Murat Beyhan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Murat Beyhan has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Erkan Gökçe
Department of Radiology, Medical School Tokat Gaziosmanpaşa University Tokat Turkey
12 shared publications - Berat Acu
Department of Radiology, Division of Interventional Radiology Eskişehir Osmangazi University Eskişehir Turkey
3 shared publications - Dogan Atilgan
Department of Urology, Gaziosmanpasa University Faculty of Medicine, Tokat, Turkey
3 shared publications - Engin Kölükçü
Department of Urology, Tokat Gaziosmanpaşa University Faculty of Medicine, Tokat, Türkiye
3 shared publications - Hüseyin Alper Kızıloğlu
Department of Radiology, Tokat Gaziosmanpaşa University Faculty of Medicine, Tokat, Türkiye
3 shared publications - Şükrüye Firuze Ocak Karataş
Department of Radiology, Bezmialem Vakıf University, Dragos Hospital, İstanbul, Turkey
3 shared publications
Latest Publications
- Open Access
- 24 July 2026
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 26 (1) , 332
Association of laboratory and radiological findings during hospitalization with early post-COVID pulmonary function and exercise capacity: a retrospective study
- 24 July 2026
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 26 (1) , 332
Open AccessAssociation of laboratory and radiological findings during hospitalization with early post-COVID pulmonary function and exercise capacity: a retrospective study
- 17 April 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
A Hybrid Approach for Differentiating Fibrotic Hypersensitivity Pneumonitis and Idiopathic Pulmonary Fibrosis: Deep Feature Extraction and Machine Learning
In patients over 60 years of age who are male, non-smokers, and in whom no organic antigen is identified in the history, differentiating fibrotic hypersensitivity pneumonitis (HP) from idiopathic pulmonary fibrosis (IPF) may be challenging. We aimed to evaluate the contribution of deep learning-based feature extraction and machine learning classification in differentiating these two pathologies, which exhibit similar radiological patterns on high-resolution computed tomography (HRCT) images. The study retrospectively included 87 patients (52 IPF, 35 HP). To completely eliminate data leakage and class imbalance-common methodological flaws in medical AI-we implemented a rigorous 10-repeated fivefold patient-level cross-validation strategy combined with hierarchical random undersampling. A pre-trained AlexNet architecture was utilized strictly as a robust feature extractor (via the fc8 layer) without fine-tuning. The extracted 1000-dimensional semantic features were subsequently classified using Support Vector Machine (SVM) and K-Nearest Neighbor (KNN) algorithms. Under strict patient-level isolation across 50 independent training-testing cycles, the SVM classifier achieved an average accuracy of 83.03%, sensitivity of 81.74%, specificity of 84.29%, F1-score of 82.32%, and an area under the curve (AUC) of 91.93%. The KNN classifier yielded an average accuracy of 80.56% and an AUC of 87.66%. By effectively overcoming data leakage and bias, this study demonstrates the true generalization capability of deep feature extraction in distinguishing IPF from fibrotic HP. The proposed framework provides a highly robust and reliable non-invasive decision-support tool for challenging diagnostic scenarios.
- 17 April 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
A Hybrid Approach for Differentiating Fibrotic Hypersensitivity Pneumonitis and Idiopathic Pulmonary Fibrosis: Deep Feature Extraction and Machine Learning
In patients over 60 years of age who are male, non-smokers, and in whom no organic antigen is identified in the history, differentiating fibrotic hypersensitivity pneumonitis (HP) from idiopathic pulmonary fibrosis (IPF) may be challenging. We aimed to evaluate the contribution of deep learning-based feature extraction and machine learning classification in differentiating these two pathologies, which exhibit similar radiological patterns on high-resolution computed tomography (HRCT) images. The study retrospectively included 87 patients (52 IPF, 35 HP). To completely eliminate data leakage and class imbalance-common methodological flaws in medical AI-we implemented a rigorous 10-repeated fivefold patient-level cross-validation strategy combined with hierarchical random undersampling. A pre-trained AlexNet architecture was utilized strictly as a robust feature extractor (via the fc8 layer) without fine-tuning. The extracted 1000-dimensional semantic features were subsequently classified using Support Vector Machine (SVM) and K-Nearest Neighbor (KNN) algorithms. Under strict patient-level isolation across 50 independent training-testing cycles, the SVM classifier achieved an average accuracy of 83.03%, sensitivity of 81.74%, specificity of 84.29%, F1-score of 82.32%, and an area under the curve (AUC) of 91.93%. The KNN classifier yielded an average accuracy of 80.56% and an AUC of 87.66%. By effectively overcoming data leakage and bias, this study demonstrates the true generalization capability of deep feature extraction in distinguishing IPF from fibrotic HP. The proposed framework provides a highly robust and reliable non-invasive decision-support tool for challenging diagnostic scenarios.
- Open Access
- 23 June 2025
- Published by Hitit University in Hitit Medical Journal
- Vol. 7 (2) , 188-197
Contribution to Diagnosis of Microflow Imaging in Breast Lesions
Objective: In recent years, the cancer detection rate in breast biopsies varies between 10-31%. Appropriate classification is required to prevent unnecessary biopsies in breast lesions. The aim of our study is to investigate the contribution of microflow imaging to the diagnosis of benign and malignant breast lesions. Material and Method: After local ethics committee approval, 109 lesions of 104 patients older than 18 years were prospectively included in the study. B-mode ultrasonography, color Doppler ultrasonography, power Doppler ultrasonography and microflow imaging were performed on all patients. B-mode ultrasonography findings were classified according to the BI-RADS category, color Doppler ultrasonography, power Doppler ultrasonography and microflow imaging findings were classified according to the ADLER method. Sensitivity, specificity, negative predictive values and positive predictive values of Doppler ultrasonographic methods were calculated. Results: Histopathologically, 68 of the breast lesions were benign and 41 were malignant. There was a statistically significant difference between benign and malignant lesions on power Doppler ultrasonography and microflow imaging. Negative predictive values were higher than positive predictive values on Doppler ultrasonography examination methods. Doppler ultrasonography examinations were found to be more likely to identify malignant lesions. Conclusion: Vascular findings on power Doppler ultrasonography and microflow imaging can be used as criteria to differentiate benign from malignant breast lesions. Thus, benign breast lesions can be monitored and unnecessary biopsies can be prevented.
- 23 June 2025
- Published by Hitit University in Hitit Medical Journal
- Vol. 7 (2) , 188-197
Open AccessContribution to Diagnosis of Microflow Imaging in Breast Lesions
Objective: In recent years, the cancer detection rate in breast biopsies varies between 10-31%. Appropriate classification is required to prevent unnecessary biopsies in breast lesions. The aim of our study is to investigate the contribution of microflow imaging to the diagnosis of benign and malignant breast lesions. Material and Method: After local ethics committee approval, 109 lesions of 104 patients older than 18 years were prospectively included in the study. B-mode ultrasonography, color Doppler ultrasonography, power Doppler ultrasonography and microflow imaging were performed on all patients. B-mode ultrasonography findings were classified according to the BI-RADS category, color Doppler ultrasonography, power Doppler ultrasonography and microflow imaging findings were classified according to the ADLER method. Sensitivity, specificity, negative predictive values and positive predictive values of Doppler ultrasonographic methods were calculated. Results: Histopathologically, 68 of the breast lesions were benign and 41 were malignant. There was a statistically significant difference between benign and malignant lesions on power Doppler ultrasonography and microflow imaging. Negative predictive values were higher than positive predictive values on Doppler ultrasonography examination methods. Doppler ultrasonography examinations were found to be more likely to identify malignant lesions. Conclusion: Vascular findings on power Doppler ultrasonography and microflow imaging can be used as criteria to differentiate benign from malignant breast lesions. Thus, benign breast lesions can be monitored and unnecessary biopsies can be prevented.
- 6 December 2024
- Published by Springer Nature in Neurological Sciences
- Vol. 46 (4) , 1721-1732
Magnetic resonance imaging findings of cerebral venous malformations
Purpose Our study aimed to evaluate the incidence and anatomical locations of cerebral venous malformations (CVMs), their alterations over time, and magnetic resonance imaging (MRI) findings of their relationships with each other in patients who underwent magnetic susceptibility-weighted imaging (SWI) and contrast-enhanced MRI. Methods The drainage pattern of developmental venous anomalies (DVAs), the number of collecting veins, DVA thrombosis, signal-intensity abnormalities, and hemosiderin deposits (nodular, diffuse, or both) related to the DVA, were examined. The alterations over time in cavernomas (type and size) were assessed. Results The study evaluated 7,826 patients who had 8,957 magnetic SWI and contrast-enhanced brain MRIs. A total of 643 CVMs were detected in 520 patients. The frequencies of DVAs, cavernomas, and capillary telangiectasias were 5.26%, 1.28%, and 0.62%, respectively. Isolated DVAs were detected in 430 (71.5%), cavernomas in 77 (12.8%), and capillary telangiectasias in 52 (8.7%) cases of CVMs. The coexistence of DVA with cavernoma and DVA with capillary telangiectasia was found in 38 (6.3%) and 4 (0.7%) cases, respectively. DVA drainage was largely provided by a single collecting vein. Signal-intensity abnormalities associated with the DVA were observed in 7, and two patients had DVA thrombosis. Hemosiderin deposits were nodular in 14 cases, diffuse in three, and both nodular and diffuse in two. In a follow-up of 11 (7.8%) cavernomas, alterations in the type and size were detected. Conclusion It is not uncommon for cavernomas to become symptomatic owing to alterations in their nature, size, and type over time, while DVAs rarely become symptomatic. Capillary telangiectasias are vascular malformations that tend to remain stable in terms of clinical and imaging features, and those with supratentorial localization are detected more frequently in the frontal lobe. On magnetic susceptibility sequences, hemosiderin deposits can be seen in the GVA region, not rarely but more frequently in nodular form, as well as in diffuse or nodular or diffuse and nodular forms.
- 6 December 2024
- Published by Springer Nature in Neurological Sciences
- Vol. 46 (4) , 1721-1732
Magnetic resonance imaging findings of cerebral venous malformations
Purpose Our study aimed to evaluate the incidence and anatomical locations of cerebral venous malformations (CVMs), their alterations over time, and magnetic resonance imaging (MRI) findings of their relationships with each other in patients who underwent magnetic susceptibility-weighted imaging (SWI) and contrast-enhanced MRI. Methods The drainage pattern of developmental venous anomalies (DVAs), the number of collecting veins, DVA thrombosis, signal-intensity abnormalities, and hemosiderin deposits (nodular, diffuse, or both) related to the DVA, were examined. The alterations over time in cavernomas (type and size) were assessed. Results The study evaluated 7,826 patients who had 8,957 magnetic SWI and contrast-enhanced brain MRIs. A total of 643 CVMs were detected in 520 patients. The frequencies of DVAs, cavernomas, and capillary telangiectasias were 5.26%, 1.28%, and 0.62%, respectively. Isolated DVAs were detected in 430 (71.5%), cavernomas in 77 (12.8%), and capillary telangiectasias in 52 (8.7%) cases of CVMs. The coexistence of DVA with cavernoma and DVA with capillary telangiectasia was found in 38 (6.3%) and 4 (0.7%) cases, respectively. DVA drainage was largely provided by a single collecting vein. Signal-intensity abnormalities associated with the DVA were observed in 7, and two patients had DVA thrombosis. Hemosiderin deposits were nodular in 14 cases, diffuse in three, and both nodular and diffuse in two. In a follow-up of 11 (7.8%) cavernomas, alterations in the type and size were detected. Conclusion It is not uncommon for cavernomas to become symptomatic owing to alterations in their nature, size, and type over time, while DVAs rarely become symptomatic. Capillary telangiectasias are vascular malformations that tend to remain stable in terms of clinical and imaging features, and those with supratentorial localization are detected more frequently in the frontal lobe. On magnetic susceptibility sequences, hemosiderin deposits can be seen in the GVA region, not rarely but more frequently in nodular form, as well as in diffuse or nodular or diffuse and nodular forms.
- Open Access
- 30 June 2024
- Published by Hitit University in Hitit Medical Journal
- Vol. 6 (2) , 208-215
The Impact of Nasal Septum Deviation on Paranasal Sinus Volumes
Objective: Researchers have extensively investigated the reasons behind variations in the volumes of paranasal sinuses, either among different individuals or between the right and left sides of the same individual. These differences in volumes have been associated with nasal septal deviation (NSD) and anatomical variations. In this study, we aimed to retrospectively analyzed the effect of NSD on frontal sinus, maxillary sinus, and sphenoidal sinus. Material and Method: A total of 281 patients (151 females and 130 males) admitted to Gaziosmanpaşa University Hospital were included in the study. Paranasal sinus computed tomography (CT) images consisting of 0.625-mm-thick slices were obtained from the patients. The areas of the frontal sinus, maxillary sinus, and sphenoidal sinus were determined using ImageJ software. The volume of each sinus was calculated using Cavalieri’s principle. We analyzed the relationship between the calculated volumes and nasal septal deviation. Results: Our study found that the frontal sinus volume values were 4.67 cm³ on the right side and 5.03 cm³ on the left side in women. In men, the right-side volume value was 7.07 cm³ and the left-side volume value was 7.77 cm³. The sphenoidal sinus volume value was calculated as 6.35 cm³ on the right side and 6.57 cm³ on the left side in women. In males, the right-side volume value was 7.34 cm³ and the left-side volume value was 7.62 cm³. The maxillary sinus volume was calculated as 19.38 cm³ on the right side and 19.37 cm³ on the left side in women. In males, the right-side volume value was 22.80 cm³ and the left-side volume value was 23.71 cm³. The frontal sinus volume values in males were larger than those in females (p=0.04). The maxillary sinus volume values in males were greater than the maxillary sinus volume values in females (p=0.02). There was no significant relationship between the presence of septal deviation and sinus volumes (p>0.05). The right, left, or s-shaped deviation direction did not cause a significant difference in sinus volumes (p>0.05). Conclusion: The findings show that there is no correlation between volume values and the presence and shape of nasal septal deviation. However, significant differences in volumes were observed between the genders. Because the severity of nasal septal deviation is related to the volume value, different results can be obtained by measuring the frontal sinus, maxillary sinus, and sphenoidal sinus volume values in individuals with more advanced deviation.
- 30 June 2024
- Published by Hitit University in Hitit Medical Journal
- Vol. 6 (2) , 208-215
Open AccessThe Impact of Nasal Septum Deviation on Paranasal Sinus Volumes
Objective: Researchers have extensively investigated the reasons behind variations in the volumes of paranasal sinuses, either among different individuals or between the right and left sides of the same individual. These differences in volumes have been associated with nasal septal deviation (NSD) and anatomical variations. In this study, we aimed to retrospectively analyzed the effect of NSD on frontal sinus, maxillary sinus, and sphenoidal sinus. Material and Method: A total of 281 patients (151 females and 130 males) admitted to Gaziosmanpaşa University Hospital were included in the study. Paranasal sinus computed tomography (CT) images consisting of 0.625-mm-thick slices were obtained from the patients. The areas of the frontal sinus, maxillary sinus, and sphenoidal sinus were determined using ImageJ software. The volume of each sinus was calculated using Cavalieri’s principle. We analyzed the relationship between the calculated volumes and nasal septal deviation. Results: Our study found that the frontal sinus volume values were 4.67 cm³ on the right side and 5.03 cm³ on the left side in women. In men, the right-side volume value was 7.07 cm³ and the left-side volume value was 7.77 cm³. The sphenoidal sinus volume value was calculated as 6.35 cm³ on the right side and 6.57 cm³ on the left side in women. In males, the right-side volume value was 7.34 cm³ and the left-side volume value was 7.62 cm³. The maxillary sinus volume was calculated as 19.38 cm³ on the right side and 19.37 cm³ on the left side in women. In males, the right-side volume value was 22.80 cm³ and the left-side volume value was 23.71 cm³. The frontal sinus volume values in males were larger than those in females (p=0.04). The maxillary sinus volume values in males were greater than the maxillary sinus volume values in females (p=0.02). There was no significant relationship between the presence of septal deviation and sinus volumes (p>0.05). The right, left, or s-shaped deviation direction did not cause a significant difference in sinus volumes (p>0.05). Conclusion: The findings show that there is no correlation between volume values and the presence and shape of nasal septal deviation. However, significant differences in volumes were observed between the genders. Because the severity of nasal septal deviation is related to the volume value, different results can be obtained by measuring the frontal sinus, maxillary sinus, and sphenoidal sinus volume values in individuals with more advanced deviation.
- Open Access
- 29 March 2024
- Published by Pera Yayıncılık Hizmetleri in European Journal of Therapeutics
- Vol. 30 (3) , 258-266
Evaluation of Automated Mammographic Density Classification in Tomosynthesis: Comparison with Radiologists
Objective: Breast cancer screening is a valuable field of health research conducted through mammography. However, mammography evaluation is the examination with the most frequent lack of to agrement among radiologists. In this study we aimed to show the compatibility of mammographic density classification with a new software, Bellus Breast Density Measurement Software (Option), with visual examination. Methods: The mammographic density classification of 500 patients was retrospectively determined by five radiologists with varying levels of experience, according to the 5th version of the breast imaging reporting and data system (BIRADS). The mean age of 500 women included in the study was calculated as 53.8±10.08. The obtained data were compared with the Bellus software mammographic density classification of the same patients. Then, the visual evaluation and the compatibility of the Bellus software and the readers were compared. Results: The agreement between the Bellus software and all five readers was poor (kappa value 0.07-0.12). The agreement of the readers with each other is moderate-good (kappa value 0.054-0.64). The Intraclass Correlation Coefficient (ICC) value for the five separate readers was calculated to be 0.80, indicating good compatibility, while the ICC value for the Bellus software with the five separate readers was calculated to be 0.74, indicating moderate compatibility. The Friedman test revealed that while the mammographic density classification of each reader remained consistent, the classification provided by the Bellus software differed. Conclusion: Bellus Breast Density Measurement Software (Option) diagnostic accuracy is lower than visual examination. We recommend that the manufacturer develop the software.
- 29 March 2024
- Published by Pera Yayıncılık Hizmetleri in European Journal of Therapeutics
- Vol. 30 (3) , 258-266
Open AccessEvaluation of Automated Mammographic Density Classification in Tomosynthesis: Comparison with Radiologists
Objective: Breast cancer screening is a valuable field of health research conducted through mammography. However, mammography evaluation is the examination with the most frequent lack of to agrement among radiologists. In this study we aimed to show the compatibility of mammographic density classification with a new software, Bellus Breast Density Measurement Software (Option), with visual examination. Methods: The mammographic density classification of 500 patients was retrospectively determined by five radiologists with varying levels of experience, according to the 5th version of the breast imaging reporting and data system (BIRADS). The mean age of 500 women included in the study was calculated as 53.8±10.08. The obtained data were compared with the Bellus software mammographic density classification of the same patients. Then, the visual evaluation and the compatibility of the Bellus software and the readers were compared. Results: The agreement between the Bellus software and all five readers was poor (kappa value 0.07-0.12). The agreement of the readers with each other is moderate-good (kappa value 0.054-0.64). The Intraclass Correlation Coefficient (ICC) value for the five separate readers was calculated to be 0.80, indicating good compatibility, while the ICC value for the Bellus software with the five separate readers was calculated to be 0.74, indicating moderate compatibility. The Friedman test revealed that while the mammographic density classification of each reader remained consistent, the classification provided by the Bellus software differed. Conclusion: Bellus Breast Density Measurement Software (Option) diagnostic accuracy is lower than visual examination. We recommend that the manufacturer develop the software.
- Open Access
- 1 June 2023
- Published by SelSistem in Journal of Surgery and Medicine
- Vol. 7 (6) , 00
Radiological approach to multinodular and vacuolating neuronal tumor: Two case report
Multinodular and vacuolating neuronal tumors (MVNT) are indolent, low-grade, superficial neuronal tumors of the cerebrum that consist only of neuronal cells in adults. They were first reported in 2013 by Huse et al. and defined by the World Health Organization in 2016. MVNT is characterized by vacuolated tumor nodules with glial and/or neuronal differentiation histopathologically. MVNT is most commonly located in the temporal lobe. Radiologically, it has a subcortical, soap-bubble morphology, sometimes extending to the cortex, and is almost as hyperintense as cerebrospinal fluid on T2-weighted images. Its signal is not suppressed on the FLAIR sequence, and there is no diffusion restriction on diffusion-weighted images. Usually, there is no enhancement after gadolinium injections, but a few reports show weak enhancement in the literature. In the first case, we present a 22-year-old female with MVNT who underwent MRI for a complaint of dizziness which was detected incidentally. MRI showed a clustered multinodular lesion in the left superior frontal gyrus that was hyperintense on T2-weighted/FLAIR series and isointense with gray matter on T1-weighted images. There was no diffusion restriction or contrast enhancement on MRI. In the second case, a 51-year-old female with complaints of numbness and pain in her left arm had an MRI that showed a lesion in the right cerebral hemisphere at the temporoparietal junction. The lesion did not cause edema or mass effect and was distributed in the cortical-subcortical area. The lesion was hyperintense in T2-weighted and FLAIR series and consisted of many millimetric nodular components in close intensity with gray matter in the T1-weighted series. No contrast enhancement was detected. Knowing the characteristic imaging findings of MVNT is important in avoiding aggressive diagnosis and treatment approaches in asymptomatic cases. In conclusion, MVNT is a newly identified tumor that appears hyperintense on the FLAIR sequence and should not be operated on. '+st+' Gökçe E. Magnetic resonance imaging findings of two cases with multinodular and vacuolating neuronal tumor. Acta Neurol Belg. 2020;120(2):457-61. DOI: https://doi.org/10.1007/s13760-017-0872-x Nunes RH, Hsu CC, da Rocha AJ, do Amaral LLF, Godoy LFS, Watkins TW, et al. Multinodular and vacuolating neuronal tumor of the cerebrum: a new “leave me alone” lesion with a characteristic imaging pattern. AJNR Am J Neuroradiol. 2017;38(10):1899-904. DOI: https://doi.org/10.3174/ajnr.A5281 Louis DN, Perry A, Reifenberger G, Von Deimling A, Figarella-Branger D, Cavenee WK, et al. The 2016 World Health Organization classification of tumors of the central nervous system: a summary. Acta Neuropathol. 2016;131(6):803-20. DOI: https://doi.org/10.1007/s00401-016-1545-1 Thom M, Liu J, Bongaarts A, Reinten RJ, Paradiso B, Jäger HR, et al. Multinodular and vacuolating neuronal tumors in epilepsy: dysplasia or neoplasia? Brain Pathol. 2018;28(2):155-71. DOI: https://doi.org/10.1111/bpa.12555 Alsufayan R, Alcaide-Leon P, De Tilly LN, Mandell DM, Krings T. Natural history of lesions with the MR imaging appearance of multinodular and vacuolating neuronal tumor. Neuroradiology. 2017;59(9):873-83. DOI: https://doi.org/10.1007/s00234-017-1884-1 Huse JT, Edgar M, Halliday J, Mikolaenko I, Lavi E, Rosenblum MK. Multinodular and vacuolating neuronal tumors of the cerebrum: 10 cases of a distinctive seizure‐associated lesion. Brain Pathol. 2013;23(5):515-24. DOI: https://doi.org/10.1111/bpa.12035 Fukushima S, Yoshida A, Narita Y, Arita H, Ohno M, Miyakita Y, et al. Multinodular and vacuolating neuronal tumor of the cerebrum. Brain Tumor Pathol. 2015;32(2):131-6. DOI: https://doi.org/10.1007/s10014-014-0198-9 Bodi I, Curran O, Selway R, Elwes R, Burrone J, Laxton R, et al. Two cases of multinodular and vacuolating neuronal tumour. Acta Neuropathol Commun. 2014;2(1):1-10. DOI: https://doi.org/10.1186/2051-5960-2-7 De Wandeler T, De Brucker Y, Jansen A, Vanderhasselt T. Multinodular and vacuolating neuronal tumor of the cerebrum (MVNT): do not touch. Acta Neurol Belg. 2020;120(3):747-8. DOI: https://doi.org/10.1007/s13760-019-01157-9 Yamaguchi M, Komori T, Nakata Y, Yagishita A, Morino M, Isozaki E. Multinodular and vacuolating neuronal tumor affecting amygdala and hippocampus: a quasi‐tumor? Pathol Int. 2016;66(1):34-41. DOI: https://doi.org/10.1111/pin.12366 Agarwal A, Lakshmanan R, Devagnanam I, Bynevelt M. Multinodular and Vacuolating Neuronal Tumor of the Cerebrum: Does the Name Require Review? AJNR Am J Neuroradiol. 2019;40(12):69-70. DOI: https://doi.org/10.3174/ajnr.A6284 Becker AJ, Wiestler OD, Figarella-Branger D, Blumcke I. Ganglioglioma and gangliocytoma. In: Louis DN, Ohgaki H, Wiestler OD, Cavenee WK, editors. WHO Classification of Tumours of the Central Nervous System. 4th ed. Lyon: International Agency for Research on Cancer; 2007. pp. 103–5. Daumas-Duport C, Varlet P. Dysembryoplastic neuroepithelial tumors. Rev Neurol. 2003;159:622-36. Meroni A, Galli C, Bramerio M, Tassi L, Colombo N, Cossu M, et al. Nodular heterotopia: a neuropathological study of 24 patients undergoing surgery for drug‐resistant epilepsy. Epilepsia. 2009;50(1):116-24. DOI: https://doi.org/10.1111/j.1528-1167.2008.01717.x Copyright (c) 2023 Şükrüye Firuze Ocak Karataş, Murat Beyhan, Erkan Gökçe This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
- 1 June 2023
- Published by SelSistem in Journal of Surgery and Medicine
- Vol. 7 (6) , 00
Open AccessRadiological approach to multinodular and vacuolating neuronal tumor: Two case report
Multinodular and vacuolating neuronal tumors (MVNT) are indolent, low-grade, superficial neuronal tumors of the cerebrum that consist only of neuronal cells in adults. They were first reported in 2013 by Huse et al. and defined by the World Health Organization in 2016. MVNT is characterized by vacuolated tumor nodules with glial and/or neuronal differentiation histopathologically. MVNT is most commonly located in the temporal lobe. Radiologically, it has a subcortical, soap-bubble morphology, sometimes extending to the cortex, and is almost as hyperintense as cerebrospinal fluid on T2-weighted images. Its signal is not suppressed on the FLAIR sequence, and there is no diffusion restriction on diffusion-weighted images. Usually, there is no enhancement after gadolinium injections, but a few reports show weak enhancement in the literature. In the first case, we present a 22-year-old female with MVNT who underwent MRI for a complaint of dizziness which was detected incidentally. MRI showed a clustered multinodular lesion in the left superior frontal gyrus that was hyperintense on T2-weighted/FLAIR series and isointense with gray matter on T1-weighted images. There was no diffusion restriction or contrast enhancement on MRI. In the second case, a 51-year-old female with complaints of numbness and pain in her left arm had an MRI that showed a lesion in the right cerebral hemisphere at the temporoparietal junction. The lesion did not cause edema or mass effect and was distributed in the cortical-subcortical area. The lesion was hyperintense in T2-weighted and FLAIR series and consisted of many millimetric nodular components in close intensity with gray matter in the T1-weighted series. No contrast enhancement was detected. Knowing the characteristic imaging findings of MVNT is important in avoiding aggressive diagnosis and treatment approaches in asymptomatic cases. In conclusion, MVNT is a newly identified tumor that appears hyperintense on the FLAIR sequence and should not be operated on. '+st+' Gökçe E. Magnetic resonance imaging findings of two cases with multinodular and vacuolating neuronal tumor. Acta Neurol Belg. 2020;120(2):457-61. DOI: https://doi.org/10.1007/s13760-017-0872-x Nunes RH, Hsu CC, da Rocha AJ, do Amaral LLF, Godoy LFS, Watkins TW, et al. Multinodular and vacuolating neuronal tumor of the cerebrum: a new “leave me alone” lesion with a characteristic imaging pattern. AJNR Am J Neuroradiol. 2017;38(10):1899-904. DOI: https://doi.org/10.3174/ajnr.A5281 Louis DN, Perry A, Reifenberger G, Von Deimling A, Figarella-Branger D, Cavenee WK, et al. The 2016 World Health Organization classification of tumors of the central nervous system: a summary. Acta Neuropathol. 2016;131(6):803-20. DOI: https://doi.org/10.1007/s00401-016-1545-1 Thom M, Liu J, Bongaarts A, Reinten RJ, Paradiso B, Jäger HR, et al. Multinodular and vacuolating neuronal tumors in epilepsy: dysplasia or neoplasia? Brain Pathol. 2018;28(2):155-71. DOI: https://doi.org/10.1111/bpa.12555 Alsufayan R, Alcaide-Leon P, De Tilly LN, Mandell DM, Krings T. Natural history of lesions with the MR imaging appearance of multinodular and vacuolating neuronal tumor. Neuroradiology. 2017;59(9):873-83. DOI: https://doi.org/10.1007/s00234-017-1884-1 Huse JT, Edgar M, Halliday J, Mikolaenko I, Lavi E, Rosenblum MK. Multinodular and vacuolating neuronal tumors of the cerebrum: 10 cases of a distinctive seizure‐associated lesion. Brain Pathol. 2013;23(5):515-24. DOI: https://doi.org/10.1111/bpa.12035 Fukushima S, Yoshida A, Narita Y, Arita H, Ohno M, Miyakita Y, et al. Multinodular and vacuolating neuronal tumor of the cerebrum. Brain Tumor Pathol. 2015;32(2):131-6. DOI: https://doi.org/10.1007/s10014-014-0198-9 Bodi I, Curran O, Selway R, Elwes R, Burrone J, Laxton R, et al. Two cases of multinodular and vacuolating neuronal tumour. Acta Neuropathol Commun. 2014;2(1):1-10. DOI: https://doi.org/10.1186/2051-5960-2-7 De Wandeler T, De Brucker Y, Jansen A, Vanderhasselt T. Multinodular and vacuolating neuronal tumor of the cerebrum (MVNT): do not touch. Acta Neurol Belg. 2020;120(3):747-8. DOI: https://doi.org/10.1007/s13760-019-01157-9 Yamaguchi M, Komori T, Nakata Y, Yagishita A, Morino M, Isozaki E. Multinodular and vacuolating neuronal tumor affecting amygdala and hippocampus: a quasi‐tumor? Pathol Int. 2016;66(1):34-41. DOI: https://doi.org/10.1111/pin.12366 Agarwal A, Lakshmanan R, Devagnanam I, Bynevelt M. Multinodular and Vacuolating Neuronal Tumor of the Cerebrum: Does the Name Require Review? AJNR Am J Neuroradiol. 2019;40(12):69-70. DOI: https://doi.org/10.3174/ajnr.A6284 Becker AJ, Wiestler OD, Figarella-Branger D, Blumcke I. Ganglioglioma and gangliocytoma. In: Louis DN, Ohgaki H, Wiestler OD, Cavenee WK, editors. WHO Classification of Tumours of the Central Nervous System. 4th ed. Lyon: International Agency for Research on Cancer; 2007. pp. 103–5. Daumas-Duport C, Varlet P. Dysembryoplastic neuroepithelial tumors. Rev Neurol. 2003;159:622-36. Meroni A, Galli C, Bramerio M, Tassi L, Colombo N, Cossu M, et al. Nodular heterotopia: a neuropathological study of 24 patients undergoing surgery for drug‐resistant epilepsy. Epilepsia. 2009;50(1):116-24. DOI: https://doi.org/10.1111/j.1528-1167.2008.01717.x Copyright (c) 2023 Şükrüye Firuze Ocak Karataş, Murat Beyhan, Erkan Gökçe This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
- 1 April 2023
- Published by Galenos Yayinevi in Türk Radyoloji Seminerleri
- Vol. 11 (1) , 53-60
Osmotik Demiyelinizasyon Sendromu
- 1 April 2023
- Published by Galenos Yayinevi in Türk Radyoloji Seminerleri
- Vol. 11 (1) , 53-60
Osmotik Demiyelinizasyon Sendromu
- Open Access
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Revista da Associação Médica Brasileira
- Vol. 69 (12) , e20230297
Evaluation of respiratory bronchiolitis nodules with maximum intensity projection images
Respiratory bronchiolitis is a disease associated with heavy smoking. Computed tomography in this disease often shows symmetrical and bilaterally ill-defined circumscribed centriacinar micronodular involvement in the upper-middle lobes. The maximum intensity projection method is a kind of image processing method and provides a better evaluation of nodules and vascular structures. Our study aimed to show whether maximum intensity projection images increase the diagnostic accuracy in the detection of micronodules in respiratory bronchiolitis.
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Revista da Associação Médica Brasileira
- Vol. 69 (12) , e20230297
Open AccessEvaluation of respiratory bronchiolitis nodules with maximum intensity projection images
Respiratory bronchiolitis is a disease associated with heavy smoking. Computed tomography in this disease often shows symmetrical and bilaterally ill-defined circumscribed centriacinar micronodular involvement in the upper-middle lobes. The maximum intensity projection method is a kind of image processing method and provides a better evaluation of nodules and vascular structures. Our study aimed to show whether maximum intensity projection images increase the diagnostic accuracy in the detection of micronodules in respiratory bronchiolitis.