Jia Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jia Shi has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Jinchun Song
4 shared publicationsBin Song
Singapore Institute of Manufacturing Technology
2 shared publications- Bin Wu
State Key Laboratory of Materials Processing and Die & Mould Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, People’s Republic of China
2 shared publications - Bin Yang
Xi’an University of Science and Technology
1 shared publication Dieter Trau
Department of Biomedical Engineering, National University of Singapore, Singapore, Singapore
1 shared publicationJia Shi
1 shared publication
Latest Publications
- 20 June 2022
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 14 (30) , 10761-10772
A deep learning-based framework for automatic analysis of the nanoparticle morphology in SEM/TEM images
A novel and smart three-stage framework having a powerful and light-weight NSNet to conduct high-throughput online real-time analysis of the nanoparticle morphology in complex SEM/TEM images.
- 20 June 2022
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 14 (30) , 10761-10772
A deep learning-based framework for automatic analysis of the nanoparticle morphology in SEM/TEM images
A novel and smart three-stage framework having a powerful and light-weight NSNet to conduct high-throughput online real-time analysis of the nanoparticle morphology in complex SEM/TEM images.
- Open Access
- 1 June 2019
- Published by Elsevier in Engineering
- Vol. 5 (3) , 586-593
Multi-Objective Optimization Design through Machine Learning for Drop-on-Demand Bioprinting
- 1 June 2019
- Published by Elsevier in Engineering
- Vol. 5 (3) , 586-593
Open AccessMulti-Objective Optimization Design through Machine Learning for Drop-on-Demand Bioprinting
- 1 May 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 154, 368-379
An improved series-parallel optimization approach for cooling water system
- 1 May 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 154, 368-379
An improved series-parallel optimization approach for cooling water system
- 13 June 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (4) , 045028
Shear stress analysis and its effects on cell viability and cell proliferation in drop-on-demand bioprinting
Bioprinting has emerged as a flexible technology in tissue engineering to mimic biological and functional organizational complexity of native tissues. Drop-on-Demand (DoD) bioprinting is one of the most promising technologies currently due to the unique characteristics of high-throughput efficiency and cost-effectiveness. Despite these significant advantages, DoD bioprinting has some drawbacks, including loss of cell viability impacted by shear stress. However, there are only very few studies discussed the variation of shear stress in DoD cell printing and its effects on cell behaviours. In this paper, a CFD simulation model of piezoelectric DoD print-head was developed to study shear stress in the nozzle during printing. Experiments were conducted to study the effect of shear stress on cell viability and cell proliferation. The mathematical model of piezoelectric effect is developed with CFD model to improve the simulation accuracy. Parametric studies on shear stress were also carried out. Simulation results demonstrated that (1) shear stress has a dramatic variation around the nozzle orifice mainly during the rise time and the following dwell time of voltage pulse in the episode; (2) the backflow fluid pushed the fluid entered from the inlet flowing down along the wall, increasing the wall shear stress simultaneously; (3) voltage, viscosity and nozzle diameter have important effects on both values and the effect range of shear stress. With simulation results of shear stress, experiments showed that both cell viability and cell proliferation are decreased with the increase of shear stress, whereby shear stress has a larger influence on cell proliferation than on cell viability. Through the proposed simulation model, the computed shear stress during DoD bioprinting is able to link with engineering characteristics, such as printing parameters, and cell characteristics, such as cell viability and cell proliferation. The simulation model can be used to improve cell viability and cell proliferation through optimizing printing parameters to decrease shear stress in piezoelectric DoD bioprinting.
- 13 June 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (4) , 045028
Shear stress analysis and its effects on cell viability and cell proliferation in drop-on-demand bioprinting
Bioprinting has emerged as a flexible technology in tissue engineering to mimic biological and functional organizational complexity of native tissues. Drop-on-Demand (DoD) bioprinting is one of the most promising technologies currently due to the unique characteristics of high-throughput efficiency and cost-effectiveness. Despite these significant advantages, DoD bioprinting has some drawbacks, including loss of cell viability impacted by shear stress. However, there are only very few studies discussed the variation of shear stress in DoD cell printing and its effects on cell behaviours. In this paper, a CFD simulation model of piezoelectric DoD print-head was developed to study shear stress in the nozzle during printing. Experiments were conducted to study the effect of shear stress on cell viability and cell proliferation. The mathematical model of piezoelectric effect is developed with CFD model to improve the simulation accuracy. Parametric studies on shear stress were also carried out. Simulation results demonstrated that (1) shear stress has a dramatic variation around the nozzle orifice mainly during the rise time and the following dwell time of voltage pulse in the episode; (2) the backflow fluid pushed the fluid entered from the inlet flowing down along the wall, increasing the wall shear stress simultaneously; (3) voltage, viscosity and nozzle diameter have important effects on both values and the effect range of shear stress. With simulation results of shear stress, experiments showed that both cell viability and cell proliferation are decreased with the increase of shear stress, whereby shear stress has a larger influence on cell proliferation than on cell viability. Through the proposed simulation model, the computed shear stress during DoD bioprinting is able to link with engineering characteristics, such as printing parameters, and cell characteristics, such as cell viability and cell proliferation. The simulation model can be used to improve cell viability and cell proliferation through optimizing printing parameters to decrease shear stress in piezoelectric DoD bioprinting.
- 5 June 2018
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 46 (9) , 1267-1279
Learning-Based Cell Injection Control for Precise Drop-on-Demand Cell Printing
Drop-on-demand (DOD) printing is widely used in bioprinting for tissue engineering because of little damage to cell viability and cost-effectiveness. However, satellite droplets may be generated during printing, deviating cells from the desired position and affecting printing position accuracy. Current control on cell injection in DOD printing is primarily based on trial-and-error process, which is time-consuming and inflexible. In this paper, a novel machine learning technology based on Learning-based Cell Injection Control (LCIC) approach is demonstrated for effective DOD printing control while eliminating satellite droplets automatically. The LCIC approach includes a specific computational fluid dynamics (CFD) simulation model of piezoelectric DOD print-head considering inverse piezoelectric effect, which is used instead of repetitive experiments to collect data, and a multilayer perceptron (MLP) network trained by simulation data based on artificial neural network algorithm, using the well-known classification performance of MLP to optimize DOD printing parameters automatically. The test accuracy of the LCIC method was 90%. With the validation of LCIC method by experiments, satellite droplets from piezoelectric DOD printing are reduced significantly, improving the printing efficiency drastically to satisfy requirements of manufacturing precision for printing complex artificial tissues. The LCIC method can be further used to optimize the structure of DOD print-head and cell behaviors.
- 5 June 2018
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 46 (9) , 1267-1279
Learning-Based Cell Injection Control for Precise Drop-on-Demand Cell Printing
Drop-on-demand (DOD) printing is widely used in bioprinting for tissue engineering because of little damage to cell viability and cost-effectiveness. However, satellite droplets may be generated during printing, deviating cells from the desired position and affecting printing position accuracy. Current control on cell injection in DOD printing is primarily based on trial-and-error process, which is time-consuming and inflexible. In this paper, a novel machine learning technology based on Learning-based Cell Injection Control (LCIC) approach is demonstrated for effective DOD printing control while eliminating satellite droplets automatically. The LCIC approach includes a specific computational fluid dynamics (CFD) simulation model of piezoelectric DOD print-head considering inverse piezoelectric effect, which is used instead of repetitive experiments to collect data, and a multilayer perceptron (MLP) network trained by simulation data based on artificial neural network algorithm, using the well-known classification performance of MLP to optimize DOD printing parameters automatically. The test accuracy of the LCIC method was 90%. With the validation of LCIC method by experiments, satellite droplets from piezoelectric DOD printing are reduced significantly, improving the printing efficiency drastically to satisfy requirements of manufacturing precision for printing complex artificial tissues. The LCIC method can be further used to optimize the structure of DOD print-head and cell behaviors.