Spyridon E. Chalkiadakis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Spyridon E. Chalkiadakis has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Vasileios G. Peponis
Athens Eye Hospital, 2nd Eye Clinic, Athens, Greece
4 shared publications Efstratios A. Parikakis
Athens Eye Hospital, Athens, Greece
3 shared publicationsPanagiotis G. Mitropoulos
2nd Eye Clinic, Specialized Eye Hospital 'Ophthalmiatrion Athinon', Athens, Greece
3 shared publicationsV. Peponis
Athens Eye Hospital, Second Eye Clinic, Athens, Greece
2 shared publicationsVc Kyttaris
Division of Rheumatology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
2 shared publicationsApostolos Amariotakis
Athens Eye Hospital, 2nd Eye Clinic, Athens - Greece
1 shared publication
Latest Publications
- Open Access
- 16 September 2016
- Published by S. Karger AG in Case Reports in Ophthalmology
- Vol. 7 (3) , 433-439
Sutureless 25-Gauge Pars Plana Vitrectomy Combined with Retropupillary Fixation of an Iris-Claw Intraocular Lens
Background: The surgical case of a dropped intraocular lens inside the vitreous cavity constitutes a real challenge for the operating surgeon. Herein, we describe a case series where an alternative optical rehabilitation technique for late intraocular lens-bag complex dislocation has been used. Methods: A modern vitrectomy device was used to remove the capsule with the dropped intraocular lens using sutureless 25-gauge pars plana vitrectomy. To ensure a better aesthetic result, with faster patient recovery and a reduced number of operations, the whole procedure was performed during the same operating session; an iris-claw intraocular lens for aphakia was selected for implantation. The implant was passed behind the constricted iris with the concave surface facing it. The lens was grasped with the manufacturer’s holding forceps and fixed onto the posterior surface of the iris using the special enclavation needles. Results: We have operated 12 eyes in two different clinical centres successfully, with minimal intra- and/or postoperative complications. Conclusion: We believe that this is a viable solution for the visual rehabilitation of patients, who would otherwise need more than one operation for a lens exchange.
- 16 September 2016
- Published by S. Karger AG in Case Reports in Ophthalmology
- Vol. 7 (3) , 433-439
Open AccessSutureless 25-Gauge Pars Plana Vitrectomy Combined with Retropupillary Fixation of an Iris-Claw Intraocular Lens
Background: The surgical case of a dropped intraocular lens inside the vitreous cavity constitutes a real challenge for the operating surgeon. Herein, we describe a case series where an alternative optical rehabilitation technique for late intraocular lens-bag complex dislocation has been used. Methods: A modern vitrectomy device was used to remove the capsule with the dropped intraocular lens using sutureless 25-gauge pars plana vitrectomy. To ensure a better aesthetic result, with faster patient recovery and a reduced number of operations, the whole procedure was performed during the same operating session; an iris-claw intraocular lens for aphakia was selected for implantation. The implant was passed behind the constricted iris with the concave surface facing it. The lens was grasped with the manufacturer’s holding forceps and fixed onto the posterior surface of the iris using the special enclavation needles. Results: We have operated 12 eyes in two different clinical centres successfully, with minimal intra- and/or postoperative complications. Conclusion: We believe that this is a viable solution for the visual rehabilitation of patients, who would otherwise need more than one operation for a lens exchange.
- Open Access
- 2 November 2013
- Published by S. Karger AG in Case Reports in Ophthalmology
- Vol. 4 (3) , 219-228
Toric Intraocular Lens Implantation for Correction of Astigmatism in Cataract Patients with Corneal Ectasia
Our purpose was to examine the long-term efficacy of toric intraocular lens (IOL) implantation in cataract patients with high astigmatism due to corneal ectasia, who underwent phacoemulsification cataract surgery. Five eyes of 3 cataract patients with topographically stable keratoconus or pellucid macular degeneration (PMD), in which phacoemulsification with toric IOL implantation was used to correct high astigmatism, are reported. Objective and subjective refraction, visual acuity measurement and corneal topography were performed in all cases before and after cataract surgery. In all cases, there was a significant improvement in visual acuity, as well as refraction, which remained stable over time. Specifically, in subjective refraction, all patients achieved visual acuity from 7/10 to 9/10 with up to -2.50 cyl. Corneal topography also remained stable. Postoperative follow-up was 18-28 months. Cataract surgery with toric IOL implantation seems to be safe and effective in correcting astigmatism and improving visual function in cataract patients with topographically stable keratoconus or PMD.
- 2 November 2013
- Published by S. Karger AG in Case Reports in Ophthalmology
- Vol. 4 (3) , 219-228
Open AccessToric Intraocular Lens Implantation for Correction of Astigmatism in Cataract Patients with Corneal Ectasia
Our purpose was to examine the long-term efficacy of toric intraocular lens (IOL) implantation in cataract patients with high astigmatism due to corneal ectasia, who underwent phacoemulsification cataract surgery. Five eyes of 3 cataract patients with topographically stable keratoconus or pellucid macular degeneration (PMD), in which phacoemulsification with toric IOL implantation was used to correct high astigmatism, are reported. Objective and subjective refraction, visual acuity measurement and corneal topography were performed in all cases before and after cataract surgery. In all cases, there was a significant improvement in visual acuity, as well as refraction, which remained stable over time. Specifically, in subjective refraction, all patients achieved visual acuity from 7/10 to 9/10 with up to -2.50 cyl. Corneal topography also remained stable. Postoperative follow-up was 18-28 months. Cataract surgery with toric IOL implantation seems to be safe and effective in correcting astigmatism and improving visual function in cataract patients with topographically stable keratoconus or PMD.
- Open Access
- 1 July 2012
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 6, 1045-9
The effect of phacoemulsification on late bleb failure or intraocular pressure in patients with glaucoma: a systematic review
Peer reviewed article authored by (Peponis VG, Chalkiadakis SE, Katzakis MC, Parikakis EA). Read article or submit your manuscript for publishing.
- 1 July 2012
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 6, 1045-9
Open AccessThe effect of phacoemulsification on late bleb failure or intraocular pressure in patients with glaucoma: a systematic review
Peer reviewed article authored by (Peponis VG, Chalkiadakis SE, Katzakis MC, Parikakis EA). Read article or submit your manuscript for publishing.
- 1 July 2012
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (7) , 1130-1133
Piggybacking technique for vitreous protection during opacified intraocular lens exchange in eyes with an open posterior capsule
We describe a surgical technique for the safe exchange of opacified 1-piece IOLs in eyes that have had a neodymium:YAG laser posterior capsulotomy. Initially, the opacified IOL is freed from the capsule adhesions using a dispersive ophthalmic viscosurgical device, which is also injected beneath the opacified IOL to protect the vitreous interface. The IOL is then brought into the anterior chamber. A new 3-piece clear IOL is injected before the opacified IOL is removed and is placed behind the opacified IOL, preventing the vitreous from prolapsing. The pupil is constricted pharmacologically, and the opacified IOL is removed through a standard 2.75 mm corneal incision using the hinge technique. No author has a financial or proprietary interest in any material or method mentioned.
- 1 July 2012
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (7) , 1130-1133
Piggybacking technique for vitreous protection during opacified intraocular lens exchange in eyes with an open posterior capsule
We describe a surgical technique for the safe exchange of opacified 1-piece IOLs in eyes that have had a neodymium:YAG laser posterior capsulotomy. Initially, the opacified IOL is freed from the capsule adhesions using a dispersive ophthalmic viscosurgical device, which is also injected beneath the opacified IOL to protect the vitreous interface. The IOL is then brought into the anterior chamber. A new 3-piece clear IOL is injected before the opacified IOL is removed and is placed behind the opacified IOL, preventing the vitreous from prolapsing. The pupil is constricted pharmacologically, and the opacified IOL is removed through a standard 2.75 mm corneal incision using the hinge technique. No author has a financial or proprietary interest in any material or method mentioned.
- 1 April 2011
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 37 (4) , 778-780
Bilateral central serous retinopathy following laser in situ keratomileusis for myopia
We describe the case of a 54-year-old white man who experienced bilateral central serous chorioretinopathy following laser in situ keratomileusis for myopia. Postoperatively, the uncorrected visual acuity was 20/20 in both eyes. One month later, the patient reported a decrease of vision in both eyes. Dilated fundus examination, fluorescein and indocyanine green angiography, and optical coherence tomography showed bilateral central serous chorioretinopathy. Photodynamic therapy was performed twice, and visual acuity improved. No author has a financial or proprietary interest in any material or method mentioned.
- 1 April 2011
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 37 (4) , 778-780
Bilateral central serous retinopathy following laser in situ keratomileusis for myopia
We describe the case of a 54-year-old white man who experienced bilateral central serous chorioretinopathy following laser in situ keratomileusis for myopia. Postoperatively, the uncorrected visual acuity was 20/20 in both eyes. One month later, the patient reported a decrease of vision in both eyes. Dilated fundus examination, fluorescein and indocyanine green angiography, and optical coherence tomography showed bilateral central serous chorioretinopathy. Photodynamic therapy was performed twice, and visual acuity improved. No author has a financial or proprietary interest in any material or method mentioned.
- Open Access
- 5 March 2011
- Published by S. Karger AG in Case Reports in Ophthalmology
- Vol. 2 (1) , 95-98
Chronic Postoperative Endophthalmitis Caused by Actinomyces meyeri
We report a female patient who developed chronic endophthalmitis after an uneventful cataract surgery. Cultures of aqueous humor and a vitreous sample showed positivity for Actinomyces meyeri. Intense anterior segment inflammation and a less evident impairment of the patient’s posterior segment led us to treat her vigorously with pars plana vitrectomy combined with intraocular and topical antibiotics. The patient achieved a good recovery of vision without the need to remove the intraocular lens and to add systemic drugs. To the best of our knowledge, this is the first reported case of an intraocular infection caused by A. meyeri after small-incision clear corneal phacoemulsification.
- 5 March 2011
- Published by S. Karger AG in Case Reports in Ophthalmology
- Vol. 2 (1) , 95-98
Open AccessChronic Postoperative Endophthalmitis Caused by Actinomyces meyeri
We report a female patient who developed chronic endophthalmitis after an uneventful cataract surgery. Cultures of aqueous humor and a vitreous sample showed positivity for Actinomyces meyeri. Intense anterior segment inflammation and a less evident impairment of the patient’s posterior segment led us to treat her vigorously with pars plana vitrectomy combined with intraocular and topical antibiotics. The patient achieved a good recovery of vision without the need to remove the intraocular lens and to add systemic drugs. To the best of our knowledge, this is the first reported case of an intraocular infection caused by A. meyeri after small-incision clear corneal phacoemulsification.
- Open Access
- 1 November 2010
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 4, 1267-1269
Axial eye length measurements pre- and post- laser-assisted in situ keratomileusis using the IOL Master: a pilot study
Purpose: A preliminary study in order to test the accuracy of the IOL Master in detecting axial eye length changes after laser-assisted in situ keratomileusis and to correlate the findings with the theoretical ablation depth. Methods: Pre- and postoperative axial eye length measurements were performed in 10 consecutive eyes that underwent laser-assisted in situ keratomileusis with the Alcon Ladar Vision excimer laser to treat myopic refractive errors ranging from -2.50 to -8.00 diopters of spherical equivalent (mean: -5.23 ± 1.30 D). Results: The preoperative axial eye length measurements ranged from 24.53 mm to 27.78 mm (mean: 25.80 ± 1.01 mm) and from 24.57 mm to 27.57 mm (mean: 25.68 ± 0.93 mm) 1 month after the operation. Preoperative and 1-month postoperative data showed a statistically significant difference (P <0.05). Conclusions: The IOL Master showed a decrease in the axial eye length measurements that was bigger than the theoretical ablation depth and did not correlate well with it. Such data need to be confirmed by a larger cohort of patients.
- 1 November 2010
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 4, 1267-1269
Open AccessAxial eye length measurements pre- and post- laser-assisted in situ keratomileusis using the IOL Master: a pilot study
Purpose: A preliminary study in order to test the accuracy of the IOL Master in detecting axial eye length changes after laser-assisted in situ keratomileusis and to correlate the findings with the theoretical ablation depth. Methods: Pre- and postoperative axial eye length measurements were performed in 10 consecutive eyes that underwent laser-assisted in situ keratomileusis with the Alcon Ladar Vision excimer laser to treat myopic refractive errors ranging from -2.50 to -8.00 diopters of spherical equivalent (mean: -5.23 ± 1.30 D). Results: The preoperative axial eye length measurements ranged from 24.53 mm to 27.78 mm (mean: 25.80 ± 1.01 mm) and from 24.57 mm to 27.57 mm (mean: 25.68 ± 0.93 mm) 1 month after the operation. Preoperative and 1-month postoperative data showed a statistically significant difference (P <0.05). Conclusions: The IOL Master showed a decrease in the axial eye length measurements that was bigger than the theoretical ablation depth and did not correlate well with it. Such data need to be confirmed by a larger cohort of patients.
- Open Access
- 1 July 2010
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 4, 865-869
The controversy over the association between statins use and progression of age-related macular degeneration: a mini review
Objective: Age-related macular degeneration (AMD) is the leading cause of blindness in ¬western societies. Statins comprise a class of pharmacological agents that reduce plasma cholesterol levels, and have been shown to prevent progression of atherosclerosis and reduce cardiovascular mortality. The relationship between these medications and AMD has been evaluated in several recent studies. Herein, we examine the current evidence for an association between statin use and risk of AMD. Methods: Literature database search (Medline, Scopus, and Science Citation Index Expanded) for articles published up to March 2010, using particular search terms. Results: From the current evidence available, it is not safe to conclude upon the assumption of a protective effect of statins against age-related maculopathy and AMD. Conclusion: There is a need for large scale prospective studies with a long follow-up period and accurate assessment of AMD to further explore this matter.
- 1 July 2010
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 4, 865-869
Open AccessThe controversy over the association between statins use and progression of age-related macular degeneration: a mini review
Objective: Age-related macular degeneration (AMD) is the leading cause of blindness in ¬western societies. Statins comprise a class of pharmacological agents that reduce plasma cholesterol levels, and have been shown to prevent progression of atherosclerosis and reduce cardiovascular mortality. The relationship between these medications and AMD has been evaluated in several recent studies. Herein, we examine the current evidence for an association between statin use and risk of AMD. Methods: Literature database search (Medline, Scopus, and Science Citation Index Expanded) for articles published up to March 2010, using particular search terms. Results: From the current evidence available, it is not safe to conclude upon the assumption of a protective effect of statins against age-related maculopathy and AMD. Conclusion: There is a need for large scale prospective studies with a long follow-up period and accurate assessment of AMD to further explore this matter.
- 25 June 2010
- Published by SAGE Publications in Lupus
- Vol. 19 (8) , 997-1001
Chemosis as a presenting symptom of systemic lupus erythematosus
We present a case of chemosis (conjunctival edema) as an early manifestation of severe systemic lupus erythematosus affecting multiple organs, including the central nervous system and the kidneys.
- 25 June 2010
- Published by SAGE Publications in Lupus
- Vol. 19 (8) , 997-1001
Chemosis as a presenting symptom of systemic lupus erythematosus
We present a case of chemosis (conjunctival edema) as an early manifestation of severe systemic lupus erythematosus affecting multiple organs, including the central nervous system and the kidneys.
- 9 February 2010
- Published by SAGE Publications in Lupus
- Vol. 19 (6) , 675-682
Review: Ocular side effects of anti-rheumatic medications: what a rheumatologist should know
Nearly every drug may cause changes to ocular tissues through a variety of mechanisms. Medication overdoses, drug—drug interactions but also chronic administration of medications at the recommended doses may lead to ocular toxicity. The ocular side effects, screening for eye toxicity and treatment guidelines for anti-inflammatory and immunosuppressive drugs commonly used by rheumatologists are reviewed herein.
- 9 February 2010
- Published by SAGE Publications in Lupus
- Vol. 19 (6) , 675-682
Review: Ocular side effects of anti-rheumatic medications: what a rheumatologist should know
Nearly every drug may cause changes to ocular tissues through a variety of mechanisms. Medication overdoses, drug—drug interactions but also chronic administration of medications at the recommended doses may lead to ocular toxicity. The ocular side effects, screening for eye toxicity and treatment guidelines for anti-inflammatory and immunosuppressive drugs commonly used by rheumatologists are reviewed herein.