Ilya Reviakine
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ilya Reviakine has a total of 132 co-authors. Here are the top co-authors by number of shared publications:
Alain Brisson
10 shared publications- Diethelm Johannsmann
Institute of Physical Chemistry Clausthal University of Technology Clausthal‐Zellerfeld Germany
9 shared publications Marcus Textor
ETH Zurich 1 Laboratory for Surface Science and Technology, Department of Materials Zurich, 8093, Switzerland
8 shared publicationsFernanda F. Rossetti
BioInterfaceGroup, Laboratory for Surface Science and Technology, Department of Materials, Swiss Federal Institute of Technology (ETH), CH-8093 Zürich, Switzerland
6 shared publicationsWilma Bergsma-Schutter
5 shared publications- Marta Gallego
CIC biomaGUNE, 20014 San Sebastian, Spain
4 shared publications
Latest Publications
- Open Access
- 12 March 2025
- Published by Wiley in Advanced Theory and Simulations
- Vol. 8 (7)
The Frequency‐Domain Lattice Boltzmann Method (FreqD‐LBM): A Versatile Tool to Predict the QCM Response Induced by Structured Samples
The quartz crystal microbalance with dissipation monitoring (QCM‐D) is routinely used to investigate structured samples. Here, a simulation technique is described, that predicts the shifts of frequency and half bandwidth, Δfn and ΔΓn, of a quartz resonator operating on different overtone orders, n, induced by structured samples in contact with the resonator surface in liquid. The technique, abbreviated as FreqD‐LBM, solves the Stokes equation in the frequency domain. The solution provides the complex amplitude of the area‐averaged tangential stress at the resonator surface, from which Δfn and ΔΓn are derived. Because the dynamical variables are complex amplitudes, the viscosity can be complex, as well. The technique naturally covers viscoelasticity. Limitations are linked to the grid resolution and to problems at large viscosity. Validation steps include viscoelastic films, rough surfaces, an oscillating cylinder in a viscous medium, and a free‐floating sphere above the resonator. Application examples are soft adsorbed particles, stiff adsorbed particles, and a large, immobile spherical cap above the resonator, which allows to study the high‐frequency properties of the material in the gap. FreqDLBM runs on an office PC and does not require expert knowledge of numerical techniques. It is accessible to an experimentalist.
- 12 March 2025
- Published by Wiley in Advanced Theory and Simulations
- Vol. 8 (7)
Open AccessThe Frequency‐Domain Lattice Boltzmann Method (FreqD‐LBM): A Versatile Tool to Predict the QCM Response Induced by Structured Samples
The quartz crystal microbalance with dissipation monitoring (QCM‐D) is routinely used to investigate structured samples. Here, a simulation technique is described, that predicts the shifts of frequency and half bandwidth, Δfn and ΔΓn, of a quartz resonator operating on different overtone orders, n, induced by structured samples in contact with the resonator surface in liquid. The technique, abbreviated as FreqD‐LBM, solves the Stokes equation in the frequency domain. The solution provides the complex amplitude of the area‐averaged tangential stress at the resonator surface, from which Δfn and ΔΓn are derived. Because the dynamical variables are complex amplitudes, the viscosity can be complex, as well. The technique naturally covers viscoelasticity. Limitations are linked to the grid resolution and to problems at large viscosity. Validation steps include viscoelastic films, rough surfaces, an oscillating cylinder in a viscous medium, and a free‐floating sphere above the resonator. Application examples are soft adsorbed particles, stiff adsorbed particles, and a large, immobile spherical cap above the resonator, which allows to study the high‐frequency properties of the material in the gap. FreqDLBM runs on an office PC and does not require expert knowledge of numerical techniques. It is accessible to an experimentalist.
- 5 September 2024
- Published by Springer Nature in Nature Reviews Methods Primers
- Vol. 4 (1) , 1-21
Quartz crystal microbalance with dissipation monitoring for studying soft matter at interfaces
- 5 September 2024
- Published by Springer Nature in Nature Reviews Methods Primers
- Vol. 4 (1) , 1-21
Quartz crystal microbalance with dissipation monitoring for studying soft matter at interfaces
- Open Access
- 1 January 2024
- Published by American Vacuum Society in Biointerphases
- Vol. 19 (1)
Quartz crystal microbalance in soft and biological interfaces
Applications of quartz crystal microbalance with dissipation to studying soft and biological interfaces are reviewed. The focus is primarily on data analysis through viscoelastic modeling and a model-free approach focusing on the acoustic ratio. Current challenges and future research and development directions are discussed.
- 1 January 2024
- Published by American Vacuum Society in Biointerphases
- Vol. 19 (1)
Open AccessQuartz crystal microbalance in soft and biological interfaces
Applications of quartz crystal microbalance with dissipation to studying soft and biological interfaces are reviewed. The focus is primarily on data analysis through viscoelastic modeling and a model-free approach focusing on the acoustic ratio. Current challenges and future research and development directions are discussed.
- Open Access
Effect of Noise on Determining Ultrathin-Film Parameters from QCM-D Data with the Viscoelastic Model
Quartz crystal microbalance with dissipation monitoring (QCM-D) is a well-established technique for studying soft films. It can provide gravimetric as well as nongravimetric information about a film, such as its thickness and mechanical properties. The interpretation of sets of overtone-normalized frequency shifts, ∆f/n, and overtone-normalized shifts in half-bandwidth, ΔΓ/n, provided by QCM-D relies on a model that, in general, contains five independent parameters that are needed to describe film thickness and frequency-dependent viscoelastic properties. Here, we examine how noise inherent in experimental data affects the determination of these parameters. There are certain conditions where noise prevents the reliable determination of film thickness and the loss tangent. On the other hand, we show that there are conditions where it is possible to determine all five parameters. We relate these conditions to the mathematical properties of the model in terms of simple conceptual diagrams that can help users understand the model’s behavior. Finally, we present new open source software for QCM-D data analysis written in Python, PyQTM.
Open AccessEffect of Noise on Determining Ultrathin-Film Parameters from QCM-D Data with the Viscoelastic Model
Quartz crystal microbalance with dissipation monitoring (QCM-D) is a well-established technique for studying soft films. It can provide gravimetric as well as nongravimetric information about a film, such as its thickness and mechanical properties. The interpretation of sets of overtone-normalized frequency shifts, ∆f/n, and overtone-normalized shifts in half-bandwidth, ΔΓ/n, provided by QCM-D relies on a model that, in general, contains five independent parameters that are needed to describe film thickness and frequency-dependent viscoelastic properties. Here, we examine how noise inherent in experimental data affects the determination of these parameters. There are certain conditions where noise prevents the reliable determination of film thickness and the loss tangent. On the other hand, we show that there are conditions where it is possible to determine all five parameters. We relate these conditions to the mathematical properties of the model in terms of simple conceptual diagrams that can help users understand the model’s behavior. Finally, we present new open source software for QCM-D data analysis written in Python, PyQTM.
- 4 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (5) , 6643-6651
A Fast Method for Monitoring the Shifts in Resonance Frequency and Dissipation of the QCM Sensors of a Monolithic Array in Biosensing Applications
Improvement of data acquisition rate remains as an important challenge in applications with Quartz Crystal Microbalance (QCM) technology where high throughput is required. To address this challenge, we developed a fast method capable of measuring the response of a large number of sensors and/or overtones, with a high time resolution. Our method, which can be implemented in a low-cost readout electronic circuit, is based on the estimation of Δfr (frequency shift) and ΔD (dissipation shift) from measurements of the sensor response obtained at a single driving frequency. By replacing slow fitting procedures with a direct calculation, the time resolution is only limited by the physical characteristics of the sensor (resonance frequency and quality factor), but not by the method itself. Capabilities of the method are demonstrated by monitoring multiple overtones with a single 5 MHz sensor and a Monolithic QCM array comprising 24 50MHz-sensors. Accuracy of the method is validated and compared with the state-of-the-art, as well as with a reference method based on impedance analysis.
- 4 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (5) , 6643-6651
A Fast Method for Monitoring the Shifts in Resonance Frequency and Dissipation of the QCM Sensors of a Monolithic Array in Biosensing Applications
Improvement of data acquisition rate remains as an important challenge in applications with Quartz Crystal Microbalance (QCM) technology where high throughput is required. To address this challenge, we developed a fast method capable of measuring the response of a large number of sensors and/or overtones, with a high time resolution. Our method, which can be implemented in a low-cost readout electronic circuit, is based on the estimation of Δfr (frequency shift) and ΔD (dissipation shift) from measurements of the sensor response obtained at a single driving frequency. By replacing slow fitting procedures with a direct calculation, the time resolution is only limited by the physical characteristics of the sensor (resonance frequency and quality factor), but not by the method itself. Capabilities of the method are demonstrated by monitoring multiple overtones with a single 5 MHz sensor and a Monolithic QCM array comprising 24 50MHz-sensors. Accuracy of the method is validated and compared with the state-of-the-art, as well as with a reference method based on impedance analysis.
- Open Access
- 1 November 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (11) , 115108
An ultrafast quartz crystal microbalance based on a frequency comb approach delivers sub-millisecond time resolution
Quartz crystal microbalance with dissipation monitoring (QCMD) is a simple and versatile sensing technique with applications in a wide variety of academic and industrial fields, most notably electrochemistry, biophysics, quality control, and environmental monitoring. QCMD is limited by a relatively poor time resolution, which is of the order of seconds with conventional instrument designs at the noise level usually required. In this work, we present a design of an ultrafast QCMD with submillisecond time resolution. It is based on a frequency comb approach applied to a high-fundamental-frequency (HFF) resonator through a multifrequency lock-in amplifier. The combination allows us to reach data acquisition rates >10 kHz. We illustrate the method using a toy model of a glass sphere dropped on the resonator surfaces, bare or coated with liposomes, in liquid. We discuss some interesting features of the results obtained with the dropped spheres, such as bending of the HFF resonators due to the impact, sphere bouncing (or the absence of it), and contact aging.
- 1 November 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (11) , 115108
Open AccessAn ultrafast quartz crystal microbalance based on a frequency comb approach delivers sub-millisecond time resolution
Quartz crystal microbalance with dissipation monitoring (QCMD) is a simple and versatile sensing technique with applications in a wide variety of academic and industrial fields, most notably electrochemistry, biophysics, quality control, and environmental monitoring. QCMD is limited by a relatively poor time resolution, which is of the order of seconds with conventional instrument designs at the noise level usually required. In this work, we present a design of an ultrafast QCMD with submillisecond time resolution. It is based on a frequency comb approach applied to a high-fundamental-frequency (HFF) resonator through a multifrequency lock-in amplifier. The combination allows us to reach data acquisition rates >10 kHz. We illustrate the method using a toy model of a glass sphere dropped on the resonator surfaces, bare or coated with liposomes, in liquid. We discuss some interesting features of the results obtained with the dropped spheres, such as bending of the HFF resonators due to the impact, sphere bouncing (or the absence of it), and contact aging.
- Open Access
- 1 October 2019
- Published by Walter de Gruyter GmbH in Chemistry International
- Vol. 41 (4) , 47-48
Blood-Biomaterial Interactions
Article Blood-Biomaterial Interactions was published on October 1, 2019 in the journal Chemistry International (volume 41, issue 4).
- 1 October 2019
- Published by Walter de Gruyter GmbH in Chemistry International
- Vol. 41 (4) , 47-48
Open AccessBlood-Biomaterial Interactions
Article Blood-Biomaterial Interactions was published on October 1, 2019 in the journal Chemistry International (volume 41, issue 4).
- 1 March 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 87, 55-60
BloodSurf 2017: News from the blood-biomaterial frontier
- 1 March 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 87, 55-60
BloodSurf 2017: News from the blood-biomaterial frontier
- 1 May 2018
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - Biomembranes
- Vol. 1860 (5) , 1099-1104
When a transmembrane channel isn't, or how biophysics and biochemistry (mis)communicate
- 1 May 2018
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - Biomembranes
- Vol. 1860 (5) , 1099-1104
When a transmembrane channel isn't, or how biophysics and biochemistry (mis)communicate
- 1 January 2017
- Published by Elsevier in Blood Reviews
- Vol. 31 (1) , 11-21
Stirred, shaken, or stagnant: What goes on at the blood–biomaterial interface
- 1 January 2017
- Published by Elsevier in Blood Reviews
- Vol. 31 (1) , 11-21
Stirred, shaken, or stagnant: What goes on at the blood–biomaterial interface