Mark L. Morrison
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mark L. Morrison has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
P.K. Liaw
11 shared publications- Chain Tsuan Liu
Hong Kong Institute for Advanced Study, City University of Hong Kong, Hong Kong, China
9 shared publications R.A. Buchanan
9 shared publicationsB. Yang
Metals and Ceramics Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831
4 shared publicationsJ.A. Horton
4 shared publicationsG.Y. Wang
3 shared publications
Latest Publications
- Open Access
- 9 June 2015
- Published by MDPI AG in Lubricants
- Vol. 3 (2) , 475-492
Design of an Advanced Bearing System for Total Knee Arthroplasty
The objective of this study was to develop an advanced-bearing couple for TKA that optimizes the balance between wear resistance and mechanical properties. The mechanical and structural properties of virgin and highly crosslinked, re-melted UHMWPE were evaluated, and tibial inserts manufactured from these UHMWPE materials were tested against either oxidized zirconium (OxZr) or CoCr femoral components on a knee simulator. This study confirmed that the wear resistance of crosslinked UHMWPE improves with increasing radiation dose but is accompanied by a concomitant reduction in mechanical properties. Compared to CoCr, the ceramic surface of OxZr allows the use of a lower irradiation dose to achieve equivalent reductions in wear rates. As a result, a given wear rate can be achieved without sacrificing the mechanical properties to the same extent that is necessary with a CoCr femoral component. The advantage of ceramic counter bearing surfaces extends to both pristine and microabrasive conditions.
- 9 June 2015
- Published by MDPI AG in Lubricants
- Vol. 3 (2) , 475-492
Open AccessDesign of an Advanced Bearing System for Total Knee Arthroplasty
The objective of this study was to develop an advanced-bearing couple for TKA that optimizes the balance between wear resistance and mechanical properties. The mechanical and structural properties of virgin and highly crosslinked, re-melted UHMWPE were evaluated, and tibial inserts manufactured from these UHMWPE materials were tested against either oxidized zirconium (OxZr) or CoCr femoral components on a knee simulator. This study confirmed that the wear resistance of crosslinked UHMWPE improves with increasing radiation dose but is accompanied by a concomitant reduction in mechanical properties. Compared to CoCr, the ceramic surface of OxZr allows the use of a lower irradiation dose to achieve equivalent reductions in wear rates. As a result, a given wear rate can be achieved without sacrificing the mechanical properties to the same extent that is necessary with a CoCr femoral component. The advantage of ceramic counter bearing surfaces extends to both pristine and microabrasive conditions.
- 1 August 2009
- Published by Elsevier in Intermetallics
- Vol. 17 (8) , 579-590
Progress in studying the fatigue behavior of Zr-based bulk-metallic glasses and their composites
- 1 August 2009
- Published by Elsevier in Intermetallics
- Vol. 17 (8) , 579-590
Progress in studying the fatigue behavior of Zr-based bulk-metallic glasses and their composites
- 1 January 2009
- Published by Wiley in Advanced Engineering Materials
- Vol. 11 (1-2) , 27-34
Mechanical and Fatigue Behavior of Ca65Mg15Zn20 Bulk‐Metallic Glass
- 1 January 2009
- Published by Wiley in Advanced Engineering Materials
- Vol. 11 (1-2) , 27-34
Mechanical and Fatigue Behavior of Ca65Mg15Zn20 Bulk‐Metallic Glass
- 5 November 2008
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 90B (1) , 87-100
Evaluation of sequentially crosslinked ultra‐high molecular weight polyethylene
This study was undertaken to investigate the effect of crosslinking ultra‐high molecular weight polyethylene (UHMWPE) in a sequential manner to the final desired dose and to compare the results to single‐dose crosslinking. To verify these results, an explanted, commercially available, sequentially crosslinked component was characterized. Finally, additional tensile testing was conducted to determine if tensile‐sample thickness has a significant effect on the mechanical properties of UHMWPE. Based upon this well‐controlled study with the same starting material, there is no apparent benefit of sequential crosslinking over crosslinking by single dose in any of the mechanical, thermophysical, physical, or oxidative properties evaluated in this study. In contrast, the soak temperature of the postirradiation heat treatment was more influential and exhibited statistically significant effects on the stability, structure, and properties of the resultant material. Compared to virgin material, crosslinking always resulted in decreases in tensile strength, elongation, and impact strength. These results were confirmed by characterization of a retrieved, sequentially crosslinked (X3™) cup. All of the metrics derived for the retrieved cup were virtually identical to the sequential‐ and single‐dose‐crosslinked materials produced in this study. Examination of the effect of tensile‐sample thickness demonstrated that there are significant effects on the resultant properties. In particular, the ultimate tensile strength of UHMWPE can be elevated by conducting tensile tests with thin specimens. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009
- 5 November 2008
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 90B (1) , 87-100
Evaluation of sequentially crosslinked ultra‐high molecular weight polyethylene
This study was undertaken to investigate the effect of crosslinking ultra‐high molecular weight polyethylene (UHMWPE) in a sequential manner to the final desired dose and to compare the results to single‐dose crosslinking. To verify these results, an explanted, commercially available, sequentially crosslinked component was characterized. Finally, additional tensile testing was conducted to determine if tensile‐sample thickness has a significant effect on the mechanical properties of UHMWPE. Based upon this well‐controlled study with the same starting material, there is no apparent benefit of sequential crosslinking over crosslinking by single dose in any of the mechanical, thermophysical, physical, or oxidative properties evaluated in this study. In contrast, the soak temperature of the postirradiation heat treatment was more influential and exhibited statistically significant effects on the stability, structure, and properties of the resultant material. Compared to virgin material, crosslinking always resulted in decreases in tensile strength, elongation, and impact strength. These results were confirmed by characterization of a retrieved, sequentially crosslinked (X3™) cup. All of the metrics derived for the retrieved cup were virtually identical to the sequential‐ and single‐dose‐crosslinked materials produced in this study. Examination of the effect of tensile‐sample thickness demonstrated that there are significant effects on the resultant properties. In particular, the ultimate tensile strength of UHMWPE can be elevated by conducting tensile tests with thin specimens. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009
- 1 December 2007
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 471 (1-2) , 125-129
Structural changes in bulk metallic glass after annealing below the glass-transition temperature
- 1 December 2007
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 471 (1-2) , 125-129
Structural changes in bulk metallic glass after annealing below the glass-transition temperature
- 1 October 2007
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 467 (1-2) , 190-197
Four-point-bending-fatigue behavior of the Zr-based Vitreloy 105 bulk metallic glass
- 1 October 2007
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 467 (1-2) , 190-197
Four-point-bending-fatigue behavior of the Zr-based Vitreloy 105 bulk metallic glass
- 1 October 2007
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 467 (1-2) , 198-206
Corrosion–fatigue studies of the Zr-based Vitreloy 105 bulk metallic glass
- 1 October 2007
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 467 (1-2) , 198-206
Corrosion–fatigue studies of the Zr-based Vitreloy 105 bulk metallic glass
- 1 July 2007
- Published by Elsevier in Journal of Non-Crystalline Solids
- Vol. 353 (22-23) , 2115-2124
Electrochemical behavior of a Ti-based bulk metallic glass
- 1 July 2007
- Published by Elsevier in Journal of Non-Crystalline Solids
- Vol. 353 (22-23) , 2115-2124
Electrochemical behavior of a Ti-based bulk metallic glass
- 1 April 2006
- Published by Springer Nature in Metallurgical and Materials Transactions A
- Vol. 37 (4) , 1239-1245
Electrochemical behavior of Ca-based bulk metallic glasses
- 1 April 2006
- Published by Springer Nature in Metallurgical and Materials Transactions A
- Vol. 37 (4) , 1239-1245
Electrochemical behavior of Ca-based bulk metallic glasses
- 1 April 2006
- Published by Springer Nature in Journal of Materials Research
- Vol. 21 (4) , 915-922
Localized heating and fracture criterion for bulk metallic glasses
In this study, we demonstrated that the failure of bulk metallic glasses (BMGs) results from a sudden temperature rise within a shear band. Using a shear transformation zone model, we successfully calculated the temperature within a shear band and found it consistent with the observation from an in situ infrared thermographic system. The instantaneous temperature within a shear band at fracture agrees remarkably well with the glass transition temperature (Tgproviding a new criterion to determine the strength of BMGs from theirTg. This agreement also discloses the fact that catastrophic failure of BMG is caused by the sudden drop in viscosity inside the shear band when the instantaneous temperature within a shear band approachesTg.
- 1 April 2006
- Published by Springer Nature in Journal of Materials Research
- Vol. 21 (4) , 915-922
Localized heating and fracture criterion for bulk metallic glasses
In this study, we demonstrated that the failure of bulk metallic glasses (BMGs) results from a sudden temperature rise within a shear band. Using a shear transformation zone model, we successfully calculated the temperature within a shear band and found it consistent with the observation from an in situ infrared thermographic system. The instantaneous temperature within a shear band at fracture agrees remarkably well with the glass transition temperature (Tgproviding a new criterion to determine the strength of BMGs from theirTg. This agreement also discloses the fact that catastrophic failure of BMG is caused by the sudden drop in viscosity inside the shear band when the instantaneous temperature within a shear band approachesTg.