MPMarie‐Agnès Popot

Marie‐Agnès Popot

*This is an algorithmically generated author record based on publicly available information.

Marie‐Agnès Popot has a total of 97 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Doping Control Analysis of Total Carbon Dioxide (TCO2) in Equine Plasma by Headspace Gas Chromatography–Mass Spectrometry (HS‐GC/MS)

    by Karen Y. Kwok, Wai Him Kwok, Terence S. M. Wan, Lydia Brooks, Marie‐Agnes Popot, Murielle Jaubert, Ludovic Bailly‐Chouriberry, Brendan T. Heffron, Chak Kwen Choo, Juanita Tso, et al.

    The use of alkalinising agents prior to racing for manipulating performance in the horse has been identified since the 1990s. To mitigate the risk, an international threshold for available carbon dioxide in equine plasma based on analyses using the Beckman Synchron EL‐ISE analyser was adopted in 1994 by the International Federation of Horseracing Authorities (IFHA) and revised from 37 to 36 mM in 2004. In 2009, the technical support for the above instrument was discontinued by its manufacturer. Based on the same measurement principle (i.e., ion selective electrode), the Beckman DxC600 analyser was selected as an alternative and validated against the protocol developed by the Association of Official Racing Chemists (AORC). Recently, the DxC600 analyser is also no longer supported by Beckman. Various alternative methods for measuring total carbon dioxide (TCO2) in plasma have been explored. Among these, a headspace gas chromatography–mass spectrometry (HS‐GC/MS) method was first reported by the Analytical Forensic Testing Laboratory (AFTL) in 2017. Methods based on the same measurement principle were later developed by different horseracing laboratories. With the objective of cross‐validating the new HS‐GC/MS methods and to establish an absolute (rather than instrument‐dependent or empirical) threshold, an international research collaboration was initiated among different racing laboratories. This paper describes the results of cross‐validation studies conducted in November 2019 and December 2022 using horse administration samples from Canada and France, respectively, the determination of a threshold based on population data, and some technical insights on the HS‐GC/MS methods.

  • New Transcriptomic Biomarkers for Detection of the Recombinant Human Erythropoietin (rHuEPO) MirCERA in Horses

    by Benoit Loup, François André, Nicolas Leuenberger, Alexandre Marchand, Agnès Barnabé, Vivian Delcourt, Patrice Garcia, Marie‐Agnès Popot, Ludovic Bailly‐Chouriberry

    Detection and monitoring of biomarkers related to doping is particularly suitable for the development of analytical strategies dedicated to indirect detection of banned substances. Previous studies in horses have already allowed the investigation of transcriptomic biomarkers in equine blood associated with reGH and rHuEPO administrations. Our most recent developments continue to focus on the discovery and monitoring of transcriptomic biomarkers for the control of ESAs, and a collaborative study with WADA‐accredited doping control laboratories has recently been initiated to conduct a pilot study. In humans, three mRNAs (ALAS2, CA1, and SLC4A1) were previously observed to be differentially expressed after blood doping and were associated with immature red blood cells, the so‐called circulating reticulocytes. In horses, circulating reticulocytes are rarely observed even after rHuEPO administration. With the improved primers that detect the equine orthologues of the human mRNAs from the ALAS2, CA1, and SLC4A1 genes, we can now report the first evidence of the detection of the three biomarkers in equine blood. In addition, an upregulation of the mRNA levels of the three genes was observed after analysis of blood samples collected from MirCERA‐treated animals, with kinetics similar to those previously documented in humans. Our data suggest that ALAS2 and CA1 are promising indirect biomarkers for the detection of recombinant EPO abuse in horses, as observed in humans.


  • Equine Doping Controls of Thymosin β4: A Population Study and Strategy for Misuse Detection

    by Vivian Delcourt, Patrice Garcia, Benjamin Chabot, Nina Aber, Mylène Pescher, Marie Cacault, Priscilla Scholtes, Benoit Loup, Agnès Barnabé, Marie‐Agnès Popot, et al.

    Thymosin 4 (TB4) is a ubiquitous, highly conserved and abundant peptide among mammals with a critical role in cytoskeleton organization. In spite of its yet non‐authorized use as a medicine and being forbidden by the IFHA, the FEI, and the WADA, intelligence and doping control laboratories reported numerous products available online claiming to contain a synthetic acetylated fragment of TB4 or TB4 itself, promoted as a growth factor with regenerative properties. In this article, the first estimation of the endogenous TB4 concentration in racing horses’ blood samples was performed through a population study. We reveal that this concentration does not significantly depend on gender, age, nor horse breed. We highlight that the TB4 concentration increases significantly and rapidly in plasma stored at 4°C when not separated from blood cells due to cell lysis. Finally, we also demonstrate that the detection of a non‐natural synthesis impurity is possible in equine plasma after a single dose administration of a TB4 containing product to a horse.


  • High‐Throughput Equine Doping Controls on a Trapped Ion Mobility Quadrupole‐Time‐of‐Flight Mass Spectrometer: Technical Considerations of dia/slice/prmPASEF Applied to the Long‐Term Detection of Monoclonal Antibodies

    by Vivian Delcourt, Justine Pinetre, Benjamin Chabot, Agnès Barnabé, Marie Cacault, Benoit Loup, François Becher, François Fenaille, Marie‐Agnès Popot, Patrice Garcia, et al.

    Data‐independent acquisition (DIA) methods employing a scanning quadrupole were recently described across multiple platforms. These strategies display remarkable performances in untargeted proteomics studies thanks to rapid duty cycles, leading to ultrashort liquid chromatography gradients while maintaining enough data points per peaks when coupled to fast‐scanning mass analyzer. In this article, we perform the evaluation of three data acquisition strategies named diaPASEF,slicePASEF, and prmPASEF on a trapped ion mobility spectrometry quadrupole‐time‐of‐flight (TIMS‐Q‐TOF) mass spectrometer for high‐throughput doping control screening analyses. We report that slicePASEF outperforms diaPASEF and is almost as sensitive as prmPASEF in detecting humanized monoclonal antibodies for several weeks in equine plasma after administration. We observed that diaPASEF is still providing the best performances in untargeted proteomics studies employing high amounts of input materials, which is linked with the high complexity of slicePASEF data and current processing algorithms.


  • Bayesian Individual Limits for IGF‐1 Monitoring in Equine Plasma: Implementation in the Equine Biological Passport

    by Agnès Barnabé, Benoit Loup, Adam Cawley, Vivian Delcourt, Patrice Garcia, Marie‐Agnès Popot, John Keledjian, Ludovic Bailly‐Chouriberry

    Despite the International Federation of Horseracing Authorities (IFHA) regulation associated with heavy sanctions, the abuse of prohibited substances must be identified and deterred throughout horses' athletic careers, such as the administration of recombinant growth hormone (rGH). GH is naturally produced in mammal organisms to stimulate growth. Thus, rGH administration can enhance the performance of horses by expanding some physical abilities. As measuring endogenous GH levels is complex, an indirect strategy is to monitor GH‐associated biomarkers in plasma as insulin‐like growth factor 1 (IGF‐1) levels. To prevent these misuses, the Equine Biological Passport (EBP) has been designed in France (GIE LCH) and Australia (ARFL‐Racing NSW) to profile specific biological and chemical parameters in selected racehorses. In this study, we investigated individual limits as a complementary tool to a single limit to supervise the stability of IGF‐1 profile over a racing season. The aim is to design custom limits based on the horse's history to detect any deviation below the single limit. The method was assessed using experimental data and then tested on EBP data from three thoroughbreds and three French trotters. Finally, individual limits have been added to the French EBP for IGF‐1 monitoring.


  • In vivo comparative study of hemp straw exposure and cannabidiol oil administration in horse urine

    by Stéphane Trevisiol, Marie‐Agnès Popot, Patrice Garcia, Sophie Boyer, Mylène Caroff, Laura Drif, Wafek Taleb, Sophie Tendon, Yves Moulard, Ludovic Bailly‐Chouriberry

    The non‐psychoactive cannabinoids cannabidiol (CBD) and cannabidiolic acid (CBDA) are available on the market in different forms, mostly for their anti‐inflammatory and potential analgesic properties. These substances are prohibited during equine competitions. CBD and CBDA are naturally present in hemp straw, commonly used as a bedding substitute for wheat straw. Unfortunately, horses can eat it, which therefore could lead to a possible risk of positive findings for CBD/CBDA in biological samples after doping control tests. The goals of this study were, first, to provide recommendations on the use of hemp straw before competition and, second, to assess if discrimination between hemp bedding exposure and CBD oil administration is possible. Several CBD equine in vivo studies have been conducted, including one on hemp straw used as bedding and one after administration of CBD oil by topical and sublingual routes. In hemp straw, CBDA was detected in higher quantities than CBD, and other cannabinoids have been observed. After hemp straw exposure, CBDA was also detected in higher quantities than CBD in all urine samples. It appeared that hemp straw should not be used as bedding for equine competition except if a delay of at least 48 h is respected. Regarding the CBD oil product analysis, CBD was the main compound detected. After administration, 7‐hydroxy CBD was identified in the urine. In conclusion, based on these data, we highlighted that it could be possible to discriminate the exposure of a horse to hemp straw from an administration of a CBD oil product thanks to the main presence of CBDA.


  • High‐throughput untargeted screening of biotherapeutic macromolecules in equine plasma by UHPLC‐HRMS/MS: Application to monoclonal antibodies and Fc‐fusion proteins for doping control

    by Justine Pinetre, Vivian Delcourt, François Becher, Patrice Garcia, Agnès Barnabé, Benoit Loup, Marie‐Agnès Popot, François Fenaille, Ludovic Bailly‐Chouriberry

    Many innovative biotherapeutics have been marketed in the last decade. Monoclonal antibodies (mAbs) and Fc‐fusion proteins (Fc‐proteins) have been developed for the treatment of diverse diseases (cancer, autoimmune diseases, and inflammatory disorders) and now represent an important part of targeted therapies. However, the ready availability of such biomolecules, sometimes characterized by their anabolic, anti‐inflammatory, or erythropoiesis‐stimulating properties, raises concerns about their potential misuse as performance enhancers for human and animal athletes. In equine doping control laboratories, a method has been reported to detect the administration of a specific human biotherapeutic in equine plasma; but no high‐throughput method has been described for the screening without any a priori knowledge of human or murine biotherapeutic. In this context, a new broad‐spectrum screening method involving UHPLC‐HRMS/MS has been developed for the untargeted analysis of murine or human mAbs and related macromolecules in equine plasma. This approach, consisting of a “pellet digestion” strategy performed in a 96‐well plate, demonstrates reliable performances at low concentrations (pmol/mL range) with high‐throughput capability (≈100 samples/day). Targeting species‐specific proteotypic peptides located within the constant parts of mAbs enables the “universal” detection of human biotherapeutics only by monitoring 10 peptides. As proof of principle, this strategy successfully detected different biotherapeutics in spiked plasma samples, and allowed, for the first time, the detection of a human mAb up to 10 days after a 0.12 mg/kg administration to a horse. This development will expand the analytical capabilities of horse doping control laboratories towards protein‐based biotherapeutics with adequate sensitivity, throughput, and cost‐effectiveness.


  • TB500/TB1000 and SGF1000: A scientific approach for a better understanding of misbranded and adulterated drugs

    by Vivian Delcourt, Patrice Garcia, Benjamin Chabot, Agnès Barnabé, Maëlle Bouscarel, Benoit Loup, Marie‐Agnès Popot, Ludovic Bailly‐Chouriberry

    Nowadays, numerous websites attempt to commercialize over the internet various products, regardless of the lack of approval by the EMA or the FDA either for human or veterinary use. These products are often produced after aborted drug development due to insufficient or deleterious biological effects, synthesized based on natural products, or only based on scientific literature. However, the administration of such products is dangerous, considering the lack of official control over the production of these substances and the absence of approval by health authorities. In this short communication, we provide an extensive analysis of three misbranded and adulterated products sold over the internet named TB500, TB1000, and SGF1000. We confirm that the content of TB500/TB1000 products is not systematically consistent with it's former descriptions, but also that SGF1000 is mainly composed of sheep extracellular matrix (ECM) and blood proteins, and the signal corresponding to the purported growth promoters is excessively diluted.


  • From a non‐targeted metabolomics approach to a targeted biomarkers strategy to highlight testosterone abuse in equine. Illustration of a methodological transfer between platforms and laboratories

    by Chloé Cloteau, Gaud Dervilly, Zied Kaabia, Florian Bagilet, Vivian Delcourt, Benoit Loup, Yann Guitton, Anne‐Lise Royer, Fabrice Monteau, Patrice Garcia, et al.

    In order to overcome the challenge associated with the screening of Anabolic‐Androgenic Steroids abuses in animal competitions, a non‐targeted liquid chromatography coupled to high resolution mass spectrometry based metabolomics approach was implemented on equine urine samples to highlight potential biomarkers associated with the administration of such compounds, using testosterone esters as model steroids. A statistical model relying on four potential biomarkers intensity could be defined to predict the status of the samples. With a routine application perspective, the monitoring of the highlighted potential biomarkers was first transferred into high‐throughput liquid chromatography‐selected reaction monitoring (LC‐SRM). The model's performances and robustness of the approach were preserved and providing a first demonstration of metabolomics‐based biomarkers integration within a targeted workflow using common benchtop MS instrumentation. In addition, with a view to the widespread implementation of such biomarker‐based tools, we have transferred the method to a second laboratory with similar instrumentation. This proof of concept allows the development and application of biomarker‐based strategies to meet current doping control needs.


  • LC‐HRMS/MS study of the prodrug ciclesonide and its active metabolite desisobutyryl‐ciclesonide in plasma after an inhalative administration to horses for doping control purposes

    by Stéphane Trevisiol, Yves Moulard, Zied Kaabia, Vivian Delcourt, Benoit Loup, Patrice Garcia, Sophie Boyer, Karine Dauriac, Guillaume Groseille, Sébastien Rouger, et al.

    Ciclesonide (CIC) is the first inhaled highly potent corticosteroid which does not cause any cortisol suppression. It has been developed for the treatment of asthma in human and more recently in equine. CIC is the active compound of Aservo® EquiHaler® (Boehringer Ingelheim Vetmedica GmbH), the pre-filled inhaler generating a medicated mist based on Soft MistTM technology. This prodrug is rapidly converted to desisobutyryl-ciclesonide (des-CIC), the main pharmacologically active compound. Due to its anti-inflammatory properties CIC is prohibited for use in horse competitions. To set up an appropriate control, the determination of detection times and screening limits are required. Therefore, a highly sensitive analytical method based on Supported Liquid Extraction (SLE) combined with Liquid Chromatography - High Resolution tandem Mass Spectrometry (LC-HRMS/MS) was developed to detect CIC and its active metabolite des-CIC in plasma. The lower limit of detection of CIC and des-CIC was approximately 1 pg/mL in plasma. After a pilot study conducted on a single horse at the recommended dose (8 actuations twice daily corresponding to 5.5 mg/day for the first five days, followed by 12 actuations once daily corresponding to 4.1 mg/day in the last five days), the same protocol was applied in the main study using six-horses. In all horses, CIC and des-CIC levels were less than 5 and 10 pg/mL, respectively, at 36 hours after the end of the administration. The outcome of this risk assessment study should be useful to draw any recommendations for horse competitions.