPD) exacerbation. Patients who presented to a tertiary emergency department with COPD exacerbation between April 2022 and April 2023 were retrospectively reviewed. Exacerbations were classified as eosinophilic, neutrophilic, or mixed-type based on admission complete blood counts. Daily air pollutant concentrations (PM₁₀, PM₂.₅, SO₂, NO₂, CO, O₃) and meteorological parameters were obtained from official monitoring stations. Day-level associations between environmental variables and phenotype-specific daily exacerbation counts were analyzed using quasi-Poisson distributed lag non-linear models (DLNM) and a time-stratified case-crossover design (lag 0–3 days). Of all exacerbations (n = 354), 65.8% were neutrophilic, 20.3% mixed-type, and 13.8% eosinophilic. The neutrophilic phenotype was associated with the most severe clinical presentation. No significant environmental association was identified for the overall COPD exacerbation count. In the eosinophilic phenotype, same-day exposure to CO and SO₂ was associated with increased exacerbation risk (RR = 1.39, 95% CI: 1.06–1.82 and RR = 1.21, 95% CI: 1.03–1.43, respectively). In the mixed-type phenotype, higher humidity was positively associated with exacerbation counts, whereas lower wind speed was associated with decreased counts. In the neutrophilic phenotype, an inverse association with O₃ observed in the DLNM was not confirmed in the case-crossover analysis. COPD exacerbations do not appear homogeneous with respect to environmental triggers; the eosinophilic phenotype showed clearer associations with gaseous pollutants, whereas the mixed-type phenotype showed associations with meteorological conditions. The absence of associations in the overall population supports the value of phenotype-based environmental risk assessment. These findings may contribute to the development of phenotype-oriented environmental warning strategies in COPD management.

  • Teleguidance-Facilitated Airway Management in Prehospital Emergency Medical Services: A High-Fidelity Randomized Controlled Simulation Study

    by Ravza Çinar, İbrahim Ulaş Özturan, Pınar Daylan, Serap Arsal Yıldırım, Nurettin Özgür Doğan, Elif Yaka, Serkan Yılmaz, Murat Pekdemir


  • Underrecognized immune events in the emergency department among cancer patients on immune checkpoint inhibitors

    by Gamze Kıvrak Yılmaz, İbrahim Ulaş Özturan, Anıl Karakayalı, Nurettin Özgür Doğan, Elif Yaka, Serkan Yılmaz, Murat Pekdemir


  • Quality of Cardiopulmonary Resuscitation Depictions in Movies

    by Ibrahim Sarbay, Goksu Bozdereli Berikol, Ibrahim Ulas Ozturan, Ismail Sarbay

    Objective: Cardiac arrest is a leading cause of mortality and morbidity worldwide. While outcomes of in-hospital cardiac arrest have improved, it was not observed for out-of-hospital cardiac arrest cases. Bystander cardiopulmonary resuscitation (CPR) can increase survival rates. Improving CPR knowledge among the general public is the center of attention to increase bystander CPR rates and improve outcomes. CPR depictions in movies may have positive or negative effects on public knowledge about CPR. We aimed to analyze the CPR depictions in movies and evaluate their medical accuracy.Materials and Methods: This study included “Feature Films” released between 01/01/1990 and 01/01/2023 presented in the IMDb movie database using the search function with the following keywords: “Cardiac arrest”, “cardiopulmonary resuscitation” (CPR), “resuscitation” and “CPR”. A total of 113 movies with 125 CPR scenes were analyzed. Basic characteristics for each movie and scene were recorded. Compression Quality Score (CQS) was calculated for each scene. Four researchers analyzed each CPR scene for medical accuracy using checklists. If the CPR is performed on the scene without any errors the scene is evaluated as “Accurate”. All decisions were taken unanimously.Results: Victims were mostly male (70.4%), adults (78.4%), and suffered trauma (70.4%). The CPR performer was a bystander in 92 cases (73.6%). CPR was performed outdoors in 52 cases (41.6%). Only 28 scenes were interpreted as “medically accurate” (20.8%). Conclusion: In this study, we found that CPR scenes in movies often do not accurately reflect how to perform CPR and may hinder the public perception of CPR.

  • Open Access

    Comparison of dental force applied during endotracheal intubation with hyper-angulated and macintosh-type video laryngoscopy blades used by emergency medicine trainees: A randomized cross-over manikin study

    by Ali Rıza Karabacak, İbrahim Ulaş Özturan, Ömer Faruk Şefoğlu, Nurettin Özgür Doğan, Elif Yaka, Serkan Yılmaz, Murat Pekdemir

    OBJECTIVES: This study aimed to compare the effects of Macintosh-type and hyperangulated video laryngoscopy (VL) blades on dental force during endotracheal intubation (ETI) using Glidescope and McGrath VL devices. METHODS: In this randomized, crossover, manikin study conducted at a university emergency medicine (EM) program, 65 EM trainees included interns and residents performed 520 intubations using four different VL blades (GlideScope VL with Macintosh-type Mac T3 and hyperangular Lo Pro T3 blades and McGrath VL Macintosh-type MAC 4 and hyperangular McGrath X3 blades) in normal and difficult airway scenarios. The primary outcome of this study was the dental pressure (Newton) exerted during ETI. The secondary outcomes included c-spine motion (degree), intubation success (%), duration (seconds), successful glottic view (%), and intubator comfort (7-point Likert). RESULTS: Significant differences were observed in dental force (H(3) = 11.7, P = 0.008), c-spine motion (H(3) = 8.34, P = 0.039), duration (H(3) = 16.56, P = 0.001), and comfort (H(3) = 174.96, P < 0.001) across blade types. Glidescope LoPro T3 provided a significant lower dental force (adjusted P = 0.01), less c-spine motion (adjusted P = 0.031), and shorter intubation duration (adj P < 0.01) than the McGrath Mac 4. First attempt success and intubator comfort were significantly better with all Glidescope blades (z score of 3.7 and 4.7) than with McGrath blades (z score of-4.1 and-4.4). CONCLUSION: The Glidescope LoPro T3 blade demonstrated advantages in dental force, c-spine motion, and intubation duration compared with McGrath Mac 4. Overall, the Glidescope blades provided superior comfort and higher first attempt success rates.


  • Open Access

    Prognostic accuracy of qSOFA score, SIRS criteria, and EWSs for in-hospital mortality among adult patients presenting with suspected infection to the emergency department (PASSEM) Multicenter prospective external validation cohort study protocol

    by Abdullah M Algarni, Musa S Alfaifi, Ali A Al Bshabshe, Othman M Omair, Mohammed A Alsultan, Hasan M Alzahrani, Hadi E Alali, Abdullah A Alsabaani, Ali M Alqarni, Salah A Alghanem, et al.

    Background: Early identification of a patient with infection who may develop sepsis is of utmost importance. Unfortunately, this remains elusive because no single clinical measure or test can reflect complex pathophysiological changes in patients with sepsis. However, multiple clinical and laboratory parameters indicate impending sepsis and organ dysfunction. Screening tools using these parameters can help identify the condition, such as SIRS, quick SOFA (qSOFA), National Early Warning Score (NEWS), or Modified Early Warning Score (MEWS). We aim to externally validate qSOFA, SIRS, and NEWS/NEWS2/MEWS for in-hospital mortality among adult patients with suspected infection who presenting to the emergency department. Methods and analysis: PASSEM study is an international prospective external validation cohort study. For 9 months, each participating center will recruit consecutive adult patients who visited the emergency departments with suspected infection and are planned for hospitalization. We will collect patients’ demographics, vital signs measured in the triage, initial white blood cell count, and variables required to calculate Charlson Comorbidities Index; and follow patients for 90 days since their inclusion in the study. The primary outcome will be 30-days in-hospital mortality. The secondary outcome will be intensive care unit (ICU) admission, prolonged stay in the ICU (i.e., ≥72 hours), and 30- as well as 90-days all-cause mortality. The study started in December 2021 and planned to enroll 2851 patients to reach 200 in-hospital death. The sample size is adaptive and will be adjusted based on prespecified consecutive interim analyses. Discussion: PASSEM study will be the first international multicenter prospective cohort study that designated to externally validate qSOFA score, SIRS criteria, and EWSs for in-hospital mortality among adult patients with suspected infection presenting to the ED in the Middle East region. Study registration: The study is registered at ClinicalTrials.gov (NCT05172479).