Olivier Sutter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Olivier Sutter has a total of 127 co-authors. Here are the top co-authors by number of shared publications:
Olivier Seror
AIMOKA: INRIA, Assistance Publique-Hôpitaux de Paris, Université Sorbonne Paris-Nord, F-35042 Rennes, France
6 shared publicationsArthur Petit
Interventional Radiology Unit, Hôpital Avicenne, Hôpitaux Universitaires Paris Seine-Saint-Denis, APHP, Bobigny, France
5 shared publicationsClair Poignard
AIMOKA: INRIA, Assistance Publique-Hôpitaux de Paris, Université Sorbonne Paris-Nord, F-35042 Rennes, France
3 shared publications- Claudia Campani
Centre de Recherche des Cordeliers 1 Sorbonne Université, Inserm, Paris, France
3 shared publications Gisèle N’kOntchou
Hepatology Department, Avicenne Hospital (APHP)
3 shared publicationsJean-Charles Nault
Hepatology Department, Avicenne Hospital (APHP)
3 shared publications
Latest Publications
- 29 April 2026
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 282, 109408
Hybrid learning/numerical framework for fast and robust electric field simulation in irreversible electroporation
- 29 April 2026
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 282, 109408
Hybrid learning/numerical framework for fast and robust electric field simulation in irreversible electroporation
- 9 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Numerical study of liver tumor ablation by electroporation
Etude numérique des ablations par électroporation des tumeurs hépatiques: L'électroporation irréversible (IRE) est une technique d’ablation non thermique actuellement utilisée comme option curative de “dernier recours” pour des cancers profonds, non résécables chirurgicalement et contre-indiquées à une ablation thermique en raison de leur proximité avec des structures anatomiques vitales. Le principe de l’IRE consiste à délivrer de multiples impulsions électriques de haute tension et de très courte durée à l’aide de plusieurs électrodes (au moins trois, mais souvent quatre à six) insérées autour de la tumeur sous guidage radiologique. La répétition de ces impulsions induit une perméabilisation irréversible des membranes des cellules, conduisant à leur apoptose, sans endommager la matrice extracellulaire. Malgré ce mécanisme spécifique, l’efficacité clinique de l’IRE reste inférieure à celle d’autres options thérapeutiques, et plusieurs défis doivent être relevés pour améliorer les résultats cliniques. Premièrement, l’IRE nécessite un positionnement très précis de plusieurs électrodes autour de la tumeur cible, souvent difficile à atteindre par voie percutanée en raison de sa localisation profonde dans le foie. Le schéma d’implantation des électrodes doit être optimisé afin de garantir une couverture adéquate de la tumeur par le champ électrique. Toutefois, l’efficacité du traitement n’est actuellement évaluée qu’a posteriori, et aucun critère d’évaluation peropératoire n’est disponible pour assister les radiologues interventionnels durant la procédure. Deuxièmement, Les tissus traités sont par définition un milieu conducteur hétérogène au minimum du fait de la présence d’une tumeur, mais aussi par la composition de l’organe sous-jacent, ainsi que la présence d’éventuelles structures adjacentes. Cette hétérogénéité influence la distribution et l’intensité du champ électrique et doit probablement être intégrée dans les modèles numérique. Enfin, la récidive tumorale restant fréquente après IRE, le suivi post-opératoire, reposant principalement sur l’imagerie par résonance magnétique (IRM), doit être mieux compris et corrélé aux données peropératoires. L’objectif de cette thèse était d’adapter et d’affiner la modélisation numérique de l’IRE pour une évaluation peri-opératoire du traitement des tumeurs hépatiques. À travers quatre études complémentaires, nous proposons des méthodes numériques basées sur des stratégies avancées de recalage d’images, de modélisation mathématique et des simulations informées par les résultats cliniques, afin de progresser vers une évaluation numérique en temps réel de l’efficacité de l’IRE.
- 9 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Numerical study of liver tumor ablation by electroporation
Etude numérique des ablations par électroporation des tumeurs hépatiques: L'électroporation irréversible (IRE) est une technique d’ablation non thermique actuellement utilisée comme option curative de “dernier recours” pour des cancers profonds, non résécables chirurgicalement et contre-indiquées à une ablation thermique en raison de leur proximité avec des structures anatomiques vitales. Le principe de l’IRE consiste à délivrer de multiples impulsions électriques de haute tension et de très courte durée à l’aide de plusieurs électrodes (au moins trois, mais souvent quatre à six) insérées autour de la tumeur sous guidage radiologique. La répétition de ces impulsions induit une perméabilisation irréversible des membranes des cellules, conduisant à leur apoptose, sans endommager la matrice extracellulaire. Malgré ce mécanisme spécifique, l’efficacité clinique de l’IRE reste inférieure à celle d’autres options thérapeutiques, et plusieurs défis doivent être relevés pour améliorer les résultats cliniques. Premièrement, l’IRE nécessite un positionnement très précis de plusieurs électrodes autour de la tumeur cible, souvent difficile à atteindre par voie percutanée en raison de sa localisation profonde dans le foie. Le schéma d’implantation des électrodes doit être optimisé afin de garantir une couverture adéquate de la tumeur par le champ électrique. Toutefois, l’efficacité du traitement n’est actuellement évaluée qu’a posteriori, et aucun critère d’évaluation peropératoire n’est disponible pour assister les radiologues interventionnels durant la procédure. Deuxièmement, Les tissus traités sont par définition un milieu conducteur hétérogène au minimum du fait de la présence d’une tumeur, mais aussi par la composition de l’organe sous-jacent, ainsi que la présence d’éventuelles structures adjacentes. Cette hétérogénéité influence la distribution et l’intensité du champ électrique et doit probablement être intégrée dans les modèles numérique. Enfin, la récidive tumorale restant fréquente après IRE, le suivi post-opératoire, reposant principalement sur l’imagerie par résonance magnétique (IRM), doit être mieux compris et corrélé aux données peropératoires. L’objectif de cette thèse était d’adapter et d’affiner la modélisation numérique de l’IRE pour une évaluation peri-opératoire du traitement des tumeurs hépatiques. À travers quatre études complémentaires, nous proposons des méthodes numériques basées sur des stratégies avancées de recalage d’images, de modélisation mathématique et des simulations informées par les résultats cliniques, afin de progresser vers une évaluation numérique en temps réel de l’efficacité de l’IRE.
- Open Access
- 10 February 2026
- Published by Elsevier in Journal of Hepatology
- Vol. 84 (6) , 1149-1163
Detection of esophageal varices and prediction of hepatic decompensation in unresectable hepatocellular carcinoma using AI
- 10 February 2026
- Published by Elsevier in Journal of Hepatology
- Vol. 84 (6) , 1149-1163
Open AccessDetection of esophageal varices and prediction of hepatic decompensation in unresectable hepatocellular carcinoma using AI
- 19 December 2025
- Published by Springer Nature in European Radiology
- Vol. 36 (5) , 3589-3600
Toward perioperative, numerically assisted irreversible electroporation for hepatocellular carcinoma: clinical outcomes informed by numerical simulations
Objectives Numerical evaluation of irreversible electroporation (IRE) holds significant potential to assist practitioners in planning and guiding these complex procedures. We aimed to establish a correlation between the results of retrospective numerical simulations of IRE and clinical outcomes in the treatment of hepatocellular carcinoma (HCC). Materials and methods IRE procedures conducted at our center for HCCs < 5 cm were reconstructed. Per-procedural imaging was used to generate a 3D geometric model of the tumor and its surroundings. The spatial coordinates of electrodes and treatment parameters were used to retrospectively simulate the EF using the static linear model. The proportion of tumor volume encompassed by 3D mappings of different EF magnitudes was correlated with clinical efficacy using a logistic regression algorithm. Results 31 IRE procedures were included. HCCs had a median diameter of 20 mm (range: 7–45 mm). At 1 month, 29/31 tumors (93.5%) showed complete ablation, but 10 of these recurred later (median delay: 7 months). The percentages of tumor coverage by EF isolines were significantly lower in the 12 cases of local IRE failure compared to the 19 cases of IRE success: 97.7% vs. 100% at 300 V/cm (p < 0.001); 89.7% vs. 100% at 400 V/cm (p < 0.001) and 82.8% vs. 95.4% at 500 V/cm (p < 0.01) with 400 V/cm being the most discriminative threshold dose (ROC-AUC: 0.904). Tumor coverage < 95% by the 400 V/cm isoline was associated with IRE failure (2-year incidence: 89% vs. 21.7%, p < 0.0001). Conclusion Numerical simulations of IRE correlate with local treatment outcomes. This study suggests that, in HCC, inadequate tumor coverage by the 400 V/cm isoline predicts and localizes recurrence. Key Points Question Can the clinical outcomes of irreversible electroporation for hepatocellular carcinoma be predicted using numerical simulation of the electric field (EF) distribution? Findings Inadequate tumor coverage by simulated EF maps predicts and localizes recurrence, with 400 V/cm being the most discriminative isodose threshold (ROC-AUC > 0.9). Clinical relevance Numerical simulations of the electric field correlate with local treatment outcomes of irreversible electroporation for hepatocellular carcinoma within a computational framework compatible with clinical use. Real-time identification of insufficient tumor coverage can enable operators to adapt and optimize treatment delivery. Graphical Abstract
- 19 December 2025
- Published by Springer Nature in European Radiology
- Vol. 36 (5) , 3589-3600
Toward perioperative, numerically assisted irreversible electroporation for hepatocellular carcinoma: clinical outcomes informed by numerical simulations
Objectives Numerical evaluation of irreversible electroporation (IRE) holds significant potential to assist practitioners in planning and guiding these complex procedures. We aimed to establish a correlation between the results of retrospective numerical simulations of IRE and clinical outcomes in the treatment of hepatocellular carcinoma (HCC). Materials and methods IRE procedures conducted at our center for HCCs < 5 cm were reconstructed. Per-procedural imaging was used to generate a 3D geometric model of the tumor and its surroundings. The spatial coordinates of electrodes and treatment parameters were used to retrospectively simulate the EF using the static linear model. The proportion of tumor volume encompassed by 3D mappings of different EF magnitudes was correlated with clinical efficacy using a logistic regression algorithm. Results 31 IRE procedures were included. HCCs had a median diameter of 20 mm (range: 7–45 mm). At 1 month, 29/31 tumors (93.5%) showed complete ablation, but 10 of these recurred later (median delay: 7 months). The percentages of tumor coverage by EF isolines were significantly lower in the 12 cases of local IRE failure compared to the 19 cases of IRE success: 97.7% vs. 100% at 300 V/cm (p < 0.001); 89.7% vs. 100% at 400 V/cm (p < 0.001) and 82.8% vs. 95.4% at 500 V/cm (p < 0.01) with 400 V/cm being the most discriminative threshold dose (ROC-AUC: 0.904). Tumor coverage < 95% by the 400 V/cm isoline was associated with IRE failure (2-year incidence: 89% vs. 21.7%, p < 0.0001). Conclusion Numerical simulations of IRE correlate with local treatment outcomes. This study suggests that, in HCC, inadequate tumor coverage by the 400 V/cm isoline predicts and localizes recurrence. Key Points Question Can the clinical outcomes of irreversible electroporation for hepatocellular carcinoma be predicted using numerical simulation of the electric field (EF) distribution? Findings Inadequate tumor coverage by simulated EF maps predicts and localizes recurrence, with 400 V/cm being the most discriminative isodose threshold (ROC-AUC > 0.9). Clinical relevance Numerical simulations of the electric field correlate with local treatment outcomes of irreversible electroporation for hepatocellular carcinoma within a computational framework compatible with clinical use. Real-time identification of insufficient tumor coverage can enable operators to adapt and optimize treatment delivery. Graphical Abstract
- Open Access
- 7 November 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (22) , 225010
Correlation between computed electric dose maps and early post-operative MRI for the evaluation of irreversible electroporation
Objective. To correlate numerical simulations of the electric dose distribution with early post-operative MRI following irreversible electroporation (IRE) treatment of hepatocellular carcinoma (HCC). Approach. A standard linear electrostatic model was employed to simulate the three-dimensional electric field (EF) distribution using real electric pulses and geometrical characteristics and intraoperative cone-beam CT (CBCT) data. Spatial registration between intraoperative CBCT and post-operative MRI was performed using both rigid and deformable methods, ranging from simple global translations based on anatomical landmarks to advanced deformable image registration (DIR) techniques accounting for elastic tissue deformations. Main results. The proposed approach was retrospectively evaluated using data from 22 patients who underwent IRE liver ablation (one patient underwent two distinct IRE procedures), resulting in a total of 23 procedures. The most accurate correspondence between predicted and observed ablation zones was achieved using a dose threshold of approximately 350 V cm −1 , yielding a median dice similarity coefficient around 0.74, indicative of substantial spatial overlap. Although elastic DIR approaches applied to segmented liver regions provided the highest registration accuracy, the simpler translational registration based on manually selected landmarks demonstrated surprisingly robust performance in localizing the simulated EF within the actual ablation zone. Significance. These findings contribute to the standardization of IRE efficacy assessment on MRI and highlight the significant potential EF simulations to predict the extent of tissue ablation in IRE procedures for HCC. This approach may offer a valuable tool for improving intraoperative decision-making and post-operative assessment.
- 7 November 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (22) , 225010
Open AccessCorrelation between computed electric dose maps and early post-operative MRI for the evaluation of irreversible electroporation
Objective. To correlate numerical simulations of the electric dose distribution with early post-operative MRI following irreversible electroporation (IRE) treatment of hepatocellular carcinoma (HCC). Approach. A standard linear electrostatic model was employed to simulate the three-dimensional electric field (EF) distribution using real electric pulses and geometrical characteristics and intraoperative cone-beam CT (CBCT) data. Spatial registration between intraoperative CBCT and post-operative MRI was performed using both rigid and deformable methods, ranging from simple global translations based on anatomical landmarks to advanced deformable image registration (DIR) techniques accounting for elastic tissue deformations. Main results. The proposed approach was retrospectively evaluated using data from 22 patients who underwent IRE liver ablation (one patient underwent two distinct IRE procedures), resulting in a total of 23 procedures. The most accurate correspondence between predicted and observed ablation zones was achieved using a dose threshold of approximately 350 V cm −1 , yielding a median dice similarity coefficient around 0.74, indicative of substantial spatial overlap. Although elastic DIR approaches applied to segmented liver regions provided the highest registration accuracy, the simpler translational registration based on manually selected landmarks demonstrated surprisingly robust performance in localizing the simulated EF within the actual ablation zone. Significance. These findings contribute to the standardization of IRE efficacy assessment on MRI and highlight the significant potential EF simulations to predict the extent of tissue ablation in IRE procedures for HCC. This approach may offer a valuable tool for improving intraoperative decision-making and post-operative assessment.
- Open Access
- 28 May 2025
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 42 (1) , 2505595
The role of early MRI in assessing the risk of local tumor progression following irreversible electroporation for hepatocellular carcinoma treatment
Irreversible electroporation (IRE) in hepatocellular carcinoma (HCC) triggers apoptosis instead of thermal coagulation, resulting in specific modifications within ablation zones. Aim of this study is to evaluate the diagnostic value of MRI performed three days post-IRE (D3MRI). This single-institution retrospective study examined patients with HCC treated by IRE from 2012-2017. Criteria included no prior HCC treatment, available D3MRI and one-month MRI (M1MRI) without residual tumor and at least one follow-up MRI after 3 months. We measured the peripheral hyperemia (IREPZ) and central necrotic zone (IRECZ) in the ablation area along with the minimum thickness of IREPZ (min.Th/IREPZ) on both D3MRI and M1MRI. The duration of follow-up and instances of local tumor progression (LTP) were recorded. Forty-eight patients (median age: 68 years) with 65 treated nodules (median diameter: 19 mm) were included. The median follow-up was 37 months. D3MRI median dimensions were 67 mm for IREPZ, 19 mm for IRECZ, and 5 mm for min.Th/IREPZ. LTP occurred in 25 nodules after 18 months. 52% had LTP at min.Th/IREPZ. A min.Th/IREPZ ≤ 5 mm on D3MRI indicated a 24-fold higher risk of LTP (95% CI [2.25-255.95], p < .01), conversely, the min.Th/IREPZ on M1MRI had no predictive value. D3MRI appears to be a valuable tool for assessing the true ablation margins in HCC nodules treated with IRE and for identifying potential sites of local recurrence. It may, therefore, be considered for integration into the follow-up protocol for patients undergoing IRE treatment for HCC.
- 28 May 2025
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 42 (1) , 2505595
Open AccessThe role of early MRI in assessing the risk of local tumor progression following irreversible electroporation for hepatocellular carcinoma treatment
Irreversible electroporation (IRE) in hepatocellular carcinoma (HCC) triggers apoptosis instead of thermal coagulation, resulting in specific modifications within ablation zones. Aim of this study is to evaluate the diagnostic value of MRI performed three days post-IRE (D3MRI). This single-institution retrospective study examined patients with HCC treated by IRE from 2012-2017. Criteria included no prior HCC treatment, available D3MRI and one-month MRI (M1MRI) without residual tumor and at least one follow-up MRI after 3 months. We measured the peripheral hyperemia (IREPZ) and central necrotic zone (IRECZ) in the ablation area along with the minimum thickness of IREPZ (min.Th/IREPZ) on both D3MRI and M1MRI. The duration of follow-up and instances of local tumor progression (LTP) were recorded. Forty-eight patients (median age: 68 years) with 65 treated nodules (median diameter: 19 mm) were included. The median follow-up was 37 months. D3MRI median dimensions were 67 mm for IREPZ, 19 mm for IRECZ, and 5 mm for min.Th/IREPZ. LTP occurred in 25 nodules after 18 months. 52% had LTP at min.Th/IREPZ. A min.Th/IREPZ ≤ 5 mm on D3MRI indicated a 24-fold higher risk of LTP (95% CI [2.25-255.95], p < .01), conversely, the min.Th/IREPZ on M1MRI had no predictive value. D3MRI appears to be a valuable tool for assessing the true ablation margins in HCC nodules treated with IRE and for identifying potential sites of local recurrence. It may, therefore, be considered for integration into the follow-up protocol for patients undergoing IRE treatment for HCC.
- Open Access
- 22 April 2025
- Published by Elsevier in JHEP Reports
- Vol. 7 (9) , 101430
Utility of tumor and non-tumor biopsies during percutaneous radiofrequency ablation for hepatocellular carcinoma
- 22 April 2025
- Published by Elsevier in JHEP Reports
- Vol. 7 (9) , 101430
Open AccessUtility of tumor and non-tumor biopsies during percutaneous radiofrequency ablation for hepatocellular carcinoma
- Top Cited PapersOpen Access
- 17 April 2025
- Published by Elsevier in Journal of Hepatology
- Vol. 83 (4) , 959-970
Machine learning based radiomic models outperform clinical biomarkers in predicting outcomes after immunotherapy for hepatocellular carcinoma
- 17 April 2025
- Published by Elsevier in Journal of Hepatology
- Vol. 83 (4) , 959-970
Top Cited PapersOpen AccessMachine learning based radiomic models outperform clinical biomarkers in predicting outcomes after immunotherapy for hepatocellular carcinoma
- 14 March 2025
- Published by Wiley in Liver International
- Vol. 45 (4) , e16153
AI ‐Based Prognostic Stratification in HCC , Towards a Personalised Treatment Approach
- 14 March 2025
- Published by Wiley in Liver International
- Vol. 45 (4) , e16153
AI ‐Based Prognostic Stratification in HCC , Towards a Personalised Treatment Approach
- 9 February 2024
- Published by Springer Nature in European Radiology
- Vol. 34 (9) , 5529-5540
Incidence and clinical impact of bile ducts changes after multibipolar radiofrequency ablation for hepatocellular carcinoma
Objectives This study aimed to evaluate the incidence and clinical implications of bile duct changes following multibipolar radiofrequency ablation (mbpRFA) for hepatocellular carcinoma (HCC). Materials and methods Radiological, clinical, and biological data from consecutive cirrhotic patients who underwent first-line mbpRFA between 2007 and 2014 for uninodular HCC ≤ 5 cm were retrospectively collected. Follow-up imaging was reviewed to identify bile duct changes and factors associated with biliary changes were assessed using multivariable analysis. Baseline and 6-month liver function tests were compared in patients with and without bile duct changes. Complications, cirrhosis decompensation, and survival rates were compared in both groups. Results A total of 231 patients (mean age 68 years [39-85], 187 men) underwent 266 mbpRFA sessions for uninodular HCC (mean size 26 mm). Of these, 76 (33%) developed bile duct changes (upstream bile duct dilatations and/or bilomas) with a mean onset time of 3 months. Identified risk factors for these changes were the infiltrative aspect of the tumor (p = 0.035) and its location in segment VIII (p < 0.01). The average increase in bilirubin at 6 months was higher in the group with biliary changes (+2.9 vs. +0.4 µg/mL; p = 0.03). There were no significant differences in terms of complications, cirrhosis decompensation at 1 year (p = 0.95), local and distant tumor progression (p = 0.91 and 0.14 respectively), and overall survival (p = 0.4) between the two groups. Conclusion Bile duct changes are common after mbpRFA for HCC, especially in tumors with an infiltrative aspect or those located in segment VIII. These changes do not appear to negatively impact the course of cirrhosis at 1 year or overall survival. Clinical relevance statement Bile duct changes following mbpRFA for HCC are relatively common. Nevertheless, they do not raise clinical concerns in terms of complications, deterioration in liver function, or survival rates. Consequently, specific monitoring or interventions for these bile duct changes are not warranted. Key Points • Bile duct changes are frequently observed after multibipolar radiofrequency ablation for hepatocellular carcinoma, occurring in 33% of cases in our study. • Patients with bile duct changes exhibited a higher increase in bilirubin levels at 6 months but no more cirrhosis decompensation or liver abscesses. • Biliary changes following multibipolar radiofrequency ablation for hepatocellular carcinoma are not alarming and do not necessitate any specific monitoring or intervention. Graphical abstract
- 9 February 2024
- Published by Springer Nature in European Radiology
- Vol. 34 (9) , 5529-5540
Incidence and clinical impact of bile ducts changes after multibipolar radiofrequency ablation for hepatocellular carcinoma
Objectives This study aimed to evaluate the incidence and clinical implications of bile duct changes following multibipolar radiofrequency ablation (mbpRFA) for hepatocellular carcinoma (HCC). Materials and methods Radiological, clinical, and biological data from consecutive cirrhotic patients who underwent first-line mbpRFA between 2007 and 2014 for uninodular HCC ≤ 5 cm were retrospectively collected. Follow-up imaging was reviewed to identify bile duct changes and factors associated with biliary changes were assessed using multivariable analysis. Baseline and 6-month liver function tests were compared in patients with and without bile duct changes. Complications, cirrhosis decompensation, and survival rates were compared in both groups. Results A total of 231 patients (mean age 68 years [39-85], 187 men) underwent 266 mbpRFA sessions for uninodular HCC (mean size 26 mm). Of these, 76 (33%) developed bile duct changes (upstream bile duct dilatations and/or bilomas) with a mean onset time of 3 months. Identified risk factors for these changes were the infiltrative aspect of the tumor (p = 0.035) and its location in segment VIII (p < 0.01). The average increase in bilirubin at 6 months was higher in the group with biliary changes (+2.9 vs. +0.4 µg/mL; p = 0.03). There were no significant differences in terms of complications, cirrhosis decompensation at 1 year (p = 0.95), local and distant tumor progression (p = 0.91 and 0.14 respectively), and overall survival (p = 0.4) between the two groups. Conclusion Bile duct changes are common after mbpRFA for HCC, especially in tumors with an infiltrative aspect or those located in segment VIII. These changes do not appear to negatively impact the course of cirrhosis at 1 year or overall survival. Clinical relevance statement Bile duct changes following mbpRFA for HCC are relatively common. Nevertheless, they do not raise clinical concerns in terms of complications, deterioration in liver function, or survival rates. Consequently, specific monitoring or interventions for these bile duct changes are not warranted. Key Points • Bile duct changes are frequently observed after multibipolar radiofrequency ablation for hepatocellular carcinoma, occurring in 33% of cases in our study. • Patients with bile duct changes exhibited a higher increase in bilirubin levels at 6 months but no more cirrhosis decompensation or liver abscesses. • Biliary changes following multibipolar radiofrequency ablation for hepatocellular carcinoma are not alarming and do not necessitate any specific monitoring or intervention. Graphical abstract