PPPradeep Mathew Poonnoose

Pradeep Mathew Poonnoose

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pradeep Mathew Poonnoose has a total of 140 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Enhanced Functional Independence Score for Haemophilia (E‐FISH) for Early Detection of Musculoskeletal Changes

    by Sanjeev Manasseh Padankatti, S Priyadarshini, Ronald Thomvic, Paul Jebaraj, Grace Elizabeth Muppidi, Divya Jebaraj, Kavitha M Lakshmi, Tunny Sebastian, Judy Ann David, Pradeep Mathew Poonnoose, et al.

    Background: The functional independence score in haemophilia (FISH) is a widely used performance‐based assessment tool designed to evaluate musculoskeletal function in children with haemophilia (CWH). Nevertheless, FISH exhibits a ceiling effect in children who are undergoing early prophylaxis or those who present with minimal musculoskeletal impairment. This report describes the development of an enhanced FISH (e‐FISH) with more challenging tasks to detect early physical function changes in CWH. Methods: Two performance‐based assessments, the basketball throw test (BBT) and the 10×5‐meter sprint test (ST) were included as a subtest of FISH. Age‐specific normative scores were established from healthy boys. A scoring system, which ranges from 1–4, was created and compared with CWH, who showed no joint deformities after obtaining the necessary consent and assent. Results: Twenty CWH with FISH scores ranging from 31–32 and on prophylactic treatment with clotting factor concentrate were evaluated using these two tests. Only one (5%) CWH attained a higher score of 4 in both assessments. In the BBT, two (10%) achieved a score of 3, six (30%) received a score of 2, and 11 (55%) were assigned an e‐FISH score of 1. In the 10×5 meter ST, eight (40%) scored 3, one (5%) scored 2, and 10 (50%) scored 1 in e‐FISH. No bleeding was reported. Conclusion: We have created e‐FISH as a clinimetric instrument designed for the assessment of individuals with CWH who may exhibit minimal musculoskeletal alterations and demonstrate a ceiling effect when using FISH.

  • Classification of Crowe-IV developmental dysplasia of hip based on proximal femoral morphology and its implications during total hip arthroplasty

    by Krishna Kiran Eachempati, Apurve Parameswaran, Vinay Kishore Ratnakar Ponnala, Rajesh Malhotra, Deepak Gautam, Anil Thomas Oommen, Pradeep Mathew Poonnoose, Neil P. Sheth

  • Horizontal offset variation, correlation with neck shaft angle in primary and complex total hip arthroplasty

    by Alen John Alex, Augustine Jaison Paul, Jozy Timothy, S. Gokulprasath, Pradeep Mathew Poonnoose, Anil Thomas Oommen


  • Non‐surgical correction of knee flexion deformity in persons with haemophilia: A staged multidisciplinary approach

    by Merlyn Tilak, Judy Ann John, Arun Paul, Anumeha Srivastava, Divya Singh, Andriya Rajendran, Prince Thakkar, Naveen Cherian, Sandeep Albert, Pradeep Poonnoose, et al.

    IntroductionFlexion deformity of the knee is a common complication following recurrent haemarthrosis in persons with haemophilia (PWH) on episodic factor replacement therapy, restricting independent mobility. There is limited literature on the comprehensive management of this condition. This report provides the outcome of a staged multidisciplinary approach for the correction of knee flexion deformity (KFD) even in limited resource settings.Patients and methodsThe data of 49 consecutive PWH who were treated for KFD were analysed. The approach included graded physical therapy (PT), followed by serial casting and/or mobilisation under anaesthesia (MUA). MUA was done in carefully selected knees. Surgical correction was opted when non-surgical methods failed.ResultsOf the 49 patients (55 knees), with a median KFD of 40 degrees (range: 10-90), 26/55 (47%) were corrected by graded PT. With serial casting, 9/19 (47%) knees had their KFD corrected. MUA was done for 11 knees of which five achieved correction (45%). Surgical correction was required for only seven knees (12.7%). Following this approach, KFD improved from 40 degrees (range: 10-90) to 15 degrees (range: 0-40), with only minor loss of flexion from 105 (range: 60-155) to 90 degrees (range: 30-150). Out of 55 KFD, 46 (83.6%) KFD were corrected; non-surgical, 39 (70.9%) and surgery, seven (12.7%). The remaining patients (nine KFD; 16.4%) were able to achieve their functional goal despite not meeting the correction criteria.ConclusionThis study shows that in PWH, functionally significant KFD correction can be achieved in about 71%, through non-surgical methods, even without prophylactic factor replacement.

  • Mobilization under anaesthesia for correction of knee flexion deformity in haemophilia

    by Prince Thakkar, Judy Ann John, Raji Thomas, Merlyn Tilak, Madhavi Kandagaddala, Pradeep Poonnoose, Nambiathayil Abubacker Fouzia, Aby Abrahm, Alok Srivastava

    Introduction: Haemophilia patients not treated with primary or secondary prophylaxis, often present with recurrent haemarthrosis. Knee is the most frequently involved joint leading to disabling knee flexion deformity (KFD). Here, we present a retrospective study of our experience on the role of mobilization under general anaesthesia in the correction of KFD.Aim: To study the effectiveness of mobilization under anaesthesia (MUA) for correction of knee flexion deformity (KFD) in persons with haemophilia (PWH).Methods: Outcome of all patients managed with MUA in our multidisciplinary haemophilia clinic from 2008 to 2019 were included for analysis. PWH with KFD > 20 degree who underwent MUA were included in the study. Under general anaesthesia and cover of clotting factor replacement, gentle joint mobilization was done to achieve maximal correction in flexion deformity, followed by above knee casting in this position. The outcome measures assessed were reduction in knee flexion deformity following MUA and complications, if any.Results: Thirty patients (34 knees) with knee flexion deformity were included in the study. Mean age of the study population was 14.23 years +/- 8.3. Study population was analysed in two groups, Group 1 included patients who underwent single MUA and Group 2, patients who underwent two or more MUA. There was significant improvement in KFD correction in both groups. [Group 1; Mean difference: 22 +/- 13.7, p value -0.01, 95% CI (16.4-27.5) and Group 2; Mean difference 48.8 +/- 19.8, p value -0.00, 95% CI (34.2-64.5)].Conclusion: MUA can be effective in the short-term correction of KFD in PWH particularly those below 15 years of age. It should be done judiciously when target correction is not achieved with other physical methods.


  • Perception of Perioperative Risk for Arthroplasty Patients: A Poll of Indian Orthopedic Surgeons

    by David G. Campbell, Pradeep M. Poonnoose, Anil T. Oommen, Rajkumar Natesan


  • Open Access

    Spinopelvic Mobility Pattern and Acetabular Anteversion in Stiff Hips With Ankylosing Spondylitis After Total Hip Arthroplasty

    by Anil Thomas Oommen, Triplicane Dwarakanathan Hariharan, Madhavi Kandagaddala, Viruthipadavil John Chandy, Pradeep Mathew Poonnoose, A. Arun Shankar


  • Peri-operative Morbidity Associated with Bilateral Hip Arthroplasty for Inflammatory Arthritis: Results from a Consecutive Series of 168 Hips

    by Rahul George, V. J. Chandy, A. I. Christudoss, T. D. Hariharan, A. ArunShankar, B. Antonisamy, A. T. Oommen, Pradeep Mathew Poonnoose

    Aim This study aims to assess the risks and peri-operative morbidity associated with a single-stage sequential bilateral hip arthroplasty (SBHA) when performed in patients with arthritis secondary to inflammatory arthropathy. Methods Data of patients who underwent SBHA between 2012 and 2018 for inflammatory arthritis were extracted from a database, for peri-operative complications and functional improvement. SBHA for other causes was excluded. Results Data of 84 consecutive patients with a mean age of 34.5 years were analyzed. The mean follow-up was 2.4 years. 66% had ankylosing spondylitis, while 14% had rheumatoid arthritis. 50% of the patients had bilateral fusion of the hips, and 34% had flexion deformity > 30°. None of the patients had peri-operative cardiac or pulmonary complications. 2.4% had per-operative hypotension (MAP < 50 mmHg) and 1.2% had desaturation (SpO2 < 90%). The mean drop in hematocrit was 9.3%. While 31% did not require blood transfusion, 35% required more than 1 unit of blood. Patients with pre-operative PCV of > 36% had a significantly lower risk of being transfused > 1 unit of blood (p = 0.02). ICU admission was 6%—mostly for post-operative monitoring. While one patient had a local hematoma that needed a wash-out, there were no infections, dislocations, or mortality in these patients. The modified Harris hip score improved from a mean of 26.5–85. The mean hip flexion improved post-operatively from 32° to 92°. Conclusions SBHA for inflammatory arthritis can be performed with minimum complications in a multidisciplinary setting. Pre-operatively, PCV of > 36 is advised to reduce transfusion rates.


  • Ultrasound and magnetic resonance imaging for the detection of blood: An ex‐vivo study

    by Soumya Susan Regi, Roshan S. Livingstone, Madhavi Kandagaddala, Pradeep Poonnoose, Sridhar Gibikote, Shyamkumar N. Keshava, Alok Srivastava

    Objectives: Early detection of bleeding into a joint is crucial in patients with haemophilia. This study was designed to evaluate the sensitivity of ultrasonography (USG) and magnetic resonance imaging (MRI) to detect the presence of blood in small concentrations in a simulated model to mimic joint bleeding.Materials and Methods: Different concentrations of blood in plasma, varying from 0.1% to 45%, were collected in 10‐ml plastic syringes and imaged using 12 and 18 MHz USG transducers and with 1.5T and 3T MRI scanners, at different intervals of time following dilution. The images were scored for the presence of blood by four experienced radiologists who were blinded to the concentration of blood.Results: Within the first 2 h, the 18 MHz transducer was able to detect blood consistently up to 0.5%, whereas the 12 MHz transducer could consistently identify blood up to 1.4%. After the first 12 h, both transducers were able to detect blood up to 0.5% concentration. However, at concentrations below 0.5%, there was discordance in the ability to detect blood, with both transducers. There was no correlation between the signal intensities of MRI images and concentration of blood, at different time intervals, irrespective of the magnetic field strength.Conclusions: Detection of blood using the USG is dependent on variables such as the concentration of blood, frequency of the transducer used and timing of the imaging. As the concentration of blood decreases below 0.5%, the discordance between the observers increases, implying that the detection limit of USG affects its reliability at lower concentrations of blood. Caution is urged while interpreting USG imaging studies for the detection of blood in symptomatic joints.