Abdulsalam Alhadidi
Research Subjects
Abdulsalam Alhadidi has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Antonius Josephus Bernardus Kemperman
Membrane Science & Technology, Mesa+ Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
7 shared publications J.C. Schippers
UNESCO-IHE Delft , Westvest 7, P.O. Box 3015, 2601 DA , Delft , The Netherlands
7 shared publications- Matthias Wessling
Chemical Process Engineering RWTH Aachen University Aachen Germany
7 shared publications W.G.J. van der Meer
Faculty of Science and Technology, Membrane Technology Group, MESA+Institute for Nanotechnology, University of Twente , P.O. Box 217, 7500 AE , Enschede , The Netherlands
6 shared publicationsB. Blankert
Pentair X-Flow BV , P.O. Box 741, 7500 AS , Enschede , The Netherlands
4 shared publications- Rinnert Schurer
Evides Water Company, PO Box 4472, Rotterdam 3006 AL, the Netherlands; Department of Environmental Technology, Wageningen University, Bornse Weilanden 9, Wageningen 6708 WG, the Netherlands
2 shared publications
Latest Publications
- 12 September 2023
- Published by Elsevier in Water Research
- Vol. 245, 120625
Fate of organic micropollutants during brackish water desalination for drinking water production in decentralized capacitive electrodialysis
- 12 September 2023
- Published by Elsevier in Water Research
- Vol. 245, 120625
Fate of organic micropollutants during brackish water desalination for drinking water production in decentralized capacitive electrodialysis
- Open Access
- 1 January 2013
- Published by Elsevier in Desalination and Water Treatment
- Vol. 51 (4-6) , 1104-1113
Limitations, improvements and alternatives of the silt density index
Reverse osmosis (RO) membrane systems are widely used in the desalination of water. However, flux decline due to fouling phenomena in RO remains a challenge. To minimize fouling, a reliable index is necessary to predict the fouling potential of the RO feed water. The ASTM introduced the silt density index (SDI) as a standard fouling index to measure the fouling potential due to colloidal and suspended particles. For decades, the SDI is worldwide accepted and applied. There are growing doubts about the predictive value of this parameter. In addition there are several deficiencies observed, affecting the accuracy and reproducibility e.g. no correction factor for temperature, nor for variations in membrane resistance, and no linear correlation with the concentration of colloidal/suspended particles. This paper gives an overview of our work on limitations, improvements and alternatives for the SDI. Firstly, the influence of the applied 0.45 μm test membrane on the SDI will be investigated. Variations in SDI values can be attributed to differences in properties of these membranes. In order to quantify the influence of pressure, temperature and membrane resistance on the SDI a mathematical relation was developed between the SDI and the MFI0.45, assuming cake filtration. In addition, also other fouling mechanisms were incorporated in the model using the well-known blocking laws. Based on a cake filtration fouling mechanism and assuming 100% particle retention, the models were used to normalize the experimental SDI values for temperature, pressure and membrane resistance to the SDI+. By applying this normalization, the results of SDI tests carried out under different conditions and/or with different membranes can be compared easily as was proven experimentally in the lab and at a seawater desalination plant. Finally, an alternative filtration index will be introduced, the volume-based SDI_v. The SDI_v compares the initial flow rate to the flow rate after filtering a standard volume of feed water using MF membranes with an average pore size of 0.45 μm. Our experimental results show that SDI_v is independent of the membrane resistance. In that way, it eliminates most of the disadvantages of the SDI and has great potential to replace the SDI in the field.
- 1 January 2013
- Published by Elsevier in Desalination and Water Treatment
- Vol. 51 (4-6) , 1104-1113
Open AccessLimitations, improvements and alternatives of the silt density index
Reverse osmosis (RO) membrane systems are widely used in the desalination of water. However, flux decline due to fouling phenomena in RO remains a challenge. To minimize fouling, a reliable index is necessary to predict the fouling potential of the RO feed water. The ASTM introduced the silt density index (SDI) as a standard fouling index to measure the fouling potential due to colloidal and suspended particles. For decades, the SDI is worldwide accepted and applied. There are growing doubts about the predictive value of this parameter. In addition there are several deficiencies observed, affecting the accuracy and reproducibility e.g. no correction factor for temperature, nor for variations in membrane resistance, and no linear correlation with the concentration of colloidal/suspended particles. This paper gives an overview of our work on limitations, improvements and alternatives for the SDI. Firstly, the influence of the applied 0.45 μm test membrane on the SDI will be investigated. Variations in SDI values can be attributed to differences in properties of these membranes. In order to quantify the influence of pressure, temperature and membrane resistance on the SDI a mathematical relation was developed between the SDI and the MFI0.45, assuming cake filtration. In addition, also other fouling mechanisms were incorporated in the model using the well-known blocking laws. Based on a cake filtration fouling mechanism and assuming 100% particle retention, the models were used to normalize the experimental SDI values for temperature, pressure and membrane resistance to the SDI+. By applying this normalization, the results of SDI tests carried out under different conditions and/or with different membranes can be compared easily as was proven experimentally in the lab and at a seawater desalination plant. Finally, an alternative filtration index will be introduced, the volume-based SDI_v. The SDI_v compares the initial flow rate to the flow rate after filtering a standard volume of feed water using MF membranes with an average pore size of 0.45 μm. Our experimental results show that SDI_v is independent of the membrane resistance. In that way, it eliminates most of the disadvantages of the SDI and has great potential to replace the SDI in the field.
- Open Access
- 1 February 2012
- Published by Elsevier in Desalination and Water Treatment
- Vol. 40 (1-3) , 100-117
Sensitivity of SDI for experimental errors
- 1 February 2012
- Published by Elsevier in Desalination and Water Treatment
- Vol. 40 (1-3) , 100-117
Open AccessSensitivity of SDI for experimental errors
- 1 January 2012
- Published by Elsevier in Desalination
- Vol. 285, 153-162
Using SDI, SDI+ and MFI to evaluate fouling in a UF/RO desalination pilot plant
- 1 January 2012
- Published by Elsevier in Desalination
- Vol. 285, 153-162
Using SDI, SDI+ and MFI to evaluate fouling in a UF/RO desalination pilot plant
- 1 November 2011
- Published by Elsevier in Journal of Membrane Science
- Vol. 384 (1-2) , 205-218
The influence of membrane properties on the Silt Density Index
- 1 November 2011
- Published by Elsevier in Journal of Membrane Science
- Vol. 384 (1-2) , 205-218
The influence of membrane properties on the Silt Density Index
- 1 September 2011
- Published by Elsevier in Journal of Membrane Science
- Vol. 381 (1-2) , 142-151
Effect of testing conditions and filtration mechanisms on SDI
- 1 September 2011
- Published by Elsevier in Journal of Membrane Science
- Vol. 381 (1-2) , 142-151
Effect of testing conditions and filtration mechanisms on SDI
- 29 July 2011
- Published by Elsevier in Desalination
- Vol. 279 (1-3) , 390-403
SDI normalization and alternatives
- 29 July 2011
- Published by Elsevier in Desalination
- Vol. 279 (1-3) , 390-403
SDI normalization and alternatives
- 1 June 2011
- Published by Elsevier in Desalination
- Vol. 273 (1) , 48-56
Silt Density Index and Modified Fouling Index relation, and effect of pressure, temperature and membrane resistance
- 1 June 2011
- Published by Elsevier in Desalination
- Vol. 273 (1) , 48-56
Silt Density Index and Modified Fouling Index relation, and effect of pressure, temperature and membrane resistance
- Open Access
- 1 June 2009
- Published by Elsevier in Desalination and Water Treatment
- Vol. 6 (1-3) , 138-143
Scaling potential calculations using different methods
In this paper, the scaling potential of various sparingly soluble compounds was calculated in the concentrate of a full scale reverse osmosis (RO) plant, using various methods and commercially available software programs. The critical compounds calculated were CaCO3, CaSO4, BaSO4, SrSO4, and SiO2. Since July 2000, the Drenthe Water Supply Company (WMD) supplies highquality water to the Activated Carbon Manufacturing plant (Norit) in Klazienaveen. The production capacity is between 230,000 and 455,000 m3/year. The water source is canal water and shows high variations in water quality. To produce this capacity and to meet the water quality standard required for industrial use (boiler feed water), high chemical dosages are applied. Antiscalant is one of the chemicals currently dosed in order to avoid scaling and ensure smooth operation of the RO system. All the software programs employed (ROSA, IMS Design Hydranautics, 4Aqua care, and Phreeqc) and manual calculations with the ASTMmethod, showed different sca...
- 1 June 2009
- Published by Elsevier in Desalination and Water Treatment
- Vol. 6 (1-3) , 138-143
Open AccessScaling potential calculations using different methods
In this paper, the scaling potential of various sparingly soluble compounds was calculated in the concentrate of a full scale reverse osmosis (RO) plant, using various methods and commercially available software programs. The critical compounds calculated were CaCO3, CaSO4, BaSO4, SrSO4, and SiO2. Since July 2000, the Drenthe Water Supply Company (WMD) supplies highquality water to the Activated Carbon Manufacturing plant (Norit) in Klazienaveen. The production capacity is between 230,000 and 455,000 m3/year. The water source is canal water and shows high variations in water quality. To produce this capacity and to meet the water quality standard required for industrial use (boiler feed water), high chemical dosages are applied. Antiscalant is one of the chemicals currently dosed in order to avoid scaling and ensure smooth operation of the RO system. All the software programs employed (ROSA, IMS Design Hydranautics, 4Aqua care, and Phreeqc) and manual calculations with the ASTMmethod, showed different sca...