Jinhua Dong
Research Subjects
Jinhua Dong has a total of 145 co-authors. Here are the top co-authors by number of shared publications:
- Hiroshi Ueda
Laboratory for Chemistry and Life Science, Institute of Integrated Research, Institute of Science Tokyo, 4259 Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa 226-8501, Japan
33 shared publications - Enoch Y. Park
Shizuoka University
9 shared publications - Tatsuya Kato
Molecular and Biological Function Research Core, Research Institute of Green Science and Technology, Shizuoka University, Shizuoka, Japan
7 shared publications Haimei Li
School of Life Science and Technology, Weifang Medical University, Weifang, China
6 shared publicationsLimei Chen
Weifang Key Laboratory for Antibodies Medicine, School of Life Science and Technology, Weifang Medical University, Weifang, China
6 shared publicationsBaowei Li
Weifang Key Laboratory for Antibodies Medicine, School of Life Science and Technology, Weifang Medical University, Weifang, China
5 shared publications
Latest Publications
- Open Access
- 29 May 2026
- Published by MDPI AG in Antibodies
- Vol. 15 (3) , 45
A Novel Monoclonal Antibody Targeting the A29 Protein of Monkeypox Virus and Its Application in Immunoassay
Background: The monkeypox virus (MPXV) has attracted considerable global attention due to its potential to cause widespread outbreaks, necessitating the development of rapid and accurate diagnostic methods of significant clinical importance. A29, a key envelope protein of MPXV, represents a promising diagnostic target. Methods: A novel monoclonal antibody, D10, was isolated from the human Tomlinson I+J phage display library by biopanning against the recombinant A29 protein. The D10 Fab fragment was expressed and purified, and its binding affinity was characterized by biolayer interferometry. Molecular docking was performed to predict potential interacting residues. Specificity and detection performance were evaluated by direct and competitive enzyme-linked immunosorbent assay (ELISA). Results: D10 possesses a unique complementarity-determining region sequence and exhibits strong binding affinity toward the A29 protein. Structural modeling analysis suggested potential interacting residues of A29, including Gln67, Arg74, Asn75, Arg81, and Asn84, which may primarily interact with Ser10, Thr5, Gly49, Gly47, and Glu97 in the heavy chain of D10. The binding affinity, determined by biolayer interferometry, showed a dissociation equilibrium constant of 6.44 nM, indicating strong binding capability. Furthermore, competitive ELISA demonstrated that D10 binds selectively to the A29 protein, with a half-maximal inhibitory concentration of 1.88 μg/mL and a limit of detection of 0.12 μg/mL. Conclusions: Overall, this monoclonal antibody provides a valuable tool for the immunological detection of MPXV and holds potential for future clinical diagnostic applications.
- 29 May 2026
- Published by MDPI AG in Antibodies
- Vol. 15 (3) , 45
Open AccessA Novel Monoclonal Antibody Targeting the A29 Protein of Monkeypox Virus and Its Application in Immunoassay
Background: The monkeypox virus (MPXV) has attracted considerable global attention due to its potential to cause widespread outbreaks, necessitating the development of rapid and accurate diagnostic methods of significant clinical importance. A29, a key envelope protein of MPXV, represents a promising diagnostic target. Methods: A novel monoclonal antibody, D10, was isolated from the human Tomlinson I+J phage display library by biopanning against the recombinant A29 protein. The D10 Fab fragment was expressed and purified, and its binding affinity was characterized by biolayer interferometry. Molecular docking was performed to predict potential interacting residues. Specificity and detection performance were evaluated by direct and competitive enzyme-linked immunosorbent assay (ELISA). Results: D10 possesses a unique complementarity-determining region sequence and exhibits strong binding affinity toward the A29 protein. Structural modeling analysis suggested potential interacting residues of A29, including Gln67, Arg74, Asn75, Arg81, and Asn84, which may primarily interact with Ser10, Thr5, Gly49, Gly47, and Glu97 in the heavy chain of D10. The binding affinity, determined by biolayer interferometry, showed a dissociation equilibrium constant of 6.44 nM, indicating strong binding capability. Furthermore, competitive ELISA demonstrated that D10 binds selectively to the A29 protein, with a half-maximal inhibitory concentration of 1.88 μg/mL and a limit of detection of 0.12 μg/mL. Conclusions: Overall, this monoclonal antibody provides a valuable tool for the immunological detection of MPXV and holds potential for future clinical diagnostic applications.
- 7 March 2026
- Published by Wiley in Reviews in Medical Virology
- Vol. 36 (2) , e70131
Insights Into Highly Associated Co‐Factors on HPV‐Related Cervical Cancer
Cervical cancer ranks among the most prevalent malignancies, representing a substantial threat to women's health. The incidence of cervical cancer is strongly correlated with persistent infections by high‐risk human papillomavirus (HPV) types. Overall, the prevalence of HPV infection is high, with most cases being classified as recessive, latent, and subclinical. The predominant HPV types and overall infection rates exhibit variability across different tissue types, individuals, and regions. Numerous co‐factors contribute to the processes underlying persistent HPV infection and carcinogenesis, including the microbiome, individual immune characteristics, and geographical population differences. Moreover, these factors affect the efficacy of chemotherapy and immunotherapy in cancer treatment. This review aims to summarise several key factors associated with HPV‐related cervical cancer and discuss their mechanisms in promoting carcinogenesis in HPV‐related malignancies. The insights gained may inform the development of more effective preventive and therapeutic strategies.
- 7 March 2026
- Published by Wiley in Reviews in Medical Virology
- Vol. 36 (2) , e70131
Insights Into Highly Associated Co‐Factors on HPV‐Related Cervical Cancer
Cervical cancer ranks among the most prevalent malignancies, representing a substantial threat to women's health. The incidence of cervical cancer is strongly correlated with persistent infections by high‐risk human papillomavirus (HPV) types. Overall, the prevalence of HPV infection is high, with most cases being classified as recessive, latent, and subclinical. The predominant HPV types and overall infection rates exhibit variability across different tissue types, individuals, and regions. Numerous co‐factors contribute to the processes underlying persistent HPV infection and carcinogenesis, including the microbiome, individual immune characteristics, and geographical population differences. Moreover, these factors affect the efficacy of chemotherapy and immunotherapy in cancer treatment. This review aims to summarise several key factors associated with HPV‐related cervical cancer and discuss their mechanisms in promoting carcinogenesis in HPV‐related malignancies. The insights gained may inform the development of more effective preventive and therapeutic strategies.
- Open Access
- 14 January 2025
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 26 (2) , 648
Crystal Structures of Antigen-Binding Fragment of Anti-Osteocalcin Antibody KTM219
Osteocalcin is a useful biomarker for bone formation and bone-related diseases. KTM219 is an anti-osteocalcin C-terminal peptide antibody. The single-chain variable region (scFv) and antigen-binding fragment (Fab) of KTM219 are applicable to the Quenchbody (Q-body) immunoassay. Q-body is a new type of fluorescent immunosensor, which is scFv or Fab labeled with a fluorescent dye. When Q-body binds to its antigen, the fluorescence intensity increases. The highly sensitive detection of antigens by changes in fluorescence intensity is performed in a single step by mixing the sample and reagent. In this study, to reveal the recognition mechanism of the KTM219 antibody and to discuss the structural basis for Q-body, we solved the crystal structures of Fab of the anti-osteocalcin antibody KTM219 and its complex with the antigen osteocalcin C-terminal peptide (BGP-C7). Also, we solved the structure of a KTM219 Fab crystal grown in the presence of a fluorescent dye, carboxytetramethylrhodamine (TAMRA); however, tightly bound TAMRA was not found in the electron density map. We predicted the binding sites of TAMRA in the antigen-binding pocket by docking simulations. These results support the proposed Q-body mechanism. The crystal structures of KTM219 Fab would be useful for further development and improvement of Q-body fluorescent immunosensors.
- 14 January 2025
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 26 (2) , 648
Open AccessCrystal Structures of Antigen-Binding Fragment of Anti-Osteocalcin Antibody KTM219
Osteocalcin is a useful biomarker for bone formation and bone-related diseases. KTM219 is an anti-osteocalcin C-terminal peptide antibody. The single-chain variable region (scFv) and antigen-binding fragment (Fab) of KTM219 are applicable to the Quenchbody (Q-body) immunoassay. Q-body is a new type of fluorescent immunosensor, which is scFv or Fab labeled with a fluorescent dye. When Q-body binds to its antigen, the fluorescence intensity increases. The highly sensitive detection of antigens by changes in fluorescence intensity is performed in a single step by mixing the sample and reagent. In this study, to reveal the recognition mechanism of the KTM219 antibody and to discuss the structural basis for Q-body, we solved the crystal structures of Fab of the anti-osteocalcin antibody KTM219 and its complex with the antigen osteocalcin C-terminal peptide (BGP-C7). Also, we solved the structure of a KTM219 Fab crystal grown in the presence of a fluorescent dye, carboxytetramethylrhodamine (TAMRA); however, tightly bound TAMRA was not found in the electron density map. We predicted the binding sites of TAMRA in the antigen-binding pocket by docking simulations. These results support the proposed Q-body mechanism. The crystal structures of KTM219 Fab would be useful for further development and improvement of Q-body fluorescent immunosensors.
- Open Access
- 11 October 2024
- Published by MDPI AG in Preprints.org
Crystal Structures of Antigen-Binding Fragment (Fab) of Anti-Osteocalcin Antibody KTM219: Structural Basis for Quenchbody (Q-body)
Quenchbody (Q-body), a new type of fluorescent immunosensor, is an antibody fragment labeled with a fluorescent dye. When Q-body binds to its antigen, the fluorescence intensity increases. Highly sensitive detection of antigens by changes in fluorescence intensity is performed in a single step by mixing sample and reagent. In this study, to reveal the structural basis for Q-body, we solved the crystal structures of antigen-binding fragment (Fab) of an anti-osteocalcin antibody KTM219, which is applicable to Q-body, and its complex with the antigen osteocalcin C-terminal peptide (BGP-C7). Also, we solved the structure of a KTM219 Fab crystal grown in the presence of a fluorescent dye 5(6)-carboxytetramethylrhodamine (TAMRA), however, a tightly bound TAMRA was not found in the electron density map. We predicted the binding site of TAMRA by docking simulations. These results support the structural basis for the Q-body mechanism as follows. In the absence of the antigen, the fluorophore located near tryptophan residues is quenched in the hydrophobic pocket of the antigen binding site between VH and VL. In association with the competitive binding of the antigen, the fluorophore is released from the antigen binding pocket and emits fluorescence. The crystal structures of KTM219 Fab and the structural basis of Q-body would be useful for further development and improvement of Q-body fluorescent immunosensors.
- 11 October 2024
- Published by MDPI AG in Preprints.org
Open AccessCrystal Structures of Antigen-Binding Fragment (Fab) of Anti-Osteocalcin Antibody KTM219: Structural Basis for Quenchbody (Q-body)
Quenchbody (Q-body), a new type of fluorescent immunosensor, is an antibody fragment labeled with a fluorescent dye. When Q-body binds to its antigen, the fluorescence intensity increases. Highly sensitive detection of antigens by changes in fluorescence intensity is performed in a single step by mixing sample and reagent. In this study, to reveal the structural basis for Q-body, we solved the crystal structures of antigen-binding fragment (Fab) of an anti-osteocalcin antibody KTM219, which is applicable to Q-body, and its complex with the antigen osteocalcin C-terminal peptide (BGP-C7). Also, we solved the structure of a KTM219 Fab crystal grown in the presence of a fluorescent dye 5(6)-carboxytetramethylrhodamine (TAMRA), however, a tightly bound TAMRA was not found in the electron density map. We predicted the binding site of TAMRA by docking simulations. These results support the structural basis for the Q-body mechanism as follows. In the absence of the antigen, the fluorophore located near tryptophan residues is quenched in the hydrophobic pocket of the antigen binding site between VH and VL. In association with the competitive binding of the antigen, the fluorophore is released from the antigen binding pocket and emits fluorescence. The crystal structures of KTM219 Fab and the structural basis of Q-body would be useful for further development and improvement of Q-body fluorescent immunosensors.
- Open Access
- 31 May 2024
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 12, 1395330
Detection of calcitonin gene-related peptide based on increased antigen-driven interaction with antibody variable regions
Introduction: Calcitonin gene-related peptide (CGRP) is involved in trigeminal neuralgia and migraine, and measuring the CGRP concentration in the serum is crucial for the early prediction of these conditions. Current methods for CGRP detection are primarily radioimmunoassay, which needs radioactive substances and enzyme-linked immunosorbent assays (ELISAs) which need long detection time and some have a narrow detection range.Methods: The genes of anti-CGRP antibody variable regions were cloned into pDong1 vector to obtain pDong1/Fab-CGRP, with which phage-Fab was prepared, and the concentration of CGRP was detected by competitive ELISA. The pDong1/Fab-CGRP was modified to obtain pDong1/OS-CGRP, with which the co-expression solution containing phage-displayed heavy chain variable fragments (phage-VH) and light chain was obtained. CGRP was detected by OS-ELISA based on phage-VH, antibody light chain, and anti-light chain antibody. The VL gene was cloned into the pMAL vector to obtain pMAL-VL (CGRP), with which maltose binding protein fused with VL (MBP-VL) was prepared. CGRP was detected by OS-ELISA employing MBP-VL and phage-VH.Results: OS-ELISAs that measure the CGRP concentration by quantifying the interaction between variable regions were investigated. OS-ELISA using phage-VH and secreted light chains in the same culture system exhibited a limit of detection (LOD) of 0.05 nM, offering higher sensitivity than competitive assay with an LOD of 0.75 nM, whereas using phage-VH and separately prepared MBP-VL exhibited an LOD of 0.15 nM and a broader detection range of 0.15–500 nM than competitive ELISA, whose detection range was 0.75–10 nM.Discussion: The combination of the two OS assays achieved high sensitivity and a broad detection range for CGRP, which may have significance in clinical applications.
- 31 May 2024
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 12, 1395330
Open AccessDetection of calcitonin gene-related peptide based on increased antigen-driven interaction with antibody variable regions
Introduction: Calcitonin gene-related peptide (CGRP) is involved in trigeminal neuralgia and migraine, and measuring the CGRP concentration in the serum is crucial for the early prediction of these conditions. Current methods for CGRP detection are primarily radioimmunoassay, which needs radioactive substances and enzyme-linked immunosorbent assays (ELISAs) which need long detection time and some have a narrow detection range.Methods: The genes of anti-CGRP antibody variable regions were cloned into pDong1 vector to obtain pDong1/Fab-CGRP, with which phage-Fab was prepared, and the concentration of CGRP was detected by competitive ELISA. The pDong1/Fab-CGRP was modified to obtain pDong1/OS-CGRP, with which the co-expression solution containing phage-displayed heavy chain variable fragments (phage-VH) and light chain was obtained. CGRP was detected by OS-ELISA based on phage-VH, antibody light chain, and anti-light chain antibody. The VL gene was cloned into the pMAL vector to obtain pMAL-VL (CGRP), with which maltose binding protein fused with VL (MBP-VL) was prepared. CGRP was detected by OS-ELISA employing MBP-VL and phage-VH.Results: OS-ELISAs that measure the CGRP concentration by quantifying the interaction between variable regions were investigated. OS-ELISA using phage-VH and secreted light chains in the same culture system exhibited a limit of detection (LOD) of 0.05 nM, offering higher sensitivity than competitive assay with an LOD of 0.75 nM, whereas using phage-VH and separately prepared MBP-VL exhibited an LOD of 0.15 nM and a broader detection range of 0.15–500 nM than competitive ELISA, whose detection range was 0.75–10 nM.Discussion: The combination of the two OS assays achieved high sensitivity and a broad detection range for CGRP, which may have significance in clinical applications.
- Open Access
- 28 November 2023
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 11, 1295406
Fluorescence quenching-based immunological probe for ticagrelor monitoring
Introduction: Ticagrelor is extensively utilized for the treatment of acute coronary syndromes (ACS), but its platelet aggregation inhibitory effects can potentially result in tissue bleeding, posing a serious risk to patients’ lives.Methods: In this study, we developed highly sensitive full length anti-ticagrelor Quenchbodies (Q-bodies) for fast monitoring of ticagrelor both in solution and serum for the first time. Ticagrelor coupled with N- hydroxysuccinimide (Ticagrelor-NHS) ester was also designed and synthesized for interaction and biological activity detection.Results: Both ATTO-labeled MEDI2452 (2452A) Q-body and TAMRA-labeled IgG 152 (152T) Q-body demonstrated efficient detection of ticagrelor and its active metabolite (TAM). The 2452A Q-body exhibited a broader detection range, while the 152T Q-body displayed a lower limit of detection (LOD). Under physiological conditions (Ticagrelor:TAM, 3:1), the concentration of ticagrelor was further measured, yielding LOD values of 4.65 pg/mL and 2.75 pg/mL for the two Q-bodies, with half-maximal effect concentrations of 8.15 ng/mL and 3.0 ng/mL, respectively.Discussion: Compared with traditional liquid chromatography-mass spectrometry (LC-MS) methods, anti-ticagrelor Q-bodies have higher sensitivity and detection speed. It enabled the completion of analysis within 3 min, facilitating rapid preoperative detection of blood drug concentration in ACS to determine the feasibility of surgery and mitigate the risk of intraoperative and postoperative hemorrhage. The swift detection of ticagrelor holds promise for enhancing individualized drug administration, preventing adverse reactions, and providing preoperative guidance.
- 28 November 2023
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 11, 1295406
Open AccessFluorescence quenching-based immunological probe for ticagrelor monitoring
Introduction: Ticagrelor is extensively utilized for the treatment of acute coronary syndromes (ACS), but its platelet aggregation inhibitory effects can potentially result in tissue bleeding, posing a serious risk to patients’ lives.Methods: In this study, we developed highly sensitive full length anti-ticagrelor Quenchbodies (Q-bodies) for fast monitoring of ticagrelor both in solution and serum for the first time. Ticagrelor coupled with N- hydroxysuccinimide (Ticagrelor-NHS) ester was also designed and synthesized for interaction and biological activity detection.Results: Both ATTO-labeled MEDI2452 (2452A) Q-body and TAMRA-labeled IgG 152 (152T) Q-body demonstrated efficient detection of ticagrelor and its active metabolite (TAM). The 2452A Q-body exhibited a broader detection range, while the 152T Q-body displayed a lower limit of detection (LOD). Under physiological conditions (Ticagrelor:TAM, 3:1), the concentration of ticagrelor was further measured, yielding LOD values of 4.65 pg/mL and 2.75 pg/mL for the two Q-bodies, with half-maximal effect concentrations of 8.15 ng/mL and 3.0 ng/mL, respectively.Discussion: Compared with traditional liquid chromatography-mass spectrometry (LC-MS) methods, anti-ticagrelor Q-bodies have higher sensitivity and detection speed. It enabled the completion of analysis within 3 min, facilitating rapid preoperative detection of blood drug concentration in ACS to determine the feasibility of surgery and mitigate the risk of intraoperative and postoperative hemorrhage. The swift detection of ticagrelor holds promise for enhancing individualized drug administration, preventing adverse reactions, and providing preoperative guidance.
- Open Access
- 17 April 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (17) , 15341-15349
Immunosensor for Rapid and Sensitive Detection of Digoxin
- 17 April 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (17) , 15341-15349
Open AccessImmunosensor for Rapid and Sensitive Detection of Digoxin
- Open Access
VH-Based Mini Q-Body: A Novel Quench-Based Immunosensor
Quenchbodies (Q-bodies), a type of biosensor, are antibodies labeled with a fluorescent dye near the antigen recognition site. In the absence of an antigen, the dye is quenched by tryptophans in the antibody sequence; however, in its presence, the dye is displaced and therefore de-quenched. Although scFv and Fab are mainly used to create Q-bodies, this is the first report where a single-domain heavy chain VH from a semi-synthetic human antibody library formed the basis. To create a proof of concept “mini Q-body”, a human anti-lysozyme single-domain VH antibody C3 was used. Mini Q-bodies were successfully developed using seven dyes. Different responses were observed depending on the dye and linker length; it was concluded that the optimal linker length for the TAMRA dye was C5, and rhodamine 6G was identified as the dye with the largest de-quenching response. Three single-domain antibodies with sequences similar to that of the C3 antibody were chosen, and the results confirmed the applicability of this method in developing mini Q-bodies. In summary, mini Q-bodies are an easy-to-use and time-saving method for detecting proteins.
Open AccessVH-Based Mini Q-Body: A Novel Quench-Based Immunosensor
Quenchbodies (Q-bodies), a type of biosensor, are antibodies labeled with a fluorescent dye near the antigen recognition site. In the absence of an antigen, the dye is quenched by tryptophans in the antibody sequence; however, in its presence, the dye is displaced and therefore de-quenched. Although scFv and Fab are mainly used to create Q-bodies, this is the first report where a single-domain heavy chain VH from a semi-synthetic human antibody library formed the basis. To create a proof of concept “mini Q-body”, a human anti-lysozyme single-domain VH antibody C3 was used. Mini Q-bodies were successfully developed using seven dyes. Different responses were observed depending on the dye and linker length; it was concluded that the optimal linker length for the TAMRA dye was C5, and rhodamine 6G was identified as the dye with the largest de-quenching response. Three single-domain antibodies with sequences similar to that of the C3 antibody were chosen, and the results confirmed the applicability of this method in developing mini Q-bodies. In summary, mini Q-bodies are an easy-to-use and time-saving method for detecting proteins.
- 28 January 2023
- Published by Elsevier in Analytical Biochemistry
- Vol. 665, 115069
Immunosensor for realtime monitoring of the expression of recombinant proteins during bioprocess
- 28 January 2023
- Published by Elsevier in Analytical Biochemistry
- Vol. 665, 115069
Immunosensor for realtime monitoring of the expression of recombinant proteins during bioprocess
- 30 September 2022
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 147 (22) , 4971-4979
Rapid and sensitive SARS-CoV-2 detection using a homogeneous fluorescent immunosensor Quenchbody with crowding agents
Antigen tests for SARS-CoV-2 are widely used by the public during the ongoing COVID-19 pandemic, which demonstrates the societal impact of homogeneous immunosensor-related technologies. In this study, we used the PM Q-probe and Quenchbody technologies to develop a SARS-CoV-2 nucleocapsid protein (N protein) homogeneous immunosensor based on a human anti-N protein antibody. For the first time, we uncovered the crowding agent's role in improving the performance of the double-labeled Quenchbody, and the possible mechanisms behind this improvement are discussed. The 5% polyethylene glycol 6000 significantly improved both the response speed and sensitivity of SARS-CoV-2 Quenchbodies. The calculated limit of detection for recombinant N protein was 191 pM (9 ng mL−1) within 15 min of incubation, which was 9- to 10-fold lower than the assay without adding crowding agent. We also validated the developed immunosensor in a point-of-care test by measuring specimens from COVID-19-positive patients using a compact tube fluorometer. In brief, this work shows the feasibility of Quenchbody homogeneous immunosensors as rapid and cost-efficient tools for the diagnosis and high-throughput analysis of swab samples in large-scale monitoring and epidemiological studies of COVID-19 or other emerging infectious diseases.
- 30 September 2022
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 147 (22) , 4971-4979
Rapid and sensitive SARS-CoV-2 detection using a homogeneous fluorescent immunosensor Quenchbody with crowding agents
Antigen tests for SARS-CoV-2 are widely used by the public during the ongoing COVID-19 pandemic, which demonstrates the societal impact of homogeneous immunosensor-related technologies. In this study, we used the PM Q-probe and Quenchbody technologies to develop a SARS-CoV-2 nucleocapsid protein (N protein) homogeneous immunosensor based on a human anti-N protein antibody. For the first time, we uncovered the crowding agent's role in improving the performance of the double-labeled Quenchbody, and the possible mechanisms behind this improvement are discussed. The 5% polyethylene glycol 6000 significantly improved both the response speed and sensitivity of SARS-CoV-2 Quenchbodies. The calculated limit of detection for recombinant N protein was 191 pM (9 ng mL−1) within 15 min of incubation, which was 9- to 10-fold lower than the assay without adding crowding agent. We also validated the developed immunosensor in a point-of-care test by measuring specimens from COVID-19-positive patients using a compact tube fluorometer. In brief, this work shows the feasibility of Quenchbody homogeneous immunosensors as rapid and cost-efficient tools for the diagnosis and high-throughput analysis of swab samples in large-scale monitoring and epidemiological studies of COVID-19 or other emerging infectious diseases.