Sabine Zakel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sabine Zakel has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
- Stefan H. Spitzer
VSB-Technical University of Ostrava, Faculty of Safety Engineering, Centre of Excellence for Safety Research, Ostrava, Moravian-Silesian Region, 70800, Czech Republic
5 shared publications Elisabeth Brandes
3 shared publications- Maria Mitu
Institute of Physical Chemistry—Ilie Murgulescu, Romanian Academy, 202 Splaiul Independenței, 060021 Bucharest, Romania
3 shared publications Bernd Güttler
Physikalisch-Technische Bundesanstalt (PTB); Bundesallee 100 38116 Braunschweig Germany
2 shared publicationsClaudia Frank
German national metrology institute
2 shared publications- Claudia Swart
PTB, Braunschweig, Germany
2 shared publications
Latest Publications
- Open Access
- 3 February 2026
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 101
Hot flame detection in a completely automated autoignition temperature measurement apparatus
- 3 February 2026
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 101
Open AccessHot flame detection in a completely automated autoignition temperature measurement apparatus
- 9 April 2025
- Published by Elsevier in Powder Technology
- Vol. 459
Influence of the particle distribution on dust explosions in the 20 L sphere
- 9 April 2025
- Published by Elsevier in Powder Technology
- Vol. 459
Influence of the particle distribution on dust explosions in the 20 L sphere
- 25 January 2025
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 94
Testing ignition of hybrid mixtures by brush discharges
- 25 January 2025
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 94
Testing ignition of hybrid mixtures by brush discharges
- 9 February 2024
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 88
European round robin on safety characteristics of hybrid mixtures from vapors and dusts
- 9 February 2024
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 88
European round robin on safety characteristics of hybrid mixtures from vapors and dusts
- Open Access
A New Ignition Source for the Determination of Safety Characteristics of Gases
Safety characteristics are used to keep processes, including flammable gases, vapors, and combustible dusts, safe. In the standards for the determination of safety characteristics of gases and vapors, the induction spark is commonly used. However, classic transformers are hard to obtain, and replacement with new electronic transformers is not explicitly allowed in the standards. This article presents the investigation of five gases that are normally used to calibrate devices for the determination of safety characteristics, the maximum experimental safe gap (MESG), with an electronic transformer, and the values are compared to the ones that are obtained with the standard transformer. Additionally, calorimetric measurements on the net energy of both ignition sources were performed as well as open-circuit voltage measurements. It is concluded that the classic type of transformer can be replaced by the new type obtaining the same results for the MESG and introducing the same amount of energy into the system.
Open AccessA New Ignition Source for the Determination of Safety Characteristics of Gases
Safety characteristics are used to keep processes, including flammable gases, vapors, and combustible dusts, safe. In the standards for the determination of safety characteristics of gases and vapors, the induction spark is commonly used. However, classic transformers are hard to obtain, and replacement with new electronic transformers is not explicitly allowed in the standards. This article presents the investigation of five gases that are normally used to calibrate devices for the determination of safety characteristics, the maximum experimental safe gap (MESG), with an electronic transformer, and the values are compared to the ones that are obtained with the standard transformer. Additionally, calorimetric measurements on the net energy of both ignition sources were performed as well as open-circuit voltage measurements. It is concluded that the classic type of transformer can be replaced by the new type obtaining the same results for the MESG and introducing the same amount of energy into the system.
- Open Access
Requirements for a Hybrid Dust-Gas-Standard: Influence of the Mixing Procedure on Safety Characteristics of Hybrid Mixtures
While developing a standard for the determination of safety characteristics for hybrid mixtures the authors discovered, that, beside the ignition source, the mixing procedure is the main difference between the single-phase standards for dusts and gases. The preparation of hybrid mixtures containing a flammable gas and a flammable dust in the 20 L-sphere can be realized in different ways. Either the flammable gas is filled only in the sphere or only in the dust container or in both. In previous works, almost always the first method is applied, without giving any information on the accuracy of the gas mixtures. In this work the accuracy of the gas mixtures and the results of the tests applying two methods of mixing were studied. No significant influence of the mixing method itself on the safety characteristics explosion pressure pex and the normalized rate of pressure rise (K-value) was found. Obviously, homogenization of the gas mixtures can be obtained sufficiently by the turbulence that is caused during the injection from the dust container into the explosion chamber within a short time. However, the mixing procedure has a great influence on the accuracy of the gas amount of the mixtures obtained. Without modifying the 20 L-sphere by installing precise pressure sensors, assuring its tightness and performing gas analysis, it must be expected, that the accuracy of the gas mixtures is very low. This has a significant influence on the measured safety characteristics and may lead to unsafe facilities or unnecessary expensive safety measures.
Open AccessRequirements for a Hybrid Dust-Gas-Standard: Influence of the Mixing Procedure on Safety Characteristics of Hybrid Mixtures
While developing a standard for the determination of safety characteristics for hybrid mixtures the authors discovered, that, beside the ignition source, the mixing procedure is the main difference between the single-phase standards for dusts and gases. The preparation of hybrid mixtures containing a flammable gas and a flammable dust in the 20 L-sphere can be realized in different ways. Either the flammable gas is filled only in the sphere or only in the dust container or in both. In previous works, almost always the first method is applied, without giving any information on the accuracy of the gas mixtures. In this work the accuracy of the gas mixtures and the results of the tests applying two methods of mixing were studied. No significant influence of the mixing method itself on the safety characteristics explosion pressure pex and the normalized rate of pressure rise (K-value) was found. Obviously, homogenization of the gas mixtures can be obtained sufficiently by the turbulence that is caused during the injection from the dust container into the explosion chamber within a short time. However, the mixing procedure has a great influence on the accuracy of the gas amount of the mixtures obtained. Without modifying the 20 L-sphere by installing precise pressure sensors, assuring its tightness and performing gas analysis, it must be expected, that the accuracy of the gas mixtures is very low. This has a significant influence on the measured safety characteristics and may lead to unsafe facilities or unnecessary expensive safety measures.
- 1 September 2021
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 72
CEQAT-DGHS interlaboratory tests for chemical safety: Validation of laboratory test methods by determining the measurement uncertainty and probability of incorrect classification including so-called “Shark profiles”
- 1 September 2021
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 72
CEQAT-DGHS interlaboratory tests for chemical safety: Validation of laboratory test methods by determining the measurement uncertainty and probability of incorrect classification including so-called “Shark profiles”
- 1 July 2021
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 71
Burning and explosion behaviour of ethanol/water - sucrose mixtures
- 1 July 2021
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 71
Burning and explosion behaviour of ethanol/water - sucrose mixtures