Behzad B. Pavri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Behzad B. Pavri has a total of 158 co-authors. Here are the top co-authors by number of shared publications:
- Reginald T. Ho
Department of Medicine, Division of Cardiology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA
8 shared publications - Arnold J. Greenspon
Division of Cardiology, Department of Medicine, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania
5 shared publications - Daniel Robert Frisch
Department of Medicine Rutgers Robert Wood Johnson Medical School New Brunswick NJ
4 shared publications Anand S. Kenia
Thomas Jefferson University Hospital, Philadelphia, Pennsylvania
2 shared publicationsCraig W. Raphael
Department of Medicine, Division of Cardiology Thomas Jefferson University Hospital Philadelphia Pennsylvania USA
2 shared publicationsEitan Frankel
Division of Cardiology, Department of Medicine, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania
2 shared publications
Latest Publications
- Open Access
- 27 April 2026
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 42 (8) , 1-10
Mitral annular disjunction and mitral valve prolapse: echocardiographic-MRI insights into cardiac function
Background : Mitral annular disjunction (MAD) may accompany mitral valve prolapse (MVP) and is linked to ventricular arrhythmias. Its impact on global cardiac performance (specifically cardiac index (CI) and output (CO)), remains incompletely defined. Cardiac MRI (CMR) allows precise measurement of MAD, assessment of mitral annular dynamics, and detection of myocardial fibrosis via late gadolinium enhancement (LGE). We investigated both CMR and TTE metrics in patients with varying degrees of MAD compared to MVP-only. Methods and results : Fifty-six patients who underwent CMR and TTE (mean age 61, 33 female) were divided into MAD ≥2 mm and MVP (the “MAD + MVP” group, n = 41) or MVP-only (n = 15). MAD was classified as Conclusion : MAD is associated with impaired cardiac performance independent of MR and with increased myocardial fibrosis in severe cases. These findings suggest heightened electromechanical stress in MAD compared to MVP-only, which needs to be clinically correlated. TTE reliably detects and quantifies MAD, supporting its use alongside CMR for assessment of MAD.
- 27 April 2026
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 42 (8) , 1-10
Open AccessMitral annular disjunction and mitral valve prolapse: echocardiographic-MRI insights into cardiac function
Background : Mitral annular disjunction (MAD) may accompany mitral valve prolapse (MVP) and is linked to ventricular arrhythmias. Its impact on global cardiac performance (specifically cardiac index (CI) and output (CO)), remains incompletely defined. Cardiac MRI (CMR) allows precise measurement of MAD, assessment of mitral annular dynamics, and detection of myocardial fibrosis via late gadolinium enhancement (LGE). We investigated both CMR and TTE metrics in patients with varying degrees of MAD compared to MVP-only. Methods and results : Fifty-six patients who underwent CMR and TTE (mean age 61, 33 female) were divided into MAD ≥2 mm and MVP (the “MAD + MVP” group, n = 41) or MVP-only (n = 15). MAD was classified as Conclusion : MAD is associated with impaired cardiac performance independent of MR and with increased myocardial fibrosis in severe cases. These findings suggest heightened electromechanical stress in MAD compared to MVP-only, which needs to be clinically correlated. TTE reliably detects and quantifies MAD, supporting its use alongside CMR for assessment of MAD.
- 22 December 2025
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 11 (12) , 2772
There Is a Link Between Ventricular Pre-Excitation and Long QT Syndrome-Related Arrhythmias
- 22 December 2025
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 11 (12) , 2772
There Is a Link Between Ventricular Pre-Excitation and Long QT Syndrome-Related Arrhythmias
- Open Access
- 18 October 2025
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 25 (5) , 374-378
Jumps and concealed conduction: Interactions between a manifest anteroseptal accessory pathway and the fast and slow pathways of the atrioventricular node
- 18 October 2025
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 25 (5) , 374-378
Open AccessJumps and concealed conduction: Interactions between a manifest anteroseptal accessory pathway and the fast and slow pathways of the atrioventricular node
- Open Access
- 16 July 2025
- Published by Wiley
Cardiac Resynchronization Therapy in Heart Failure with Preserved Ejection Fraction in the Setting of Left Bundle Branch Block and Dyssynchrony: A Comprehensive Review
Heart failure with preserved ejection fraction (HFpEF) remains a complex and therapeutically challenging syndrome. A subset of HFpEF patients with left bundle branch block (LBBB), wide QRS complexes (≥130 ms), and mechanical dyssynchrony may benefit from cardiac resynchronization therapy (CRT). While CRT is an established therapy in heart failure with reduced ejection fraction (HFrEF), its role in HFpEF is under active investigation. Emerging data from mechanistic studies, case reports, and observational trials suggest CRT may offer promising hemodynamic signals, functional improvement, and quality of life enhancement in carefully selected HFpEF patients. This review critically examines the pathophysiological rationale, evolving evidence base, patient selection criteria, and future directions for CRT in HFpEF with LBBB.
- 16 July 2025
- Published by Wiley
Open AccessCardiac Resynchronization Therapy in Heart Failure with Preserved Ejection Fraction in the Setting of Left Bundle Branch Block and Dyssynchrony: A Comprehensive Review
Heart failure with preserved ejection fraction (HFpEF) remains a complex and therapeutically challenging syndrome. A subset of HFpEF patients with left bundle branch block (LBBB), wide QRS complexes (≥130 ms), and mechanical dyssynchrony may benefit from cardiac resynchronization therapy (CRT). While CRT is an established therapy in heart failure with reduced ejection fraction (HFrEF), its role in HFpEF is under active investigation. Emerging data from mechanistic studies, case reports, and observational trials suggest CRT may offer promising hemodynamic signals, functional improvement, and quality of life enhancement in carefully selected HFpEF patients. This review critically examines the pathophysiological rationale, evolving evidence base, patient selection criteria, and future directions for CRT in HFpEF with LBBB.
- Open Access
- 7 July 2025
- Published by Wiley in Journal of Arrhythmia
- Vol. 41 (4) , e70133
Differing impacts of cardiac implantable electronic device leads on tricuspid regurgitation
Background: Placement of cardiac implantable electronic devices (CIED) with leads that traverse the tricuspid valve is thought to contribute to tricuspid regurgitation (TR). However, there are relatively limited data comparing the impact of different CIED lead types on the incidence and progression of TR. This study sought to quantify the change in TR severity following implantation of CIEDs with different lead types. Methods: Patient data were collected on individuals with implantable cardioverter defibrillators (ICD), right ventricular‐paced pacemakers (RV‐PM), and His bundle‐paced pacemakers (His‐PM) placed by a single provider at a single institution between 2016 and 2019. Patients with extravascular CIED placement or with existing devices undergoing upgrade procedures were excluded. Severity of TR after CIED implantation was compared to baseline TR. Results: A total of 97 patients receiving CIEDs were analyzed, including 63 with RV‐PMs, 23 with ICDs, and 11 with His‐PMs. Median patient age was 72 [interquartile range (IQR) 63–81] years, and 44% of patients were female. Echocardiograms were obtained a median of 20 [4–91] days before CIED implantation and 31 [17.9–43.0] months following implantation. Baseline TR grade was comparable between groups ( p = 0.65). TR severity significantly worsened after ICD implantation ( p = 0.035), RV‐PM implantation trended toward worsening TR severity ( p = 0.099), and no statistically significant difference was observed after His‐PM implantation ( p = 0.68). Conclusion: The effect of CIED leads on TR represents a spectrum related to the type of lead traversing the tricuspid valve.
- 7 July 2025
- Published by Wiley in Journal of Arrhythmia
- Vol. 41 (4) , e70133
Open AccessDiffering impacts of cardiac implantable electronic device leads on tricuspid regurgitation
Background: Placement of cardiac implantable electronic devices (CIED) with leads that traverse the tricuspid valve is thought to contribute to tricuspid regurgitation (TR). However, there are relatively limited data comparing the impact of different CIED lead types on the incidence and progression of TR. This study sought to quantify the change in TR severity following implantation of CIEDs with different lead types. Methods: Patient data were collected on individuals with implantable cardioverter defibrillators (ICD), right ventricular‐paced pacemakers (RV‐PM), and His bundle‐paced pacemakers (His‐PM) placed by a single provider at a single institution between 2016 and 2019. Patients with extravascular CIED placement or with existing devices undergoing upgrade procedures were excluded. Severity of TR after CIED implantation was compared to baseline TR. Results: A total of 97 patients receiving CIEDs were analyzed, including 63 with RV‐PMs, 23 with ICDs, and 11 with His‐PMs. Median patient age was 72 [interquartile range (IQR) 63–81] years, and 44% of patients were female. Echocardiograms were obtained a median of 20 [4–91] days before CIED implantation and 31 [17.9–43.0] months following implantation. Baseline TR grade was comparable between groups ( p = 0.65). TR severity significantly worsened after ICD implantation ( p = 0.035), RV‐PM implantation trended toward worsening TR severity ( p = 0.099), and no statistically significant difference was observed after His‐PM implantation ( p = 0.68). Conclusion: The effect of CIED leads on TR represents a spectrum related to the type of lead traversing the tricuspid valve.
- 19 May 2025
- Published by Elsevier in Heart Rhythm
- Vol. 23 (5) , 1204-1211
S/QRS ratio in lead I: A surface electrocardiographic finding associated with need for permanent pacemaker in patients with right bundle branch block
- 19 May 2025
- Published by Elsevier in Heart Rhythm
- Vol. 23 (5) , 1204-1211
S/QRS ratio in lead I: A surface electrocardiographic finding associated with need for permanent pacemaker in patients with right bundle branch block
- Open Access
- 3 April 2025
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 30 (3) , e70069
Serendipitous Supernormality
We describe a patient who underwent AV node modification to create complete heart block in the setting of incessant, ablation‐and‐drug‐refractory, symptomatic atypical atrial flutter. His dual chamber defibrillator (previously implanted for resuscitated cardiac arrest) was programmed to the VVIR mode at a faster pacing rate of 85 bpm. Serendipitously, this rate was an almost exact factorial of his flutter rate of 250–260 bpm. This resulted in every 6th flutter wave falling in the supernormal period, resulting in fixed‐coupled supraventricular bigeminy and trigeminy in the setting of complete heart block. Reprogramming the pacing rate to 75 bpm abolished bigeminy and trigeminy.
- 3 April 2025
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 30 (3) , e70069
Open AccessSerendipitous Supernormality
We describe a patient who underwent AV node modification to create complete heart block in the setting of incessant, ablation‐and‐drug‐refractory, symptomatic atypical atrial flutter. His dual chamber defibrillator (previously implanted for resuscitated cardiac arrest) was programmed to the VVIR mode at a faster pacing rate of 85 bpm. Serendipitously, this rate was an almost exact factorial of his flutter rate of 250–260 bpm. This resulted in every 6th flutter wave falling in the supernormal period, resulting in fixed‐coupled supraventricular bigeminy and trigeminy in the setting of complete heart block. Reprogramming the pacing rate to 75 bpm abolished bigeminy and trigeminy.
- Open Access
- 1 January 2025
- Published by Thomas Jefferson University
- Vol. 26 (1) , 15
A Shock to the Heart? A Case of Phantom Shocks in a Patient with Brugada Syndrome
Brugada syndrome is an inherited condition characterized by an increased risk of sudden cardiac death (SCD) secondary to lethal ventricular arrhythmias occurring most often in the fourth decade of life. Implantable cardioverter-defibrillators (ICDs) are recommended in patients who have documented ventricular tachycardia (VT) or ventricular fibrillation (VF) and in patients presenting with a spontaneous type 1 Brugada pattern on electrocardiogram (ECG) and a history of arrhythmic-sounding syncope.1 However, patients with ICDs are at risk of developing “phantom shocks” which occur when a patient reports the sensation of receiving a shock that is not confirmed upon subsequent device interrogation.2 One retrospective study of 38 patients demonstrated that patients who reported phantom shocks had a higher prevalence of documented depression, anxiety and substance use and that patients who had previous ICD shocks for “arrhythmia storm” were more likely to experience phantom shocks.3 Prior studies have described the increased incidence of anxiety and decreased quality of life in patients diagnosed with Brugada syndrome alone with some patients developing post-traumatic stress disorder (PTSD).4 We present a case of a patient with previously diagnosed Brugada syndrome who suffered from phantom shocks after a defibrillation event. This case highlights the importance of recognizing phantom shocks for improving patient outcomes, to provide a multidisciplinary approach and to optimize both cardiac and psychological well-being of these patients.
- 1 January 2025
- Published by Thomas Jefferson University
- Vol. 26 (1) , 15
Open AccessA Shock to the Heart? A Case of Phantom Shocks in a Patient with Brugada Syndrome
Brugada syndrome is an inherited condition characterized by an increased risk of sudden cardiac death (SCD) secondary to lethal ventricular arrhythmias occurring most often in the fourth decade of life. Implantable cardioverter-defibrillators (ICDs) are recommended in patients who have documented ventricular tachycardia (VT) or ventricular fibrillation (VF) and in patients presenting with a spontaneous type 1 Brugada pattern on electrocardiogram (ECG) and a history of arrhythmic-sounding syncope.1 However, patients with ICDs are at risk of developing “phantom shocks” which occur when a patient reports the sensation of receiving a shock that is not confirmed upon subsequent device interrogation.2 One retrospective study of 38 patients demonstrated that patients who reported phantom shocks had a higher prevalence of documented depression, anxiety and substance use and that patients who had previous ICD shocks for “arrhythmia storm” were more likely to experience phantom shocks.3 Prior studies have described the increased incidence of anxiety and decreased quality of life in patients diagnosed with Brugada syndrome alone with some patients developing post-traumatic stress disorder (PTSD).4 We present a case of a patient with previously diagnosed Brugada syndrome who suffered from phantom shocks after a defibrillation event. This case highlights the importance of recognizing phantom shocks for improving patient outcomes, to provide a multidisciplinary approach and to optimize both cardiac and psychological well-being of these patients.
- Open Access
Reimagining Cryptogenic Stroke Care: Collaborative Care and Inpatient Insertable Cardiac Monitors for Detection of Atrial Fibrillation
Background: Atrial fibrillation (AF) is a known risk factor of ischemic stroke and AF-related stroke is twice more likely to be fatal. Long-term cardiac rhythm monitoring using insertable cardiac monitors (ICMs) has greater diagnostic yield compared to conventional monitoring in detecting AF, and clinical utility of ICMs is established in cryptogenic stroke, strokes due to large artery atherosclerosis and small vessel disease. A registry-based study was conducted to evaluate inpatient implantation of ICMs and feasibility of vascular and interventional neurologists as implanters using novel collaborative clinical care pathway for cryptogenic stroke. Methods: Multiyear data from a hospital-based registry at a comprehensive stroke center was reviewed to evaluate inpatient ICM implantation and test feasibility of vascular and interventional neurologists/VIN as implanters of ICMs together with cardiology using a novel collaborative care pathway. Reviewed data included number of ICMs, implantation trend, inpatient vs. outpatient setting, time to ICM implantation, inpatient workflow including defined roles of team members, and AF detection rate. Results: Total of 290 ICMs for cryptogenic stroke were implanted when patients where in the hospital and 78 as outpatient after discharge during the study period of 3 years. The majority of inpatient ICM implants were performed by VIN (n=181) and ICM use for cryptogenic stroke increased by 130%. Average time to inpatient ICM implant was 4.1 days with 77% in 5 and 95.5% within 10 days post-stroke. Average time to out-patient ICM placement was 57 days. AF detection rate of 36.5% was noted at 24 months with a collaborative care pathway. Discussion: Inpatient implantation of ICMs is feasible and was performed safely and efficiently by VIN together with cardiology using a collaborative care pathway. Increase in utilization of ICMs and higher AF detection rates were noted. Findings support innovative efforts to improve access and close the gaps in delivery of cryptogenic stroke care to ultimately reduce the secondary stroke burden. Clinical Perspective: Direct inpatient implantation of ICMs in cryptogenic stroke allows increased rates of early long-term cardiac rhythm monitoring and detection of AF. Collaborative clinical practice with inpatient ICM implantation by vascular and interventional neurologists is feasible and safe. This novel approach could potentially increase access to cardiac rhythm monitoring and exemplify patient-centered care.
Open AccessReimagining Cryptogenic Stroke Care: Collaborative Care and Inpatient Insertable Cardiac Monitors for Detection of Atrial Fibrillation
Background: Atrial fibrillation (AF) is a known risk factor of ischemic stroke and AF-related stroke is twice more likely to be fatal. Long-term cardiac rhythm monitoring using insertable cardiac monitors (ICMs) has greater diagnostic yield compared to conventional monitoring in detecting AF, and clinical utility of ICMs is established in cryptogenic stroke, strokes due to large artery atherosclerosis and small vessel disease. A registry-based study was conducted to evaluate inpatient implantation of ICMs and feasibility of vascular and interventional neurologists as implanters using novel collaborative clinical care pathway for cryptogenic stroke. Methods: Multiyear data from a hospital-based registry at a comprehensive stroke center was reviewed to evaluate inpatient ICM implantation and test feasibility of vascular and interventional neurologists/VIN as implanters of ICMs together with cardiology using a novel collaborative care pathway. Reviewed data included number of ICMs, implantation trend, inpatient vs. outpatient setting, time to ICM implantation, inpatient workflow including defined roles of team members, and AF detection rate. Results: Total of 290 ICMs for cryptogenic stroke were implanted when patients where in the hospital and 78 as outpatient after discharge during the study period of 3 years. The majority of inpatient ICM implants were performed by VIN (n=181) and ICM use for cryptogenic stroke increased by 130%. Average time to inpatient ICM implant was 4.1 days with 77% in 5 and 95.5% within 10 days post-stroke. Average time to out-patient ICM placement was 57 days. AF detection rate of 36.5% was noted at 24 months with a collaborative care pathway. Discussion: Inpatient implantation of ICMs is feasible and was performed safely and efficiently by VIN together with cardiology using a collaborative care pathway. Increase in utilization of ICMs and higher AF detection rates were noted. Findings support innovative efforts to improve access and close the gaps in delivery of cryptogenic stroke care to ultimately reduce the secondary stroke burden. Clinical Perspective: Direct inpatient implantation of ICMs in cryptogenic stroke allows increased rates of early long-term cardiac rhythm monitoring and detection of AF. Collaborative clinical practice with inpatient ICM implantation by vascular and interventional neurologists is feasible and safe. This novel approach could potentially increase access to cardiac rhythm monitoring and exemplify patient-centered care.
- Open Access
- 17 May 2024
- Published by Wiley
Evaluating YouTube Videos as a High-Quality Educational Resource for Patients Contemplating Receiving Implantable Cardioverter Defibrillators
Introduction Patients increasingly use online sources to research treatment options and YouTube is the most used online video source. An estimated 40% of Americans watch YouTube videos regarding health and medicine; however, YouTube is unregulated and non-peer-reviewed. Methods We searched for YouTube videos using the term “Implantable Cardioverter Defibrillator.” Videos were categorized by uploader type and assessed using two methodologies: the modified DISCERN criteria (range: 0-25) and an electrophysiologist-reviewed Novel ICD (NI) score (range: 0-10). Qualitative score cut-offs were implemented stratifying the videos as: very poor, poor, average, good, and excellent. Secondary outcomes such as measures of popularity, duration, and audio-visual quality were collected and analyzed. Results Overall video quality was poor and highly variable across both scoring systems: mean modified DISCERN = 13.19±5.12; mean NI score = 4.09±2.56. Videos uploaded from academic institutions had a significantly higher modified DISCERN score than medical device companies, 13.97 (±4.59) vs. 9.039 (±5.16) (p=0.011). A significant positive correlation was found between video duration and both NI score (r=0.77, p<0.001) and modified DISCERN criteria (r=0.57, p<0.001). None of the metrics of video popularity correlated with video quality. Conclusion YouTube videos regarding ICDs available to patients were of a low and highly-variable quality. Factors such as uploader type, duration, and search position correlated with video quality. Although longer videos were more informative, videos that were optimal in length for attention (6 to 9 minutes) were variable in quality. More popular videos were not of higher quality, indicating that video preference by patients can be flawed.
- 17 May 2024
- Published by Wiley
Open AccessEvaluating YouTube Videos as a High-Quality Educational Resource for Patients Contemplating Receiving Implantable Cardioverter Defibrillators
Introduction Patients increasingly use online sources to research treatment options and YouTube is the most used online video source. An estimated 40% of Americans watch YouTube videos regarding health and medicine; however, YouTube is unregulated and non-peer-reviewed. Methods We searched for YouTube videos using the term “Implantable Cardioverter Defibrillator.” Videos were categorized by uploader type and assessed using two methodologies: the modified DISCERN criteria (range: 0-25) and an electrophysiologist-reviewed Novel ICD (NI) score (range: 0-10). Qualitative score cut-offs were implemented stratifying the videos as: very poor, poor, average, good, and excellent. Secondary outcomes such as measures of popularity, duration, and audio-visual quality were collected and analyzed. Results Overall video quality was poor and highly variable across both scoring systems: mean modified DISCERN = 13.19±5.12; mean NI score = 4.09±2.56. Videos uploaded from academic institutions had a significantly higher modified DISCERN score than medical device companies, 13.97 (±4.59) vs. 9.039 (±5.16) (p=0.011). A significant positive correlation was found between video duration and both NI score (r=0.77, p<0.001) and modified DISCERN criteria (r=0.57, p<0.001). None of the metrics of video popularity correlated with video quality. Conclusion YouTube videos regarding ICDs available to patients were of a low and highly-variable quality. Factors such as uploader type, duration, and search position correlated with video quality. Although longer videos were more informative, videos that were optimal in length for attention (6 to 9 minutes) were variable in quality. More popular videos were not of higher quality, indicating that video preference by patients can be flawed.