Eva Weatherall
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Eva Weatherall has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Geoff R. Willmott
3 shared publications- Geoff. R. Willmott
The MacDiarmid Institute for Advanced Materials and Nanotechnology, Victoria University of Wellington, Wellington 6140, New Zealand
3 shared publications Michelle Dickinson
2 shared publications- Thomas Loho
Department of Chemical and Materials Engineering, University of Auckland, Auckland 1142, New Zealand
2 shared publications Aaron H. Colby
1 shared publication- Aaron H. Colby
Department of Biomedical Engineering, Boston University
1 shared publication
Latest Publications
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Nanotechnology
- Vol. 14 (1/2/3/4/5/) , 446
Tunable resistive pulse sensing and nanoindentation of pH-responsive expansile nanoparticles
Experimental studies of pH-responsive expansile nanoparticles (eNPs) have been carried out using tunable resistive pulse sensing (TRPS) and nanoindentation. The eNPs are initially ∼200 nm in diameter, but increase in size owing to a compositional change resulting from cleavage of pH-labile protecting groups on the polymer backbone at low pH. TRPS detected expected changes in the size of eNPs, most clearly through an increase in the size distribution close to ∼1 μm diameter with time after exposure to pH 5.0 electrolyte. Heavily cross-linked nanoparticles and eNPs kept at neutral pH did not produce such pronounced changes. Nanoindentation results demonstrate that for accurate measurement of eNP mechanical properties, particles must be precisely located and securely fixed to the substrate. Moreover, the expanded eNPs may be too weak to respond to conventional nanoindentation. Nanoscale physical characterisation of soft matter is of burgeoning importance in medical and biotechnological research and applications.
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Nanotechnology
- Vol. 14 (1/2/3/4/5/) , 446
Tunable resistive pulse sensing and nanoindentation of pH-responsive expansile nanoparticles
Experimental studies of pH-responsive expansile nanoparticles (eNPs) have been carried out using tunable resistive pulse sensing (TRPS) and nanoindentation. The eNPs are initially ∼200 nm in diameter, but increase in size owing to a compositional change resulting from cleavage of pH-labile protecting groups on the polymer backbone at low pH. TRPS detected expected changes in the size of eNPs, most clearly through an increase in the size distribution close to ∼1 μm diameter with time after exposure to pH 5.0 electrolyte. Heavily cross-linked nanoparticles and eNPs kept at neutral pH did not produce such pronounced changes. Nanoindentation results demonstrate that for accurate measurement of eNP mechanical properties, particles must be precisely located and securely fixed to the substrate. Moreover, the expanded eNPs may be too weak to respond to conventional nanoindentation. Nanoscale physical characterisation of soft matter is of burgeoning importance in medical and biotechnological research and applications.
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Nanotechnology
- Vol. 14 (1) , 1
Tunable resistive pulse sensing and nanoindentation of pH-responsive expansile nanoparticles
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Nanotechnology
- Vol. 14 (1) , 1
Tunable resistive pulse sensing and nanoindentation of pH-responsive expansile nanoparticles
- 10 August 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (17) , 8648-8656
Pulse Size Distributions in Tunable Resistive Pulse Sensing
The use of resistive pulse sensors for submicron particle size measurements relies on a clear understanding of pulse size distributions. Here, broadening of such distributions has been studied and explained using conical pores and nominally monodisperse polystyrene particles 200–800 nm in diameter. The use of tunable resistive pulse sensing (TRPS) enabled continuous in situ control of the pore size during experiments. Pulse size distributions became broader when the pore size was increased and featured two distinct peaks. Similar distributions were generated using finite element simulations, which suggested that relatively large pulses are produced by particles with trajectories passing near to the edge of the pore. Other experiments determined that pulse size distributions are independent of applied voltage but broaden with increasing pressure applied across the membrane. The applied pressure could also be reversed in response to a pulse, which enabled repeated measurement of individual particles moving back and forth through the pore. Hydrodynamic and electrophoretic focusing each appear to affect particle trajectories under certain conditions.
- 10 August 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (17) , 8648-8656
Pulse Size Distributions in Tunable Resistive Pulse Sensing
The use of resistive pulse sensors for submicron particle size measurements relies on a clear understanding of pulse size distributions. Here, broadening of such distributions has been studied and explained using conical pores and nominally monodisperse polystyrene particles 200–800 nm in diameter. The use of tunable resistive pulse sensing (TRPS) enabled continuous in situ control of the pore size during experiments. Pulse size distributions became broader when the pore size was increased and featured two distinct peaks. Similar distributions were generated using finite element simulations, which suggested that relatively large pulses are produced by particles with trajectories passing near to the edge of the pore. Other experiments determined that pulse size distributions are independent of applied voltage but broaden with increasing pressure applied across the membrane. The applied pressure could also be reversed in response to a pulse, which enabled repeated measurement of individual particles moving back and forth through the pore. Hydrodynamic and electrophoretic focusing each appear to affect particle trajectories under certain conditions.
- 14 April 2015
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 119 (16) , 5328-5335
Conductive and Biphasic Pulses in Tunable Resistive Pulse Sensing
This experimental study concerns the occurrence of biphasic pulses generated during tunable resistive pulse sensing (TRPS) of 200 nm carboxylate polystyrene spheres. In TRPS, a short-lived pulse in ionic current is observed when an individual colloid passes through a pore which separates two fluid reservoirs. The pulse is conventionally resistive, but conductive pulses are observed under certain experimental conditions, as well as biphasic pulses which include both resistive and conductive components. The experimental variables investigated here include the concentration of the phosphate-buffered saline electrolyte, particle charge, pore size, applied voltage, and the direction of particle motion. The onset upper electrolyte concentration for biphasic pulses in TRPS is ∼50 mM, and the ordering of biphasic pulse components can be interpreted using ionic concentration polarization if the conductive component is generated when the particle is in the ion depletion region. Besides providing fundamental understanding, the results are important for the TRPS technique, which is becoming widely used for particle-by-particle measurements of submicron colloids.
- 14 April 2015
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 119 (16) , 5328-5335
Conductive and Biphasic Pulses in Tunable Resistive Pulse Sensing
This experimental study concerns the occurrence of biphasic pulses generated during tunable resistive pulse sensing (TRPS) of 200 nm carboxylate polystyrene spheres. In TRPS, a short-lived pulse in ionic current is observed when an individual colloid passes through a pore which separates two fluid reservoirs. The pulse is conventionally resistive, but conductive pulses are observed under certain experimental conditions, as well as biphasic pulses which include both resistive and conductive components. The experimental variables investigated here include the concentration of the phosphate-buffered saline electrolyte, particle charge, pore size, applied voltage, and the direction of particle motion. The onset upper electrolyte concentration for biphasic pulses in TRPS is ∼50 mM, and the ordering of biphasic pulse components can be interpreted using ionic concentration polarization if the conductive component is generated when the particle is in the ion depletion region. Besides providing fundamental understanding, the results are important for the TRPS technique, which is becoming widely used for particle-by-particle measurements of submicron colloids.
- 18 February 2015
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 140 (10) , 3318-3334
Applications of tunable resistive pulse sensing
This Review focusses on the recent surge in applied research using tunable resistive pulse sensing, a technique used to analyse submicron colloids in aqueous solutions on a particle-by-particle basis.
- 18 February 2015
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 140 (10) , 3318-3334
Applications of tunable resistive pulse sensing
This Review focusses on the recent surge in applied research using tunable resistive pulse sensing, a technique used to analyse submicron colloids in aqueous solutions on a particle-by-particle basis.
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21568065,p. 874-878
Individual nanoparticle zeta potential measurements using tunable resistive pulse sensing
Tunable resistive pulse sensing has been used to measure the zeta potential of two sets of 200 nm diameter polystyrene nanoparticles in 0.1 M KCl electrolyte. Data were analysed using two methods, both of which yield particle-by-particle zeta potential values based on electrophoretic mobility. Five pore specimens were used, and in most cases data clearly indicate that one particle set had a higher (less negative) zeta potential than the calibrated zeta potential of the other particle set (-35 mV). Three tungsten needles were used to fabricate the pores, and comparable results were obtained for pores made by the same needle. Measurements were carried out with varying potential applied, and a reliable working range of 0.3 to 0.6 V was observed. Measurement of zeta potentials on individual nanoparticles is important for colloidal applications such as foods, cosmetics, mineral extraction and biomedical technologies.
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21568065,p. 874-878
Individual nanoparticle zeta potential measurements using tunable resistive pulse sensing
Tunable resistive pulse sensing has been used to measure the zeta potential of two sets of 200 nm diameter polystyrene nanoparticles in 0.1 M KCl electrolyte. Data were analysed using two methods, both of which yield particle-by-particle zeta potential values based on electrophoretic mobility. Five pore specimens were used, and in most cases data clearly indicate that one particle set had a higher (less negative) zeta potential than the calibrated zeta potential of the other particle set (-35 mV). Three tungsten needles were used to fabricate the pores, and comparable results were obtained for pores made by the same needle. Measurements were carried out with varying potential applied, and a reliable working range of 0.3 to 0.6 V was observed. Measurement of zeta potentials on individual nanoparticles is important for colloidal applications such as foods, cosmetics, mineral extraction and biomedical technologies.