Matthew J. Nyflot
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Matthew J. Nyflot has a total of 107 co-authors. Here are the top co-authors by number of shared publications:
- Matthew B. Spraker
Washington University in St. Louis
4 shared publications - Stephen R. Bowen
University of Washington
4 shared publications Eric C. Ford
Department of Radiation Oncology, University of Washington, Seattle, WA, USA
3 shared publications- Jan Caspar Peeken
Department of Radiation Oncology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
3 shared publications - Paul Eugene Kinahan
Department of Radiology University of Washington Seattle Washington USA
3 shared publications - Stephanie K. Schaub
Department of Radiation Oncology, University of Washington School of Medicine, Seattle, WA, United States
3 shared publications
Latest Publications
- 31 May 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 209, 110963
Functional liver imaging and dosimetry for risk stratification in patients with hepatocellular carcinoma undergoing radiotherapy: validation study
- 31 May 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 209, 110963
Functional liver imaging and dosimetry for risk stratification in patients with hepatocellular carcinoma undergoing radiotherapy: validation study
- Top Cited PapersOpen Access
- 3 September 2023
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 96 (1150) , 20230211
Artificial intelligence (AI) and machine learning (ML) in precision oncology: a review on enhancing discoverability through multiomics integration
Multiomics data including imaging radiomics and various types of molecular biomarkers have been increasingly investigated for better diagnosis and therapy in the era of precision oncology. Artificial intelligence (AI) including machine learning (ML) and deep learning (DL) techniques combined with the exponential growth of multiomics data may have great potential to revolutionize cancer subtyping, risk stratification, prognostication, prediction and clinical decision-making. In this article, we first present different categories of multiomics data and their roles in diagnosis and therapy. Second, AI-based data fusion methods and modeling methods as well as different validation schemes are illustrated. Third, the applications and examples of multiomics research in oncology are demonstrated. Finally, the challenges regarding the heterogeneity data set, availability of omics data, and validation of the research are discussed. The transition of multiomics research to real clinics still requires consistent efforts in standardizing omics data collection and analysis, building computational infrastructure for data sharing and storing, developing advanced methods to improve data fusion and interpretability, and ultimately, conducting large-scale prospective clinical trials to fill the gap between study findings and clinical benefits.
- 3 September 2023
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 96 (1150) , 20230211
Top Cited PapersOpen AccessArtificial intelligence (AI) and machine learning (ML) in precision oncology: a review on enhancing discoverability through multiomics integration
Multiomics data including imaging radiomics and various types of molecular biomarkers have been increasingly investigated for better diagnosis and therapy in the era of precision oncology. Artificial intelligence (AI) including machine learning (ML) and deep learning (DL) techniques combined with the exponential growth of multiomics data may have great potential to revolutionize cancer subtyping, risk stratification, prognostication, prediction and clinical decision-making. In this article, we first present different categories of multiomics data and their roles in diagnosis and therapy. Second, AI-based data fusion methods and modeling methods as well as different validation schemes are illustrated. Third, the applications and examples of multiomics research in oncology are demonstrated. Finally, the challenges regarding the heterogeneity data set, availability of omics data, and validation of the research are discussed. The transition of multiomics research to real clinics still requires consistent efforts in standardizing omics data collection and analysis, building computational infrastructure for data sharing and storing, developing advanced methods to improve data fusion and interpretability, and ultimately, conducting large-scale prospective clinical trials to fill the gap between study findings and clinical benefits.
- Top Cited PapersOpen Access
Development and External Validation of Deep-Learning-Based Tumor Grading Models in Soft-Tissue Sarcoma Patients Using MR Imaging
Background: In patients with soft-tissue sarcomas, tumor grading constitutes a decisive factor to determine the best treatment decision. Tumor grading is obtained by pathological work-up after focal biopsies. Deep learning (DL)-based imaging analysis may pose an alternative way to characterize STS tissue. In this work, we sought to non-invasively differentiate tumor grading into low-grade (G1) and high-grade (G2/G3) STS using DL techniques based on MR-imaging. Methods: Contrast-enhanced T1-weighted fat-saturated (T1FSGd) MRI sequences and fat-saturated T2-weighted (T2FS) sequences were collected from two independent retrospective cohorts (training: 148 patients, testing: 158 patients). Tumor grading was determined following the French Federation of Cancer Centers Sarcoma Group in pre-therapeutic biopsies. DL models were developed using transfer learning based on the DenseNet 161 architecture. Results: The T1FSGd and T2FS-based DL models achieved area under the receiver operator characteristic curve (AUC) values of 0.75 and 0.76 on the test cohort, respectively. T1FSGd achieved the best F1-score of all models (0.90). The T2FS-based DL model was able to significantly risk-stratify for overall survival. Attention maps revealed relevant features within the tumor volume and in border regions. Conclusions: MRI-based DL models are capable of predicting tumor grading with good reproducibility in external validation.
Top Cited PapersOpen AccessDevelopment and External Validation of Deep-Learning-Based Tumor Grading Models in Soft-Tissue Sarcoma Patients Using MR Imaging
Background: In patients with soft-tissue sarcomas, tumor grading constitutes a decisive factor to determine the best treatment decision. Tumor grading is obtained by pathological work-up after focal biopsies. Deep learning (DL)-based imaging analysis may pose an alternative way to characterize STS tissue. In this work, we sought to non-invasively differentiate tumor grading into low-grade (G1) and high-grade (G2/G3) STS using DL techniques based on MR-imaging. Methods: Contrast-enhanced T1-weighted fat-saturated (T1FSGd) MRI sequences and fat-saturated T2-weighted (T2FS) sequences were collected from two independent retrospective cohorts (training: 148 patients, testing: 158 patients). Tumor grading was determined following the French Federation of Cancer Centers Sarcoma Group in pre-therapeutic biopsies. DL models were developed using transfer learning based on the DenseNet 161 architecture. Results: The T1FSGd and T2FS-based DL models achieved area under the receiver operator characteristic curve (AUC) values of 0.75 and 0.76 on the test cohort, respectively. T1FSGd achieved the best F1-score of all models (0.90). The T2FS-based DL model was able to significantly risk-stratify for overall survival. Attention maps revealed relevant features within the tumor volume and in border regions. Conclusions: MRI-based DL models are capable of predicting tumor grading with good reproducibility in external validation.
- Open Access
Prognostic Assessment in High-Grade Soft-Tissue Sarcoma Patients: A Comparison of Semantic Image Analysis and Radiomics
Background: In patients with soft-tissue sarcomas of the extremities, the treatment decision is currently regularly based on tumor grading and size. The imaging-based analysis may pose an alternative way to stratify patients’ risk. In this work, we compared the value of MRI-based radiomics with expert-derived semantic imaging features for the prediction of overall survival (OS). Methods: Fat-saturated T2-weighted sequences (T2FS) and contrast-enhanced T1-weighted fat-saturated (T1FSGd) sequences were collected from two independent retrospective cohorts (training: 108 patients; testing: 71 patients). After preprocessing, 105 radiomic features were extracted. Semantic imaging features were determined by three independent radiologists. Three machine learning techniques (elastic net regression (ENR), least absolute shrinkage and selection operator, and random survival forest) were compared to predict OS. Results: ENR models achieved the best predictive performance. Histologies and clinical staging differed significantly between both cohorts. The semantic prognostic model achieved a predictive performance with a C-index of 0.58 within the test set. This was worse compared to a clinical staging system (C-index: 0.61) and the radiomic models (C-indices: T1FSGd: 0.64, T2FS: 0.63). Both radiomic models achieved significant patient stratification. Conclusions: T2FS and T1FSGd-based radiomic models outperformed semantic imaging features for prognostic assessment.
Open AccessPrognostic Assessment in High-Grade Soft-Tissue Sarcoma Patients: A Comparison of Semantic Image Analysis and Radiomics
Background: In patients with soft-tissue sarcomas of the extremities, the treatment decision is currently regularly based on tumor grading and size. The imaging-based analysis may pose an alternative way to stratify patients’ risk. In this work, we compared the value of MRI-based radiomics with expert-derived semantic imaging features for the prediction of overall survival (OS). Methods: Fat-saturated T2-weighted sequences (T2FS) and contrast-enhanced T1-weighted fat-saturated (T1FSGd) sequences were collected from two independent retrospective cohorts (training: 108 patients; testing: 71 patients). After preprocessing, 105 radiomic features were extracted. Semantic imaging features were determined by three independent radiologists. Three machine learning techniques (elastic net regression (ENR), least absolute shrinkage and selection operator, and random survival forest) were compared to predict OS. Results: ENR models achieved the best predictive performance. Histologies and clinical staging differed significantly between both cohorts. The semantic prognostic model achieved a predictive performance with a C-index of 0.58 within the test set. This was worse compared to a clinical staging system (C-index: 0.61) and the radiomic models (C-indices: T1FSGd: 0.64, T2FS: 0.63). Both radiomic models achieved significant patient stratification. Conclusions: T2FS and T1FSGd-based radiomic models outperformed semantic imaging features for prognostic assessment.
- 13 December 2018
- Published by Wiley in Medical Physics
- Vol. 46 (2) , 456-464
Deep learning for patient‐specific quality assurance: Identifying errors in radiotherapy delivery by radiomic analysis of gamma images with convolutional neural networks
Purpose: Patient‐specific quality assurance (QA) for intensity‐modulated radiation therapy (IMRT) is a ubiquitous clinical procedure, but conventional methods have often been criticized as being insensitive to errors or less effective than other common physics checks. Recently, there has been interest in the application of radiomics, quantitative extraction of image features, to radiotherapy QA. In this work, we investigate a deep learning approach to classify the presence or absence of introduced radiotherapy treatment delivery errors from patient‐specific QA.Methods: Planar dose maps from 186 IMRT beams from 23 IMRT plans were evaluated. Each plan was transferred to a cylindrical phantom CT geometry. Three sets of planar doses were exported from each plan corresponding to (a) the error‐free case, (b) a random multileaf collimator (MLC) error case, and (c) a systematic MLC error case. Each plan was delivered to the electronic portal imaging device (EPID), and planned and measured doses were used to calculate gamma images in an EPID dosimetry software package (for a total of 558 gamma images). Two radiomic approaches were used. In the first, a convolutional neural network with triplet learning was used to extract image features from the gamma images. In the second, a handcrafted approach using texture features was used. The resulting metrics from both approaches were input into four machine learning classifiers (support vector machines, multilayer perceptrons, decision trees, and k‐nearest‐neighbors) in order to determine whether images contained the introduced errors. Two experiments were considered: the two‐class experiment classified images as error‐free or containing any MLC error, and the three‐class experiment classified images as error‐free, containing a random MLC error, or containing a systematic MLC error. Additionally, threshold‐based passing criteria were calculated for comparison.Results: In total, 303 gamma images were used for model training and 255 images were used for model testing. The highest classification accuracy was achieved with the deep learning approach, with a maximum accuracy of 77.3% in the two‐class experiment and 64.3% in the three‐class experiment. The performance of the handcrafted approach with texture features was lower, with a maximum accuracy of 66.3% in the two‐class experiment and 53.7% in the three‐class experiment. Variability between the results of the four machine learning classifiers was lower for the deep learning approach vs the texture feature approach. Both radiomic approaches were superior to threshold‐based passing criteria.Conclusions: Deep learning with convolutional neural networks can be used to classify the presence or absence of introduced radiotherapy treatment delivery errors from patient‐specific gamma images. The performance of the deep learning network was superior to a handcrafted approach with texture features, and both radiomic approaches were better than threshold‐based passing criteria. The results suggest that radiomic QA is a promising direction for clinical radiotherapy.
- 13 December 2018
- Published by Wiley in Medical Physics
- Vol. 46 (2) , 456-464
Deep learning for patient‐specific quality assurance: Identifying errors in radiotherapy delivery by radiomic analysis of gamma images with convolutional neural networks
Purpose: Patient‐specific quality assurance (QA) for intensity‐modulated radiation therapy (IMRT) is a ubiquitous clinical procedure, but conventional methods have often been criticized as being insensitive to errors or less effective than other common physics checks. Recently, there has been interest in the application of radiomics, quantitative extraction of image features, to radiotherapy QA. In this work, we investigate a deep learning approach to classify the presence or absence of introduced radiotherapy treatment delivery errors from patient‐specific QA.Methods: Planar dose maps from 186 IMRT beams from 23 IMRT plans were evaluated. Each plan was transferred to a cylindrical phantom CT geometry. Three sets of planar doses were exported from each plan corresponding to (a) the error‐free case, (b) a random multileaf collimator (MLC) error case, and (c) a systematic MLC error case. Each plan was delivered to the electronic portal imaging device (EPID), and planned and measured doses were used to calculate gamma images in an EPID dosimetry software package (for a total of 558 gamma images). Two radiomic approaches were used. In the first, a convolutional neural network with triplet learning was used to extract image features from the gamma images. In the second, a handcrafted approach using texture features was used. The resulting metrics from both approaches were input into four machine learning classifiers (support vector machines, multilayer perceptrons, decision trees, and k‐nearest‐neighbors) in order to determine whether images contained the introduced errors. Two experiments were considered: the two‐class experiment classified images as error‐free or containing any MLC error, and the three‐class experiment classified images as error‐free, containing a random MLC error, or containing a systematic MLC error. Additionally, threshold‐based passing criteria were calculated for comparison.Results: In total, 303 gamma images were used for model training and 255 images were used for model testing. The highest classification accuracy was achieved with the deep learning approach, with a maximum accuracy of 77.3% in the two‐class experiment and 64.3% in the three‐class experiment. The performance of the handcrafted approach with texture features was lower, with a maximum accuracy of 66.3% in the two‐class experiment and 53.7% in the three‐class experiment. Variability between the results of the four machine learning classifiers was lower for the deep learning approach vs the texture feature approach. Both radiomic approaches were superior to threshold‐based passing criteria.Conclusions: Deep learning with convolutional neural networks can be used to classify the presence or absence of introduced radiotherapy treatment delivery errors from patient‐specific gamma images. The performance of the deep learning network was superior to a handcrafted approach with texture features, and both radiomic approaches were better than threshold‐based passing criteria. The results suggest that radiomic QA is a promising direction for clinical radiotherapy.
- Open Access
- 24 September 2018
- Published by Springer Nature in Radiation Oncology
- Vol. 13 (1) , 186
Radiation oncology resident training in patient safety and quality improvement: a national survey of residency program directors
Physicians and physicists are expected to contribute to patient safety and quality improvement (QI) in Radiation Oncology (RO), but prior studies suggest that training for this may be inadequate. RO and medical physics (MP) program directors (PDs) were surveyed to better understand the current patient safety/QI training in their residency programs. PDs were surveyed via email in January 2017. Survey questions inquired about current training, curriculum elements, and barriers to development and/or improvement of safety and QI training. Eighty-nine RO PDs and 84 MP PDs were surveyed, and 21 RO PDs (28%) and 31 MP PDs (37%) responded. Both RO and MP PDs had favorable opinions of current safety and QI training, and used a range of resources for program development, especially safety and QI publications. Various curriculum elements were reported. Curriculum elements used by RO and MP PDs were similar, except RO were more likely than MP PDs to implement morbidity and mortality (M&M) conference (72% vs. 45%, p < 0.05). RO and MP PDs similarly cited various barriers, but RO PDs were more likely to cite lack of experience than MP PDs (40% vs. 16%, p < 0.05). PDs responded similarly independent of whether they reported using a departmental incident learning system (ILS) or not. PDs view patient safety/QI as an important part of resident education. Most PDs agreed that residents are adequately exposed to patient safety/QI and prepared to meet the patient safety/QI expectations of clinical practice. This conflicts with other independent studies that indicate a majority of residents feel their patient safety/QI training is inadequate and lacks formal exposure to QI tools.
- 24 September 2018
- Published by Springer Nature in Radiation Oncology
- Vol. 13 (1) , 186
Open AccessRadiation oncology resident training in patient safety and quality improvement: a national survey of residency program directors
Physicians and physicists are expected to contribute to patient safety and quality improvement (QI) in Radiation Oncology (RO), but prior studies suggest that training for this may be inadequate. RO and medical physics (MP) program directors (PDs) were surveyed to better understand the current patient safety/QI training in their residency programs. PDs were surveyed via email in January 2017. Survey questions inquired about current training, curriculum elements, and barriers to development and/or improvement of safety and QI training. Eighty-nine RO PDs and 84 MP PDs were surveyed, and 21 RO PDs (28%) and 31 MP PDs (37%) responded. Both RO and MP PDs had favorable opinions of current safety and QI training, and used a range of resources for program development, especially safety and QI publications. Various curriculum elements were reported. Curriculum elements used by RO and MP PDs were similar, except RO were more likely than MP PDs to implement morbidity and mortality (M&M) conference (72% vs. 45%, p < 0.05). RO and MP PDs similarly cited various barriers, but RO PDs were more likely to cite lack of experience than MP PDs (40% vs. 16%, p < 0.05). PDs responded similarly independent of whether they reported using a departmental incident learning system (ILS) or not. PDs view patient safety/QI as an important part of resident education. Most PDs agreed that residents are adequately exposed to patient safety/QI and prepared to meet the patient safety/QI expectations of clinical practice. This conflicts with other independent studies that indicate a majority of residents feel their patient safety/QI training is inadequate and lacks formal exposure to QI tools.
- Open Access
- 1 October 2017
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 99 (2) , S78-S79
Radiomic Signature Extracted from Magnetic Resonance Imaging Predicts Outcomes in Soft Tissue Sarcoma
- 1 October 2017
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 99 (2) , S78-S79
Open AccessRadiomic Signature Extracted from Magnetic Resonance Imaging Predicts Outcomes in Soft Tissue Sarcoma
- 30 August 2017
- Vol. 6 (3) , 323-335
Accuracy comparison of 4D computed tomography (4DCT) and 4D cone beam computed tomography (4DCBCT)
The ability of respiratory-correlated fan beam CT (4DCT) and respiratory-correlated cone beam CT (4DCBCT) to accurately estimate tumor volume is critical to accurate dosimetry and treatment verification for lung stereotactic body radiation therapy (SBRT) and other motion-managed therapies. However, it is known that 4DCT and 4DCBCT differ in aspects of image acquisition and reconstruction that may lead to discrepancies between the two modalities. To evaluate quantitative differences between 4DCT and 4DCBCT imaging under respiratory motion, we performed a phantom study in the ground truth setting. A programmable respiratory motion phantom was used to simulate the 1D S-I position of a known-size lesion. Ten sinusoidal and twenty patient-specific breathing waveforms were applied to drive lesion motion during the 4DCT and 4DCBCT acquisitions. The difference in lesion volume acquired between the two imaging modalities was as high as 34.4% and 18.4% for sinusoidal and patient-specific breathing motions, respectively. When compared to the true volume, 4DCT measurement often underestimated the lesion size whereas 4DCBCT overestimated the lesion volume in most of the cases. 4DCBCT gave more accurate recovery of the volume than 4DCT for most settings tested in this study. These findings may be helpful for improving the definition of internal target and planning target volume margins, and extracting quantitative information from on-board treatment verification imaging.
- 30 August 2017
- Vol. 6 (3) , 323-335
Accuracy comparison of 4D computed tomography (4DCT) and 4D cone beam computed tomography (4DCBCT)
The ability of respiratory-correlated fan beam CT (4DCT) and respiratory-correlated cone beam CT (4DCBCT) to accurately estimate tumor volume is critical to accurate dosimetry and treatment verification for lung stereotactic body radiation therapy (SBRT) and other motion-managed therapies. However, it is known that 4DCT and 4DCBCT differ in aspects of image acquisition and reconstruction that may lead to discrepancies between the two modalities. To evaluate quantitative differences between 4DCT and 4DCBCT imaging under respiratory motion, we performed a phantom study in the ground truth setting. A programmable respiratory motion phantom was used to simulate the 1D S-I position of a known-size lesion. Ten sinusoidal and twenty patient-specific breathing waveforms were applied to drive lesion motion during the 4DCT and 4DCBCT acquisitions. The difference in lesion volume acquired between the two imaging modalities was as high as 34.4% and 18.4% for sinusoidal and patient-specific breathing motions, respectively. When compared to the true volume, 4DCT measurement often underestimated the lesion size whereas 4DCBCT overestimated the lesion volume in most of the cases. 4DCBCT gave more accurate recovery of the volume than 4DCT for most settings tested in this study. These findings may be helpful for improving the definition of internal target and planning target volume margins, and extracting quantitative information from on-board treatment verification imaging.
- Open Access
- 15 November 2016
- Published by Springer Nature in Radiation Oncology
- Vol. 11 (1) , 1-7
Contribution of submandibular gland and swallowing structure sparing to post-radiation therapy PEG dependence in oropharynx cancer patients treated with split-neck IMRT technique
Radiation therapy-related dysphagia is worsened by xerostomia. The submandibular glands (SMG) produce saliva rich in lubricating mucins, and sparing the SMG has been shown to reduce xerostomia. The goal of this study was to determine whether SMG sparing IMRT is associated with reduced post-treatment PEG dependence in locally advanced oropharynx cancer patients. Patients treated with definitive radiation therapy for oropharynx cancer were included in this retrospective study. Those with disease recurrence were excluded. Salivary glands and swallowing-related organs at risk, including pharyngeal constrictors, were contoured. Primary endpoint was time from end of radiation treatment to freedom from gastrostomy (PEG) tube dependence. Cox proportional hazards regression and logistic regression were used to assess influence of normal tissue doses on swallowing related endpoints. Sixty-nine patients were included. All had stage III/IV disease and 97% received concurrent systemic therapy. Fifty-seven percent had contralateral SMG (cSMG) mean dose 42 Gy (p = 0.002). Patients treated with cSMG sparing radiotherapy had significantly shorter time to PEG tube removal after treatment, suggesting a clinically meaningful reduction in subacute dysphagia compared to non-cSMG sparing treatment.
- 15 November 2016
- Published by Springer Nature in Radiation Oncology
- Vol. 11 (1) , 1-7
Open AccessContribution of submandibular gland and swallowing structure sparing to post-radiation therapy PEG dependence in oropharynx cancer patients treated with split-neck IMRT technique
Radiation therapy-related dysphagia is worsened by xerostomia. The submandibular glands (SMG) produce saliva rich in lubricating mucins, and sparing the SMG has been shown to reduce xerostomia. The goal of this study was to determine whether SMG sparing IMRT is associated with reduced post-treatment PEG dependence in locally advanced oropharynx cancer patients. Patients treated with definitive radiation therapy for oropharynx cancer were included in this retrospective study. Those with disease recurrence were excluded. Salivary glands and swallowing-related organs at risk, including pharyngeal constrictors, were contoured. Primary endpoint was time from end of radiation treatment to freedom from gastrostomy (PEG) tube dependence. Cox proportional hazards regression and logistic regression were used to assess influence of normal tissue doses on swallowing related endpoints. Sixty-nine patients were included. All had stage III/IV disease and 97% received concurrent systemic therapy. Fifty-seven percent had contralateral SMG (cSMG) mean dose 42 Gy (p = 0.002). Patients treated with cSMG sparing radiotherapy had significantly shorter time to PEG tube removal after treatment, suggesting a clinically meaningful reduction in subacute dysphagia compared to non-cSMG sparing treatment.