Charles Farbos de Luzan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Charles Farbos de Luzan has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Liran Oren
Department of Otolaryngology Head and Neck Surgery, University of Cincinnati, Cincinnati, OH 45267, USA
13 shared publications - Ephraim Gutmark
Department of Aerospace Engineering and Engineering Mechanics, University of Cincinnati, Cincinnati, OH 45267, USA
11 shared publications Ephraim Gutmark
Aerosp. Eng., Univ. of Cincinnati, Cincinnati, OH
9 shared publications- Jacob Michaud-Dorko
Department of Biomedical Engineering, University of Cincinnati 1 , Cincinnati, Ohio 45221
5 shared publications Liran Oren
Department of Otolaryngology-Head and Neck Surgery, University of Cincinnati College of Medicine, Cincinnati, OH
5 shared publicationsSid M. Khosla
Department of Otolaryngology‐Head and Neck Surgery University of Cincinnati Medical Center Cincinnati Ohio USA
5 shared publications
Latest Publications
- Open Access
- 1 May 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (5)
Phase-locked characterization of intraglottal flow separation vortices and medial surface motion during phonation
This study investigates vocal fold vibration by characterizing glottal geometry and aerodynamic properties at different coronal planes along the posterior to anterior axis in excised canine larynges. Multi-plane, phase locked two-dimensional (2D) particle image velocimetry was used to reconstruct the medial glottal wall geometry and intraglottal flow fields across equidistant coronal planes during phonation. The results reveal significant spatial variation in glottal shape and flow dynamics, with larger glottal openings and divergence angles observed in the mid-coronal and anterior planes compared to the posterior plane. Flow separation vortices (FSV) consistently formed along the medial glottal wall during the closing phase but varied in size and location depending on coronal position. In the mid-coronal and anterior regions, FSV formed closer to the inferior edge and produced stronger flow entrainment, higher circulation, and greater negative gauge pressures, leading to more pronounced flow skewing during closure. In contrast, FSV in the posterior region formed near the superior aspect, exhibited weaker entrainment and circulation, and resulted in less pronounced glottal skewing. These findings highlight fluid structure interactions within the glottis and underscore the importance of considering the posterior to anterior variations to improve our understanding of voice production mechanisms.
- 1 May 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (5)
Open AccessPhase-locked characterization of intraglottal flow separation vortices and medial surface motion during phonation
This study investigates vocal fold vibration by characterizing glottal geometry and aerodynamic properties at different coronal planes along the posterior to anterior axis in excised canine larynges. Multi-plane, phase locked two-dimensional (2D) particle image velocimetry was used to reconstruct the medial glottal wall geometry and intraglottal flow fields across equidistant coronal planes during phonation. The results reveal significant spatial variation in glottal shape and flow dynamics, with larger glottal openings and divergence angles observed in the mid-coronal and anterior planes compared to the posterior plane. Flow separation vortices (FSV) consistently formed along the medial glottal wall during the closing phase but varied in size and location depending on coronal position. In the mid-coronal and anterior regions, FSV formed closer to the inferior edge and produced stronger flow entrainment, higher circulation, and greater negative gauge pressures, leading to more pronounced flow skewing during closure. In contrast, FSV in the posterior region formed near the superior aspect, exhibited weaker entrainment and circulation, and resulted in less pronounced glottal skewing. These findings highlight fluid structure interactions within the glottis and underscore the importance of considering the posterior to anterior variations to improve our understanding of voice production mechanisms.
- Open Access
- 27 February 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 199, 113234
Effects of infraglottal implantation on voice production in type I thyroplasty: a computational study
- 27 February 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 199, 113234
Open AccessEffects of infraglottal implantation on voice production in type I thyroplasty: a computational study
- 1 October 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (10)
Influence of supraglottal tract on intraglottal pressure during vocal fold closing in human phonation
Two-dimensional fluid–structure interaction (FSI) simulations were conducted to study the influence of the supraglottal tract on intraglottal pressure during vocal fold closing in human phonation. The FSI framework couples a three-mass vocal fold model, an incompressible Navier–Stokes flow solver, and a linear perturbed compressible acoustic solver. Four configurations were simulated under varying subglottal pressures, combining divergent and nearly straight vocal fold closing patterns with and without a supraglottal tract. Comparison of straight closing configurations with and without a supraglottal tract revealed the isolated effect of supraglottal inertance, while the analysis of divergent closing configurations showed the combined effects of supraglottal inertance and intraglottal flow separation. Parameters, including the glottal opening, glottal angle, medial surface wall pressure, which directly reflects how intraglottal pressure is converted to the driving force of the vocal fold motion, and intraglottal flow dynamics, were analyzed. The results show that the supraglottal tract influences intraglottal pressure, as well as the medial surface wall pressure, through two primary mechanisms. First, it reduces medial surface wall pressure through inertance effects during flow deceleration. Second, in the divergent closing configurations, it further decreases medial surface wall pressure by intensifying the flow separation effect. This enhanced flow separation effect is because the supraglottal tract increases peak jet velocity during glottis closing, which strengthens the shear layer and enhances flow circulation after flow separation. Consequently, it leads to more negative glottal pressure, particularly under high subglottal pressures.
- 1 October 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (10)
Influence of supraglottal tract on intraglottal pressure during vocal fold closing in human phonation
Two-dimensional fluid–structure interaction (FSI) simulations were conducted to study the influence of the supraglottal tract on intraglottal pressure during vocal fold closing in human phonation. The FSI framework couples a three-mass vocal fold model, an incompressible Navier–Stokes flow solver, and a linear perturbed compressible acoustic solver. Four configurations were simulated under varying subglottal pressures, combining divergent and nearly straight vocal fold closing patterns with and without a supraglottal tract. Comparison of straight closing configurations with and without a supraglottal tract revealed the isolated effect of supraglottal inertance, while the analysis of divergent closing configurations showed the combined effects of supraglottal inertance and intraglottal flow separation. Parameters, including the glottal opening, glottal angle, medial surface wall pressure, which directly reflects how intraglottal pressure is converted to the driving force of the vocal fold motion, and intraglottal flow dynamics, were analyzed. The results show that the supraglottal tract influences intraglottal pressure, as well as the medial surface wall pressure, through two primary mechanisms. First, it reduces medial surface wall pressure through inertance effects during flow deceleration. Second, in the divergent closing configurations, it further decreases medial surface wall pressure by intensifying the flow separation effect. This enhanced flow separation effect is because the supraglottal tract increases peak jet velocity during glottis closing, which strengthens the shear layer and enhances flow circulation after flow separation. Consequently, it leads to more negative glottal pressure, particularly under high subglottal pressures.
- Open Access
- 18 September 2025
- Published by Wiley in The Laryngoscope
- Vol. 136 (3) , 1311-1319
Vocal Fold Scar Treatment via Controlled Dexamethasone Delivery With a Light‐Activatable Implant
Objective: Intralesional steroid injections for vocal fold (VF) scarring are rapidly cleared, limiting their effectiveness. This study evaluates the efficacy of a light‐activatable dexamethasone implant compared to a single steroid injection for VF scar healing. Methods: Ten rabbits underwent endoscopic VF injury and were treated with either a dexamethasone injection or a light‐activatable implant; injured‐only and no‐injury VFs served as controls. On days 0 and 21, VF implants were irradiated with a near‐infrared pulsed laser for 1 min. Larynges were harvested after 42 days. High‐speed video (> 10 kHz) of excised larynges captured VF vibrations for kymographic analysis. Normal force, structural stiffness, and displacement were measured. Data were analyzed with appropriate statistical tests. Results: Compared to injury‐only VFs, implant‐treated VFs demonstrated significantly reduced normal force and stiffness (5.28 ± 0.77 mN vs. 2.34 ± 0.66 mN, p < 0.0001; 17.74 ± 2.45 mN/mm vs. 6.80 ± 1.32 mN/mm, p < 0.0001), and increased displacement at 1.96 mN (0.14 ± 0.02 mm vs. 0.29 ± 0.05 mm, p < 0.0001) along the injury zone. Implant‐treated VFs exhibited larger amplitude ratios and improved tissue architecture than untreated scars. No differences in quantitative measures were observed between implant‐treated and injection‐treated groups. Conclusion: A light‐activatable dexamethasone implant improved VF biomechanics, vibratory behavior, and histological outcomes in a rabbit injury model comparable to a single steroid injection. This novel approach shows promise for delivering controlled, repeatable therapy to VF scars.
- 18 September 2025
- Published by Wiley in The Laryngoscope
- Vol. 136 (3) , 1311-1319
Open AccessVocal Fold Scar Treatment via Controlled Dexamethasone Delivery With a Light‐Activatable Implant
Objective: Intralesional steroid injections for vocal fold (VF) scarring are rapidly cleared, limiting their effectiveness. This study evaluates the efficacy of a light‐activatable dexamethasone implant compared to a single steroid injection for VF scar healing. Methods: Ten rabbits underwent endoscopic VF injury and were treated with either a dexamethasone injection or a light‐activatable implant; injured‐only and no‐injury VFs served as controls. On days 0 and 21, VF implants were irradiated with a near‐infrared pulsed laser for 1 min. Larynges were harvested after 42 days. High‐speed video (> 10 kHz) of excised larynges captured VF vibrations for kymographic analysis. Normal force, structural stiffness, and displacement were measured. Data were analyzed with appropriate statistical tests. Results: Compared to injury‐only VFs, implant‐treated VFs demonstrated significantly reduced normal force and stiffness (5.28 ± 0.77 mN vs. 2.34 ± 0.66 mN, p < 0.0001; 17.74 ± 2.45 mN/mm vs. 6.80 ± 1.32 mN/mm, p < 0.0001), and increased displacement at 1.96 mN (0.14 ± 0.02 mm vs. 0.29 ± 0.05 mm, p < 0.0001) along the injury zone. Implant‐treated VFs exhibited larger amplitude ratios and improved tissue architecture than untreated scars. No differences in quantitative measures were observed between implant‐treated and injection‐treated groups. Conclusion: A light‐activatable dexamethasone implant improved VF biomechanics, vibratory behavior, and histological outcomes in a rabbit injury model comparable to a single steroid injection. This novel approach shows promise for delivering controlled, repeatable therapy to VF scars.
- Open Access
- 18 June 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (6) , 667
Dynamically Quantifying Vocal Fold Thickness: Effects of Medialization Implant Location on Glottal Shape and Phonation
Unilateral vocal fold paralysis (UVFP) can lead to significant dysphonia. Medialization thyroplasty type 1 (TT1) is a common surgical intervention aiming at improving vocal quality by optimally positioning the paralyzed fold to generate the necessary vibrations for phonation. Implants are generally placed through the thyroid cartilage in a sedated patient and positioned either underneath the level of the vocal folds (infraglottal medialization or IM) or at the level of the vocal folds (glottal medialization or GM). Using high-speed three-dimensional digital image correlation (3D-DIC) in an ex vivo canine hemilarynx model, this study explores the impact of implant location, specifically IM versus GM on the pre-phonatory and dynamic vertical thickness, glottal divergence, flow rate (Q), and cepstral peak prominence (CPP) under varying adduction and subglottal pressure conditions. IM consistently increased glottal divergence and dynamic vertical thickness, particularly in under-adducted states (AL1), despite producing lower static thickness than GM. CPP remained unaffected by the implant condition, but Q decreased significantly with IM under AL1, indicating enhanced glottal resistance and closure. These findings suggest that IM may offer superior functional outcomes by restoring divergent glottal shaping and improving vibratory efficiency. This study also introduces a validated method for dynamically quantifying vocal fold thickness and emphasizes the importance of implant depth in medialization thyroplasty strategies.
- 18 June 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (6) , 667
Open AccessDynamically Quantifying Vocal Fold Thickness: Effects of Medialization Implant Location on Glottal Shape and Phonation
Unilateral vocal fold paralysis (UVFP) can lead to significant dysphonia. Medialization thyroplasty type 1 (TT1) is a common surgical intervention aiming at improving vocal quality by optimally positioning the paralyzed fold to generate the necessary vibrations for phonation. Implants are generally placed through the thyroid cartilage in a sedated patient and positioned either underneath the level of the vocal folds (infraglottal medialization or IM) or at the level of the vocal folds (glottal medialization or GM). Using high-speed three-dimensional digital image correlation (3D-DIC) in an ex vivo canine hemilarynx model, this study explores the impact of implant location, specifically IM versus GM on the pre-phonatory and dynamic vertical thickness, glottal divergence, flow rate (Q), and cepstral peak prominence (CPP) under varying adduction and subglottal pressure conditions. IM consistently increased glottal divergence and dynamic vertical thickness, particularly in under-adducted states (AL1), despite producing lower static thickness than GM. CPP remained unaffected by the implant condition, but Q decreased significantly with IM under AL1, indicating enhanced glottal resistance and closure. These findings suggest that IM may offer superior functional outcomes by restoring divergent glottal shaping and improving vibratory efficiency. This study also introduces a validated method for dynamically quantifying vocal fold thickness and emphasizes the importance of implant depth in medialization thyroplasty strategies.
- 14 December 2024
- Published by Springer Nature in Experiments in Fluids
- Vol. 66 (1) , 7
Volumetric supraglottal jet flow field analysis in synthetic multilayered self-oscillating vocal fold model
Recent research highlights the need for comprehensive three-dimensional (3D) analysis of laryngeal flow to better understand voice production, as traditional 2D methods fail to capture the full complexity of supraglottal jet dynamics. This study employed tomographic particle image velocimetry to capture the volume velocity flow fields in a synthetic multilayered vocal fold model. The impact of increased airway resistance from different vocal tract configurations was examined. Results indicated that adding a vocal tract reduced the maximum axial velocity and jet displacement, particularly at low subglottal pressure (Psg). Higher Psg increased both the maximum axial velocity and jet displacement. For all configurations, with and without a vocal tract, the vocal folds were observed to open at the posterior and anterior edges first, indicated by a double jet formation at the beginning of the opening phase, followed by an elongated jet during peak flow and a double jet at the posterior and anterior edges during the closing phase. Contrary to previous studies, the glottal flow waveforms became more symmetric between the opening and closing phases with higher Psg and the presence of a vocal tract. Additionally, vocal efficiency (VE) decreased while cepstral peak prominence increased with higher Psg. Overall, this study provides further insights into the influence of vocal tract configurations on the supraglottal jet and supports the correlation between glottal flow skewing and VE.
- 14 December 2024
- Published by Springer Nature in Experiments in Fluids
- Vol. 66 (1) , 7
Volumetric supraglottal jet flow field analysis in synthetic multilayered self-oscillating vocal fold model
Recent research highlights the need for comprehensive three-dimensional (3D) analysis of laryngeal flow to better understand voice production, as traditional 2D methods fail to capture the full complexity of supraglottal jet dynamics. This study employed tomographic particle image velocimetry to capture the volume velocity flow fields in a synthetic multilayered vocal fold model. The impact of increased airway resistance from different vocal tract configurations was examined. Results indicated that adding a vocal tract reduced the maximum axial velocity and jet displacement, particularly at low subglottal pressure (Psg). Higher Psg increased both the maximum axial velocity and jet displacement. For all configurations, with and without a vocal tract, the vocal folds were observed to open at the posterior and anterior edges first, indicated by a double jet formation at the beginning of the opening phase, followed by an elongated jet during peak flow and a double jet at the posterior and anterior edges during the closing phase. Contrary to previous studies, the glottal flow waveforms became more symmetric between the opening and closing phases with higher Psg and the presence of a vocal tract. Additionally, vocal efficiency (VE) decreased while cepstral peak prominence increased with higher Psg. Overall, this study provides further insights into the influence of vocal tract configurations on the supraglottal jet and supports the correlation between glottal flow skewing and VE.
- 9 December 2024
- Published by Elsevier in Journal of Voice
Infraglottal Medialization: Increasing Vocal Fold Stiffness Gradient for Improved Vocal Efficiency
- 9 December 2024
- Published by Elsevier in Journal of Voice
Infraglottal Medialization: Increasing Vocal Fold Stiffness Gradient for Improved Vocal Efficiency
- Open Access
- 15 August 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (8) , 834
Comparison of Aerodynamic and Elastic Properties in Tissue and Synthetic Models of Vocal Fold Vibrations
Three laryngeal models were used to investigate the aerodynamic and elastic properties of vocal fold vibration: cadaveric human, excised canine, and synthetic silicone vocal folds. The aim was to compare the characteristics of these models to enhance our understanding of phonatory mechanisms. Flow and medial glottal wall geometry were acquired via particle image velocimetry. Elastic properties were assessed from force–displacement tests. Relatively, the human larynges had higher fundamental frequency values, while canine and synthetic models exhibited greater flow rates. Canine models demonstrated the highest divergence angles and vertical stiffness gradients followed by the human model, both displaying flow separation vortices during closing. Synthetic models, whose advantage is their accessibility and repeatability, displayed the lowest glottal divergence angles and total circulation values compared to tissue models with no flow separation vortices. The elasticity tests revealed that tissue models showed significant hysteresis and vertical stiffness gradients, unlike the synthetic models. These results underscore the importance of model selection based on specific research needs and highlight the potential of canine and synthetic models for controlled experimental studies in phonation.
- 15 August 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (8) , 834
Open AccessComparison of Aerodynamic and Elastic Properties in Tissue and Synthetic Models of Vocal Fold Vibrations
Three laryngeal models were used to investigate the aerodynamic and elastic properties of vocal fold vibration: cadaveric human, excised canine, and synthetic silicone vocal folds. The aim was to compare the characteristics of these models to enhance our understanding of phonatory mechanisms. Flow and medial glottal wall geometry were acquired via particle image velocimetry. Elastic properties were assessed from force–displacement tests. Relatively, the human larynges had higher fundamental frequency values, while canine and synthetic models exhibited greater flow rates. Canine models demonstrated the highest divergence angles and vertical stiffness gradients followed by the human model, both displaying flow separation vortices during closing. Synthetic models, whose advantage is their accessibility and repeatability, displayed the lowest glottal divergence angles and total circulation values compared to tissue models with no flow separation vortices. The elasticity tests revealed that tissue models showed significant hysteresis and vertical stiffness gradients, unlike the synthetic models. These results underscore the importance of model selection based on specific research needs and highlight the potential of canine and synthetic models for controlled experimental studies in phonation.
- 12 December 2023
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 146 (2) , 1-51
The Effect of an Increasing Subglottal Stenosis Constriction That Extends From the Vocal Folds to the Inferior Border of the Cricoid Cartilage
Acquired subglottal stenosis is an unpredicted complication that can occur in some patients who have undergone prolonged endotracheal intubation. It is a narrowing of the airway at the level of the cricoid cartilage that can restrict airflow and cause breathing difficulty. Stenosis is typically treated with endoscopic airway dilation, with some patients experiencing multiple recurrences. The study highlights the potential of computational fluid dynamics as a non-invasive method for monitoring subglottic stenosis, which can aid in early diagnosis and surgical planning. An anatomically accurate human laryngeal airway model was constructed from computerized tomography (CT) scans. The subglottis cross-sectional area was narrowed systematically using ≈10% decrements. A quadratic profile was used to interpolate the transformation of the airway geometry from its modified shape to the baseline geometry. The numerical results were validated by static pressure measurements conducted in a physical model. The results show that airway resistance follows a squared ratio that is inversely proportional to the size of the subglottal opening (R∝A-2). The study found that critical constriction occurs in the subglottal region at 70% stenosis (upper end of grade 2). Moreover, removing airway tissue below 40% stenosis during surgical intervention does not significantly decrease airway resistance.
- 12 December 2023
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 146 (2) , 1-51
The Effect of an Increasing Subglottal Stenosis Constriction That Extends From the Vocal Folds to the Inferior Border of the Cricoid Cartilage
Acquired subglottal stenosis is an unpredicted complication that can occur in some patients who have undergone prolonged endotracheal intubation. It is a narrowing of the airway at the level of the cricoid cartilage that can restrict airflow and cause breathing difficulty. Stenosis is typically treated with endoscopic airway dilation, with some patients experiencing multiple recurrences. The study highlights the potential of computational fluid dynamics as a non-invasive method for monitoring subglottic stenosis, which can aid in early diagnosis and surgical planning. An anatomically accurate human laryngeal airway model was constructed from computerized tomography (CT) scans. The subglottis cross-sectional area was narrowed systematically using ≈10% decrements. A quadratic profile was used to interpolate the transformation of the airway geometry from its modified shape to the baseline geometry. The numerical results were validated by static pressure measurements conducted in a physical model. The results show that airway resistance follows a squared ratio that is inversely proportional to the size of the subglottal opening (R∝A-2). The study found that critical constriction occurs in the subglottal region at 70% stenosis (upper end of grade 2). Moreover, removing airway tissue below 40% stenosis during surgical intervention does not significantly decrease airway resistance.
- Open Access
- 18 October 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (10) , 1215
The Effects of Negative Pressure Induced by Flow Separation Vortices on Vocal Fold Dynamics during Voice Production
This study used a two-dimensional flow-structure-interaction computer model to investigate the effects of flow-separation-vortex-induced negative pressure on vocal fold vibration and flow dynamics during vocal fold vibration. The study found that negative pressure induced by flow separation vortices enhances vocal fold vibration by increasing aeroelastic energy transfer during vibration. The result showed that the intraglottal pressure was predominantly negative after flow separation before gradually recovering to zero at the glottis exit. When the negative pressure was removed, the vibration amplitude and flow rate were reduced by up to 20%, and the closing speed, flow skewness quotient, and maximum flow declination rate were reduced by up to 40%. The study provides insights into the complex interactions between flow dynamics, vocal fold vibration, and energy transfer during voice production.
- 18 October 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (10) , 1215
Open AccessThe Effects of Negative Pressure Induced by Flow Separation Vortices on Vocal Fold Dynamics during Voice Production
This study used a two-dimensional flow-structure-interaction computer model to investigate the effects of flow-separation-vortex-induced negative pressure on vocal fold vibration and flow dynamics during vocal fold vibration. The study found that negative pressure induced by flow separation vortices enhances vocal fold vibration by increasing aeroelastic energy transfer during vibration. The result showed that the intraglottal pressure was predominantly negative after flow separation before gradually recovering to zero at the glottis exit. When the negative pressure was removed, the vibration amplitude and flow rate were reduced by up to 20%, and the closing speed, flow skewness quotient, and maximum flow declination rate were reduced by up to 40%. The study provides insights into the complex interactions between flow dynamics, vocal fold vibration, and energy transfer during voice production.