SHSimo Huotari

Simo Huotari

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Simo Huotari has a total of 699 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Super-oxidized porous carbons for lanthanide sorption

    by Bartosz GurzęDa, Julia Junttila, Lucia Amidani, Damien Prieur, Christoph J. Sahle, Kari Ruotsalainen, Marius Enachescu, Simo Huotari, Sergei M. Butorin, Nicolas Boulanger, et al.

    Super-oxidized porous carbon (SOPC) synthesized starting from spruce cones is demonstrated as an efficient sorbent for two lanthanide elements (Ce and Yb) from their nitrate solutions.

  • Open Access

    X-ray parametric down-conversion reveals EUV-polariton

    by Dietrich Krebs, Fridtjof Kerker, Xenia Brockmüller, Christoph J. Sahle, Blanka Detlefs, Simo Huotari, Nina Rohringer, Christina Bömer

    Spontaneous parametric down-conversion (PDC) of photons is a gateway into the quantum realm – thoroughly studied in nonlinear optics and ubiquitously used to generate non-classical states of light. Extending PDC from the visible regime towards shorter wavelengths further enables microscopic resolution of electronic structure and quantum-enhanced X-ray detection, but remained challenging due to the process’ inherently low conversion rate. Here, we resolve the full signal cone of non-degenerate down-conversion at X-ray wavelengths and identify imprints of a polariton in the extreme ultraviolet (EUV) regime. We confirm our finding of the EUV-polariton with theoretical simulations and establish that our approach directly images the characteristic anti-crossing of polaritonic dispersion branches. This insight could open a pathway to explore strong-coupling phenomena of EUV-light-matter interaction.


  • Open Access

    Multicomponent dynamics in amorphous ice studied using X-ray photon correlation spectroscopy at elevated pressure and cryogenic temperatures

    by Aigerim Karina, Hailong Li, Tobias Eklund, Marjorie Ladd-Parada, Bernhard Massani, Mariia Filianina, Neha Kondedan, Andreas Rydh, Klara Holl, Ryan Trevorah, et al.

    Knowing the pressure dependence of glass forming liquids is important in various contexts. Here, we study the case of supercooled water, which has at least two different amorphous states with different densities. The pressure dependencies of the two glass transitions are predicted to show opposite behaviour, crossing in the P-T plane at elevated pressure. The experimental identification of the glass transition at elevated pressure and cryo-conditions is technically difficult. Moreover, in the case of amorphous ices, the glass transition is interrupted by crystallization, which makes it even more challenging. We show the feasibility of performing X-ray photon correlation spectroscopy experiments at elevated pressure using a diamond anvil cell at cryogenic temperatures. We observe two dynamic components when approaching the glass transition temperature. For high-density amorphous ice at a pressure of around (0.08 ± 0.02) GPa we determine the glass transition to be at higher temperatures compared to ambient conditions.


  • Top Cited Papers
    Open Access

    The Heisenberg-RIXS instrument at the European XFEL

    by Justine Schlappa, Giacomo Ghiringhelli, Benjamin E. Van Kuiken, Martin Teichmann, Piter S. Miedema, Jan Torben Delitz, Natalia Gerasimova, Serguei Molodtsov, Luigi Adriano, Bernard Baranasic, et al.

    Resonant inelastic X-ray scattering (RIXS) is an ideal X-ray spectroscopy method to push the combination of energy and time resolutions to the Fourier transform ultimate limit, because it is unaffected by the core-hole lifetime energy broadening. Also, in pump–probe experiments the interaction time is made very short by the same core-hole lifetime. RIXS is very photon hungry so it takes great advantage from high-repetition-rate pulsed X-ray sources like the European XFEL. The Heisenberg RIXS instrument is designed for RIXS experiments in the soft X-ray range with energy resolution approaching the Fourier and the Heisenberg limits. It is based on a spherical grating with variable line spacing and a position-sensitive 2D detector. Initially, two gratings were installed to adequately cover the whole photon energy range. With optimized spot size on the sample and small pixel detector the energy resolution can be better than 40 meV (90 meV) at any photon energy below 1000 eV with the high-resolution (high-transmission) grating. At the SCS instrument of the European XFEL the spectrometer can be easily positioned thanks to air pads on a high-quality floor, allowing the scattering angle to be continuously adjusted over the 65–145° range. It can be coupled to two different sample interaction chambers, one for liquid jets and one for solids, each state-of-the-art equipped and compatible for optical laser pumping in collinear geometry. The measured performances, in terms of energy resolution and count rate on the detector, closely match design expectations. The Heisenberg RIXS instrument has been open to public users since the summer of 2022.


  • Open Access

    Comparison of Low-Brilliance X-Ray Phase-Contrast Tomography and Contrast-Enhanced Attenuation-Contrast Micro–Computed Tomography of Rat Kidneys

    by Henrik Mäkinen, Satu Kuure, Jukka Jernvall, Vilma Väänänen, Simo Huotari, Heikki Suhonen

    Key Points: X-ray phase-contrast imaging provides superior contrast to attenuation-based X-ray imaging with soft-tissue samples. X-ray phase-contrast tomography is a viable alternative to contrast-enhanced attenuation-based micro–computed tomography in laboratory-based kidney imaging. X-ray phase-contrast imaging could be a suitable method for screening and characterization of rodent renal pathologies. Background: Structural analysis of soft biological tissues is conventionally conducted with destructive 2D histology. Three-dimensional information can be accessed with noninvasive imaging methods, such as X-ray micro–computed tomography (micro-CT). Although attenuation-based X-ray imaging alone does not provide reasonable contrast with soft-tissue samples, the combination with contrast-enhancing staining has proven effective. The staining process, however, comes with several disadvantages, such as tissue alterations and laboriousness. A novel X-ray imaging method known as phase-contrast imaging has emerged as an interesting alternative to contrast-enhanced micro-CT. Our objective was to show the feasibility of laboratory-based phase-contrast imaging in (murine) kidney research. Methods: X-ray phase-contrast images of male rat kidneys were acquired with a Talbot-Lau interferometer. Moreover, attenuation-based X-ray images of the same unstained kidneys were acquired with a regular micro-CT device. Afterward, the kidneys were stained with phosphotungstic acid for several months. Attenuation-based micro-CT images were reacquired after the staining. Contrast-to-noise ratio was evaluated for all three cases. Results: For unstained kidneys, the phase-contrast images show significantly improved contrast in comparison with attenuation images. Several key features, including the cortex, inner and outer medulla, papilla, as well as the main blood vessels, can be identified. While the contrast in attenuation images improves significantly after staining, the benefit is deteriorated by sample areas that the contrast agent did not reach properly, even after 206 days. Conclusions: Our results indicate that X-ray phase-contrast imaging is a viable option for kidney imaging in a laboratory setting, providing comparable or better results than contrast-enhanced micro-CT. With imaging setups optimized for image resolution and faster imaging times, the advantages of phase-contrast imaging will be even greater.


  • Open Access

    Ambient pressure x-ray photoelectron spectroscopy study on the initial atomic layer deposition process of platinum

    by E. Kokkonen, H.-E. Nieminen, F. Rehman, V. Miikkulainen, M. Putkonen, M. Ritala, S. Huotari, J. Schnadt, S. Urpelainen

    The initial adsorption of MeCpPtMe3 is investigated using synchrotron-based ambient pressure x-ray photoelectron spectroscopy (XPS). The experiments are done on a native oxide-covered Si substrate. In addition, a reaction with O2 and the created Pt surface was investigated. Inspiration for the reaction studies was found from atomic layer deposition of metallic Pt, process that uses the same compounds as precursors. With time-resolved XPS, we have been able to observe details of the deposition process and especially see chemical changes on the Pt atoms during the initial deposition of the Pt precursor. The change of the binding energy of the Pt 4f core level appears to occur on a different timescale than the growth of the active surface sites. The very long pulse of the Pt precursor resulted in a metallic surface already from the beginning, which suggest chemical vapor deposition-like reactions occurring between the surface and the precursor molecules in this experiment. Additionally, based on the XPS data measured after the Pt precursor pulse, we can make suggestions for the reaction pathway, which point toward a scenario that leaves carbon from the MeCpPtMe3 precursor on the surface. These carbon species are then efficiently removed by the subsequent coreactant pulse, leaving behind a mostly metallic Pt film.


  • Open Access

    Surface and Grain Boundary Coating for Stabilizing LiNi0.8Mn0.1Co0.1O2 Based Electrodes

    by Zahra Ahaliabadeh, Ville Miikkulainen, Miia Mäntymäki, Seyedabolfazl Mousavihashemi, Lide Yao, Hua Jiang, Simo Huotari, Timo Kankaanpää, Tanja Kallio, Mattia Colalongo

    The widespread use of high‐capacity Ni‐rich layered oxides such as LiNi0.8Mn0.1Co0.1O2 (NMC811), in lithium‐ion batteries is hindered due to practical capacity loss and reduced working voltage during operation. Aging leads to defective NMC811 particles, affecting electrochemical performance. Surface modification offers a promising approach to improve cycle life. Here, we introduce an amorphous lithium titanate (LTO) coating via atomic layer deposition (ALD), not only covering NMC811 surfaces but also penetrating cavities and grain boundaries. As NMC811 electrodes suffer from low structural stability during charge and discharge, We combined electrochemistry, operando X‐ray diffraction (XRD), and dilatometry to understand structural changes and the coating protective effects. XRD reveals significant structural evolution during delithiation for uncoated NMC811. The highly reversible phase change in coated NMC811 highlights enhanced bulk structure stability. The LTO coating retards NMC811 degradation, boosting capacity retention from 86 % to 93 % after 140 cycles. This study underscores the importance of grain boundary engineering for Ni‐rich layered oxide electrode stability and the interplay of chemical and mechanical factors in battery aging.


  • Open Access

    Amorphous carbon modulated-quantum dots NiO for efficient oxygen evolution in anion exchange membrane water electrolyzer

    by Benjin Jin, Qian Wang, Jani Sainio, Viktoriia A. Saveleva, Hua Jiang, Junjie Shi, Basit Ali, Antti-Jussi Kallio, Simo Huotari, Dage Sundholm, et al.


  • Open Access

    Optimization of contrast and dose in x-ray phase-contrast tomography with a Talbot-Lau interferometer

    by Henrik Mäkinen, Heikki Suhonen, Teemu Siiskonen, Christian David, Simo Huotari

    X-ray phase-contrast imaging has become a valuable tool for biomedical research due to its improved contrast abilities over regular attenuation-based imaging. The recently emerged Talbot-Lau interferometer can provide quantitative attenuation, phase-contrast and dark-field image data, even with low-brilliance x-ray tube sources. Thus, it has become a valid option for clinical environments. In this study, we analyze the effects of x-ray tube voltage and total number of images on the contrast-to-noise ratio (CNR) and dose-weighted CNR (CNRD) calculated from tomographic transmission and phase-contrast data of a phantom sample. Constant counting statistics regardless of the voltage was ensured by adjusting the image exposure time for each voltage setting. The results indicate that the x-ray tube voltage has a clear effect on both image contrast and noise. This effect is amplified in the case of phase-contrast images, which is explained by the polychromatic x-ray spectrum and the dependence of interferometer visibility on the spectrum. CNRD is additionally affected by the total imaging time. While submerging the sample into a water container effectively reduces image artefacts and improves the CNR, the additional attenuation of the water must be compensated with a longer exposure time. This reduces dose efficiency. Both the CNR and CNRD are higher in the phase-contrast images compared to transmission images. For transmission images, and phase-contrast images without the water container, CNRD can be increased by using higher tube voltages (in combination with a lower exposure time). For phase-contrast images with the water container, CNRD is increased with lower tube voltages. In general, the CNRD does not strongly depend on the number of tomographic angles or phase steps used.


  • Inner product regularized multi-energy X-ray tomography for material decomposition

    by Salla-Maaria Latva-Äijö, Filippo Zanetti, Ari-Pekka Honkanen, Simo Huotari, Jacek Gondzio, Matti Lassas, Samuli Siltanen

    Multi-energy X-ray tomography is studied for decomposing three materials using three X-ray energies and a classical energy-integrating detector. A regularization term is used, which includes the inner products between the material distribution functions, penalizing any overlap of different materials. An interior point method is used to solve the underlying quadratic optimization problem; a previously developed preconditioner is extended to the case with three materials, while its theoretical properties are analyzed for any number of materials. The strategy is tested on real data of a phantom embedded with Na$ _2 $SeO$ _3 $, Na$ _2 $SeO$ _4 $, and elemental selenium. These selenium-based materials exhibit K-edges suitable for investigating the proposed method. It is found that the two-dimensional distributions of selenium in different oxidation states can be mapped and distinguished from each other with the proposed algorithm. The results have applications in material science, chemistry, biology and medicine.