Christophe Aubrun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christophe Aubrun has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Shaikshavali Chitraganti
Department of Electrical Engineering, Indian Institute of Technology Palakkad, Palakkad, India
2 shared publications - Adel Tellili
Higher Institute of Technological Studies at Djerba (ISETJB)
1 shared publication Amina Challouf
Unité de recherche Modélisation, Analyse et Commande de Systèmes (MACS), Tunisia
1 shared publication- Boumedyen Boussaid
University of Gabes
1 shared publication D. Sauter
Centre de Recherche en Automatique de Nancy - CNRS UA 820 Université de NANCY 1 - Bd des Aiguillettes BP 239 - 54506 Vandoeuvre cedex - France
1 shared publicationDominique Sauter
University of Lorraine, CRAN -CNRS UMR 7039 BP239, 54506 Vandoeuvre Cedex, France
1 shared publication
Latest Publications
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 197-202
Design of fault isolation filter for control reconfiguration: Application to energy efficiency control in buildings
In this paper, fault adaptive control is developed for building Heating Ventilation and Air Conditioning (HVAC) systems. That is, the control system parameters and objective functions are adapted/reconfigured in the presence of a fault or performance deviation by means of an intermediate reconfigurable control layer. It allows maintaining building and HVAC operation within its specified energy and comfort performance requirements when a mechanical or operational fault takes place, until the fault is corrected. An integrated design, composed of two levels, respectively fault diagnosis and reconfiguration mechanism is proposed to recover performances after fault occurrence. This approach is applied to a 3 zones building and simulation results are given to show its effectiveness.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 197-202
Design of fault isolation filter for control reconfiguration: Application to energy efficiency control in buildings
In this paper, fault adaptive control is developed for building Heating Ventilation and Air Conditioning (HVAC) systems. That is, the control system parameters and objective functions are adapted/reconfigured in the presence of a fault or performance deviation by means of an intermediate reconfigurable control layer. It allows maintaining building and HVAC operation within its specified energy and comfort performance requirements when a mechanical or operational fault takes place, until the fault is corrected. An integrated design, composed of two levels, respectively fault diagnosis and reconfiguration mechanism is proposed to recover performances after fault occurrence. This approach is applied to a 3 zones building and simulation results are given to show its effectiveness.
- 1 December 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 405-410
Qualitative diagnosis of wind turbine system based on wavelet transform
In this paper we present a qualitative evaluation of generated residual signal using wavelet transform in purpose of fault diagnosis for wind turbine benchmark model. The fault detection is based on generating residual signal by comparing the real and an estimated behavior. The `Takagi-Sugeno' (TS) fuzzy identification and modeling is considered to approximate the non linearity presented in this system. Due to noise in the wind speed, the generated residual signal has to trade of the risk of false alarms to the risk of undetected faults. Occurrence of false alarms is largely dictated by the quality of the model of which the design of the Fault Detection and Isolation (FDI) system relies. Therefore, the proposed method using wavelet transform is considered to remedy the problem of false alarms. The treated signal of the residue with wavelet gives significant results which are validated with the wind turbine simulator.
- 1 December 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 405-410
Qualitative diagnosis of wind turbine system based on wavelet transform
In this paper we present a qualitative evaluation of generated residual signal using wavelet transform in purpose of fault diagnosis for wind turbine benchmark model. The fault detection is based on generating residual signal by comparing the real and an estimated behavior. The `Takagi-Sugeno' (TS) fuzzy identification and modeling is considered to approximate the non linearity presented in this system. Due to noise in the wind speed, the generated residual signal has to trade of the risk of false alarms to the risk of undetected faults. Occurrence of false alarms is largely dictated by the quality of the model of which the design of the Fault Detection and Isolation (FDI) system relies. Therefore, the proposed method using wavelet transform is considered to remedy the problem of false alarms. The treated signal of the residue with wavelet gives significant results which are validated with the wind turbine simulator.
- 1 December 2014
- Published by Elsevier in Systems & Control Letters
- Vol. 74, 81-89
On control of discrete-time state-dependent jump linear systems with probabilistic constraints: A receding horizon approach
- 1 December 2014
- Published by Elsevier in Systems & Control Letters
- Vol. 74, 81-89
On control of discrete-time state-dependent jump linear systems with probabilistic constraints: A receding horizon approach
- 1 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
AN adaptive fault tolerante control in interconnected systems
This work aims at the adaptive fault tolerant control using output feedback. Fault tolerant adaptive control is developed for N-interconnected subsystems with unknown sensors failures. Such sensors failures are characterized by some unknown inputs stuck at some unknown fixed values at unknown time instants. An effective output feedback controller structure is proposed for sensors failures compensation. The FTC scheme has an additive control in the adaptive controller which has an intrinsic robustness in terms of the stability and performance of the estimation sensors failure. This work is an extension of the additive control method presented in to the interconnected subsystems. Numerical and simulation results are provided to demonstrate the effectiveness of the proposed controller.
- 1 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
AN adaptive fault tolerante control in interconnected systems
This work aims at the adaptive fault tolerant control using output feedback. Fault tolerant adaptive control is developed for N-interconnected subsystems with unknown sensors failures. Such sensors failures are characterized by some unknown inputs stuck at some unknown fixed values at unknown time instants. An effective output feedback controller structure is proposed for sensors failures compensation. The FTC scheme has an additive control in the adaptive controller which has an intrinsic robustness in terms of the stability and performance of the estimation sensors failure. This work is an extension of the additive control method presented in to the interconnected subsystems. Numerical and simulation results are provided to demonstrate the effectiveness of the proposed controller.
- 1 June 1994
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 27 (5) , 95-98
On Line Reconfiguration Strategy of Control Law for Degraded Systems
- 1 June 1994
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 27 (5) , 95-98
On Line Reconfiguration Strategy of Control Law for Degraded Systems