Michel Mesnard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michel Mesnard has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Ramos
Departamento de Engenharia Mecânica, Universidade de Aveiro, 3810-193 Aveiro, Portugal
40 shared publications - Ricardo Duarte
Universidade do Algarve
11 shared publications - Alex Ballu
Univ. Bordeaux
7 shared publications J. Morlier
7 shared publications- Antonio Completo
Centre of Mechanical Technology and Automation (TEMA), Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
6 shared publications - Carlos Relvas
University of Aveiro
6 shared publications
Latest Publications
- 31 March 2026
- Published by PNRPU Publishing House in Russian Journal of Biomechanics
- Vol. 30 (1) , 126-134
Characterization of bone tissue distribution in the mandibular ramus for a pre-validation of an innovative temporomandibular joint prosthesis concept
In order to size a temporomandibular joint prosthesis based on an innovative concept, this study characterizes the trabecular bone tissue geometry within the joint. The main objective consists of taking into account the inter-variability of the trabecular bone volume to design a modular, even customized, innovative mandibular implant. A non-invasive method was used to describe bone tissue distribution. It involves measuring geometrical characteristics of the temporomandibular joint from computerized tomography scans using an easy and quick protocol and open-source software. The measurements performed on the scans of 68 patients showed that this high-precision method is also user-dependent. Lastly, we built value ranges to set the dimensions of a prosthesis prototype and point out a large inter-individual variability for each measurement and a low correlation between bone tissue distribution and age or gender. The software package gives precise measurements for the different parameters studied. However, the automation of the delineation of the area of trabecular bone should improve reproducibility. Also, the protocol can be applied to other medical specialties. Used in the context of a design for an innovative temporomandibular joint prosthesis, it points out a strong inter-individual heterogeneity in the distribution of bone tissue, which leads to prefer a modular implant design.
- 31 March 2026
- Published by PNRPU Publishing House in Russian Journal of Biomechanics
- Vol. 30 (1) , 126-134
Characterization of bone tissue distribution in the mandibular ramus for a pre-validation of an innovative temporomandibular joint prosthesis concept
In order to size a temporomandibular joint prosthesis based on an innovative concept, this study characterizes the trabecular bone tissue geometry within the joint. The main objective consists of taking into account the inter-variability of the trabecular bone volume to design a modular, even customized, innovative mandibular implant. A non-invasive method was used to describe bone tissue distribution. It involves measuring geometrical characteristics of the temporomandibular joint from computerized tomography scans using an easy and quick protocol and open-source software. The measurements performed on the scans of 68 patients showed that this high-precision method is also user-dependent. Lastly, we built value ranges to set the dimensions of a prosthesis prototype and point out a large inter-individual variability for each measurement and a low correlation between bone tissue distribution and age or gender. The software package gives precise measurements for the different parameters studied. However, the automation of the delineation of the area of trabecular bone should improve reproducibility. Also, the protocol can be applied to other medical specialties. Used in the context of a design for an innovative temporomandibular joint prosthesis, it points out a strong inter-individual heterogeneity in the distribution of bone tissue, which leads to prefer a modular implant design.
- 18 May 2023
- Published by Elsevier in Journal of Stomatology Oral and Maxillofacial Surgery
- Vol. 124 (5) , 101512
Bone density and proximal support effects on dental implant stability – Finite element analysis and in vitro experiments
- 18 May 2023
- Published by Elsevier in Journal of Stomatology Oral and Maxillofacial Surgery
- Vol. 124 (5) , 101512
Bone density and proximal support effects on dental implant stability – Finite element analysis and in vitro experiments
- 1 January 2023
- Published by Springer Nature
- p. 379-389
Experimental Study of the Influence of Cervical Disc Mechanical Properties on the Strain Distribution in Adjacent Vertebrae
- 1 January 2023
- Published by Springer Nature
- p. 379-389
Experimental Study of the Influence of Cervical Disc Mechanical Properties on the Strain Distribution in Adjacent Vertebrae
- 1 June 2021
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 59 (5) , 546-554
Review of expandable dental implants
- 1 June 2021
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 59 (5) , 546-554
Review of expandable dental implants
- 12 November 2020
- Published by Taylor & Francis in Mechanics of Advanced Materials and Structures
- Vol. 29 (12) , 1674-1691
Topography and wettability characterization of surfaces manufactured by SLM and treated by chemical etching
Selective Laser Melting process represents an interesting opportunity in the biomedical field to fabricate customized implants. However, the surface roughness of components obtained through additive manufacturing is a major limitation and affects the surface wettability. In the present work, chemical etching is adopted to deal with such an issue. To do so, the effects of chemical etching parameters (such as immersion time and composition of the solution) on the surface roughness, weight loss and wettability is analyzed. Different samples (obtained through different printing orientations) are considered. The tests show that the roughness and the wetting of the surfaces are improved thanks to chemical etching. As a major result, the most influencing parameters on surface wetting are two: the roughness and the material properties (which vary with samples depth).
- 12 November 2020
- Published by Taylor & Francis in Mechanics of Advanced Materials and Structures
- Vol. 29 (12) , 1674-1691
Topography and wettability characterization of surfaces manufactured by SLM and treated by chemical etching
Selective Laser Melting process represents an interesting opportunity in the biomedical field to fabricate customized implants. However, the surface roughness of components obtained through additive manufacturing is a major limitation and affects the surface wettability. In the present work, chemical etching is adopted to deal with such an issue. To do so, the effects of chemical etching parameters (such as immersion time and composition of the solution) on the surface roughness, weight loss and wettability is analyzed. Different samples (obtained through different printing orientations) are considered. The tests show that the roughness and the wetting of the surfaces are improved thanks to chemical etching. As a major result, the most influencing parameters on surface wetting are two: the roughness and the material properties (which vary with samples depth).
- Open Access
- 19 October 2020
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 23 (sup1) , S178-S179
Influence of dental implant designs on the strain at the peri-implant cortical bone: a finite element study
- 19 October 2020
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 23 (sup1) , S178-S179
Open AccessInfluence of dental implant designs on the strain at the peri-implant cortical bone: a finite element study
- 1 July 2020
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 58 (6) , 652-658
Study of fixation of a mandibular plate for favourable fractures of the mandibular angle: numerical predictions
- 1 July 2020
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 58 (6) , 652-658
Study of fixation of a mandibular plate for favourable fractures of the mandibular angle: numerical predictions
- 4 February 2019
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 22 (4) , 352-363
Predictions of Birmingham hip resurfacing implant offset - In vitro and numerical models
The number of hip resurfacing arthroplasty procedures has declined dramatically in recent years, for reasons related to the survival rate. Some studies suggest that metal particles are the main critical problem, but do not specify the effect of femoral position on the failure rate. The present study aims to analyze whether the positioning of the resurfacing head implant is important in the distribution of bone strains and in the risk of fracture of the femur. Three in vitro experimental models received the Birmingham hip resurfacing implant to replicate the total hip joint. The resurfacing head of the implanted models was placed in three different offset positions: in a positive offset, with the same femoral head center and in a negative offset. The numerical models were validated by correlating numerical and experimental results. Comparing experimental results from the implanted and intact femurs highlights a strain increase of up to 48% in the proximal medial femur region for positive offset and up to 18% in the neutral position. A reduction of 72% for negative offset (valgus position) was also measured experimentally. A significant change in strain distributions was observed with a resurfacing hip system and increased risk of neck fracture was found using the resurfacing head in positive offset. The iliac bone presents a high decrease in strains that will induce bone loss in the long term. Among the offset positions tested, results suggest that the negative offset (valgus position) and the natural position are the best equilibrated for better long-term results.
- 4 February 2019
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 22 (4) , 352-363
Predictions of Birmingham hip resurfacing implant offset - In vitro and numerical models
The number of hip resurfacing arthroplasty procedures has declined dramatically in recent years, for reasons related to the survival rate. Some studies suggest that metal particles are the main critical problem, but do not specify the effect of femoral position on the failure rate. The present study aims to analyze whether the positioning of the resurfacing head implant is important in the distribution of bone strains and in the risk of fracture of the femur. Three in vitro experimental models received the Birmingham hip resurfacing implant to replicate the total hip joint. The resurfacing head of the implanted models was placed in three different offset positions: in a positive offset, with the same femoral head center and in a negative offset. The numerical models were validated by correlating numerical and experimental results. Comparing experimental results from the implanted and intact femurs highlights a strain increase of up to 48% in the proximal medial femur region for positive offset and up to 18% in the neutral position. A reduction of 72% for negative offset (valgus position) was also measured experimentally. A significant change in strain distributions was observed with a resurfacing hip system and increased risk of neck fracture was found using the resurfacing head in positive offset. The iliac bone presents a high decrease in strains that will induce bone loss in the long term. Among the offset positions tested, results suggest that the negative offset (valgus position) and the natural position are the best equilibrated for better long-term results.
- Open Access
- 5 December 2018
- Published by EDP Sciences in Matériaux & Techniques
- Vol. 106 (4) , 405
Determinants of the surface quality, density and dimensional correctness in selective laser melting of the Ti-13Zr-13Nb alloy
Selective laser melting is widely used for custom-designed elements. Successful manufacturing depends on laser treatment parameters and material features. This research aimed to determine the effects of laser power, scan time and hatch distance on surface quality, relative density and dimensional precision for cuboids made of the Ti-13Zr-13Nb alloy. The influence of energy density, energy flux and pre-heating was seen to be decisive to different degrees for the quality of the final specimen. The results obtained were used to produce prosthetic crowns and bridges. The thermal stresses that appeared resulted in a deflection of the bridges and consequently in a change in design approach.
- 5 December 2018
- Published by EDP Sciences in Matériaux & Techniques
- Vol. 106 (4) , 405
Open AccessDeterminants of the surface quality, density and dimensional correctness in selective laser melting of the Ti-13Zr-13Nb alloy
Selective laser melting is widely used for custom-designed elements. Successful manufacturing depends on laser treatment parameters and material features. This research aimed to determine the effects of laser power, scan time and hatch distance on surface quality, relative density and dimensional precision for cuboids made of the Ti-13Zr-13Nb alloy. The influence of energy density, energy flux and pre-heating was seen to be decisive to different degrees for the quality of the final specimen. The results obtained were used to produce prosthetic crowns and bridges. The thermal stresses that appeared resulted in a deflection of the bridges and consequently in a change in design approach.
- 16 November 2018
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 47 (1) , 112-119
Ex-vivo and in vitro validation of an innovative mandibular condyle implant concept
- 16 November 2018
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 47 (1) , 112-119
Ex-vivo and in vitro validation of an innovative mandibular condyle implant concept