JBJonathan Bloom

Jonathan Bloom

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jonathan Bloom has a total of 69 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Do Skills Naturally Transfer Between Multiport and Single-Port Robotic Platforms? A Comparative Study in a Simulated Environment

    by Ahmed Ghazi, Nathan Schuler, Patrick Saba, Tyler Holler, Alexis Steinmetz, Kit Yuen, Karen Doersch, Elizabeth Ellis, William Tabayoyong, Jonathan Bloom, et al.

    Introduction and Objective: With introduction of the da Vinci single-port (SP) system, we evaluated which multiport (MP) robotic skills are naturally transferable to the SP platform. Methods: Three groups of urologists: Group 1 (5 inexperienced in MP and SP), Group 2 (5 experienced in MP without SP experience), and Group 3 (2 experienced in both MP and SP) were recruited to complete a validated urethrovesical anastomosis simulation using MP followed by SP robots. Performance was graded using both GEARS and RACE scales. Subjective cognitive load measurements (Surg-TLX and difficulty ratings [/20] of instrument collisions camera and EndoWrist movement) were collected. Results: GEARS and RACE scores for Groups 1 and 3 were maintained on switching from MP to SP (Group 3 scored significantly higher on both systems). Surg-TLX and difficulty scores were also maintained for both groups on switching from MP and SP except for a significant increase in SP camera movement (+7.2, p = 0.03) in Group 1 compared to Group 3 that maintained low scores on both. Group 2 demonstrated significant lower GEARS (−2.9, p = 0.047) and RACE (−5.1, p = 0.011) scores on SP vs MP. On subanalysis, GEARS subscores for force sensitivity and robotic control (−0.7, p = 0.04; −0.9, p = 0.02) and RACE subscores for needle entry, needle driving, and tissue approximation (−0.9, p = 0.01; −1.0, p = 0.02; −1.0, p < 0.01) significantly decreased. GEARS (depth perception, bimanual dexterity, and efficiency) and RACE subscores (needle positioning and suture placement) were maintained. All participants scored significantly lower in knot tying on the SP robot (−1.0, p = 0.03; −1.2, p = 0.02, respectively). Group 2 reported higher Surg-TLX (+13 pts, p = 0.015) and difficulty ratings on SP vs MP (+11.8, p < 0.01; +13.6, p < 0.01; +14 pts, p < 0.01). Conclusions: The partial skill transference across robots raises the question regarding SP-specific training for urologists proficient in MP. Novices maintained difficulty scores and cognitive load across platforms, suggesting that concurrent SP and MP training may be preferred.


  • Open Access

    MRI-guided focal laser ablation of prostate cancer: a prospective single-arm, single-center trial with 3 years of follow-up

    by Sherif Mehralivand, Arvin K George, Anthony N Hoang, Soroush Rais-Bahrami, Ardeshir R Rastinehad, Amir H Lebastchi, Michael Ahdoot, Mohummad Minhaj Siddiqui, Jonathan Bloom, Abhinav Sidana, et al.

    We aimed to assess post-interventional and 36-month follow-up results of a single-center, single-arm, in-bore phase I trial of focal laser ablation (FLA) guided by multiparametric magnetic resonance imaging (mpMRI). FLA procedures were done in-bore MRI using a transperineal approach. Primary endpoints were feasibility and safety expressed as lack of grade 3 complications. Secondary endpoints were changes in international prostate symptom score (IPSS), sexual health inventory for men (SHIM), quality of life (QoL) scores, and serum prostate specific antigen (PSA) levels. Treatment outcomes were assessed by combined mpMRI-ultrasound fusion-guided and extended sextant systematic biopsy after 12, 24, and optionally after 36 months. Fifteen participants were included. Seven patients (46.67%) had Gleason 3+3 and 8 patients (53.33%) had Gleason 3+4 cancer. All patients tolerated the procedure well, and no grade 3/4 complications occurred. All grade 1 and 2 complications were transient and resolved completely. There was no significant change in mean IPSS from baseline (-1, p = 0.460) and QoL (0, p = 0.441) scores following FLA but there was a significant drop in mean SHIM scores (-2, p = 0.010) compared to pretreatment baselines. Mean PSA significantly decreased after FLA (-2.5, p < 0.001). Seven out of 15 patients (46.67%) had residual cancer in, adjacent, or in close proximity to the treatment area (1 × 4+3=7, 1 × 3+4=7, and 5 × 3+3=6). Four out of 15 patients (26.67%) underwent salvage therapy (2 repeat FLA, 2 radical prostatectomy). After 3 years of follow-up we conclude focal laser ablation is safe and feasible without significant complications.


  • Use of multiparametric magnetic resonance imaging and fusion‐guided biopsies to properly select and follow African‐American men on active surveillance

    by Jonathan B. Bloom, Amir H. Lebastchi, Samuel A. Gold, Graham R. Hale, Thomas Sanford, Sherif Mehralivand, Michael Ahdoot, Kareem N. Rayn, Marcin Czarniecki, Clayton Smith, et al.

    Objectives: To determine the rate of Gleason Grade Group ( GGG ) upgrading in African‐American ( AA ) men with a prior diagnosis of low‐grade prostate cancer ( GGG 1 or GGG 2) on 12‐core systematic biopsy ( SB ) after multiparametric magnetic resonance imaging (mp MRI ) and fusion biopsy ( FB ); and whether AA men who continued active surveillance ( AS ) after mp MRI and FB fared differently than a predominantly Caucasian (non‐ AA ) population. Patients and methods: A database of men who had undergone mp MRI and FB was queried to determine rates of upgrading by FB amongst men deemed to be AS candidates based on SB prior to referral. After FB , Kaplan–Meier curves were generated for AA men and non‐ AA men who then elected AS . The time to GGG upgrading and time continuing AS were compared using the log‐rank test. Results: AA men referred with GGG 1 disease on previous SB were upgraded to GGG ≥3 by FB more often than non‐ AA men, 22.2% vs 12.7% ( P = 0.01). A total of 32 AA men and 258 non‐ AA men then continued AS, with a median (interquartile range) follow‐up of 39.19 (24.24–56.41) months. The median time to progression was 59.7 and 60.5 months, respectively ( P = 0.26). The median time continuing AS was 61.9 months and not reached, respectively ( P = 0.80). Conclusions: AA men were more likely to be upgraded from GGG 1 on SB to GGG ≥3 on initial FB ; however, AA and non‐ AA men on AS subsequently progressed at similar rates following mp MRI and FB . A greater tendency for SB to underestimate tumour grade in AA men may explain prior studies that have shown AA men to be at higher risk of progression during AS .


  • A multiparametric magnetic resonance imaging-based virtual reality surgical navigation tool for robotic-assisted radical prostatectomy

    by Sherif Mehralivand, Vladimir Valera Romero, Samuel Gold, Peter A. Pinto, Jonathan Bloom, Graham Hale, Peter L. Choyke, Barış Türkbey, Thomas Sanford, Chandra Kambhamettu, et al.

    Objective: Increased computational power and improved visualization hardware have generated more opportunities for virtual reality (VR) applications in healthcare. In this study, we test the feasibility of a VR-assisted surgical navigation system for robotic-assisted radical prostatectomy. Material and methods: The prostate, all magnetic resonance imaging (MRI) visible tumors, and important anatomic structures like the neurovascular bundles, seminal vesicles, bladder, and rectum were contoured on a multiparametric MRI using an in-house segmentation software. Three-dimensional (3-D) VR models were rendered and evaluated in a side room of the operating room. While interacting with the VR platform, a real-time stereo video capture of the in situ prostate was obtained to render a second 3-D model. The MRI-based model was then overlaid on the real-time model by using an automated alignment algorithm. Results: Ten patients were included in this study. All MRI-based VR models were examined by surgeons immediately prior to surgery and at important steps where visualization of the tumors and their proximity to surrounding anatomic structures were critical. This was mainly during the preparation of the prostatic pedicles, neurovascular plexus, the apex, and bladder neck. All participants found the system useful, especially for tumors with locally aggressive growth patterns. For small and centrally located tumors, the system was not considered beneficial due to lack of integration into the robotic console. A fully integrated system with real-time overlays within the robotic stereo viewer was found to be the ideal scenario. Conclusion: We deployed a preliminary VR-assisted surgical navigation tool for robotic-assisted radical prostatectomies. Cite this article as: Mehralivand S, Kolagunda A, Hammerich K, Sabarwal V, Harmon S, Sanford T, et al. A multiparametric magnetic resonance imaging-based virtual reality surgical navigation tool for robotic-assisted radical prostatectomy. Turk J Urol 2019; 45(5): 357-65.


  • Incidental bladder cancers found on multiparametric MRI of the prostate gland: a single center experience

    by Kareem N. Rayn, Graham R. Hale, Jonathan B. Bloom, Samuel A. Gold, Filipe L.F. Carvalho, Sherif Mehralivand, Marcin Czarniecki, Bradford J. Wood, Maria J. Merino, Peter Choyke, et al.

    Diagnostic and Interventional Radiology


  • Device-Related Adverse Events During Percutaneous Nephrolithotomy: Review of the Manufacturer and User Facility Device Experience Database

    by Neel H. Patel, Ariel A. Schulman, Jonathan B. Bloom, Nikil Uppaluri, John L. Phillips, Sensuke Konno, Muhammad Choudhury, Majid Eshghi

    Introduction and Objectives: Percutaneous nephrolithotomy (PCNL) is an established technique for removal of large stones from the upper urinary tract. It is a complex multistep procedure requiring several classes of instruments that are subject to operator misuse and device malfunction. We report device-related adverse events during PCNL from the Manufacturer and User Facility Device Experience (MAUDE) database using a recently developed standardized classification system. Materials and Methods: The MAUDE database was queried for “percutaneous nephrolithotomy” from 2006 to 2016. The circumstances and patient complications associated with classes of devices used during PCNL were identified. We then utilized a novel MAUDE classification system to categorize clinical events. Logistic regression analysis was performed to identify associations between device classes and severe adverse events. Results: A total of 218 device-related events were reported. The most common classes included: lithotripter 53 (24.3%), wires 43 (19.7%), balloon dilators 30 (13.8%), and occlusion balloons 28 (12.8%). Reported patient complications included need for a second procedure 12 (28.6%), bleeding 8 (19.0%), retained fragments 7 (16.7%), prolonged procedure 4 (9.5%), ureteral injury 2 (4.8%), and conversion to an open procedure 3 (7.1%). Using a MAUDE classification system, 176 complications (81%) were Level I (mild/none), 26 (12%) were Level II (moderate), 15 (7%) were Level III (severe), and 1 (0.5%) was Level IV (life threatening). On univariate analysis, balloon dilators had the highest risk of Level II–IV complications compared with the other device classes [odds ratio: 4.33, confidence interval: 1.978, 9.493, p < 0.001]. The device was evaluated by the manufacturer in 93 (42.7%) cases, with 54.8% of reviewed cases listing the source of malfunction as misuse by the operator. Conclusions: PCNL is subject to a wide range of device-related adverse events. A MAUDE classification system is useful for standardized, clinically-relevant reporting of events. Our findings highlight the importance of proper surgeon training with devices to maximize efficiency and decrease harm.


  • Open Access

    Ischemic stroke produces long‐term fiber track myelin loss that contributes to persistent sensory, motor and cognitive behavioral deficits

    by Carrie Poon, Jin Zhou, Jian Zhuang, Jie Li, Jonathan Bloom, Evelyn Ooi, Daniel Lax, Daniel Rosenbaum, Frank Barone

    Objective: To investigate and characterize long‐term post‐ischemic stroke hemispheric and cellular loss, and fiber track injury. Also to investigate the sensory, motor and cognitive performance deficits for use in future restoration research. Methods: Middle cerebral artery occlusion (stroke) or sham surgery was performed in male Sprague‐Dawley rats. Neurobehavioral (sensory, motor, beam balance, reflexes, hindlimb and forelimb function, and cylinder placement tests) and cognitive (complex active place avoidance; APA and simple passive avoidance retention; PA tests) performance was measured. Electroretinograms (ERG), ischemic hemisphere, hippocampus neuronal loss and fiber track injury were measured. Results: Stroke surgery produced significant (p<0.01) sustained (10 weeks) deficits in motor, sensory, beam balance and hindlimb performance. Stroke produced large and prolonged cognitive performance deficits in APA learning (p<0.01) but smaller effects on PA retention. No effects on ERG or hippocampus neurons occurred but fiber tracts in the external capsule and striatum exhibited significant (p<0.01) damage. Conclusion: Specific, long‐term deficits in neurobehavioral tests were verified as endpoints for stroke restorative therapeutic research. Fiber track injury contributes to these deficits and is especially important for the complex cognitive control required for APA learning.