CVCraig A. Velozo

Craig A. Velozo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Craig A. Velozo has a total of 62 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Short Forms and Computerized Adaptive Tests With Monosyllabic Words Can Efficiently Measure Speech Recognition

    by Bryant A. Seamon, Craig Salvador, Lois J. Mathews, Craig A. Velozo, Judy R. Dubno, Theodore R. McRackan

    Purpose: Construct validity of the Northwestern University Auditory Test No. 6 (NU-6) monosyllabic word lists or shortened versions have not been examined using the Rasch measurement theory. The study purposes were to test the fit of the Rasch measurement model to monosyllabic word lists and whether short forms and computerized adaptive testing can measure speech recognition. Method: A cross-sectional study design with 50 persons (average age = 71 years; 35 female, 15 male) with mild-to-moderate hearing loss was used to test the fit of NU-6 Word Lists 1 and 2 to the Rasch measurement model. Pearson's correlations quantified the accuracy of person measures from short forms or computer-adaptive testing simulations with measures from the full lists. Average standard error of person measures quantified measurement precision. Results: Word lists were unidimensional, had negligible misfit, and had high person reliability. Nineteen- and 11-word short forms were made per list. Person measures from 19-word short forms had a high linear association with person measures from the full word lists (List 1: r = .92, p < .0001, SE = 0.76; List 2: r = .91, p < .0001, SE = 0.74) compared to moderate association for the 11-word short form (List 1: r = .84, p < .0001, SE = 0.99; List 2: r = .81, p < .0001, SE = 0.97). Person measures from computerized adaptive testing simulation reached a correlation threshold, r > .90, after 15–20 words were administered for both lists. A precision-based stopping rule used an average of 18 (List 1) or 20 (List 2) words. Conclusion: Short forms with 19 words and computerized adaptive testing may accurately and precisely measure speech recognition.

  • Open Access

    Defining a universal measurement unit and scale for gross motor development

    by Bryant A. Seamon, Cynthia L. Sears, Emily Anderson, Craig A. Velozo

    Introduction: The ability of children to accomplish progressively more difficult gross motor tasks follows a predictable sequence that has been well documented as part of development. Current existing instruments were developed independently using classical test theory methods which led to the lack of a universal measurement scale and unit. The purpose of this study was to test a specification equation, anchored to commonly accepted and reproducible tasks in gross motor development, to generate a universal measurement scale and unit of measurement, called the Gross Motor (GM) unit.Methods: We rated component measures for each of the gross motor development tasks on the Gross Motor Function Measure-66 (GMFM). The GMFM is a gross motor development measure created with Rasch measurement theory to quantify observed difficulty levels measured on an interval scale. Component measures for body position, movement, and support were based on hypothesized contributions to gross motor development based on theory. Forward stepwise linear regression was used to test a specification equation. The specification equation was anchored to reference points to fix a unit size.Results: Our specification equation explained 87% of the variance in observed gross motor task difficulty. Predicted difficulty for gross motor tasks was strongly associated with observed task difficulty (r = 0.94, p < 0.0001). Our specification equation was anchored to 1) lying supine (0 GM units) and 2) walking unsupported (100 GM units) setting the size of the GM unit to 1/100 of the distance between lying supine and unsupported walking.Discussion: Our specification equation allows for experimental testing of gross motor development theories. This approach provides a framework for refining our understanding and measurement of gross motor development and creates a universal scale and unit. We expect that this will facilitate placing many, if not all, current gross motor development instruments on the same measurement scale.


  • Open Access

    Examining Older Adults’ Home Functioning Using the American Housing Survey

    by Mi Jung Lee, Daejin Kim, Sergio Romero, Ickpyo Hong, Nikolay Bliznyuk, Craig Velozo

    Identifying individuals at risk of experiencing functional difficulty at home would support timely home safety assessment and modification services, which could lead to reducing home incidents such as falls. The objective of this study was to calculate older adults’ functional difficulty at home scores using the 12 physical function items in the American Housing Survey National and Metropolitan Data (AHS). Among the 28,474 older adults selected for this study, we used 19,932 for measurement model development and 8542 for model testing. Confirmatory factor analysis confirmed an adequate fit of the one-dimensional model with all AHS 12 items loading on one latent construct (functional difficulty at home) (RMSEA: 0.034, CFI: 0.990, and TLI: 0.988). Based on our model selection process, we determined that the Graded Response Model was an optimal model for our analysis and separated two detected differential functioning items for each sex. Using the testing dataset, we validated that the estimated functional difficulty scores showed an expected item hierarchy and statistically significant differences in their association with housing and demographic conditions (p < 0.001). Our results demonstrated the process of using the 12 AHS physical function at home items to produce validated scores of older adults’ functional difficulty at home.


  • Open Access

    Effect of novel training to normalize altered finger force direction post-stroke: study protocol for a double-blind randomized controlled trial

    by Na Jin Seo, Derek G. Kamper, Viswanathan Ramakrishnan, Jillian B. Harvey, Christian Finetto, Christian Schranz, Gabrielle Scronce, Kristen Coupland, Keith Howard, Jenna Blaschke, et al.

    Background: Functional task performance requires proper control of both movement and force generation in three-dimensional space, especially for the hand. Control of force in three dimensions, however, is not explicitly treated in current physical rehabilitation. To address this gap in treatment, we have developed a tool to provide visual feedback on three-dimensional finger force. Our objective is to examine the effectiveness of training with this tool to restore hand function in stroke survivors. Methods: Double-blind randomized controlled trial. All participants undergo 18 1-h training sessions to practice generating volitional finger force of various target directions and magnitudes. The experimental group receives feedback on both force direction and magnitude, while the control group receives feedback on force magnitude only. The primary outcome is hand function as measured by the Action Research Arm Test. Other outcomes include the Box and Block Test, Stroke Impact Scale, ability to direct finger force, muscle activation pattern, and qualitative interviews. Discussion: The protocol for this clinical trial is described in detail. The results of this study will reveal whether explicit training of finger force direction in stroke survivors leads to improved motor control of the hand. This study will also improve the understanding of neuromuscular mechanisms underlying the recovery of hand function. Trial registration: ClinicalTrials.gov NCT03995069. Registered on June 21, 2019


  • Open Access

    Concomitant sensory stimulation during therapy to enhance hand functional recovery post stroke

    by Na Jin Seo, Viswanathan Ramakrishnan, Michelle L. Woodbury, Leonardo Bonilha, Christian Finetto, Christian Schranz, Gabrielle Scronce, Kristen Coupland, Jenna Blaschke, Adam Baker, et al.

    Background: Post-stroke hand impairment is prevalent and persistent even after a full course of rehabilitation. Hand diminishes stroke survivors’ abilities for activities of daily living and independence. One way to improve treatment efficacy is to augment therapy with peripheral sensory stimulation. Recently, a novel sensory stimulation, TheraBracelet, has been developed in which imperceptible vibration is applied during task practice through a wrist-worn device. The objective of this trial is to determine if combining TheraBracelet with hand task practice is superior to hand task practice alone. Methods: A double-blind randomized controlled trial will be used. Chronic stroke survivors will undergo a standardized hand task practice therapy program (3 days/week for 6 weeks) while wearing a device on the paretic wrist. The device will deliver TheraBracelet vibration for the treatment group and no vibration for the control group. The primary outcome is hand function measured by the Wolf Motor Function Test. Other outcomes include the Box and Block Test, Action Research Arm Test, upper extremity use in daily living, biomechanical measure of the sensorimotor grip control, and EEG-based neural communication. Discussion: This research will determine clinical utility of TheraBracelet to guide future translation. The TheraBracelet stimulation is delivered via a wrist-worn device, does not interfere with hand motion, and can be easily integrated into clinical practice. Enhancing hand function should substantially increase stroke survivors' independence and quality of life and reduce caregiver burden. Trial registration: NCT04569123. Registered on September 29, 2020


  • Using Measurement to Highlight Occupational Therapy's Distinct Value

    by Craig A. Velozo

    Traditional measurement approaches in health care focus on group data, virtually ignoring the individual client. To demonstrate the distinct value of occupational therapy, we need a measurement model that focuses on the person and generates outputs to inform daily practice. Traditional methods of establishing norms and predictive validity do not inform the development of interventions and goal setting. In this Eleanor Clarke Slagle Lecture, I use a person-centered measurement model that focuses on the person, versus the instrument, to demonstrate how person-centered measurement can be immediately used to identify the just-right challenge for the client. Person-centered measurement can be both the basis for designing interventions specific to the client and the foundation for setting empirically appropriate short-term and long-term goals. Occupational therapy practitioners can lead health care by immediately applying person-centered measurement to address the needs of individual clients and, moreover, to reveal the distinct value of occupational therapy.


  • Using Measurement to Highlight Occupational Therapy’s Distinct Value

    by Craig A. Velozo

    Traditional measurement approaches in health care focus on group data, virtually ignoring the individual client. To demonstrate the distinct value of occupational therapy, we need a measurement model that focuses on the person and generates outputs to inform daily practice. Traditional methods of establishing norms and predictive validity do not inform the development of interventions and goal setting. In this Eleanor Clarke Slagle Lecture, I use a person-centered measurement model that focuses on the person, versus the instrument, to demonstrate how person-centered measurement can be immediately used to identify the just-right challenge for the client. Person-centered measurement can be both the basis for designing interventions specific to the client and the foundation for setting empirically appropriate short-term and long-term goals. Occupational therapy practitioners can lead health care by immediately applying person-centered measurement to address the needs of individual clients and, moreover, to reveal the distinct value of occupational therapy.


  • Piloting an empirical approach to link the international classification of functioning, disability, and health to job demand classification

    by Chih-Ying Li, Paul B. Arthur, Ickpyo Hong, Craig A. Velozo

    The Social Security Administration has a thorough disability claims process, though one goal is to process claims more efficiently. This pilot described the creation and trial of a web-based tool to assist this process. To empirically link the International Classification of Functioning, Disability and Health (ICF) model to the Occupational Information Network (O*NET) with a self-reported activity measure (physical domain). ICF Activity domains and item difficulty calibrations were obtained from a self-reported ICF-Activity Measure. Three work/disability experts matched measurement constructs, job names, and item difficulties with job demands. Item difficulties were linked for "Positioning and Transfer" with O*NET data values of "Stamina"; "Trunk Strength", and "Walking and Moving" with O*NET data values of "Stamina." The system was then pilot tested with 14 adults with more than one activity challenges. An average total of 613 jobs were generated per participant and each job was categorized into one of 16 job clusters. Person ability measures and constructs were significant predictors for numbers of job (R2 = 0.92, p < 0.05). Participants demonstrated moderate satisfaction with program usability, and reported capability in performing jobs. The system provides a feasible means to assist disability examiners and claimants in identifying relevant job abilities and options.


  • FIM–Minimum Data Set Motor Item Bank: Short Forms Development and Precision Comparison in Veterans

    by Chih-Ying Li, Sergio Romero, Annie N. Simpson, Heather S. Bonilha, Kit N. Simpson, Ickpyo Hong, Craig A. Velozo