Toru Kuboi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Toru Kuboi has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Akiko Nakano
National Hospital Organization Shikoku Medical Center for Children and Adults
5 shared publicationsSusumu Itoh
Kagawa University
5 shared publicationsTakaaki Sadamura
National Hospital Organization Shikoku Medical Center for Children and Adults
5 shared publications- Takashi Kusaka
Department of Pediatrics Faculty of Medicine Kagawa University Kagawa Japan
4 shared publications Hitoshi Okada
Department of Pediatrics, Faculty of Medicine Kagawa University Miki‐cho Japan
3 shared publications- Kaoru Okazaki
Department of Neonatology Tokyo Metropolitan Children's Medical Center Tokyo Japan
3 shared publications
Latest Publications
- 27 August 2025
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 63 (2) , 152-158
Quantitative effects of bilirubin photoisomers on the measurement of direct bilirubin by the enzymatic bilirubin oxidase method
Background: Bilirubin photoisomers, generated during phototherapy or incidental light exposure, may interfere with direct bilirubin (DB) measurement using the bilirubin oxidase method. This interference is particularly relevant in neonates, who physiologically exhibit elevated levels of unconjugated bilirubin. Methods: Residual serum samples from 30 neonates were irradiated under controlled conditions to selectively produce bilirubin configurational isomers (BCIs) and structural isomers (BSIs). DB and total bilirubin (TB) were measured pre- and post- irradiation using the bilirubin oxidase method. BCI and BSI concentrations were quantified using high-performance liquid chromatography (HPLC), and their contributions to DB values were evaluated using linear and multiple regression analyses. Results: Post-irradiation, DB levels increased significantly in correlation with BCI and BSI concentrations. Approximately 11% of BCI and 32% of BSI were quantified as DB using the bilirubin oxidase method. These findings were consistent across both individual and multiple regression models. Conclusions: Bilirubin photoisomers significantly influence DB values measured by the bilirubin oxidase method, potentially leading to overestimation of conjugated bilirubin. In neonatal care, accurate interpretation of DB values requires attention to sample handling and awareness of photoisomer interference, particularly under light-expose conditions.
- 27 August 2025
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 63 (2) , 152-158
Quantitative effects of bilirubin photoisomers on the measurement of direct bilirubin by the enzymatic bilirubin oxidase method
Background: Bilirubin photoisomers, generated during phototherapy or incidental light exposure, may interfere with direct bilirubin (DB) measurement using the bilirubin oxidase method. This interference is particularly relevant in neonates, who physiologically exhibit elevated levels of unconjugated bilirubin. Methods: Residual serum samples from 30 neonates were irradiated under controlled conditions to selectively produce bilirubin configurational isomers (BCIs) and structural isomers (BSIs). DB and total bilirubin (TB) were measured pre- and post- irradiation using the bilirubin oxidase method. BCI and BSI concentrations were quantified using high-performance liquid chromatography (HPLC), and their contributions to DB values were evaluated using linear and multiple regression analyses. Results: Post-irradiation, DB levels increased significantly in correlation with BCI and BSI concentrations. Approximately 11% of BCI and 32% of BSI were quantified as DB using the bilirubin oxidase method. These findings were consistent across both individual and multiple regression models. Conclusions: Bilirubin photoisomers significantly influence DB values measured by the bilirubin oxidase method, potentially leading to overestimation of conjugated bilirubin. In neonatal care, accurate interpretation of DB values requires attention to sample handling and awareness of photoisomer interference, particularly under light-expose conditions.
- 11 March 2025
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 62 (5) , 352-357
A multicenter study comparing a point-of-care blood glucose metre with a blood gas analyser in infants by the Shikoku Neonatal Medical Research Group
Background: There have been no reports on blood glucose metres for measurements in a wide variety of infant patients, from very preterm infants to mature infants and from the early neonatal period onwards. In this study, we evaluated the accuracy of the Glutest Mint II, a point-of-care blood glucose metre, by comparing blood glucose levels measured by this device with those measured by a blood gas analyser in infants of all gestational ages and birth weights at a number of time points after birth. Methods: Infants aged 22 weeks and 0 days of gestation or older who were born at any of six tertiary neonatal intensive care units between March 2022 and January 2023 and needed blood glucose monitoring were enrolled. Samples were collected into capillary tubes when the physician determined that a blood glucose test was necessary and could be taken at any time after birth and any number of times from the same individual. Blood glucose was measured using a Glutest Mint II and then using a blood gas analyser. Results: In total, 2943 blood glucose points were measured in 285 infants. Blood glucose levels measured using the Glutest Mint II were significantly correlated with those measured using a blood gas analyser. Neonatal-specific parameters such as hematocrit and total serum bilirubin levels may not have an effect. Conclusions: The Glutest Mint II device can measure blood glucose levels with very high accuracy in the range used in the neonatal setting, comparable to the blood gas analyser.
- 11 March 2025
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 62 (5) , 352-357
A multicenter study comparing a point-of-care blood glucose metre with a blood gas analyser in infants by the Shikoku Neonatal Medical Research Group
Background: There have been no reports on blood glucose metres for measurements in a wide variety of infant patients, from very preterm infants to mature infants and from the early neonatal period onwards. In this study, we evaluated the accuracy of the Glutest Mint II, a point-of-care blood glucose metre, by comparing blood glucose levels measured by this device with those measured by a blood gas analyser in infants of all gestational ages and birth weights at a number of time points after birth. Methods: Infants aged 22 weeks and 0 days of gestation or older who were born at any of six tertiary neonatal intensive care units between March 2022 and January 2023 and needed blood glucose monitoring were enrolled. Samples were collected into capillary tubes when the physician determined that a blood glucose test was necessary and could be taken at any time after birth and any number of times from the same individual. Blood glucose was measured using a Glutest Mint II and then using a blood gas analyser. Results: In total, 2943 blood glucose points were measured in 285 infants. Blood glucose levels measured using the Glutest Mint II were significantly correlated with those measured using a blood gas analyser. Neonatal-specific parameters such as hematocrit and total serum bilirubin levels may not have an effect. Conclusions: The Glutest Mint II device can measure blood glucose levels with very high accuracy in the range used in the neonatal setting, comparable to the blood gas analyser.
- 1 January 2025
- Published by Wiley in Pediatrics International
- Vol. 67 (1) , e70289
Safety of green LED phototherapy for neonatal hyperbilirubinemia: A randomized controlled trial
Background: Green light‐emitting diodes (LEDs) are still not widely used worldwide for neonatal hyperbilirubinemia, likely because their irradiance has not been properly evaluated and reports on their safety are scarce. We compared safety between green and blue LED phototherapy for the treatment of neonatal hyperbilirubinemia by using the alkaline comet assay method. Methods: This randomized controlled trial included 40 neonates with neonatal hyperbilirubinemia who were randomly allocated to green and blue LED phototherapy groups. Blood samples were obtained before and after 24 h of phototherapy in both groups. DNA damage was evaluated by alkaline comet assay. Total serum bilirubin (TSB) was measured using enzymatic methods. Results: The increases in % tail DNA after 24 h of phototherapy were not significantly different between the two groups. The TSB reduction was significantly greater in the green LED group than in the blue LED group ( p < 0.01). Conclusion: Green LED phototherapy appears to be reasonably safe in terms of DNA damage and shows a slightly greater effect in reducing serum bilirubin levels compared with blue LED phototherapy.
- 1 January 2025
- Published by Wiley in Pediatrics International
- Vol. 67 (1) , e70289
Safety of green LED phototherapy for neonatal hyperbilirubinemia: A randomized controlled trial
Background: Green light‐emitting diodes (LEDs) are still not widely used worldwide for neonatal hyperbilirubinemia, likely because their irradiance has not been properly evaluated and reports on their safety are scarce. We compared safety between green and blue LED phototherapy for the treatment of neonatal hyperbilirubinemia by using the alkaline comet assay method. Methods: This randomized controlled trial included 40 neonates with neonatal hyperbilirubinemia who were randomly allocated to green and blue LED phototherapy groups. Blood samples were obtained before and after 24 h of phototherapy in both groups. DNA damage was evaluated by alkaline comet assay. Total serum bilirubin (TSB) was measured using enzymatic methods. Results: The increases in % tail DNA after 24 h of phototherapy were not significantly different between the two groups. The TSB reduction was significantly greater in the green LED group than in the blue LED group ( p < 0.01). Conclusion: Green LED phototherapy appears to be reasonably safe in terms of DNA damage and shows a slightly greater effect in reducing serum bilirubin levels compared with blue LED phototherapy.
- 1 January 2023
- Published by Wiley in Pediatrics International
- Vol. 65 (1) , e15475
Multi‐phase appearance of congenital cutaneous Langerhans cell histiocytosis
- 1 January 2023
- Published by Wiley in Pediatrics International
- Vol. 65 (1) , e15475
Multi‐phase appearance of congenital cutaneous Langerhans cell histiocytosis
- 17 December 2021
- Published by Wiley in Pediatrics International
- Vol. 64 (1) , e14735
Furosemide clearance in very preterm neonates early in life: A pilot study using scavenged samples
Background: Furosemide is an off‐label drug, frequently used as a diuretic in neonates with oliguria and/or edema. Its clearance in preterm neonates is lower than in term neonates or children. We aimed, herein, to clarify furosemide clearance (CL) in very preterm (VP) neonates (<28 weeks’ gestation) within the first 2 weeks of life and identify the factors predictive of the pharmacokinetics (PK) parameters, such as CL. Methods: Furosemide was administered at 0.5 or 1 mg/kg in a 0.5‐h infusion via a syringe pump; blood samples were drawn from an artery or vein after the intravenous injection. The serum furosemide concentration was measured using high‐performance liquid chromatography. The PK parameters were then analyzed using Bayesian estimation. Results: Thirteen blood samples were obtained from 10 VP neonates after intravenous injection. The mean postconceptional age and mean postnatal days at exposure to furosemide were 26.9 weeks and 7.1 days, respectively. The estimated mean CL was 16.5 mL/kg/h. The mean distribution volume (Vd) and elimination half‐life (t1/2) were 0.37 L/kg and 15.3 h, respectively. Furosemide CL was negatively associated with serum creatinine (SCr) [CL = 84.2 – 67.1 × SCr (mg/dL)]. Conclusions: Very preterm neonates within the first 2 weeks of life had a higher CL than subjects in other preterm neonatal studies. The SCr level was the sole parameter influencing furosemide CL and might serve as a good index for furosemide dosing in VP neonates.
- 17 December 2021
- Published by Wiley in Pediatrics International
- Vol. 64 (1) , e14735
Furosemide clearance in very preterm neonates early in life: A pilot study using scavenged samples
Background: Furosemide is an off‐label drug, frequently used as a diuretic in neonates with oliguria and/or edema. Its clearance in preterm neonates is lower than in term neonates or children. We aimed, herein, to clarify furosemide clearance (CL) in very preterm (VP) neonates (<28 weeks’ gestation) within the first 2 weeks of life and identify the factors predictive of the pharmacokinetics (PK) parameters, such as CL. Methods: Furosemide was administered at 0.5 or 1 mg/kg in a 0.5‐h infusion via a syringe pump; blood samples were drawn from an artery or vein after the intravenous injection. The serum furosemide concentration was measured using high‐performance liquid chromatography. The PK parameters were then analyzed using Bayesian estimation. Results: Thirteen blood samples were obtained from 10 VP neonates after intravenous injection. The mean postconceptional age and mean postnatal days at exposure to furosemide were 26.9 weeks and 7.1 days, respectively. The estimated mean CL was 16.5 mL/kg/h. The mean distribution volume (Vd) and elimination half‐life (t1/2) were 0.37 L/kg and 15.3 h, respectively. Furosemide CL was negatively associated with serum creatinine (SCr) [CL = 84.2 – 67.1 × SCr (mg/dL)]. Conclusions: Very preterm neonates within the first 2 weeks of life had a higher CL than subjects in other preterm neonatal studies. The SCr level was the sole parameter influencing furosemide CL and might serve as a good index for furosemide dosing in VP neonates.
- Open Access
- 15 April 2021
- Published by BMJ in BMJ Case Reports
- Vol. 14 (4) , e238743
Maternal mesalazine-induced neonatal gastrointestinal bleeding
Ulcerative colitis often develops in the reproductive age women and can cause exacerbation by pregnancy. Mesalazine (5-aminosalicylic acid) is recommended as a safe anti-inflammatory drug during pregnancy. However, maternal mesalazine is transferred to the fetus through the placenta and may cause allergic events. A pregnant woman with severe ulcerative colitis was treated with a dose of mesalazine 4,000 mg/day from early gestation to delivery. Immediately after birth, the preterm neonate vomited bloody contents and discharged massive gross haematochezia. Serum concentrations of mesalazine and its main metabolite were high in the mother and the umbilical cord. Faecal eosinophils and drug-induced lymphocyte stimulation test suggested possibility that sensitisation with mesalazine in utero caused allergic enterocolitis like food protein-induced allergic proctocolitis. Maternal mesalazine has a potential of fetal sensitisation and cause allergic disease.
- 15 April 2021
- Published by BMJ in BMJ Case Reports
- Vol. 14 (4) , e238743
Open AccessMaternal mesalazine-induced neonatal gastrointestinal bleeding
Ulcerative colitis often develops in the reproductive age women and can cause exacerbation by pregnancy. Mesalazine (5-aminosalicylic acid) is recommended as a safe anti-inflammatory drug during pregnancy. However, maternal mesalazine is transferred to the fetus through the placenta and may cause allergic events. A pregnant woman with severe ulcerative colitis was treated with a dose of mesalazine 4,000 mg/day from early gestation to delivery. Immediately after birth, the preterm neonate vomited bloody contents and discharged massive gross haematochezia. Serum concentrations of mesalazine and its main metabolite were high in the mother and the umbilical cord. Faecal eosinophils and drug-induced lymphocyte stimulation test suggested possibility that sensitisation with mesalazine in utero caused allergic enterocolitis like food protein-induced allergic proctocolitis. Maternal mesalazine has a potential of fetal sensitisation and cause allergic disease.
- 5 March 2019
- Published by Wiley in Pediatrics International
- Vol. 61 (5) , 465-470
Green light‐emitting diode phototherapy for neonatal hyperbilirubinemia: Randomized controlled trial
Background: The main photochemical pathway in phototherapy for neonatal hyperbilirubinemia is the production and elimination (in bile or urine) of cyclobilirubin, which is a structural photoisomer of bilirubin, and which is most efficiently produced by green light. Green light‐emitting diode (LED) phototherapy, however, has not been evaluated in the clinical setting because it is not recommended in American Academy of Pediatrics guidelines. We therefore compared the efficacy of green LED phototherapy and blue LED phototherapy in patients with neonatal hyperbilirubinemia.Methods: In this prospective randomized controlled trial, neonates with hyperbilirubinemia were randomly allocated to a green LED or blue LED phototherapy group. Both groups underwent 24 h of phototherapy, and blood was sampled before and after 24 h of phototherapy. Total serum bilirubin (TSB) was measured using enzymatic methods and bilirubin photoisomers were measured on high‐performance liquid chromatography.Results: Thirty‐four infants were randomized (green, n = 16; blue, n = 18). TSB decreased significantly from 15.3 ± 1.5 to 13.9 ± 1.5 mg/dL in the green LED group (P < 0.01) and from 16.2 ± 1.3 to 14.5 ± 1.7 mg/dL in the blue LED group (P < 0.01) after 24 h of phototherapy. No significant difference was found in TSB reduction after phototherapy between the groups.Conclusions: Both light sources produced a significant reduction in TSB, indicating clinical effectiveness.
- 5 March 2019
- Published by Wiley in Pediatrics International
- Vol. 61 (5) , 465-470
Green light‐emitting diode phototherapy for neonatal hyperbilirubinemia: Randomized controlled trial
Background: The main photochemical pathway in phototherapy for neonatal hyperbilirubinemia is the production and elimination (in bile or urine) of cyclobilirubin, which is a structural photoisomer of bilirubin, and which is most efficiently produced by green light. Green light‐emitting diode (LED) phototherapy, however, has not been evaluated in the clinical setting because it is not recommended in American Academy of Pediatrics guidelines. We therefore compared the efficacy of green LED phototherapy and blue LED phototherapy in patients with neonatal hyperbilirubinemia.Methods: In this prospective randomized controlled trial, neonates with hyperbilirubinemia were randomly allocated to a green LED or blue LED phototherapy group. Both groups underwent 24 h of phototherapy, and blood was sampled before and after 24 h of phototherapy. Total serum bilirubin (TSB) was measured using enzymatic methods and bilirubin photoisomers were measured on high‐performance liquid chromatography.Results: Thirty‐four infants were randomized (green, n = 16; blue, n = 18). TSB decreased significantly from 15.3 ± 1.5 to 13.9 ± 1.5 mg/dL in the green LED group (P < 0.01) and from 16.2 ± 1.3 to 14.5 ± 1.7 mg/dL in the blue LED group (P < 0.01) after 24 h of phototherapy. No significant difference was found in TSB reduction after phototherapy between the groups.Conclusions: Both light sources produced a significant reduction in TSB, indicating clinical effectiveness.
- 21 January 2018
- Published by Wiley in Pediatrics International
- Vol. 60 (1) , 98-99
Congenital abdominal aortic aneurysm discovered incidental to a lower back mass
- 21 January 2018
- Published by Wiley in Pediatrics International
- Vol. 60 (1) , 98-99
Congenital abdominal aortic aneurysm discovered incidental to a lower back mass
- Open Access
- 7 August 2017
- Published by Wiley in Pediatrics International
- Vol. 59 (9) , 959-966
Phototherapy for neonatal hyperbilirubinemia
Approximately 60 years ago in England, phototherapy for neonatal hyperbilirubinemia was used in clinical practice. It was introduced in Japan approximately 50 years ago. At that time, the mechanism underlying the serum bilirubin concentration decrease by phototherapy was still unknown. The mechanism was identified by chemists, biochemists, and pediatricians. Clarification started with the report that unconjugated bilirubin was excreted into bile after photoirradiation in Gunn rats. After confirmation of the molecular structure of bilirubin on X‐ray analysis, the mechanism for bile excretion of unconjugated bilirubin was verified based on geometric configurational photoisomers in the Gunn rat. Finally, the reaction and excretion of structural bilirubin photoisomers was proved to be the main mechanism for the decrease in serum bilirubin during phototherapy for neonatal hyperbilirubinemia, which differs from the mechanism in the Gunn rat. The most effective and safest light source and the optimal method to evaluate phototherapy, however, remain unknown. Moreover, as for bronze baby syndrome, which is a well‐known adverse reaction to phototherapy, the etiology is unclear. Hence, we review phototherapy for hyperbilirubinemia including a fundamental understanding of the bilirubin photochemical reactions, and discuss the subclinical carcinogenic risk of phototherapy and the increased mortality rate of extremely low‐birthweight infants due to aggressive phototherapy, which is becoming an increasing problem.
- 7 August 2017
- Published by Wiley in Pediatrics International
- Vol. 59 (9) , 959-966
Open AccessPhototherapy for neonatal hyperbilirubinemia
Approximately 60 years ago in England, phototherapy for neonatal hyperbilirubinemia was used in clinical practice. It was introduced in Japan approximately 50 years ago. At that time, the mechanism underlying the serum bilirubin concentration decrease by phototherapy was still unknown. The mechanism was identified by chemists, biochemists, and pediatricians. Clarification started with the report that unconjugated bilirubin was excreted into bile after photoirradiation in Gunn rats. After confirmation of the molecular structure of bilirubin on X‐ray analysis, the mechanism for bile excretion of unconjugated bilirubin was verified based on geometric configurational photoisomers in the Gunn rat. Finally, the reaction and excretion of structural bilirubin photoisomers was proved to be the main mechanism for the decrease in serum bilirubin during phototherapy for neonatal hyperbilirubinemia, which differs from the mechanism in the Gunn rat. The most effective and safest light source and the optimal method to evaluate phototherapy, however, remain unknown. Moreover, as for bronze baby syndrome, which is a well‐known adverse reaction to phototherapy, the etiology is unclear. Hence, we review phototherapy for hyperbilirubinemia including a fundamental understanding of the bilirubin photochemical reactions, and discuss the subclinical carcinogenic risk of phototherapy and the increased mortality rate of extremely low‐birthweight infants due to aggressive phototherapy, which is becoming an increasing problem.
- 1 May 2016
- Published by Elsevier in Journal of Infection and Chemotherapy
- Vol. 22 (5) , 339-341
A case of cutaneous Paecilomyces formosus infection in an extremely premature infant
- 1 May 2016
- Published by Elsevier in Journal of Infection and Chemotherapy
- Vol. 22 (5) , 339-341
A case of cutaneous Paecilomyces formosus infection in an extremely premature infant