Amy Davies
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Amy Davies has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Colin Rickman
Heriot-Watt Univ. (United Kingdom)
6 shared publications - Paul A. Dalgarno
Heriot-Watt Univ. (United Kingdom)
6 shared publications - Rory R. Duncan
Heriot-Watt University
6 shared publications Neale A. W. Dutton
STMicroelectronics Ltd. (United Kingdom)
4 shared publicationsIstvan Gyongy
The Univ. of Edinburgh (United Kingdom)
3 shared publicationsRobert K. Henderson
The Univ. of Edinburgh (United Kingdom)
3 shared publications
Latest Publications
- Open Access
- 4 January 2021
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (3) , 789-802
Recent advances in the use of stimulated Raman scattering in histopathology
Stimulated Raman histopathology (SRH) utilises the intrinsic vibrational properties of lipids, proteins and nucleic acids to generate contrast providing rapid image acquisition that allows visualisation of histopathological features. It is currently being trialled in the intraoperative setting, where the ability to image unprocessed samples rapidly and with high resolution offers several potential advantages over the use of conventional haematoxylin and eosin stained images. Here we review recent advances in the field including new updates in instrumentation and computer aided diagnosis. We also discuss how other non-linear modalities can be used to provide additional diagnostic contrast which together pave the way for enhanced histopathology and open up possibilities for in vivo pathology.
- 4 January 2021
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (3) , 789-802
Open AccessRecent advances in the use of stimulated Raman scattering in histopathology
Stimulated Raman histopathology (SRH) utilises the intrinsic vibrational properties of lipids, proteins and nucleic acids to generate contrast providing rapid image acquisition that allows visualisation of histopathological features. It is currently being trialled in the intraoperative setting, where the ability to image unprocessed samples rapidly and with high resolution offers several potential advantages over the use of conventional haematoxylin and eosin stained images. Here we review recent advances in the field including new updates in instrumentation and computer aided diagnosis. We also discuss how other non-linear modalities can be used to provide additional diagnostic contrast which together pave the way for enhanced histopathology and open up possibilities for in vivo pathology.
- 4 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10889, 24
Fluorescence lifetime imaging of high-speed particles with single-photon image sensors
The capability of Single-Photon Avalanche Diodes (SPADs) to detect photons with picosecond timing precision and shotnoise limited performance has given rise to a range of biological and biomedical applications, from Fluorescence Lifetime Imaging Microscopy (FLIM) to Raman Spectroscopy and Positron Emission Tomography (PET). The use of SPAD sensors has also been successfully demonstrated in Single-Molecule Localisation Microscopy. Traditionally implemented as point detectors, recent advances in SPAD technology, such as compact, binary pixels and back-side illuminated, 3D-stacked architectures, have led to 2-D imaging arrays of increasing resolution and fill factor. Combined with high frame rates (in the kFPS range), and negligible read noise, the sensors offer an exciting prospect for capturing fast temporal dynamics in life science cellular imaging. The work in this paper considers the application of SPAD imaging arrays to widefield fluorescence lifetime imaging of high-speed particles in microscopy. We demonstrate, using a time-gated binary SPAD array, that by tracking particles, and spatially re-assigning the underlying photon counts accordingly, lifetime estimates for fast-moving objects are possible. Moreover, we give the first demonstration of FLIM using a SPAD imaging array with on-chip histogramming of photon arrival time, with potential frame rates of several 100FPS. Both FLIM techniques are illustrated using experimental results based on fluorescent microspheres undergoing Brownian motion. The results pave the way towards applications in live-cell microscopy, such as the monitoring of the fluorescence lifetime of highly mobile cell structures, with a view, for example, to study molecular interactions using Förster Resonance Energy Transfer (FRET) measurements.
- 4 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10889, 24
Fluorescence lifetime imaging of high-speed particles with single-photon image sensors
The capability of Single-Photon Avalanche Diodes (SPADs) to detect photons with picosecond timing precision and shotnoise limited performance has given rise to a range of biological and biomedical applications, from Fluorescence Lifetime Imaging Microscopy (FLIM) to Raman Spectroscopy and Positron Emission Tomography (PET). The use of SPAD sensors has also been successfully demonstrated in Single-Molecule Localisation Microscopy. Traditionally implemented as point detectors, recent advances in SPAD technology, such as compact, binary pixels and back-side illuminated, 3D-stacked architectures, have led to 2-D imaging arrays of increasing resolution and fill factor. Combined with high frame rates (in the kFPS range), and negligible read noise, the sensors offer an exciting prospect for capturing fast temporal dynamics in life science cellular imaging. The work in this paper considers the application of SPAD imaging arrays to widefield fluorescence lifetime imaging of high-speed particles in microscopy. We demonstrate, using a time-gated binary SPAD array, that by tracking particles, and spatially re-assigning the underlying photon counts accordingly, lifetime estimates for fast-moving objects are possible. Moreover, we give the first demonstration of FLIM using a SPAD imaging array with on-chip histogramming of photon arrival time, with potential frame rates of several 100FPS. Both FLIM techniques are illustrated using experimental results based on fluorescent microspheres undergoing Brownian motion. The results pave the way towards applications in live-cell microscopy, such as the monitoring of the fluorescence lifetime of highly mobile cell structures, with a view, for example, to study molecular interactions using Förster Resonance Energy Transfer (FRET) measurements.
- 20 February 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10505, 105050A
High-speed particle tracking in microscopy using SPAD image sensors
Single photon avalanche diodes (SPADs) are used in a wide range of applications, from fluorescence lifetime imaging microscopy (FLIM) to time-of-flight (ToF) 3D imaging. SPAD arrays are becoming increasingly established, combining the unique properties of SPADs with widefield camera configurations. Traditionally, the photosensitive area (fill factor) of SPAD arrays has been limited by the in-pixel digital electronics. However, recent designs have demonstrated that by replacing the complex digital pixel logic with simple binary pixels and external frame summation, the fill factor can be increased considerably. A significant advantage of such binary SPAD arrays is the high frame rates offered by the sensors (>100kFPS), which opens up new possibilities for capturing ultra-fast temporal dynamics in, for example, life science cellular imaging. In this work we consider the use of novel binary SPAD arrays in high-speed particle tracking in microscopy. We demonstrate the tracking of fluorescent microspheres undergoing Brownian motion, and in intra-cellular vesicle dynamics, at high frame rates. We thereby show how binary SPAD arrays can offer an important advance in live cell imaging in such fields as intercellular communication, cell trafficking and cell signaling.
- 20 February 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10505, 105050A
High-speed particle tracking in microscopy using SPAD image sensors
Single photon avalanche diodes (SPADs) are used in a wide range of applications, from fluorescence lifetime imaging microscopy (FLIM) to time-of-flight (ToF) 3D imaging. SPAD arrays are becoming increasingly established, combining the unique properties of SPADs with widefield camera configurations. Traditionally, the photosensitive area (fill factor) of SPAD arrays has been limited by the in-pixel digital electronics. However, recent designs have demonstrated that by replacing the complex digital pixel logic with simple binary pixels and external frame summation, the fill factor can be increased considerably. A significant advantage of such binary SPAD arrays is the high frame rates offered by the sensors (>100kFPS), which opens up new possibilities for capturing ultra-fast temporal dynamics in, for example, life science cellular imaging. In this work we consider the use of novel binary SPAD arrays in high-speed particle tracking in microscopy. We demonstrate the tracking of fluorescent microspheres undergoing Brownian motion, and in intra-cellular vesicle dynamics, at high frame rates. We thereby show how binary SPAD arrays can offer an important advance in live cell imaging in such fields as intercellular communication, cell trafficking and cell signaling.
- 23 January 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (3) , 2280-2291
Cylindrical microlensing for enhanced collection efficiency of small pixel SPAD arrays in single-molecule localisation microscopy
Single-photon avalanche photodiode (SPAD) image sensors offer time-gated photon counting, at high binary frame rates of >100 kFPS and with no readout noise. This makes them well-suited to a range of scientific applications, including microscopy, sensing and quantum optics. However, due to the complex electronics required, the fill factor tends to be significantly lower (< 10%) than that of EMCCD and sCMOS cameras (>90%), whilst the pixel size is typically larger, impacting the sensitivity and practicalities of the SPAD devices. This paper presents the first characterisation of a cylindrical-shaped microlens array applied to a small, 8 micron, pixel SPAD imager. The enhanced fill factor, ≈50% for collimated light, is the highest reported value amongst SPAD sensors with comparable resolution and pixel pitch. We demonstrate the impact of the increased sensitivity in single-molecule localisation microscopy, obtaining a resolution of below 40nm, the best reported figure for a SPAD sensor.
- 23 January 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (3) , 2280-2291
Cylindrical microlensing for enhanced collection efficiency of small pixel SPAD arrays in single-molecule localisation microscopy
Single-photon avalanche photodiode (SPAD) image sensors offer time-gated photon counting, at high binary frame rates of >100 kFPS and with no readout noise. This makes them well-suited to a range of scientific applications, including microscopy, sensing and quantum optics. However, due to the complex electronics required, the fill factor tends to be significantly lower (< 10%) than that of EMCCD and sCMOS cameras (>90%), whilst the pixel size is typically larger, impacting the sensitivity and practicalities of the SPAD devices. This paper presents the first characterisation of a cylindrical-shaped microlens array applied to a small, 8 micron, pixel SPAD imager. The enhanced fill factor, ≈50% for collimated light, is the highest reported value amongst SPAD sensors with comparable resolution and pixel pitch. We demonstrate the impact of the increased sensitivity in single-molecule localisation microscopy, obtaining a resolution of below 40nm, the best reported figure for a SPAD sensor.
- Open Access
- 21 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 65 (2) , 547-554
A $256\times256$ , 100-kfps, 61% Fill-Factor SPAD Image Sensor for Time-Resolved Microscopy ApplicationsA 256 x256 single-photon avalanche diode image sensor operating at 100 kfps with fill factor of 61% and pixel pitch of 16 μm is reported. An all-nMOS 7T pixel allows gated operation down to 4 ns and ~600-ps fall time with on-chip delay generation. The sensor operates with 0.996 temporal aperture ratio in rolling shutter. Gating and cooling allow the suppression of dark noise, which, in combination with the high fill factor, enables competitive low-light performance with electron multiplying charge-coupled devices while offering time-resolved imaging modes.
- 21 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 65 (2) , 547-554
Open AccessA $256\times256$ , 100-kfps, 61% Fill-Factor SPAD Image Sensor for Time-Resolved Microscopy ApplicationsA 256 x256 single-photon avalanche diode image sensor operating at 100 kfps with fill factor of 61% and pixel pitch of 16 μm is reported. An all-nMOS 7T pixel allows gated operation down to 4 ns and ~600-ps fall time with on-chip delay generation. The sensor operates with 0.996 temporal aperture ratio in rolling shutter. Gating and cooling allow the suppression of dark noise, which, in combination with the high fill factor, enables competitive low-light performance with electron multiplying charge-coupled devices while offering time-resolved imaging modes.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 8.2.1-8.2.4
256×256, 100kfps, 61% Fill-factor time-resolved SPAD image sensor for microscopy applications
A 256×256 Single Photon Avalanche Diode (SPAD) image sensor operating at 100kfps with fill factor of 61% and pixel pitch of 16μm is reported. An all-NMOS 7T pixel allows high uniformity gated operation down to 4ns and ~600ps fall time with on-chip delay generation. The sensor operates with 0.996 temporal aperture ratio (TAR) in rolling shutter and has a parasitic light sensitivity (PLS) in excess of -160dB when operated in global shutter. Gating and cooling allow the suppression of dark noise, which, in combination with the high fill factor, enables competitive low-light performance with electron multiplying CCDs (EMCCDs) whilst offering time-resolved imaging modes.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 8.2.1-8.2.4
256×256, 100kfps, 61% Fill-factor time-resolved SPAD image sensor for microscopy applications
A 256×256 Single Photon Avalanche Diode (SPAD) image sensor operating at 100kfps with fill factor of 61% and pixel pitch of 16μm is reported. An all-NMOS 7T pixel allows high uniformity gated operation down to 4ns and ~600ps fall time with on-chip delay generation. The sensor operates with 0.996 temporal aperture ratio (TAR) in rolling shutter and has a parasitic light sensitivity (PLS) in excess of -160dB when operated in global shutter. Gating and cooling allow the suppression of dark noise, which, in combination with the high fill factor, enables competitive low-light performance with electron multiplying CCDs (EMCCDs) whilst offering time-resolved imaging modes.
- Open Access
- 23 November 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 37349
Smart-aggregation imaging for single molecule localisation with SPAD cameras
Single molecule localisation microscopy (SMLM) has become an essential part of the super-resolution toolbox for probing cellular structure and function. The rapid evolution of these techniques has outstripped detector development and faster, more sensitive cameras are required to further improve localisation certainty. Single-photon avalanche photodiode (SPAD) array cameras offer single-photon sensitivity, very high frame rates and zero readout noise, making them a potentially ideal detector for ultra-fast imaging and SMLM experiments. However, performance traditionally falls behind that of emCCD and sCMOS devices due to lower photon detection efficiency. Here we demonstrate, both experimentally and through simulations, that the sensitivity of a binary SPAD camera in SMLM experiments can be improved significantly by aggregating only frames containing signal, and that this leads to smaller datasets and competitive performance with that of existing detectors. The simulations also indicate that with predicted future advances in SPAD camera technology, SPAD devices will outperform existing scientific cameras when capturing fast temporal dynamics.
- 23 November 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 37349
Open AccessSmart-aggregation imaging for single molecule localisation with SPAD cameras
Single molecule localisation microscopy (SMLM) has become an essential part of the super-resolution toolbox for probing cellular structure and function. The rapid evolution of these techniques has outstripped detector development and faster, more sensitive cameras are required to further improve localisation certainty. Single-photon avalanche photodiode (SPAD) array cameras offer single-photon sensitivity, very high frame rates and zero readout noise, making them a potentially ideal detector for ultra-fast imaging and SMLM experiments. However, performance traditionally falls behind that of emCCD and sCMOS devices due to lower photon detection efficiency. Here we demonstrate, both experimentally and through simulations, that the sensitivity of a binary SPAD camera in SMLM experiments can be improved significantly by aggregating only frames containing signal, and that this leads to smaller datasets and competitive performance with that of existing detectors. The simulations also indicate that with predicted future advances in SPAD camera technology, SPAD devices will outperform existing scientific cameras when capturing fast temporal dynamics.
- Open Access
- 1 June 2015
- Published by Springer Nature in Nature Communications
- Vol. 6 (1) , 7254
Platelet actin nodules are podosome-like structures dependent on Wiskott–Aldrich syndrome protein and ARP2/3 complex
The actin nodule is a novel F-actin structure present in platelets during early spreading. However, only limited detail is known regarding nodule organization and function. Here we use electron microscopy, SIM and dSTORM super-resolution, and live-cell TIRF microscopy to characterize the structural organization and signalling pathways associated with nodule formation. Nodules are composed of up to four actin-rich structures linked together by actin bundles. They are enriched in the adhesion-related proteins talin and vinculin, have a central core of tyrosine phosphorylated proteins and are depleted of integrins at the plasma membrane. Nodule formation is dependent on Wiskott–Aldrich syndrome protein (WASp) and the ARP2/3 complex. WASp−/− mouse blood displays impaired platelet aggregate formation at arteriolar shear rates. We propose actin nodules are platelet podosome-related structures required for platelet–platelet interaction and their absence contributes to the bleeding diathesis of Wiskott–Aldrich syndrome.
- 1 June 2015
- Published by Springer Nature in Nature Communications
- Vol. 6 (1) , 7254
Open AccessPlatelet actin nodules are podosome-like structures dependent on Wiskott–Aldrich syndrome protein and ARP2/3 complex
The actin nodule is a novel F-actin structure present in platelets during early spreading. However, only limited detail is known regarding nodule organization and function. Here we use electron microscopy, SIM and dSTORM super-resolution, and live-cell TIRF microscopy to characterize the structural organization and signalling pathways associated with nodule formation. Nodules are composed of up to four actin-rich structures linked together by actin bundles. They are enriched in the adhesion-related proteins talin and vinculin, have a central core of tyrosine phosphorylated proteins and are depleted of integrins at the plasma membrane. Nodule formation is dependent on Wiskott–Aldrich syndrome protein (WASp) and the ARP2/3 complex. WASp−/− mouse blood displays impaired platelet aggregate formation at arteriolar shear rates. We propose actin nodules are platelet podosome-related structures required for platelet–platelet interaction and their absence contributes to the bleeding diathesis of Wiskott–Aldrich syndrome.
- 20 January 2012
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 109 (6) , 1862-1867
pH-controlled delivery of luminescent europium coated nanoparticles into platelets
Water soluble, luminescent gold nanoparticles are delivered into human platelets via a rapid, pH-controlled mechanism using a pH low insertion peptide, pHLIP . The approach introduces cocoating of gold nanoparticles with a europium luminescent complex, EuL and the pHLIP peptide to give pHLIP • EuL • Au . The 13-nm diameter gold nanoparticles act as a scaffold for the attachment of both the luminescent probe and the peptide to target delivery. Their size allows delivery of approximately 640 lanthanide probes per nanoparticle to be internalized in human platelets, which are not susceptible to transfection or microinjection. The internalization of pHLIP • EuL • Au in platelets, which takes just minutes, was studied with a variety of imaging modalities including luminescence, confocal reflection, and transmission electron microscopy. The results show that pHLIP • EuL • Au only enters the platelets in low pH conditions, pH 6.5, mediated by the pHLIP translocation across the membrane, and not at pH 7.4. Luminescence microscopy images of the treated platelets show clearly the red luminescence signal from the europium probe and confocal reflection microscopy confirms the presence of the gold particles. Furthermore, transmission electron microscopy gives a detailed insight of the internalization and spatial localization of the gold nanoparticles in the platelets. Thus, we demonstrate the potential of the design to translocate multimodal nanoparticle probes into cells in a pH dependent manner.
- 20 January 2012
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 109 (6) , 1862-1867
pH-controlled delivery of luminescent europium coated nanoparticles into platelets
Water soluble, luminescent gold nanoparticles are delivered into human platelets via a rapid, pH-controlled mechanism using a pH low insertion peptide, pHLIP . The approach introduces cocoating of gold nanoparticles with a europium luminescent complex, EuL and the pHLIP peptide to give pHLIP • EuL • Au . The 13-nm diameter gold nanoparticles act as a scaffold for the attachment of both the luminescent probe and the peptide to target delivery. Their size allows delivery of approximately 640 lanthanide probes per nanoparticle to be internalized in human platelets, which are not susceptible to transfection or microinjection. The internalization of pHLIP • EuL • Au in platelets, which takes just minutes, was studied with a variety of imaging modalities including luminescence, confocal reflection, and transmission electron microscopy. The results show that pHLIP • EuL • Au only enters the platelets in low pH conditions, pH 6.5, mediated by the pHLIP translocation across the membrane, and not at pH 7.4. Luminescence microscopy images of the treated platelets show clearly the red luminescence signal from the europium probe and confocal reflection microscopy confirms the presence of the gold particles. Furthermore, transmission electron microscopy gives a detailed insight of the internalization and spatial localization of the gold nanoparticles in the platelets. Thus, we demonstrate the potential of the design to translocate multimodal nanoparticle probes into cells in a pH dependent manner.