German A. Messina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
German A. Messina has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
Julio Raba
Instituto de Química de San Luis (INQUISAL), Departamento de Química, Universidad Nacional de San Luis, CONICET, Chacabuco 917, D5700BWS, San Luis, Argentina
17 shared publications- Martin A. Fernandez Baldo
Instituto de Química de San Luis, Facultad de Química, Universidad Nacional de San Luis, INQUISAL (UNSL—CONICET), Ejército de los Andes 950, San Luis D5700BWS, Argentina
13 shared publications Sirley V. Pereira
10 shared publications- Matías Regiart
Instituto de Química de San Luis, Facultad de Química, Universidad Nacional de San Luis, INQUISAL (UNSL—CONICET), Ejército de los Andes 950, San Luis D5700BWS, Argentina
8 shared publications - Sirley V. Pereira
INQUISAL
6 shared publications Eduardo A. Takara
5 shared publications
Latest Publications
- Open Access
- 4 July 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (7) , 431
A New Sensing Platform Based in CNF-TiO2NPs-Wax on Polyimide Substrate for Celiac Disease Diagnostic
Celiac disease (CD), a human leukocyte antigen-associated disorder, is caused by gluten sensitivity and is characterized by mucosal alterations in the small intestine. Currently, its diagnosis involves the determination of serological markers. The traditional method for clinically determining these markers is the enzyme-linked immunosorbent assay. However, immunosensors offer sensitivity and facilitate the development of miniaturized and portable analytical systems. This work focuses on developing an amperometric immunosensor for the quantification of IgA antibodies against tissue transglutaminase (IgA anti-TGA) in human serum samples, providing information on a critical biomarker for CD diagnosis. The electrochemical device was designed on a polyimide substrate using a novel solid ink of wax and carbon nanofibers (CNFs). The working electrode microzone was defined by incorporating aminofunctionalized TiO2 nanoparticles (TiO2NPs). The interactions and morphology of CNFs/wax and TiO2NPs/CNFs/wax electrodes were assessed through different characterization techniques. Furthermore, the device was electrochemically characterized, demonstrating that the incorporation of CNFs into the wax matrix significantly enhanced its conductivity and increased the active surface area of the electrode, while TiO2NPs contributed to the immunoreaction area. The developed device exhibited remarkable sensitivity, selectivity, and reproducibility. These results indicate that the fabricated device is a robust and reliable tool for the precise serological diagnosis of CD.
- 4 July 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (7) , 431
Open AccessA New Sensing Platform Based in CNF-TiO2NPs-Wax on Polyimide Substrate for Celiac Disease Diagnostic
Celiac disease (CD), a human leukocyte antigen-associated disorder, is caused by gluten sensitivity and is characterized by mucosal alterations in the small intestine. Currently, its diagnosis involves the determination of serological markers. The traditional method for clinically determining these markers is the enzyme-linked immunosorbent assay. However, immunosensors offer sensitivity and facilitate the development of miniaturized and portable analytical systems. This work focuses on developing an amperometric immunosensor for the quantification of IgA antibodies against tissue transglutaminase (IgA anti-TGA) in human serum samples, providing information on a critical biomarker for CD diagnosis. The electrochemical device was designed on a polyimide substrate using a novel solid ink of wax and carbon nanofibers (CNFs). The working electrode microzone was defined by incorporating aminofunctionalized TiO2 nanoparticles (TiO2NPs). The interactions and morphology of CNFs/wax and TiO2NPs/CNFs/wax electrodes were assessed through different characterization techniques. Furthermore, the device was electrochemically characterized, demonstrating that the incorporation of CNFs into the wax matrix significantly enhanced its conductivity and increased the active surface area of the electrode, while TiO2NPs contributed to the immunoreaction area. The developed device exhibited remarkable sensitivity, selectivity, and reproducibility. These results indicate that the fabricated device is a robust and reliable tool for the precise serological diagnosis of CD.
- Open Access
- 11 October 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (10) , 208
Paper-Based Analytical Devices Based on Amino-MOFs (MIL-125, UiO-66, and MIL-101) as Platforms towards Fluorescence Biodetection Applications
In this study, we designed three promising platforms based on metal–organic frameworks (MOFs) to develop paper-based analytical devices (PADs) for biosensing applications. PADs have become increasingly popular in field sensing in recent years due to their portability, low cost, simplicity, efficiency, fast detection capability, excellent sensitivity, and selectivity. In addition, MOFs are excellent choices for developing highly sensitive and selective sensors due their versatility for functionalizing, structural stability, and capability to adsorb and desorb specific molecules by reversible interactions. These materials also offer the possibility to modify their structure and properties, making them highly versatile and adaptable to different environments and sensing needs. In this research, we synthesized and characterized three different amino-functionalized MOFs: UiO-66-NH2 (Zr), MIL-125-NH2 (Ti), and MIL-101-NH2 (Fe). These MOFs were used to fabricate PADs capable of sensitive and portable monitoring of alkaline phosphatase (ALP) enzyme activity by laser-induced fluorescence (LIF). Overall, amino-derivated MOF platforms demonstrate significant potential for integration into biosensor PADs, offering key properties that enhance their performance and applicability in analytical chemistry and diagnostics.
- 11 October 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (10) , 208
Open AccessPaper-Based Analytical Devices Based on Amino-MOFs (MIL-125, UiO-66, and MIL-101) as Platforms towards Fluorescence Biodetection Applications
In this study, we designed three promising platforms based on metal–organic frameworks (MOFs) to develop paper-based analytical devices (PADs) for biosensing applications. PADs have become increasingly popular in field sensing in recent years due to their portability, low cost, simplicity, efficiency, fast detection capability, excellent sensitivity, and selectivity. In addition, MOFs are excellent choices for developing highly sensitive and selective sensors due their versatility for functionalizing, structural stability, and capability to adsorb and desorb specific molecules by reversible interactions. These materials also offer the possibility to modify their structure and properties, making them highly versatile and adaptable to different environments and sensing needs. In this research, we synthesized and characterized three different amino-functionalized MOFs: UiO-66-NH2 (Zr), MIL-125-NH2 (Ti), and MIL-101-NH2 (Fe). These MOFs were used to fabricate PADs capable of sensitive and portable monitoring of alkaline phosphatase (ALP) enzyme activity by laser-induced fluorescence (LIF). Overall, amino-derivated MOF platforms demonstrate significant potential for integration into biosensor PADs, offering key properties that enhance their performance and applicability in analytical chemistry and diagnostics.
- Open Access
- 29 August 2024
- Published by MDPI AG in Preprints.org
Paper-Based Analytical Devices Based on Amino-MOFs (Mil-125, UiO-66 and Mil-101) as Platforms towards Biosensing Applications
In this study, we have designed a promising platform based on metal-organic frameworks (MOFs) to develop paper-based analytical devices (PADs) to immobilize biomolecules for application in biosensors. PADs have become increasingly popular in sensing applications in recent years due to their portability, low cost, simplicity, efficiency, fast detection capability, excellent sensitivity, and selectivity. In addition, MOFs are an excellent choice for developing highly sensitive and selective sensors. Their ability to reversibly and reproducibly adsorb and desorb specific molecules allows using these materials as sensors for various applications. They also offer the possibility to modify their structure and properties, making them highly versatile and adaptable to different environments and sensing needs. In this research, we synthesized and characterized three different amino-functionalized MOFs: UiO66-NH2 (Zr), MIL125-NH2 (Ti), and MIL101-NH2 (Fe). These MOFs were used to fabricate PADs capable of sensitive and portable monitoring of alkaline phosphatase (ALP) enzyme activity by laser-induced fluorescence (LIF). Overall, amino-derivated MOF platforms demonstrate significant potential for integration into biosensor PADs, offering key properties that enhance their performance and applicability in analytical chemistry and diagnostics.
- 29 August 2024
- Published by MDPI AG in Preprints.org
Open AccessPaper-Based Analytical Devices Based on Amino-MOFs (Mil-125, UiO-66 and Mil-101) as Platforms towards Biosensing Applications
In this study, we have designed a promising platform based on metal-organic frameworks (MOFs) to develop paper-based analytical devices (PADs) to immobilize biomolecules for application in biosensors. PADs have become increasingly popular in sensing applications in recent years due to their portability, low cost, simplicity, efficiency, fast detection capability, excellent sensitivity, and selectivity. In addition, MOFs are an excellent choice for developing highly sensitive and selective sensors. Their ability to reversibly and reproducibly adsorb and desorb specific molecules allows using these materials as sensors for various applications. They also offer the possibility to modify their structure and properties, making them highly versatile and adaptable to different environments and sensing needs. In this research, we synthesized and characterized three different amino-functionalized MOFs: UiO66-NH2 (Zr), MIL125-NH2 (Ti), and MIL101-NH2 (Fe). These MOFs were used to fabricate PADs capable of sensitive and portable monitoring of alkaline phosphatase (ALP) enzyme activity by laser-induced fluorescence (LIF). Overall, amino-derivated MOF platforms demonstrate significant potential for integration into biosensor PADs, offering key properties that enhance their performance and applicability in analytical chemistry and diagnostics.
- 16 May 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (23) , 3774-3783
Chemometrically assisted differential pulse voltammetry for simultaneous and interference-free quantification of gallic and caffeic acids
This article explores the application of chemometric tools including multivariate curve resolution with alternating least squares for the simultaneous determination of gallic and caffeic acids on the surface of a glassy carbon electrode without additional modification. Gallic and caffeic acids are primary polyphenols, the most abundant in red wines produced in Argentina, and are often used as quality markers for them. These polyphenols significantly contribute to the organoleptic properties of wines from this origin, but their electrochemical signals overlap significantly, making simultaneous quantification challenging without additional experiments such as electrode modification or alternative analytical techniques beyond differential pulse voltammetry. This study successfully quantified these compounds in complex mixtures by generating second-order data from differential pulse voltammetry experiments conducted at various potential steps and subsequently applying multivariate curve resolution with alternating least squares. The use of constraints during optimization prevented rotational ambiguities common in this modeling, leading to unique results in validation samples. The limits of detection (LOD) found for gallic and caffeic acids were 1.6 and 7.6 mg L−1, which are in excellent agreement with the expected concentrations of these compounds in red wines. The concentration ranges analyzed showed a linear dependency (between the LOD and 300 mg L−1) with the signals estimated by the model for both analytes. Advantages such as simplicity, low cost, and high speed, as well as not requiring electrode modification, combined with excellent results obtained for real samples, make it a promising alternative for polyphenol analysis in the wine industry.
- 16 May 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (23) , 3774-3783
Chemometrically assisted differential pulse voltammetry for simultaneous and interference-free quantification of gallic and caffeic acids
This article explores the application of chemometric tools including multivariate curve resolution with alternating least squares for the simultaneous determination of gallic and caffeic acids on the surface of a glassy carbon electrode without additional modification. Gallic and caffeic acids are primary polyphenols, the most abundant in red wines produced in Argentina, and are often used as quality markers for them. These polyphenols significantly contribute to the organoleptic properties of wines from this origin, but their electrochemical signals overlap significantly, making simultaneous quantification challenging without additional experiments such as electrode modification or alternative analytical techniques beyond differential pulse voltammetry. This study successfully quantified these compounds in complex mixtures by generating second-order data from differential pulse voltammetry experiments conducted at various potential steps and subsequently applying multivariate curve resolution with alternating least squares. The use of constraints during optimization prevented rotational ambiguities common in this modeling, leading to unique results in validation samples. The limits of detection (LOD) found for gallic and caffeic acids were 1.6 and 7.6 mg L−1, which are in excellent agreement with the expected concentrations of these compounds in red wines. The concentration ranges analyzed showed a linear dependency (between the LOD and 300 mg L−1) with the signals estimated by the model for both analytes. Advantages such as simplicity, low cost, and high speed, as well as not requiring electrode modification, combined with excellent results obtained for real samples, make it a promising alternative for polyphenol analysis in the wine industry.
- Open Access
- 5 January 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (1) , 10
Origami Paper-Based Electrochemical Immunosensor with Carbon Nanohorns-Decorated Nanoporous Gold for Zearalenone Detection
Nowadays, mycotoxin contamination in cereals and wastewater exposes a safety hazard to consumer health. This work describes the design of a simple, low-cost, and sensitive origami microfluidic paper-based device using electrochemical detection for zearalenone determination. The microfluidic immunosensor was designed on a paper platform by a wax printing process. The graphitized carbon working electrode modified with carbon nanohorns-decorated nanoporous gold showed a higher surface area, sensitivity, and adequate analytical performance. Electrodes were characterized by scanning electron microscopy, energy-dispersive spectroscopy, and cyclic voltammetry. The determination of zearalenone was carried out through a competitive immunoassay using specific antibodies immobilized by a covalent bond on the electrode surface. In the presence of HRP-labeled enzyme conjugate, substrate, and catechol, zearalenone was detected employing the developed immunosensor by applying −0.1 V to the working electrode vs silver as a pseudo-reference electrode. A calibration curve with a linear range between 10 and 1000 µg Kg−1 (R2 = 0.998) was obtained, and the limit of detection and quantification for the electrochemical immunosensor were 4.40 and 14.90 µg Kg−1, respectively. The coefficient of variation for intra- and inter-day assays was less than 5%. The selectivity and specificity of the sensor were evaluated, comparing the response against zearalenone metabolites and other mycotoxins that could affect the corn samples. Therefore, origami is a promising approach for paper-based electrochemical microfluidic sensors coupled to smartphones as a rapid and portable tool for in situ mycotoxins detection in real samples.
- 5 January 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (1) , 10
Open AccessOrigami Paper-Based Electrochemical Immunosensor with Carbon Nanohorns-Decorated Nanoporous Gold for Zearalenone Detection
Nowadays, mycotoxin contamination in cereals and wastewater exposes a safety hazard to consumer health. This work describes the design of a simple, low-cost, and sensitive origami microfluidic paper-based device using electrochemical detection for zearalenone determination. The microfluidic immunosensor was designed on a paper platform by a wax printing process. The graphitized carbon working electrode modified with carbon nanohorns-decorated nanoporous gold showed a higher surface area, sensitivity, and adequate analytical performance. Electrodes were characterized by scanning electron microscopy, energy-dispersive spectroscopy, and cyclic voltammetry. The determination of zearalenone was carried out through a competitive immunoassay using specific antibodies immobilized by a covalent bond on the electrode surface. In the presence of HRP-labeled enzyme conjugate, substrate, and catechol, zearalenone was detected employing the developed immunosensor by applying −0.1 V to the working electrode vs silver as a pseudo-reference electrode. A calibration curve with a linear range between 10 and 1000 µg Kg−1 (R2 = 0.998) was obtained, and the limit of detection and quantification for the electrochemical immunosensor were 4.40 and 14.90 µg Kg−1, respectively. The coefficient of variation for intra- and inter-day assays was less than 5%. The selectivity and specificity of the sensor were evaluated, comparing the response against zearalenone metabolites and other mycotoxins that could affect the corn samples. Therefore, origami is a promising approach for paper-based electrochemical microfluidic sensors coupled to smartphones as a rapid and portable tool for in situ mycotoxins detection in real samples.
- 15 June 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1273, 341499
Modification of electrodes with polymer nanocomposites: Application to the simultaneous determination of Zn(II), Cd(II), and Cu(II) in water samples
- 15 June 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1273, 341499
Modification of electrodes with polymer nanocomposites: Application to the simultaneous determination of Zn(II), Cd(II), and Cu(II) in water samples
- Open Access
- 16 March 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (3) , 390
Microfluidic Platform Integrated with Carbon Nanofibers-Decorated Gold Nanoporous Sensing Device for Serum PSA Quantification
Prostate cancer is a disease with a high incidence and mortality rate in men worldwide. Serum prostate-specific antigens (PSA) are the main circulating biomarker for this disease in clinical practices. In this work, we present a portable and reusable microfluidic device for PSA quantification. This device comprises a polymethyl methacrylate microfluidic platform coupled with electrochemical detection. The platinum working microelectrode was positioned in the outflow region of the microchannel and was modified with carbon nanofibers (CNF)-decorated gold nanoporous (GNP) structures by the dynamic hydrogen bubble template method, through the simultaneous electrodeposition of metal precursors in the presence of CNF. CNF/GNP structures exhibit attractive properties, such as a large surface to volume ratio, which increases the antibody’s immobilization capacity and the electroactive area. CNFs/GNP structures were characterized by scanning electron microscopy, energy dispersive spectrometry, and cyclic voltammetry. Anti-PSA antibodies and HRP were employed for the immune-electrochemical reaction. The detection limit for the device was 5 pg mL−1, with a linear range from 0.01 to 50 ng mL−1. The coefficients of variation within and between assays were lower than 4.40%, and 6.15%, respectively. Additionally, its clinical performance was tested in serum from 30 prostate cancer patients. This novel device was a sensitive, selective, portable, and reusable tool for the serological diagnosis and monitoring of prostate cancer.
- 16 March 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (3) , 390
Open AccessMicrofluidic Platform Integrated with Carbon Nanofibers-Decorated Gold Nanoporous Sensing Device for Serum PSA Quantification
Prostate cancer is a disease with a high incidence and mortality rate in men worldwide. Serum prostate-specific antigens (PSA) are the main circulating biomarker for this disease in clinical practices. In this work, we present a portable and reusable microfluidic device for PSA quantification. This device comprises a polymethyl methacrylate microfluidic platform coupled with electrochemical detection. The platinum working microelectrode was positioned in the outflow region of the microchannel and was modified with carbon nanofibers (CNF)-decorated gold nanoporous (GNP) structures by the dynamic hydrogen bubble template method, through the simultaneous electrodeposition of metal precursors in the presence of CNF. CNF/GNP structures exhibit attractive properties, such as a large surface to volume ratio, which increases the antibody’s immobilization capacity and the electroactive area. CNFs/GNP structures were characterized by scanning electron microscopy, energy dispersive spectrometry, and cyclic voltammetry. Anti-PSA antibodies and HRP were employed for the immune-electrochemical reaction. The detection limit for the device was 5 pg mL−1, with a linear range from 0.01 to 50 ng mL−1. The coefficients of variation within and between assays were lower than 4.40%, and 6.15%, respectively. Additionally, its clinical performance was tested in serum from 30 prostate cancer patients. This novel device was a sensitive, selective, portable, and reusable tool for the serological diagnosis and monitoring of prostate cancer.