Héctor Corte-León
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Héctor Corte-León has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Olga Kazakova
National Physical Laboratory
13 shared publications - Alessandra Manzin
Istituto Nazionale di Ricerca Metrologica (INRIM), 10135 Torino, Italy
11 shared publications - Vladimir Antonov
Skolkovo Institute of Science and Technology 3 , Bolshoy Boulevard 30, Moscow
9 shared publications Hans Werner Schumacher
Physikalisch-Technische Bundesanstalt, Braunschweig, D-38116, Germany
5 shared publicationsOlga Kazakova
National Physical Laboratory, Teddington TW110LW, United Kingdom
5 shared publicationsPatryk Krzysteczko
Physikalisch-Technische Bundesanstalt, Braunschweig, D-38116, Germany
5 shared publications
Latest Publications
- Open Access
- 16 February 2021
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 126 (7) , 077202
Thermoelectric Signature of Individual Skyrmions
We experimentally study the thermoelectrical signature of individual skyrmions in chiral multilayers. Using a combination of controlled nucleation, single skyrmion annihilation, and magnetic field dependent measurements the thermoelectric signature of individual skyrmions is characterized. The observed signature is explained by the anomalous Nernst effect of the skyrmion’s spin structure. Possible topological contributions to the observed thermoelectrical signature are discussed. Such thermoelectrical characterization allows for noninvasive detection and counting of skyrmions and enables fundamental studies of topological thermoelectric effects on the nanoscale.- 16 February 2021
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 126 (7) , 077202
Open AccessThermoelectric Signature of Individual Skyrmions
We experimentally study the thermoelectrical signature of individual skyrmions in chiral multilayers. Using a combination of controlled nucleation, single skyrmion annihilation, and magnetic field dependent measurements the thermoelectric signature of individual skyrmions is characterized. The observed signature is explained by the anomalous Nernst effect of the skyrmion’s spin structure. Possible topological contributions to the observed thermoelectrical signature are discussed. Such thermoelectrical characterization allows for noninvasive detection and counting of skyrmions and enables fundamental studies of topological thermoelectric effects on the nanoscale. - Open Access
- 1 September 2020
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 4 (9) , 095025
Calibrated Kelvin-probe force microscopy of 2D materials using Pt-coated probes
Nanoscale characterization techniques are fundamental to continue increasing the performance and miniaturization of consumer electronics. Among all the available techniques, Kelvin-probe force microscopy (KPFM) provides nanoscale maps of the local work function, a paramount property related to many chemical and physical surface phenomena. For this reason, this technique has being extremely employed in the semiconductor industry, and now is becoming more and more important in the growing field of 2D materials, providing information about the electronic properties, the number of layers, and even the morphology of the samples. However, although all the collective efforts from the community, proper calibration of the technique to obtain reliable and consistent work-function values is still challenging. Here we show a calibration method that improves on current procedures by reducing the uncertainty. In particular, it allows grading probes more easily, thus being a tool to calibrate and to judge calibration in itself. The calibration method is applied to optimize Pt-coated probes, which are then used to characterize the work function of a 2D material, i.e. graphite flakes. The results demonstrate that the metallic probes are stable over time and exposure to high humidity levels, and that the calibration allows comparing measurements taken with several different probes on different samples, thus completely fulfilling the requirement of a good calibration method.
- 1 September 2020
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 4 (9) , 095025
Open AccessCalibrated Kelvin-probe force microscopy of 2D materials using Pt-coated probes
Nanoscale characterization techniques are fundamental to continue increasing the performance and miniaturization of consumer electronics. Among all the available techniques, Kelvin-probe force microscopy (KPFM) provides nanoscale maps of the local work function, a paramount property related to many chemical and physical surface phenomena. For this reason, this technique has being extremely employed in the semiconductor industry, and now is becoming more and more important in the growing field of 2D materials, providing information about the electronic properties, the number of layers, and even the morphology of the samples. However, although all the collective efforts from the community, proper calibration of the technique to obtain reliable and consistent work-function values is still challenging. Here we show a calibration method that improves on current procedures by reducing the uncertainty. In particular, it allows grading probes more easily, thus being a tool to calibrate and to judge calibration in itself. The calibration method is applied to optimize Pt-coated probes, which are then used to characterize the work function of a 2D material, i.e. graphite flakes. The results demonstrate that the metallic probes are stable over time and exposure to high humidity levels, and that the calibration allows comparing measurements taken with several different probes on different samples, thus completely fulfilling the requirement of a good calibration method.
Comparison and Validation of Different Magnetic Force Microscopy Calibration Schemes
The future of consumer electronics depends on the capability to reliably fabricate nanostructures with given physical properties. Therefore, techniques to characterize materials and devices with nanoscale resolution are crucial. Among these is magnetic force microscopy (MFM), which transduces the magnetic force between the sample and a magnetic oscillating probe into a phase shift, enabling the locally resolved study of magnetic field patterns down to 10 nm. Here, the progress done toward making quantitative MFM a common tool in nanocharacterization laboratories is shown. The reliability and ease of use of the calibration method based on a magnetic reference sample, with a calculable stray field, and a deconvolution algorithm is demonstrated. This is achieved by comparing two calibration approaches combined with numerical modeling as a quantitative link: measuring the probe's effect on the voltage signal when scanning above a nanosized graphene Hall sensor, and recording the MFM phase shift signal when the probe scans across magnetic fields produced by metallic microcoils. Furthermore, in the case of the deconvolution algorithm, it is shown how it can be applied using the open‐source software package Gwyddion. The estimated magnetic dipole approximation for the most common probes currently in the market is also reported.
Comparison and Validation of Different Magnetic Force Microscopy Calibration Schemes
The future of consumer electronics depends on the capability to reliably fabricate nanostructures with given physical properties. Therefore, techniques to characterize materials and devices with nanoscale resolution are crucial. Among these is magnetic force microscopy (MFM), which transduces the magnetic force between the sample and a magnetic oscillating probe into a phase shift, enabling the locally resolved study of magnetic field patterns down to 10 nm. Here, the progress done toward making quantitative MFM a common tool in nanocharacterization laboratories is shown. The reliability and ease of use of the calibration method based on a magnetic reference sample, with a calculable stray field, and a deconvolution algorithm is demonstrated. This is achieved by comparing two calibration approaches combined with numerical modeling as a quantitative link: measuring the probe's effect on the voltage signal when scanning above a nanosized graphene Hall sensor, and recording the MFM phase shift signal when the probe scans across magnetic fields produced by metallic microcoils. Furthermore, in the case of the deconvolution algorithm, it is shown how it can be applied using the open‐source software package Gwyddion. The estimated magnetic dipole approximation for the most common probes currently in the market is also reported.
- Open Access
- 15 November 2019
- Published by Springer Nature in Communications Physics
- Vol. 2 (1) , 1-9
Individual skyrmion manipulation by local magnetic field gradients
Magnetic skyrmions are topologically protected spin textures, stabilised in systems with strong Dzyaloshinskii-Moriya interaction (DMI). Several studies have shown that electrical currents can move skyrmions efficiently through spin-orbit torques. While promising for technological applications, current-driven skyrmion motion is intrinsically collective and accompanied by undesired heating effects. Here we demonstrate a new approach to control individual skyrmion positions precisely, which relies on the magnetic interaction between sample and a magnetic force microscopy (MFM) probe. We investigate perpendicularly magnetised X/CoFeB/MgO multilayers, where for X = W or Pt the DMI is sufficiently strong to allow for skyrmion nucleation in an applied field. We show that these skyrmions can be manipulated individually through the local field gradient generated by the scanning MFM probe with an unprecedented level of accuracy. Furthermore, we show that the probe stray field can assist skyrmion nucleation. Our proof-of-concepts results pave the way towards achieving current-free skyrmion control.
- 15 November 2019
- Published by Springer Nature in Communications Physics
- Vol. 2 (1) , 1-9
Open AccessIndividual skyrmion manipulation by local magnetic field gradients
Magnetic skyrmions are topologically protected spin textures, stabilised in systems with strong Dzyaloshinskii-Moriya interaction (DMI). Several studies have shown that electrical currents can move skyrmions efficiently through spin-orbit torques. While promising for technological applications, current-driven skyrmion motion is intrinsically collective and accompanied by undesired heating effects. Here we demonstrate a new approach to control individual skyrmion positions precisely, which relies on the magnetic interaction between sample and a magnetic force microscopy (MFM) probe. We investigate perpendicularly magnetised X/CoFeB/MgO multilayers, where for X = W or Pt the DMI is sufficiently strong to allow for skyrmion nucleation in an applied field. We show that these skyrmions can be manipulated individually through the local field gradient generated by the scanning MFM probe with an unprecedented level of accuracy. Furthermore, we show that the probe stray field can assist skyrmion nucleation. Our proof-of-concepts results pave the way towards achieving current-free skyrmion control.
- Open Access
- 28 February 2019
- Published by IOP Publishing in 2D Materials
- Vol. 6 (2) , 025023
Qualitative analysis of scanning gate microscopy on epitaxial graphene
We present scanning gate microscopy (SGM) studies of graphene Hall-cross devices where bi-layer graphene (2LG) regions show unexpected signal inversion relative to single-layer graphene (1LG), an observation reproduced via finite element modelling of the current densities. This is attributed to gate-induced charge carrier redistribution between the two layers in 2LG. Hall cross devices were fabricated from epitaxial graphene 6H–SiC(0 0 0 1) and were covered by 1LG/2LG with the area ratio of 85:15%, respectively. Local electric-field sensitivity maps of the devices were obtained in two different measurement geometries using electrical SGM with a conductive tip, where it was observed that the voltage of 2LG islands was inverted relative to anticipated reference maps. Finite element modelling of the current densities and voltage response showed good qualitative agreement with the SGM maps when the effect of the gate was reversed for 2LG. The behaviour is attributed to gate-induced charge carrier redistribution between the two layers in 2LG. The model can be used generally as a tool to predict mixed 1LG/2LG response to electric field. Moreover, regions near the corners of the device show the highest sensitivity when the local electric field was applied to the scanning probe microscopy tip. These regions are capable of detecting highly local electric fields down to 110 kV cm−1.
- 28 February 2019
- Published by IOP Publishing in 2D Materials
- Vol. 6 (2) , 025023
Open AccessQualitative analysis of scanning gate microscopy on epitaxial graphene
We present scanning gate microscopy (SGM) studies of graphene Hall-cross devices where bi-layer graphene (2LG) regions show unexpected signal inversion relative to single-layer graphene (1LG), an observation reproduced via finite element modelling of the current densities. This is attributed to gate-induced charge carrier redistribution between the two layers in 2LG. Hall cross devices were fabricated from epitaxial graphene 6H–SiC(0 0 0 1) and were covered by 1LG/2LG with the area ratio of 85:15%, respectively. Local electric-field sensitivity maps of the devices were obtained in two different measurement geometries using electrical SGM with a conductive tip, where it was observed that the voltage of 2LG islands was inverted relative to anticipated reference maps. Finite element modelling of the current densities and voltage response showed good qualitative agreement with the SGM maps when the effect of the gate was reversed for 2LG. The behaviour is attributed to gate-induced charge carrier redistribution between the two layers in 2LG. The model can be used generally as a tool to predict mixed 1LG/2LG response to electric field. Moreover, regions near the corners of the device show the highest sensitivity when the local electric field was applied to the scanning probe microscopy tip. These regions are capable of detecting highly local electric fields down to 110 kV cm−1.
- Open Access
- 26 February 2019
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 11 (10) , 4478-4488
Magnetic imaging using geometrically constrained nano-domain walls
Magnetic nanostructures, as part of hybrid CMOS technology, have the potential to overcome silicon's scaling limit. However, a major problem is how to characterize their magnetization without disturbing it. Magnetic force microscopy (MFM) offers a convenient way of studying magnetization, but spatial resolution and sensitivity are usually boosted at the cost of increasing probe-sample interaction. By using a single magnetic domain wall (DW), confined in a V-shape nanostructure fabricated at the probe apex, it is demonstrated here that the spatial resolution and the magnetic sensitivity can be decoupled and both enhanced. Indeed, owing to the nanostructure's strong shape anisotropy, DW-probes have 2 high and 2 low magnetic moment states with opposite polarities, characterised by a geometrically constrained pinned DW, and curled magnetization, respectively. Electron holography studies, supported by numerical simulations, and in situ MFM show that the DW-probe state can be controlled, and thus used as a switchable tool with a low/high stray field intensity.
- 26 February 2019
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 11 (10) , 4478-4488
Open AccessMagnetic imaging using geometrically constrained nano-domain walls
Magnetic nanostructures, as part of hybrid CMOS technology, have the potential to overcome silicon's scaling limit. However, a major problem is how to characterize their magnetization without disturbing it. Magnetic force microscopy (MFM) offers a convenient way of studying magnetization, but spatial resolution and sensitivity are usually boosted at the cost of increasing probe-sample interaction. By using a single magnetic domain wall (DW), confined in a V-shape nanostructure fabricated at the probe apex, it is demonstrated here that the spatial resolution and the magnetic sensitivity can be decoupled and both enhanced. Indeed, owing to the nanostructure's strong shape anisotropy, DW-probes have 2 high and 2 low magnetic moment states with opposite polarities, characterised by a geometrically constrained pinned DW, and curled magnetization, respectively. Electron holography studies, supported by numerical simulations, and in situ MFM show that the DW-probe state can be controlled, and thus used as a switchable tool with a low/high stray field intensity.
- Top Cited Papers
- 8 February 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 125 (6) , 060901
Frontiers of magnetic force microscopy
Since it was first demonstrated in 1987, magnetic force microscopy (MFM) has become a truly widespread and commonly used characterization technique that has been applied to a variety of research and industrial applications. Some of the main advantages of the method includes its high spatial resolution (typically ∼50 nm), ability to work in variable temperature and applied magnetic fields, versatility, and simplicity in operation, all without almost any need for sample preparation. However, for most commercial systems, the technique has historically provided only qualitative information, and the number of available modes was typically limited, thus not reflecting the experimental demands. Additionally, the range of samples under study was largely restricted to “classic” ferromagnetic samples (typically, thin films or patterned nanostructures). Throughout this Perspective article, the recent progress and development of MFM is described, followed by a summary of the current state-of-the-art techniques and objects for study. Finally, the future of this fascinating field is discussed in the context of emerging instrumental and material developments. Aspects including quantitative MFM, the accurate interpretation of the MFM images, new instrumentation, probe-engineering alternatives, and applications of MFM to new (often interdisciplinary) areas of the materials science, physics, and biology will be discussed. We first describe the physical principles of MFM, specifically paying attention to common artifacts frequently occurring in MFM measurements; then, we present a comprehensive review of the recent developments in the MFM modes, instrumentation, and the main application areas; finally, the importance of the technique is speculated upon for emerging or anticipated to emerge fields including skyrmions, 2D-materials, and topological insulators.
- 8 February 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 125 (6) , 060901
Top Cited PapersFrontiers of magnetic force microscopy
Since it was first demonstrated in 1987, magnetic force microscopy (MFM) has become a truly widespread and commonly used characterization technique that has been applied to a variety of research and industrial applications. Some of the main advantages of the method includes its high spatial resolution (typically ∼50 nm), ability to work in variable temperature and applied magnetic fields, versatility, and simplicity in operation, all without almost any need for sample preparation. However, for most commercial systems, the technique has historically provided only qualitative information, and the number of available modes was typically limited, thus not reflecting the experimental demands. Additionally, the range of samples under study was largely restricted to “classic” ferromagnetic samples (typically, thin films or patterned nanostructures). Throughout this Perspective article, the recent progress and development of MFM is described, followed by a summary of the current state-of-the-art techniques and objects for study. Finally, the future of this fascinating field is discussed in the context of emerging instrumental and material developments. Aspects including quantitative MFM, the accurate interpretation of the MFM images, new instrumentation, probe-engineering alternatives, and applications of MFM to new (often interdisciplinary) areas of the materials science, physics, and biology will be discussed. We first describe the physical principles of MFM, specifically paying attention to common artifacts frequently occurring in MFM measurements; then, we present a comprehensive review of the recent developments in the MFM modes, instrumentation, and the main application areas; finally, the importance of the technique is speculated upon for emerging or anticipated to emerge fields including skyrmions, 2D-materials, and topological insulators.
- Open Access
Magnetic Force Microscopy Imaging Using Geometrically Constrained Nano-Domain Walls
Domain wall probes (DW-probes) were custom-made by modifying standard commercial magnetic force microscopy (MFM) probes using focused ion beam lithography. Excess of magnetic coating from the probes was milled out, leaving a V-shaped nanostructure on one face of the probe apex. Owing to the nanostructure's shape anisotropy, such probe has four possible magnetic states depending on the direction of the magnetization along each arm of the V-shape. Two states of opposite polarity are characterised by the presence of a geometrically constrained DW, pinned at the corner of the V-shape nanostructure. In the other two states, the magnetization curls around the corner with opposite chirality. Electron holography studies, supported by numerical simulations, demonstrate that a strong stray field emanates from the pinned DW, whilst a much weaker stray field is generated by the curling configurations. Using in situ MFM, we show that the magnetization states of the DW-probe can be easily controlled by applying an external magnetic field, thereby demonstrating that this type of probe can be used as a switchable tool with a low or high stray field intensity. We demonstrate that DW-probes enable acquiring magnetic images with a negligible interference with the sample magnetization, similar to that of commercial low moment probes, but with a higher magnetic contrast. In addition, the DW-probe in the curl state provides complementary information about the in-plane component of the sample's magnetization, which is not achievable by standard methods and provides additional information about the stray fields, e.g. as when imaging DWs.
Open AccessMagnetic Force Microscopy Imaging Using Geometrically Constrained Nano-Domain Walls
Domain wall probes (DW-probes) were custom-made by modifying standard commercial magnetic force microscopy (MFM) probes using focused ion beam lithography. Excess of magnetic coating from the probes was milled out, leaving a V-shaped nanostructure on one face of the probe apex. Owing to the nanostructure's shape anisotropy, such probe has four possible magnetic states depending on the direction of the magnetization along each arm of the V-shape. Two states of opposite polarity are characterised by the presence of a geometrically constrained DW, pinned at the corner of the V-shape nanostructure. In the other two states, the magnetization curls around the corner with opposite chirality. Electron holography studies, supported by numerical simulations, demonstrate that a strong stray field emanates from the pinned DW, whilst a much weaker stray field is generated by the curling configurations. Using in situ MFM, we show that the magnetization states of the DW-probe can be easily controlled by applying an external magnetic field, thereby demonstrating that this type of probe can be used as a switchable tool with a low or high stray field intensity. We demonstrate that DW-probes enable acquiring magnetic images with a negligible interference with the sample magnetization, similar to that of commercial low moment probes, but with a higher magnetic contrast. In addition, the DW-probe in the curl state provides complementary information about the in-plane component of the sample's magnetization, which is not achievable by standard methods and provides additional information about the stray fields, e.g. as when imaging DWs.
- Open Access
- 3 August 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-13
Calibration of multi-layered probes with low/high magnetic moments
We present a comprehensive method for visualisation and quantification of the magnetic stray field of magnetic force microscopy (MFM) probes, applied to the particular case of custom-made multi-layered probes with controllable high/low magnetic moment states. The probes consist of two decoupled magnetic layers separated by a non-magnetic interlayer, which results in four stable magnetic states: ±ferromagnetic (FM) and ±antiferromagnetic (A-FM). Direct visualisation of the stray field surrounding the probe apex using electron holography convincingly demonstrates a striking difference in the spatial distribution and strength of the magnetic flux in FM and A-FM states. In situ MFM studies of reference samples are used to determine the probe switching fields and spatial resolution. Furthermore, quantitative values of the probe magnetic moments are obtained by determining their real space tip transfer function (RSTTF). We also map the local Hall voltage in graphene Hall nanosensors induced by the probes in different states. The measured transport properties of nanosensors and RSTTF outcomes are introduced as an input in a numerical model of Hall devices to verify the probe magnetic moments. The modelling results fully match the experimental measurements, outlining an all-inclusive method for the calibration of complex magnetic probes with a controllable low/high magnetic moment.
- 3 August 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-13
Open AccessCalibration of multi-layered probes with low/high magnetic moments
We present a comprehensive method for visualisation and quantification of the magnetic stray field of magnetic force microscopy (MFM) probes, applied to the particular case of custom-made multi-layered probes with controllable high/low magnetic moment states. The probes consist of two decoupled magnetic layers separated by a non-magnetic interlayer, which results in four stable magnetic states: ±ferromagnetic (FM) and ±antiferromagnetic (A-FM). Direct visualisation of the stray field surrounding the probe apex using electron holography convincingly demonstrates a striking difference in the spatial distribution and strength of the magnetic flux in FM and A-FM states. In situ MFM studies of reference samples are used to determine the probe switching fields and spatial resolution. Furthermore, quantitative values of the probe magnetic moments are obtained by determining their real space tip transfer function (RSTTF). We also map the local Hall voltage in graphene Hall nanosensors induced by the probes in different states. The measured transport properties of nanosensors and RSTTF outcomes are introduced as an input in a numerical model of Hall devices to verify the probe magnetic moments. The modelling results fully match the experimental measurements, outlining an all-inclusive method for the calibration of complex magnetic probes with a controllable low/high magnetic moment.
- Open Access
- 23 July 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 6295
Hybrid normal metal/ferromagnetic nanojunctions for domain wall tracking
Hybrid normal metal/ferromagnetic, gold/permalloy (Au/Py), nanojunctions are used to investigate magnetoresistance effects and track magnetization spatial distribution in L-shaped Py nanostructures. Transversal and longitudinal resistances are measured and compared for both straight and 90° corner sections of the Py nanostructure. Our results demonstrate that the absolute change in resistance is larger in the case of longitudinal measurements. However, due to the small background resistance, the relative change in the transversal resistance along the straight section is several orders of magnitude larger than the analogous longitudinal variation. These results prove that hybrid nanojunctions represent a significant improvement with respect to previously studied all-ferromagnetic crosses, as they also reduce the pinning potential at the junction and allow probing the magnetization locally. In addition, unusual metastable states with longitudinal domain walls along Py straight sections are observed. Micromagnetic simulations in combination with a magnetotransport model allow interpretation of the results and identification of the observed transitions.
- 23 July 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 6295
Open AccessHybrid normal metal/ferromagnetic nanojunctions for domain wall tracking
Hybrid normal metal/ferromagnetic, gold/permalloy (Au/Py), nanojunctions are used to investigate magnetoresistance effects and track magnetization spatial distribution in L-shaped Py nanostructures. Transversal and longitudinal resistances are measured and compared for both straight and 90° corner sections of the Py nanostructure. Our results demonstrate that the absolute change in resistance is larger in the case of longitudinal measurements. However, due to the small background resistance, the relative change in the transversal resistance along the straight section is several orders of magnitude larger than the analogous longitudinal variation. These results prove that hybrid nanojunctions represent a significant improvement with respect to previously studied all-ferromagnetic crosses, as they also reduce the pinning potential at the junction and allow probing the magnetization locally. In addition, unusual metastable states with longitudinal domain walls along Py straight sections are observed. Micromagnetic simulations in combination with a magnetotransport model allow interpretation of the results and identification of the observed transitions.