YSYoungseob Seo

Youngseob Seo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Youngseob Seo has a total of 33 co-authors. Here are the top co-authors by number of shared publications:

  • Zhiyue J. Wang

    Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, USA

    4 shared publications
  • Nancy K. Rollins

    Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, USA

    3 shared publications
  • Zhiyue J. Wang

    Department of Radiology, University of Texas Southwestern Medical Center, Dallas, USA

    2 shared publications
  • Ana Nava

    Analytical Imaging and Modeling Center, Children's Health, Dallas, Texas, USA

    1 shared publication
  • Ashok Panigrahy

    Department of Pediatric Radiology Children's Hospital of Pittsburgh Pittsburgh PA USA

    1 shared publication
  • Barbara Holshouser

    MRI Department Loma Linda University Loma Linda CA USA

    1 shared publication

Latest Publications

    • 1 March 2026
      • Vol. 53  (3) , e70315
    Open Access

    Visualization of small vibrations inside an MRI scanner using video motion amplification.

    by Youngseob Seo, Zhiyue J Wang

    Diffusion-weighted magnetic resonance imaging (DW-MRI) acquisition requires the application of strong magnetic field gradients, which can induce mechanical vibrations in tissues or phantoms, potentially leading to signal loss or degradation. A qualitative assessment of these vibrations would be valuable for quality assurance (QA). Conventional methods, such as piezoelectric accelerometers and laser interferometry, have limitations in their applicability and availability. There remains a need for a readily accessible method to detect and characterize these vibrations as part of a robust QA protocol. The objective of this study is to investigate the feasibility of using motion amplification of high-speed video to assess vibrations during DW-MRI scanning. A gel phantom simulating a human head was positioned supine within a head receive coil inside an MRI scanner. A 45-degree angled mirror was placed to visualize the phantom's face, while a high-speed camera, positioned outside the scanner, was used to record videos under two conditions: (1) the scanner in an idle state (still condition), and (2) during a DW-MRI scan (vibration condition). The recorded videos were processed using a motion amplification software tool to enhance subtle movements. The motion of multiple position markers affixed to the phantom was quantitatively analyzed. No motion was visible to the naked eye under either still or scanning conditions. However, motion amplification revealed clear marker displacement during DW-MRI, with substantially smaller movement during scanner idling. Across all facial markers and directions (X (L-R), Y (A-P) and Z (I-S)), median root-mean-square displacement increased from 0.85 µm (range: 0.61-1.50 µm) at idle to 2.59 µm (2.04-4.31 µm) during DW-MRI scanning (b = 2500 s/mm2). Similarly, median peak-to-peak displacement rose from 7.71 µm (3.92-10.37 µm) to 18.47 µm (15.22-31.77 µm). Motion amplification of high-speed video provides a viable method for detecting and analyzing vibrations during MRI scans. This approach could serve as a valuable tool for QA, offering an alternative to conventional vibration assessment techniques.

  • Open Access

    Efficacy and Safety of Cyclosporine and Tacrolimus in Rheumatoid Arthritis: A Systematic Review and Meta‐Analysis

    by GeunTae Kim, Sung Ryul Shim, Youngseob Seo, Hokeun Sun

    Aims: This study aimed to evaluate the efficacy and safety of calcineurin inhibitors (CNIs), cyclosporine (CSA), and tacrolimus (TAC) in patients with active rheumatoid arthritis (RA) based on randomized controlled trials (RCTs). Methods: A systematic literature search of PubMed, the Cochrane Library, and EMBASE was conducted to identify RCTs comparing CSA and TAC with placebo in RA. Outcomes included American College of Rheumatology (ACR) responses, assessments of tender and swollen joint counts, inflammatory markers, global assessments, and safety endpoints. The primary efficacy outcome was the ACR20 response rate, and the primary safety outcome was the mean increment in serum creatinine (s‐Cr). Subgroup analyses were performed to assess dose‐dependent effects. Results: Eleven RCTs (7 CSA, 4 TAC) including 1793 patients were analyzed. Both CSA (RR 1.559, 95% CI 1.099; 2.213, p = 0.013) and TAC (RR 2.139, 95% CI 1.769; 2.586, p < 0.001) significantly improved ACR20 response rates compared to placebo. Secondary efficacy outcomes showing significant differences from placebo were more frequently observed in TAC than in CSA. TAC showed less dose‐dependence, whereas CSA showed a more dose‐dependent trend. Regarding safety, CSA was associated with dose‐dependent increases in s‐Cr and secondary safety outcomes. TAC showed a mild but consistent increase in s‐Cr regardless of dose, and no significant increase in secondary safety outcomes was observed at lower doses. At lower doses, both drugs maintained efficacy and were associated with fewer adverse events (AEs). Conclusions: CSA and TAC were effective in patients with RA who had an inadequate response to disease‐modifying antirheumatic drugs. Both drugs maintained efficacy and were associated with fewer AEs at lower doses. These findings provide context for considering lower‐dose CNI regimens in selected patient populations. However, concerns about long‐term safety remain, and further long‐term studies are needed to clarify the role of CNIs in the treatment of RA.


  • Open Access

    Ajania pacifica (Nakai) K. Bremer and Humphries Extract Limits MYC Expression to Induce Apoptosis in Diffuse Large B Cell Lymphoma

    by Ye-Rin Woo, Chan-Seong Kwon, Ji-Eun Lee, Byeol-Eun Jeon, Tae-Jin Kim, Joy Choo, Young-Seob Seo, Sang-Woo Kim

    The proto-oncogene MYC is frequently dysregulated in patients with diffuse large B-cell lymphoma (DLBCL) and plays a critical role in disease progression. To improve the clinical outcomes of patients with DLBCL, the development of strategies to target MYC is crucial. The use of medicinal plants for developing anticancer drugs has garnered considerable attention owing to their diverse mechanisms of action. In this study, 100 plant extracts of flora from the Republic of Korea were screened to search for novel agents with anti-DLBCL effects. Among them, Ajania pacifica (Nakai) K. Bremer and Humphries extract (APKH) efficiently suppressed the survival of DLBCL cells, while showing minimal toxicity toward normal murine bone marrow cells. APKH suppressed the expression of anti-apoptotic BCL2 family members, causing an imbalance between the pro-apoptotic and anti-apoptotic BCL2 members. This disrupted mitochondrial membrane potential, cytochrome c release, and pro-caspase-3 activation and eventually led to DLBCL cell death. Importantly, MYC expression was markedly downregulated by APKH and ectopic expression of MYC in DLBCL cells abolished the pro-apoptotic effects of APKH. These results demonstrate that APKH exerts anti-DLBCL effects by inhibiting MYC expression. Moreover, when combined with doxorubicin, an essential component of the CHOP regimen (cyclophosphamide, doxorubicin, vincristine, and prednisone), APKH synergistically enhanced the therapeutic effect of doxorubicin. This indicates that APKH may overcome drug resistance, which is common in patients with refractory/relapsed DLBCL. To identify compounds with anti-DLBCL activities in APKH, the chemical profile analysis of APKH was performed using UPLC-QTOF/MSe analysis and assessed for its anticancer activity. Based on the UPLC-QTOF/MSe chemical profiling, it is conceivable that APKH may serve as a novel agent targeting MYC and sensitizing drug-resistant DLBCL cells to CHOP chemotherapy. Further studies to elucidate how the compounds in APKH exert tumor-suppressive role in DLBCL are warranted.


  • Open Access

    Limitations of Surface Current Model of Magnetic Field and a Remedy

    by Youngseob Seo, Zhiyue J. Wang

    It is well known that any realistic static magnetic field in a source-free volume can be generated by electric currents on a surface enclosing the volume. The magnetic field generated by surface currents is equivalent to that from magnetic dipoles distributed on the surface and along the surface normal directions. We demonstrate the limitations of the surface current model for instrumentation, and show vertical current loops corresponding to magnetic dipoles along the surface tangential directions may be employed to mitigate these limitations. We consider loop coil elements distributed on a cylindrical surface. A closed-surface array has loops on the entire surface, and an open-surface array does not have loops on the surface of both ends. A coil array may contain only flat elements (each loop is inside the cylindrical surface) or composite elements consisting of three orthogonal loops (one flat loop and two vertical loops) instead of just one flat loop at the location of each element. With computer simulations, the array coils were tested for generating the spatial field pattern of a vertical loop or a linear field gradient. The simulations showed that (1) an open-surface composite loop array produces less errors than a similar flat loop array in generating linear field patterns; the percentage root mean square error (RMSE) of the composite coil loops was 8.46% compared to 21.5% for the similar flat loops; (2) A composite loop array consumes less power than a corresponding flat array. For the open-surface array with a similar number of loops, the power consumption of the composite loop array was 73.9 versus 184 (arbitrary power units) for the flat loop array.


  • Open Access

    Measurement and evaluation of specific absorption rate and temperature elevation caused by an artificial hip joint during MRI scanning

    by Youngseob Seo, Zhiyue J. Wang

    A primary safety concern in a magnetic resonance imaging environment is heating of metallic implants by absorbing radiofrequency (RF) energy during MRI scanning. Experimental measurement in conjunction with computational modeling was used to evaluate the risk of biological tissue injury from the RF heating of artificial hip joints by obtaining both specific absorption rate (SAR) and temperature elevation at 1.5 T and 3 T MRI systems. Simulation result showed that high SAR and high temperature appeared near both head and tail sections of the artificial hip joints. For five different 1.5 T and 3 T MRI systems, measured temperature location showed that high temperature rises occurred near both head and tail regions of the metallic hip joints. Measured SAR value of 24.6 W/kg and the high temperature rise (= 4.22 °C) occurred in the tail region of the hip joint at 1.5 T, which was higher than the limits for temperature required by the international electrotechnical commission 60601-2-33. We have demonstrated the feasibility of evaluating RF heating of metallic hip joints during MRI scans.


  • Open Access

    Reduction of bias in the evaluation of fractional anisotropy and mean diffusivity in magnetic resonance diffusion tensor imaging using region-of-interest methodology

    by Youngseob Seo, Nancy K. Rollins, Zhiyue J. Wang

    Accurate quantification of fractional anisotropy (FA) and mean diffusivity (MD) in MR diffusion tensor imaging (DTI) requires adequate signal-to-noise ratio (SNR) especially in low FA areas of the brain, which necessitates clinically impractical long image acquisition times. We explored a SNR enhancement strategy using region-of-interest (ROI)-based diffusion tensor for quantification. DTI scans from a healthy male were acquired 15 times and combined into sets with different number of signal averages (NSA = 1–4, 15) at one 1.5-T Philips and three 3-T (Philips, Siemens and GE) scanners. Equivalence test was performed to determine NSA thresholds for bias-free FA and MD quantifications by comparison with reference values derived from images with NSA = 15. We examined brain areas with low FA values including caudate nucleus, globus pallidus, putamen, superior temporal gyrus, and substructures within thalamus (lateral dorsal, ventral anterior and posterior nuclei), where bias-free FA is difficult to obtain using a conventional approach. Our results showed that bias-free FA can be obtained with NSA = 2 or 3 in some cases using ROI-based analysis. ROI-based analysis allows reliable FA and MD quantifications in various brain structures previously difficult to study with clinically feasible data acquisition schemes.


  • Open Access

    Correcting B0 Field Distortions in MRI Caused by Stainless Steel Orthodontic Appliances at 1.5 T Using Permanent Magnets – A Head Phantom Study

    by Zhiyue J. Wang, Yong Jong Park, Michael C. Morriss, Youngseob Seo, Trung Nguyen, Rami R. Hallac, Ana Nava, Rajiv Chopra, Yonatan Chatzinoff, Khyana Price, et al.

    Susceptibility artifacts caused by stainless steel orthodontic appliances (braces) pose significant challenges in clinical brain MRI examinations. We introduced field correction device (FCD) utilizing permanent magnets to cancel the induced B0inhomogeneity and mitigate geometric distortions in MRI. We evaluated a prototype FCD using a 3D-printed head phantom in this proof of concept study. The phantom was compartmented into anterior frontal lobe, temporal lobe, fronto-parieto-occipital lobe, basal ganglia and thalami, brain stem, and cerebellum and had built-in orthogonal gridlines to facilitate the quantification of geometric distortions and volume obliterations. Stainless steel braces were mounted on dental models of three different sizes with total induced magnetic moment 0.15 to 0.17 A·m2. With braces B0standard deviation (SD) ranged from 2.8 to 3.7 ppm in the temporal and anterior frontal lobes vs. 0.2 to 0.3 ppm without braces. The volume of brain regions in diffusion weighted imaging was obliterated by 32–38% with braces vs. 0% without braces in the cerebellum. With the FCD the SD of B0ranged from 0.3 to 1.2 ppm, and obliterated volume ranged from 0 to 6% in the corresponding brain areas. These results showed that FCD can effectively decrease susceptibility artifacts from orthodontic appliances.


  • High spatial resolution magnetic resonance imaging of insects covered with a hard exoskeleton

    by Youngseob Seo

    The morphological investigation of insects is usually performed using histologic serial sections and subsequent reconstruction of the structures from these sections. The achievement of cross sections for microtomy is time‐consuming and the risk of damaging sections is inevitable. Recently, X‐ray computed tomography (micro‐CT) was used to provide adequate spatial resolution without destroying the specimens. Micro‐CT is limited by the low x‐ray contrast of the insect soft tissues and image quality is relatively poor. Magnetic resonance imaging (MRI) allows the study of morphologic classification of the insects with sufficient spatial resolution and provides a noninvasive mean to determine disease abnormalities and progression in vivo and longitudinally. The morphologic classification of the insects with sufficient spatial resolution analyzed the potential of MR imaging. However, a stag beetle has a particularly hard exoskeleton protecting internal organs and nerves. It is challenge to obtain high spatial resolution images using MRI. The aim of this study was to characterize optimal MRI protocols for the investigation of stag beetles and to evaluate the morphologic characterization of the stag beetles by a 9.4 T MRI scanner. In this study, MR imaging provided the spatial resolution necessary for the examination of morphologic structures of the insects on our hardware‐software platform. This study plays a significant role in providing the high spatial resolution, ideally required for routine application to the study of internal morphology of insects, arachnids and crustaceans whose organs, nerves and muscles are protected by the hard exoskeleton.


  • Open Access

    Early detection of neonatal hypoxic–ischemic white matter injury

    by Youngseob Seo, Geun-Tae Kim, Jin Wook Choi

    The purpose of this study was to compare diffusion tensor metrics in normal age-matched neonates with survivors of hypoxic–ischemic encephalopathy (HIE) and extracorporeal membrane oxygenation (ECMO). Thirty-five normal, 27 HIE, and 13 ECMO infants underwent MRI at 3 T. Neurodevelopmental assessments were performed. Fractional anisotropy (FA), axial diffusivity (AD), and radial diffusivity (RD) of the inferior fronto-occipital fasciculus, inferior longitudinal fasciculus, anterior commissure, genu corpus callosum and splenium of the corpus callosum, anterior and posterior limb of the internal capsule, superior longitudinal fasciculus, and the centrum semiovale were analyzed with tract-based spatial statistics modified for use in neonates. Linear regression analysis was performed, and 95% confidence intervals were created for age effects on the tensor metrics with the control patients. Two-sample t-test was done to determine whether there was a difference in the tensor metrics between the normal and patient cohort. There was a statistically significant age effect on the FA and RD in the selected regions of the brain (F<0.05) and a group difference in the FA and RD between the normal and the HIE group (P<0.05). The group difference in the FA and RD between the normal and ECMO groups was seen in the anterior commissure, genu corpus callosum, right inferior longitudinal fasciculus, fronto-occipital fasciculus, centrum semiovale, and superior longitudinal fasciculus (P<0.05). Patients who were outside the 95% confidence intervals of the FA, AD, and RD overlapped with those with abnormalities clinically and on the conventional MRI. In conclusion, diffusion tensor imaging can play a significant role in detecting infants with early indications of hypoxic–ischemic brain injury. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/


  • Open Access

    MRI scanner‐independent specific absorption rate measurements using diffusion coefficients

    by Youngseob Seo, Zhiyue J. Wang

    Objective: The purpose of this study was to measure specific absorption rate (SAR) during MRI scanning using a human torso phantom through quantification of diffusion coefficients independently of those reported by the scanner software for five 1.5 and 3 T clinical MRI systems from different vendors.Methods: A quadrature body coil transmitted the RF power and a body array coil received the signals. With diffusion tensor imaging, SAR values for three MRI sequences were measured on the five scanners and compared to the nominal values calculated by the scanners.Results: For the GE 1.5 T MRI system, the MRI scanner‐reported SAR value was 1.58 W kg‐1 and the measured SAR value was 1.38 W kg‐1. For the Philips 1.5 T MRI scanner, the MRI system‐reported SAR value was 1.48 W kg‐1 and the measured value was 1.39 W kg‐1. For the Siemens 3 T MRI system, the reported SAR value was 2.5 W kg‐1 and the measured SAR value was 1.96 W kg‐1. For two Philips 3 T MRI scanners, the reported SAR values were 1.5 W kg‐1 and the measured values were 1.94 and 1.96 W kg‐1. The percentage differences between the measured and reported SAR values on the GE 1.5 T, Philips 1.5 T, Siemens 3 T, and Philips 3 T were 13.5, 6.3, 24.2, 25.6, and 26.6% respectively.Conclusion: The scanner‐independent SAR measurements using diffusion coefficients described in this study can play a significant role in estimating accurate SAR values as a standardized method.