Zhuangsheng Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhuangsheng Zhu has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
Haoying Pang
3 shared publications- Jianli Li
Beihang University
3 shared publications Yi-An Xu
3 shared publications- Chunyu Qu
Beihang University
2 shared publications - Jin Li
School of Instrumentation and Optoelectronic Engineering Beihang University Beijing China
2 shared publications Libo Zhao
2 shared publications
Latest Publications
- 8 October 2026
- Published by Elsevier in Surfaces and Interfaces
- Vol. 101
Research advances in anti-relaxation coatings for alkali-metal vaporcells: materials, mechanisms and processes
- 8 October 2026
- Published by Elsevier in Surfaces and Interfaces
- Vol. 101
Research advances in anti-relaxation coatings for alkali-metal vaporcells: materials, mechanisms and processes
- 3 August 2026
- Published by Elsevier in Measurement
- Vol. 290
Quantitative filling of high-purity rubidium into vapor cells via a zoned temperature gradient: Simulation and experimental validation
- 3 August 2026
- Published by Elsevier in Measurement
- Vol. 290
Quantitative filling of high-purity rubidium into vapor cells via a zoned temperature gradient: Simulation and experimental validation
- Open Access
- 20 March 2026
- Published by Springer Nature in EPJ Quantum Technology
Dynamic suppression of phase errors in optically pumped atomic magnetometers for applications in geomagnetic environments
- 20 March 2026
- Published by Springer Nature in EPJ Quantum Technology
Open AccessDynamic suppression of phase errors in optically pumped atomic magnetometers for applications in geomagnetic environments
- 9 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-11
Coating-Enabled Buffer-Gas-Free Vapor Cell: A New Sensor Architecture for Single-Beam SERF Magnetometers
Alkali metal vapor cells are fundamental components in quantum sensors, and their relaxation characteristics critically influence both sensitivity and system stability. In Spin-Exchange Relaxation-Free (SERF) atomic magnetometers, although spin-exchange collisions are effectively suppressed, wall-collision-induced relaxation remains the primary limiting factor. A coating-enabled buffer-gas-free vapor cell (CBF-VC) is proposed as a novel sensor unit, realized through multilayer octadecyltrichlorosilane (OTS) selfassembled molecular coatings. The CBF-VC is integrated into a single-beam SERF atomic magnetometer, and experimental validation is conducted. The results indicate a significant extension of the wall collision relaxation time from 40.19 ms. This extended relaxation time directly enhances the magnetometer sensitivity by 48%, confirming the feasibility of CBF-VCs as a measurement-oriented vapor cell architecture. The findings demonstrate not only the effectiveness of anti-relaxation coatings, but also a new instrumentation pathway for advancing next-generation quantum sensing.
- 9 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-11
Coating-Enabled Buffer-Gas-Free Vapor Cell: A New Sensor Architecture for Single-Beam SERF Magnetometers
Alkali metal vapor cells are fundamental components in quantum sensors, and their relaxation characteristics critically influence both sensitivity and system stability. In Spin-Exchange Relaxation-Free (SERF) atomic magnetometers, although spin-exchange collisions are effectively suppressed, wall-collision-induced relaxation remains the primary limiting factor. A coating-enabled buffer-gas-free vapor cell (CBF-VC) is proposed as a novel sensor unit, realized through multilayer octadecyltrichlorosilane (OTS) selfassembled molecular coatings. The CBF-VC is integrated into a single-beam SERF atomic magnetometer, and experimental validation is conducted. The results indicate a significant extension of the wall collision relaxation time from 40.19 ms. This extended relaxation time directly enhances the magnetometer sensitivity by 48%, confirming the feasibility of CBF-VCs as a measurement-oriented vapor cell architecture. The findings demonstrate not only the effectiveness of anti-relaxation coatings, but also a new instrumentation pathway for advancing next-generation quantum sensing.
- Open Access
- 26 February 2026
- Published by Elsevier in Materials Today Advances
- Vol. 29
Regulating surface energy and adsorption potential of glass interfaces using mixed-chain chlorosilane multilayer films
- 26 February 2026
- Published by Elsevier in Materials Today Advances
- Vol. 29
Open AccessRegulating surface energy and adsorption potential of glass interfaces using mixed-chain chlorosilane multilayer films
- 15 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-11
Assessment of Relaxation Components in Optically Pumped Magnetometers Under Operational Conditions
The deterioration of spin coherence has been a significant challenge in the field of quantum magnetic measurements based on optically pumped atomic magnetometers (OPAMs). However, measurement and evaluation methods for specific relaxation components of OPAMs under working conditions remain lacking, which impedes further improvement in OPAM performance. To address this, we propose a methodology for quantifying the relaxation components of an OPAM under realistic operating conditions. Using this method, we confirm the existence of an anomalous relaxation mechanism induced by radio frequency (RF) magnetic fields and develop an empirical expression to describe its behavior. The results experimentally demonstrate that, in addition to the well-known spin-exchange relaxation, the dominant contributions to spin relaxation arise from optical pumping and RF magnetic fields. This work paves the way for sensitivity enhancement in quantum magnetometry and refines the theoretical understanding of relaxation mechanisms in OPAMs.
- 15 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-11
Assessment of Relaxation Components in Optically Pumped Magnetometers Under Operational Conditions
The deterioration of spin coherence has been a significant challenge in the field of quantum magnetic measurements based on optically pumped atomic magnetometers (OPAMs). However, measurement and evaluation methods for specific relaxation components of OPAMs under working conditions remain lacking, which impedes further improvement in OPAM performance. To address this, we propose a methodology for quantifying the relaxation components of an OPAM under realistic operating conditions. Using this method, we confirm the existence of an anomalous relaxation mechanism induced by radio frequency (RF) magnetic fields and develop an empirical expression to describe its behavior. The results experimentally demonstrate that, in addition to the well-known spin-exchange relaxation, the dominant contributions to spin relaxation arise from optical pumping and RF magnetic fields. This work paves the way for sensitivity enhancement in quantum magnetometry and refines the theoretical understanding of relaxation mechanisms in OPAMs.
- 8 November 2024
- Published by Elsevier in Measurement
- Vol. 242
A non-thermal method to maintain alkali vapor density of anti-relaxation coating cell in spin exchange relaxation-free magnetometer
- 8 November 2024
- Published by Elsevier in Measurement
- Vol. 242
A non-thermal method to maintain alkali vapor density of anti-relaxation coating cell in spin exchange relaxation-free magnetometer
- Open Access
- 16 July 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (14) , 3420
Design and Development of Array POS for Airborne Remote Sensing Motion Compensation
Multi-antenna airborne remote sensing systems have received more attention recently because they can realize high-resolution three-dimensional (3-D) imaging, such as array Synthetic Aperture Radar (SAR). Their high-precision imaging needs multi-antenna motion and relative motion between antennas. However, the existing facility and technology hardly meet the motion measurement precision demand of array SAR. To solve this problem, an array Position and Orientation System (POS) for airborne remote sensing motion compensation is designed and developed. It is composed of a high-precision POS, several small-size Inertial Measurement Units (IMU), and a 6-D deformation measurement system based on Fiber Bragg Grating (FBG) sensors. Firstly, the transfer alignment method based on 6-D deformation is used to measure the relative motion between array POS. Then, the motion conversion method from array POS to array SAR is presented to obtain the multi-antenna motion and relative motion between antennas. Finally, the ground experiment results identify that the accuracies of multi-antenna position, multi-antenna attitude, and flexible baseline length between antennas are superior to 3 cm, 0.01°, and 0.1 mm, respectively, which can meet the motion measurement precision demand of array SAR.
- 16 July 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (14) , 3420
Open AccessDesign and Development of Array POS for Airborne Remote Sensing Motion Compensation
Multi-antenna airborne remote sensing systems have received more attention recently because they can realize high-resolution three-dimensional (3-D) imaging, such as array Synthetic Aperture Radar (SAR). Their high-precision imaging needs multi-antenna motion and relative motion between antennas. However, the existing facility and technology hardly meet the motion measurement precision demand of array SAR. To solve this problem, an array Position and Orientation System (POS) for airborne remote sensing motion compensation is designed and developed. It is composed of a high-precision POS, several small-size Inertial Measurement Units (IMU), and a 6-D deformation measurement system based on Fiber Bragg Grating (FBG) sensors. Firstly, the transfer alignment method based on 6-D deformation is used to measure the relative motion between array POS. Then, the motion conversion method from array POS to array SAR is presented to obtain the multi-antenna motion and relative motion between antennas. Finally, the ground experiment results identify that the accuracies of multi-antenna position, multi-antenna attitude, and flexible baseline length between antennas are superior to 3 cm, 0.01°, and 0.1 mm, respectively, which can meet the motion measurement precision demand of array SAR.
- 6 August 2021
- Published by Cambridge University Press (CUP) in Journal of Navigation
- Vol. 75 (4) , 784-804
Research on a modeling method of wing deformation under the influence of separation and compound multi-source disturbance
An aircraft wing is the carrier of imaging payload (interferometric synthetic aperture radar (SAR) or array SAR) of a high-resolution aerial remote sensing system, and high-precision estimation of wing deformation is the key. There are two main traditional modelling methods for wing deformation, namely stochastic theory modelling and material mechanics modelling only dealing with single disturbance, of which the model parameters are derived from empirical values. Aiming at the complex multi-source disturbance of an aircraft wing, this paper separately probes the influence of external disturbance (air disturbance) and internal disturbance (engine vibration) based on the real-time observation of sensors and classifies the wing deformation on the basis of auto-regressive (AR) modelling for parameter identification. With the authentic flight data of a certain types of aircraft, the experimental analysis shows that the wing deformation under the influence of engine vibration is the 14th-order AR model, and the wing deformation under the influence of turbulence is the fifth-order AR model. Meanwhile, this paper also provides an experimental verification idea for the wing deflection modelling built on the second- or third-order Markov model.
- 6 August 2021
- Published by Cambridge University Press (CUP) in Journal of Navigation
- Vol. 75 (4) , 784-804
Research on a modeling method of wing deformation under the influence of separation and compound multi-source disturbance
An aircraft wing is the carrier of imaging payload (interferometric synthetic aperture radar (SAR) or array SAR) of a high-resolution aerial remote sensing system, and high-precision estimation of wing deformation is the key. There are two main traditional modelling methods for wing deformation, namely stochastic theory modelling and material mechanics modelling only dealing with single disturbance, of which the model parameters are derived from empirical values. Aiming at the complex multi-source disturbance of an aircraft wing, this paper separately probes the influence of external disturbance (air disturbance) and internal disturbance (engine vibration) based on the real-time observation of sensors and classifies the wing deformation on the basis of auto-regressive (AR) modelling for parameter identification. With the authentic flight data of a certain types of aircraft, the experimental analysis shows that the wing deformation under the influence of engine vibration is the 14th-order AR model, and the wing deformation under the influence of turbulence is the fifth-order AR model. Meanwhile, this paper also provides an experimental verification idea for the wing deflection modelling built on the second- or third-order Markov model.
- 5 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (18) , 20324-20334
A Time Synchronization Method Between FBG Deformation Measurement System and Airborne DPOS Based on Waveform Matching
The airborne Distributed Position and Orientation System (DPOS) is an important means for multi-point motion measurement required for earth observation with multi-task sensing loads. The sub-nodes in DPOS rely on the main node to perform transfer alignment for them to get high-precision motion data, which requires accurate deformation data and the relative motion relationship between different nodes. Fiber Bragg Grating (FBG) is one of the main means of deformation measurement at present. However, the time synchronization error between FBG and DPOS directly restricts the accuracy of transfer alignment. For this, a high-precision time synchronization method based on waveform matching is presented. Firstly, the data correlation between FBG and DPOS is analyzed. Then the main time error factors, sampling frequency and time delay are determined. On this basis, the empirical mode decomposition and wavelet analysis are used to extract and match the vibration data from the FBGS and bending angle data calculated by DPOS, thus updating the time-varying sampling frequency and time delay of FBGS, and finally achieving high-precision time synchronization between FBGS and DPOS. Results of ground dynamic experiment show that the standard deviation and mean value of FBG time error is less than 4ms and 2ms respectively, and the deformation displacement error of synchronized FBG data is less than 1%, which provides a prerequisite for high-precision transfer alignment of DPOS.
- 5 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (18) , 20324-20334
A Time Synchronization Method Between FBG Deformation Measurement System and Airborne DPOS Based on Waveform Matching
The airborne Distributed Position and Orientation System (DPOS) is an important means for multi-point motion measurement required for earth observation with multi-task sensing loads. The sub-nodes in DPOS rely on the main node to perform transfer alignment for them to get high-precision motion data, which requires accurate deformation data and the relative motion relationship between different nodes. Fiber Bragg Grating (FBG) is one of the main means of deformation measurement at present. However, the time synchronization error between FBG and DPOS directly restricts the accuracy of transfer alignment. For this, a high-precision time synchronization method based on waveform matching is presented. Firstly, the data correlation between FBG and DPOS is analyzed. Then the main time error factors, sampling frequency and time delay are determined. On this basis, the empirical mode decomposition and wavelet analysis are used to extract and match the vibration data from the FBGS and bending angle data calculated by DPOS, thus updating the time-varying sampling frequency and time delay of FBGS, and finally achieving high-precision time synchronization between FBGS and DPOS. Results of ground dynamic experiment show that the standard deviation and mean value of FBG time error is less than 4ms and 2ms respectively, and the deformation displacement error of synchronized FBG data is less than 1%, which provides a prerequisite for high-precision transfer alignment of DPOS.