Nicolas Vachicouras
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nicolas Vachicouras has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
- Stephanie P. Lacour
École Polytechnique Fédérale de Lausanne (EPFL)
5 shared publications - Florian Fallegger
Sorbonne Université, CNRS, Inserm, Institut de la Vision, F-75012 Paris, France
3 shared publications - Giuseppe Schiavone
Department of Microsystems, Faculty of Technology, Natural Sciences and Maritime Sciences, University of South-Eastern Norway, Horten, Norway
3 shared publications - Erwan Bezard
Univ. Bordeaux, CNRS, Institut des maladies neurodégénératives, UMR 5293, Bordeaux, France
2 shared publications - Fabien B. Wagner
Univ. Bordeaux, CNRS, IMN, UMR 5293, F-33000 Bordeaux, France
2 shared publications - Grégoire Courtine
NeuroRestore, Swiss Federal Institute of Technology (EPFL), Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
2 shared publications
Latest Publications
- Open Access
- 8 March 2021
- Published by Wiley in Advanced Science
- Vol. 8 (9) , 2003761
MRI‐Compatible and Conformal Electrocorticography Grids for Translational Research
Intraoperative electrocorticography (ECoG) captures neural information from the surface of the cerebral cortex during surgeries such as resections for intractable epilepsy and tumors. Current clinical ECoG grids come in evenly spaced, millimeter‐sized electrodes embedded in silicone rubber. Their mechanical rigidity and fixed electrode spatial resolution are common shortcomings reported by the surgical teams. Here, advances in soft neurotechnology are leveraged to manufacture conformable subdural, thin‐film ECoG grids, and evaluate their suitability for translational research. Soft grids with 0.2 to 10 mm electrode pitch and diameter are embedded in 150 µm silicone membranes. The soft grids are compatible with surgical handling and can be folded to safely interface hidden cerebral surface such as the Sylvian fold in human cadaveric models. It is found that the thin‐film conductor grids do not generate diagnostic‐impeding imaging artefacts (<1 mm) nor adverse local heating within a standard 3T clinical magnetic resonance imaging scanner. Next, the ability of the soft grids to record subdural neural activity in minipigs acutely and two weeks postimplantation is validated. Taken together, these results suggest a promising future alternative to current stiff electrodes and may enable the future adoption of soft ECoG grids in translational research and ultimately in clinical settings.
- 8 March 2021
- Published by Wiley in Advanced Science
- Vol. 8 (9) , 2003761
Open AccessMRI‐Compatible and Conformal Electrocorticography Grids for Translational Research
Intraoperative electrocorticography (ECoG) captures neural information from the surface of the cerebral cortex during surgeries such as resections for intractable epilepsy and tumors. Current clinical ECoG grids come in evenly spaced, millimeter‐sized electrodes embedded in silicone rubber. Their mechanical rigidity and fixed electrode spatial resolution are common shortcomings reported by the surgical teams. Here, advances in soft neurotechnology are leveraged to manufacture conformable subdural, thin‐film ECoG grids, and evaluate their suitability for translational research. Soft grids with 0.2 to 10 mm electrode pitch and diameter are embedded in 150 µm silicone membranes. The soft grids are compatible with surgical handling and can be folded to safely interface hidden cerebral surface such as the Sylvian fold in human cadaveric models. It is found that the thin‐film conductor grids do not generate diagnostic‐impeding imaging artefacts (<1 mm) nor adverse local heating within a standard 3T clinical magnetic resonance imaging scanner. Next, the ability of the soft grids to record subdural neural activity in minipigs acutely and two weeks postimplantation is validated. Taken together, these results suggest a promising future alternative to current stiff electrodes and may enable the future adoption of soft ECoG grids in translational research and ultimately in clinical settings.
- Top Cited Papers
- 27 January 2021
- Published by Springer Nature in Nature
- Vol. 590 (7845) , 308-314
Neuroprosthetic baroreflex controls haemodynamics after spinal cord injury
Spinal cord injury (SCI) induces haemodynamic instability that threatens survival1,2,3, impairs neurological recovery4,5, increases the risk of cardiovascular disease6,7, and reduces quality of life8,9. Haemodynamic instability in this context is due to the interruption of supraspinal efferent commands to sympathetic circuits located in the spinal cord10, which prevents the natural baroreflex from controlling these circuits to adjust peripheral vascular resistance. Epidural electrical stimulation (EES) of the spinal cord has been shown to compensate for interrupted supraspinal commands to motor circuits below the injury11, and restored walking after paralysis12. Here, we leveraged these concepts to develop EES protocols that restored haemodynamic stability after SCI. We established a preclinical model that enabled us to dissect the topology and dynamics of the sympathetic circuits, and to understand how EES can engage these circuits. We incorporated these spatial and temporal features into stimulation protocols to conceive a clinical-grade biomimetic haemodynamic regulator that operates in a closed loop. This ‘neuroprosthetic baroreflex’ controlled haemodynamics for extended periods of time in rodents, non-human primates and humans, after both acute and chronic SCI. We will now conduct clinical trials to turn the neuroprosthetic baroreflex into a commonly available therapy for people with SCI.
- 27 January 2021
- Published by Springer Nature in Nature
- Vol. 590 (7845) , 308-314
Top Cited PapersNeuroprosthetic baroreflex controls haemodynamics after spinal cord injury
Spinal cord injury (SCI) induces haemodynamic instability that threatens survival1,2,3, impairs neurological recovery4,5, increases the risk of cardiovascular disease6,7, and reduces quality of life8,9. Haemodynamic instability in this context is due to the interruption of supraspinal efferent commands to sympathetic circuits located in the spinal cord10, which prevents the natural baroreflex from controlling these circuits to adjust peripheral vascular resistance. Epidural electrical stimulation (EES) of the spinal cord has been shown to compensate for interrupted supraspinal commands to motor circuits below the injury11, and restored walking after paralysis12. Here, we leveraged these concepts to develop EES protocols that restored haemodynamic stability after SCI. We established a preclinical model that enabled us to dissect the topology and dynamics of the sympathetic circuits, and to understand how EES can engage these circuits. We incorporated these spatial and temporal features into stimulation protocols to conceive a clinical-grade biomimetic haemodynamic regulator that operates in a closed loop. This ‘neuroprosthetic baroreflex’ controlled haemodynamics for extended periods of time in rodents, non-human primates and humans, after both acute and chronic SCI. We will now conduct clinical trials to turn the neuroprosthetic baroreflex into a commonly available therapy for people with SCI.
- 16 March 2020
- Published by Wiley in Advanced Materials
- Vol. 32 (17) , e1906512
Soft, Implantable Bioelectronic Interfaces for Translational Research
The convergence of materials science, electronics, and biology, namely bioelectronic interfaces, leads novel and precise communication with biological tissue, particularly with the nervous system. However, the translation of lab‐based innovation toward clinical use calls for further advances in materials, manufacturing and characterization paradigms, and design rules. Herein, a translational framework engineered to accelerate the deployment of microfabricated interfaces for translational research is proposed and applied to the soft neurotechnology called electronic dura mater, e‐dura. Anatomy, implant function, and surgical procedure guide the system design. A high‐yield, silicone‐on‐silicon wafer process is developed to ensure reproducible characteristics of the electrodes. A biomimetic multimodal platform that replicates surgical insertion in an anatomy‐based model applies physiological movement, emulates therapeutic use of the electrodes, and enables advanced validation and rapid optimization in vitro of the implants. Functionality of scaled e‐dura is confirmed in nonhuman primates, where epidural neuromodulation of the spinal cord activates selective groups of muscles in the upper limbs with unmet precision. Performance stability is controlled over 6 weeks in vivo. The synergistic steps of design, fabrication, and biomimetic in vitro validation and in vivo evaluation in translational animal models are of general applicability and answer needs in multiple bioelectronic designs and medical technologies.
- 16 March 2020
- Published by Wiley in Advanced Materials
- Vol. 32 (17) , e1906512
Soft, Implantable Bioelectronic Interfaces for Translational Research
The convergence of materials science, electronics, and biology, namely bioelectronic interfaces, leads novel and precise communication with biological tissue, particularly with the nervous system. However, the translation of lab‐based innovation toward clinical use calls for further advances in materials, manufacturing and characterization paradigms, and design rules. Herein, a translational framework engineered to accelerate the deployment of microfabricated interfaces for translational research is proposed and applied to the soft neurotechnology called electronic dura mater, e‐dura. Anatomy, implant function, and surgical procedure guide the system design. A high‐yield, silicone‐on‐silicon wafer process is developed to ensure reproducible characteristics of the electrodes. A biomimetic multimodal platform that replicates surgical insertion in an anatomy‐based model applies physiological movement, emulates therapeutic use of the electrodes, and enables advanced validation and rapid optimization in vitro of the implants. Functionality of scaled e‐dura is confirmed in nonhuman primates, where epidural neuromodulation of the spinal cord activates selective groups of muscles in the upper limbs with unmet precision. Performance stability is controlled over 6 weeks in vivo. The synergistic steps of design, fabrication, and biomimetic in vitro validation and in vivo evaluation in translational animal models are of general applicability and answer needs in multiple bioelectronic designs and medical technologies.
- 16 October 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 11 (514)
Microstructured thin-film electrode technology enables proof of concept of scalable, soft auditory brainstem implants
Engineered conformability in auditory brainstem implant electrode arrays improves the electrode-brainstem interface in mice and in human cadavers.
- 16 October 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 11 (514)
Microstructured thin-film electrode technology enables proof of concept of scalable, soft auditory brainstem implants
Engineered conformability in auditory brainstem implant electrode arrays improves the electrode-brainstem interface in mice and in human cadavers.
- 1 September 2017
- Published by Elsevier in Extreme Mechanics Letters
- Vol. 15, 63-69
Engineering reversible elasticity in ductile and brittle thin films supported by a plastic foil
- 1 September 2017
- Published by Elsevier in Extreme Mechanics Letters
- Vol. 15, 63-69
Engineering reversible elasticity in ductile and brittle thin films supported by a plastic foil