Patrick Michael Carl Rourke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Patrick Michael Carl Rourke has a total of 151 co-authors. Here are the top co-authors by number of shared publications:
A. McCollam
Department of Physics, University of Toronto, Toronto, Ontario M5S 1A7, Canada
6 shared publicationsJ. Flouquet
DRFMC, SPSMS, CEA Grenoble, 17 rue des Martyrs, 3805-4 Grenoble Cedex 9, France
4 shared publicationsN. E. Hussey
High Field Magnet Laboratory (HFML-EMFL), Radboud University, Toernooiveld 7, 6525 ED Nijmegen, Nijmegen, The Netherlands
4 shared publicationsS. R. Julian
Department of Physics University of Toronto M5S 1A7 Toronto ON Canada
4 shared publicationsA. F. Bangura
3 shared publications- Antony Carrington
University of Bristol
3 shared publications
Latest Publications
- Open Access
- 15 January 2026
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 384 (2312)
The redefined kelvin—progress and prospects
- 15 January 2026
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 384 (2312)
Open AccessThe redefined kelvin—progress and prospects
- Open Access
- 15 January 2026
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 384 (2312)
The triad of trust: solutions to practical inconsistencies in T , T 90 and in situ traceability
The 2019 redefinition of the kelvin and its accompanying Mise en pratique (MeP-K) herald a bold new future for the thermometry community. The MeP-K offers a blueprint for putting the kelvin into practice, and the proliferation of the new realization options it enables will lead to both benefits and practical inconsistencies for thermometer users. Users have been accustomed to a straightforward International Temperature Scale of 1990 T90 measurement chain with traceability and trust assured by national metrology institutes (NMIs). In contrast, the emerging world of coexisting T and T90 thermometers, with some offering in situ temperature traceability unconnected to NMIs, will challenge this straightforward measurement chain. Here, we discuss practical solutions to the practical inconsistencies users will encounter. These solutions focus on the triad of trust in metrology—traceability, equivalence and competence—to allow thermometry end users to broadly benefit from new technologies while maintaining trust in measurements and minimizing net disruption. This article is part of the Theo Murphy meeting issue ‘The redefined kelvin: progress and prospects’.
- 15 January 2026
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 384 (2312)
Open AccessThe triad of trust: solutions to practical inconsistencies in T , T 90 and in situ traceability
The 2019 redefinition of the kelvin and its accompanying Mise en pratique (MeP-K) herald a bold new future for the thermometry community. The MeP-K offers a blueprint for putting the kelvin into practice, and the proliferation of the new realization options it enables will lead to both benefits and practical inconsistencies for thermometer users. Users have been accustomed to a straightforward International Temperature Scale of 1990 T90 measurement chain with traceability and trust assured by national metrology institutes (NMIs). In contrast, the emerging world of coexisting T and T90 thermometers, with some offering in situ temperature traceability unconnected to NMIs, will challenge this straightforward measurement chain. Here, we discuss practical solutions to the practical inconsistencies users will encounter. These solutions focus on the triad of trust in metrology—traceability, equivalence and competence—to allow thermometry end users to broadly benefit from new technologies while maintaining trust in measurements and minimizing net disruption. This article is part of the Theo Murphy meeting issue ‘The redefined kelvin: progress and prospects’.
- Open Access
- 15 January 2026
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 384 (2312)
Quantum technology: prospects for new thermometric and radiometric sensor development
In the perspective, some new methods for measuring thermodynamic (or primary) temperature that exploit quantum effects are discussed. The techniques discussed are at various stages of development, so for each, the principles of operation, current and anticipated challenges and current status and progress are presented. First, the development of a thermometer based on cavity magnomechanics for cryogenic applications is discussed. This technique links temperature to a signal derived from the phonon modes in a magnetic element coupled to a microwave cavity. Second, progress in Coulomb blockade thermometry is discussed. Advances in the manipulation of atoms using scanning probe microscopy (SPM) have led to the creation of structures, such as single-electron transistors (SETs), with physical dimensions smaller than can be achieved using traditional lithography. A Coulomb blockade thermometer (CBT) fabricated at such small scales could operate at higher temperatures than previously demonstrated. Third, Rydberg thermal radiometry is discussed. The excited states of Rydberg atoms possess large dipole moments and interact strongly with blackbody radiation (BBR). Rydberg radiometry leverages these interactions to infer a source’s temperature from the effect of its emitted BBR upon the quantum dynamics of Rydberg states. Fourth, thermometry via temperature-dependent optical emission from nanoparticles is discussed, which is expected to be particularly useful for biological applications; in addition, efforts are underway to achieve primary thermometry by this mechanism. This article is part of the Theo Murphy meeting issue ‘The redefined kelvin: progress and prospects’.
- 15 January 2026
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 384 (2312)
Open AccessQuantum technology: prospects for new thermometric and radiometric sensor development
In the perspective, some new methods for measuring thermodynamic (or primary) temperature that exploit quantum effects are discussed. The techniques discussed are at various stages of development, so for each, the principles of operation, current and anticipated challenges and current status and progress are presented. First, the development of a thermometer based on cavity magnomechanics for cryogenic applications is discussed. This technique links temperature to a signal derived from the phonon modes in a magnetic element coupled to a microwave cavity. Second, progress in Coulomb blockade thermometry is discussed. Advances in the manipulation of atoms using scanning probe microscopy (SPM) have led to the creation of structures, such as single-electron transistors (SETs), with physical dimensions smaller than can be achieved using traditional lithography. A Coulomb blockade thermometer (CBT) fabricated at such small scales could operate at higher temperatures than previously demonstrated. Third, Rydberg thermal radiometry is discussed. The excited states of Rydberg atoms possess large dipole moments and interact strongly with blackbody radiation (BBR). Rydberg radiometry leverages these interactions to infer a source’s temperature from the effect of its emitted BBR upon the quantum dynamics of Rydberg states. Fourth, thermometry via temperature-dependent optical emission from nanoparticles is discussed, which is expected to be particularly useful for biological applications; in addition, efforts are underway to achieve primary thermometry by this mechanism. This article is part of the Theo Murphy meeting issue ‘The redefined kelvin: progress and prospects’.
- 25 August 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 127 (8)
Cryogenic magnomechanics for thermometry applications
Cavity magnomechanics combines strong coupling between magnons in a dielectric material and microwave cavity photons with long-lived mechanical resonances. Forming a triple resonance condition, this hybrid quantum system promises many advantages in quantum technologies, yet has never been studied at the cryogenic temperatures required to reveal such quantum properties. We report the observation of magnomechanics at cryogenic temperatures down to 9 K. The experiment was conducted using a yttrium iron garnet sphere inside a microwave cavity, where we measured both the thermomechanical motion and the temperature-dependence of the magnon linewidth.
- 25 August 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 127 (8)
Cryogenic magnomechanics for thermometry applications
Cavity magnomechanics combines strong coupling between magnons in a dielectric material and microwave cavity photons with long-lived mechanical resonances. Forming a triple resonance condition, this hybrid quantum system promises many advantages in quantum technologies, yet has never been studied at the cryogenic temperatures required to reveal such quantum properties. We report the observation of magnomechanics at cryogenic temperatures down to 9 K. The experiment was conducted using a yttrium iron garnet sphere inside a microwave cavity, where we measured both the thermomechanical motion and the temperature-dependence of the magnon linewidth.
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 020006
Future of the international temperature scale in a mixed dissemination environment
The International Temperature Scale of 1990 (ITS-90) has successfully underpinned thermometry worldwide for more than three decades. But times are changing. Pri The International Temperature Scale of 1990 (ITS-90) has successfully underpinned thermometry worldwide for more than three decades. But times are changing. Pri
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 020006
Future of the international temperature scale in a mixed dissemination environment
The International Temperature Scale of 1990 (ITS-90) has successfully underpinned thermometry worldwide for more than three decades. But times are changing. Pri The International Temperature Scale of 1990 (ITS-90) has successfully underpinned thermometry worldwide for more than three decades. But times are changing. Pri
- Open Access
- 1 December 2022
- Published by AIP Publishing in Journal of Physical and Chemical Reference Data
- Vol. 51 (4) , 043105
2022 Update for the Differences Between Thermodynamic Temperature and ITS-90 Below 335 K
In 2011, a working group of the Consultative Committee for Thermometry published their best estimates of the differences between the thermodynamic temperature T and its approximation (T90), the temperature according to the International Temperature Scale of 1990, ITS-90. These consensus estimates, in combination with measurements made in accordance with ITS-90, are an important alternative to primary thermometry for those requiring accurate measurements of thermodynamic temperature. Since 2011, there has been a change in the definition of the kelvin and significant improvements in primary thermometry. This paper updates the (T − T90) estimates by combining and analyzing the data used for the 2011 estimates and data from more recent primary thermometry. The results of the analysis are presented as a 12th-order polynomial representing the updated consensus values for the differences and a sixth-order polynomial for their uncertainty estimates.
- 1 December 2022
- Published by AIP Publishing in Journal of Physical and Chemical Reference Data
- Vol. 51 (4) , 043105
Open Access2022 Update for the Differences Between Thermodynamic Temperature and ITS-90 Below 335 K
In 2011, a working group of the Consultative Committee for Thermometry published their best estimates of the differences between the thermodynamic temperature T and its approximation (T90), the temperature according to the International Temperature Scale of 1990, ITS-90. These consensus estimates, in combination with measurements made in accordance with ITS-90, are an important alternative to primary thermometry for those requiring accurate measurements of thermodynamic temperature. Since 2011, there has been a change in the definition of the kelvin and significant improvements in primary thermometry. This paper updates the (T − T90) estimates by combining and analyzing the data used for the 2011 estimates and data from more recent primary thermometry. The results of the analysis are presented as a 12th-order polynomial representing the updated consensus values for the differences and a sixth-order polynomial for their uncertainty estimates.
- 1 September 2021
- Published by AIP Publishing in Journal of Physical and Chemical Reference Data
- Vol. 50 (3) , 033104
Perspective on the Refractive-Index Gas Metrology Data Landscape
The redefinition of the kelvin has increased focus on thermometry techniques that use the newly fixed value of the Boltzmann constant to realize thermodynamic temperature. One such technique that has advanced considerably in recent years is refractive-index gas thermometry. Generalized as refractive-index gas metrology (RIGM), this also includes a range of applications outside of temperature realizations, such as pressure standards and measurements of the physical properties of gases. Here, the current data situation in the field is reviewed, encompassing the latest developments and remaining challenges, in order to suggest possible approaches for reducing RIGM uncertainties and improving RIGM applications. New analyses of existing experimental literature data are presented for the second density virial coefficient Bρ of helium, neon, argon, and nitrogen; the third density virial coefficient Cρ of nitrogen; and the third dielectric virial coefficient Cε of helium, neon, and argon. A need is identified for more accurate reference-quality datasets to be measured or calculated in several areas, with robust uncertainty budgets, to support future RIGM advancements. The most urgent of these are the bulk modulus of copper; thermodynamic accuracy of the International Temperature Scale of 1990; molar optical refractivity AR of neon, argon, and nitrogen; diamagnetic susceptibility χ0 of neon and argon; second density virial coefficient Bρ of argon; third dielectric virial coefficient Cε of helium, neon, and argon; and third optical refractivity virial coefficient CR of helium and neon.
- 1 September 2021
- Published by AIP Publishing in Journal of Physical and Chemical Reference Data
- Vol. 50 (3) , 033104
Perspective on the Refractive-Index Gas Metrology Data Landscape
The redefinition of the kelvin has increased focus on thermometry techniques that use the newly fixed value of the Boltzmann constant to realize thermodynamic temperature. One such technique that has advanced considerably in recent years is refractive-index gas thermometry. Generalized as refractive-index gas metrology (RIGM), this also includes a range of applications outside of temperature realizations, such as pressure standards and measurements of the physical properties of gases. Here, the current data situation in the field is reviewed, encompassing the latest developments and remaining challenges, in order to suggest possible approaches for reducing RIGM uncertainties and improving RIGM applications. New analyses of existing experimental literature data are presented for the second density virial coefficient Bρ of helium, neon, argon, and nitrogen; the third density virial coefficient Cρ of nitrogen; and the third dielectric virial coefficient Cε of helium, neon, and argon. A need is identified for more accurate reference-quality datasets to be measured or calculated in several areas, with robust uncertainty budgets, to support future RIGM advancements. The most urgent of these are the bulk modulus of copper; thermodynamic accuracy of the International Temperature Scale of 1990; molar optical refractivity AR of neon, argon, and nitrogen; diamagnetic susceptibility χ0 of neon and argon; second density virial coefficient Bρ of argon; third dielectric virial coefficient Cε of helium, neon, and argon; and third optical refractivity virial coefficient CR of helium and neon.
- 5 August 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (5) , 055004
ITS-90 reproducibility, xenon fixed point substitution and new interpolating equations between 13.8033 K and 273.16 K
- 5 August 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (5) , 055004
ITS-90 reproducibility, xenon fixed point substitution and new interpolating equations between 13.8033 K and 273.16 K
- 26 May 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (3) , 035003
Standard platinum resistance thermometer interpolations in a revised temperature scale
The thermal metrology community is considering revising the International Temperature Scale of 1990 (ITS-90), motivated by the opportunity to improve the thermodynamic accuracy, reproducibility, and ease of use of the scale, as well as health and safety concerns with the use of mercury in the current scale. This paper considers the mathematical structure of the standard platinum resistance thermometer (SPRT) interpolations of the ITS-90 and identifies (i) mathematical features that are advantageous and should be retained, (ii) opportunities for improvements, and (iii) the research required to maximise the benefits from such improvements. The improvements considered include minor adjustments that leave ITS-90 intact, numerical adjustments to reference resistance ratios that preserve the structure of ITS-90, fixed-point replacements, new subranges, and large-scale changes in the mathematical structure of the interpolations. A significant research effort will be required to implement some of the changes. Overall, an improvement in the thermodynamic accuracy by a factor of about ten is relatively easily realised, but improvements in reproducibility of the scale of even a couple of tens of percent will be hard won. For most users, the costs and inconvenience of a substantial scale revision may outweigh the benefits.
- 26 May 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (3) , 035003
Standard platinum resistance thermometer interpolations in a revised temperature scale
The thermal metrology community is considering revising the International Temperature Scale of 1990 (ITS-90), motivated by the opportunity to improve the thermodynamic accuracy, reproducibility, and ease of use of the scale, as well as health and safety concerns with the use of mercury in the current scale. This paper considers the mathematical structure of the standard platinum resistance thermometer (SPRT) interpolations of the ITS-90 and identifies (i) mathematical features that are advantageous and should be retained, (ii) opportunities for improvements, and (iii) the research required to maximise the benefits from such improvements. The improvements considered include minor adjustments that leave ITS-90 intact, numerical adjustments to reference resistance ratios that preserve the structure of ITS-90, fixed-point replacements, new subranges, and large-scale changes in the mathematical structure of the interpolations. A significant research effort will be required to implement some of the changes. Overall, an improvement in the thermodynamic accuracy by a factor of about ten is relatively easily realised, but improvements in reproducibility of the scale of even a couple of tens of percent will be hard won. For most users, the costs and inconvenience of a substantial scale revision may outweigh the benefits.
- 12 February 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (2) , 024001
Thermodynamic temperature of the triple point of xenon measured by refractive index gas thermometry
- 12 February 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (2) , 024001
Thermodynamic temperature of the triple point of xenon measured by refractive index gas thermometry